Critical Home Power. Economical Manual start Whole House AC Power For Amateurs. Hugh Maguire N1QGE

Similar documents
OCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012:

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Back Up Essential Circuits or Your Whole House. Protect the things that matter most.

Select and safely install a home generator

Gay E. Canough. OFF-GRID Design. Dr. Gay E. Canough, Master trainer. Living Off the Grid

SGB12000HX PORTABLE GENERATOR

Residential Standby Power

Electricity 1

Home Generator Systems BUYING GUIDE

PORTABLE GENERATORS 2016

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

DC disconnect. #4 AWG Negative wire

/ 120-VOLT ELECTRICAL SYSTEM

Portable generators 6,500 watt plus suggestions.

HOME GENERATOR SYSTEMS STANDBY SOLUTI NS PRODUCTS. Home Comfort Home Generator Systems

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

AUTOMATIC STANDBY GENERATORS

10KW GENERAC GENERATOR / SUBARU 18 HP ENGINE

Seal Beach Police Department

LETTER TO FAMILY. Science News. Cut here and glue letter onto school letterhead before making copies.

A direct current (DC) circuit. Alternating Current (AC) Direct Current DC. AC current. L 27 Electricity and Magnetism [4]

EVSE Load Balancing VS Load Shedding 1: Largest number of 30 Amps EVSEs that can be fed as per the code from the 600 volts feeder

Standby Electric Generators for Alaskan Residences. Advice & Installation

Commercially available generators useful for small-scale standby power fall into these categories: Type Wattage Approximate Price Range

Is Your Wiring System Safe and Energy Efficient?

PORTABLE GENERATORS SELECTION GUIDE PROVEN, ADVANCED, RELIABLE PERFORMANCE.

The Benefits of Battery Banks

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Electricity Merit Badge

XP800i POWER INVERTER OWNER S MANUAL

Montana State University: Solar Cells Lecture 9: PV Systems. Montana State University: Solar Cells Lecture 9: PV Systems

INSTALLATION & OPERATION MANUAL

Series. GP Series Portable Generators. Affordable reliability

E-technics.2k Electric work and power page 1 out of 5. A storiette out of every day life

CHAPTER V RESIDENTIAL WIRING

Installation and Construction Notes for EVSE4

Your Guide To Storm Safety

Please be aware that some things have no exact answer and opinions vary. Also not all situations are the same.

Most Cost Effective Solar Energy Solutions

DATASHEET TECHNICAL INFORMATION. Stationary applications, island solutions

12.7 Power in Electric Circuits

Standby POWER IN A PINCH

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR

INCREASE YOUR POWER FACTOR Manufactured By XZERES Corp.

For a sustainable future LIMITED

Stay in power. Battery consumption awareness

AUTOMATIC STANDBY GENERATORS PORTABLE GENERATORS

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Revision Date: Building a dual pump system for an open boat. Description:

3 Phase Voltage Imbalance

Working Principle of Power Saver as per Manufacture:

Is Your Water or Wastewater System Prepared? What You Need to Know About Generators. - a water system operator

HOW TO MAKE YOUR OWN BATTERIES

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

Wi Series. POWERHOUSE Wi SERIES INVERTER GENERATORS ELECTRICAL

Series. GP Series Portable Generators. Affordable reliability

30A SMART ENERGY MANAGEMENT SYSTEM TM

RESIDENTIAL GUIDELINE FOR ELECTRICAL VEHICLE (EV) CHARGER INSTALLATION

Inspection Points - Motor Homes

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Chapter 4 Utility Systems Electrical

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

VAC Electrical Requirements. VDC Electrical Requirements

GMC Unplugged. Adapting the GMC for dry camping

Do It Yourself Solar Photovoltaic (PV) Workshop. Jack Barnett Blair Buselli

Micro3 Grid Tied Residential Package

Standby Inverters. Written by Graham Gillett Friday, 23 April :35 - Last Updated Sunday, 25 April :54

X-Type w/ non-premium sound amplifier installation instructions

ATLAS Wheel Balancer Electrical Flow Chart

Hurricane Guide. What Can I Do To Prepare Now?

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Volt Meter for RV Direct Reading Battery Monitoring By Minnesota Fergie

How to design and build a solar lunch box

Components for your PV Solar Electric System

The Invision kit comes with everything you need to install the DVD players into your X5; two leather headrests with integrated DVD players, two

Off Grid Residential Package 1.0KW

RESIDENTIAL LIFE. HuskyMate Agreement. Apartment or Suite: Room #: Resident Name: Resident Name: Resident Name: Resident Name:

Trailer Systems (Gas, Water,& Electric) System View Point

Supplies: I purchased the following:

ATD WATT INVERTER

Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2

Alternatives to Truck Idling Workshop

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Generators. Automatic backup power for everyday life. Know you re protected with a Honeywell Home Generator

DID YOU KNOW? THE SOLUTION THE SITUATION THE BENEFITS OF OWNING A GENERATOR SYSTEM: THE FINANCIAL IMPACT $137 $500 TO $5,000 $1,900 $15,870 $2,910

ALAMEDA GREEN YOUR DREAM HOME SERIES

WHAT YOU DON T KNOW COULD BURN YOU! How To Avoid The Unknown Dangers Of Handling Fuel In Your Shop

POWERLINE 2000 Energy Management System TM

Product Information Guide

MEANWELL DC/AC POWER INVERTERS

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

Vehicle Fleet. Best Time RV FLEET... 2 RV VEHICLE SPECIFICATIONS... 4

UPFRO. Residential Electric. Voltage & Amperage

Standby Generators. Our company does electrical and

What happens to my B4RN connection (and internet telephone) when the power goes off?

Outdoor Enclosure Power System ENC X100MP48F20-AC6

R800-16PCPS DUAL REDUNDANT POWER SUPPLY FOR THE R RACK USER MANUAL

Standby Electric Power Systems For Agriculture

Transcription:

Critical Home Power Economical Manual start Whole House AC Power For Amateurs Hugh Maguire N1QGE

Goal of presentation Show how one amateur supplied all the critical loads in the home with minimal temporary wiring A pre-wired 240v system $$ less than the expense of a whole house installation This system ran for 5.5 days 24 hours a day during the December 2008 ice storm Critical loads defined as all those circuits that need to Be activated to allow family to function in the house During a prolonged power failure. (heating system)(refrigerator) Necessary loads are defined as those that allow family life To continue w/o too much sacrifice [not just the ham shack] More than one or two lights + (TV set)(garage door opener) (fish tank?)

First things first Open your home s breaker (fuse) Panel and make sure that you know What loads are connected where. 100 Label all circuits Should be done even if You are not considering A generator It usually is not realistic to power all the circuits So pick the needed ones Be sure to identify those Circuits that you must Have to function in the house (In winter or summer) Window A/C Oil Burner Refrigerator Well Pump Cable modem (VOIP) Bathroom Lights Kitchen Lights & Counter TV and Fish tank Sump Pump

Critical Loads Furnace w/pumps and motors and blowers etc. Refrigerator (turn off mullion heaters) Freezer Well Pump Sump Pump Ham shack Radios + heat and light Window A/C unit (5000-6000 BTUH) These have very high starting loads Fish tank heater Your family s needs may be different Most Generator web-sites will have lists with wattages ++

Necessary loads - you may want to time share but connecting and re-connecting gets old Light circuits, several kitchen and bath especially One wall outlet in kitchen for toaster or coffee pot Assume 1500 watts each (time share) Family TV circuit Cable or Satellite receiver Wireless phone circuit DSL modem circuit (hard wired phone) Cable VOIP equipment Garage door opener Computer (high quality power more later) Portable electric heat (usually 1500 watts each) Your family probably has a unique use Most Generator web-sites will have lists with wattages ++

10 Gage 4 wire From house connector 10 circuits (Choose at Time of Install) -Line -Off -Gen The author s interior power distribution 225A breaker panel with 10 Ckt. EmerGenSwitch panel Panel Connection To Breakers

House External 240 volt input connector 75 4 wire 10 gage SOJ ($$) cable

My Generator installation No modifications to generator

Cost Breakdown (estimate) Provide for all house critical and some necessary loads with A pre-wired system that allows for mostly normal lifestyle Generator manual start 4-5Kw 500-800 EmerGen & connect boxes 120-350 Electrician install labor ** 200-300 75 10GA - cable & connectors 60-120 Dedicated extension cords 50-100 Misc. fuel cans etc. 50-75 Total 950 1600 ** Electrician necessary to install EmerGen switch box Other items can probably be done by capable homeowner

Connecting the Breaker Panel to the EmerGen 6 Circuit 240 volt ($120) unit shown Multi-wire Connection To panel

10 Circuit EmerGenSwitch $225.00 Note the two 240 volt Option ties

G L1 N L2 Balance the generator load Know the existing wiring Plan for the house R & L sides of panel Mostly 120 volt loads 240 volt generator Feeds L1 & L2 loads Connect to both lines As equally as possible

Selecting a Generator 3600RPM gasoline ones are most affordable Size to start the biggest reactive load (motor) I have found the most Demanding starting load to be a 6-8000 KBTU window air conditioner A 4000 Watt average / 5000 Watt peak does the trick Too small and a big load will create quite annoying power drops at the least - or - cripple the system at worst. Too big and you simply waste fuel since the average load is often quite a bit less than 4000watts. (unless you are electric heating) Quiet economical reliable 12+ hour (overnight) run on fuel load Means a high quality unit is needed (low oil shutoff) (idle down circuit) Figure-out where it will be stored get wheels heavy about 160# Plan where it will be run during use more on noise later heavy duty (10Ga minimum) extension cord(s) A 240 volt 4 wire connection is needed because your house wiring Splits all the 120 volt circuits between 2 inputs.

Earth Ground 120 volt 120 volt 240 volts L1 Neutral L2

NEMA type receptacles L14-30R & L14-30P G L1 N L2 30 amp. 125/250 volt 3-Pole 4-Wire Grounding 2 hp rating. 7500 watt generator plug Note: these connectors can be Quite expensive ($15-$20 each) Female Receptacle Male Plug

Now.. How well do you get along with your neighbors? Your generator is liable to be running for some time & overnight Especially in the winter when you need to keep furnace running You want to minimize the noise to both yourself and your Neighbor (you will never eliminate it) Pick a spot outside for safety, away from the house if possible Most generators are weatherproof & made to run outdoors A tool shed is a good spot store the generator and its fuel and Maintain it and run it in the same spot (leave the door open) Regular maintenance during a multi-day outage is necessary this what I chose to do

My Generator installation inside a tool shed exhaust is Vented outdoors

Shed outside wall Cable port & Exhaust Port

Location. Location, Location, The Generator is located Away from the house And noise baffled Shed Safety, Safety, Safety, Carbon Monoxide And Fire Risk Is mitigated 10Ga 4 wire Cable connects To the house 75 House My breaker panel

External 240 volt input connector to house Outside Inside 75 4 wire 10 gage cable EmerGen panel is made To connect directly to Generator ok if located In garage etc.

Generator Key Features 4,000avg 5000peak watts Manual start OHV engine Idle-down Low oil shutdown Fuel gauge 4 gallon fuel tank 12-15 hour run time Quiet Operation Lifting Handle 240 volt 4 wire outlet Wheels! (about 160#) Safety First Frame of Generator Ground to earth

Maintenance & Testing & Accessories Good maintenance will pay dividends in reliability In general keep a small amount of fuel on the tank and run It every 2 months or so. Use the fuel shutoff and run the fuel Out of the carburetor. Do a complete all loads on test periodically let furnace, pumps and refrigerators cycle. Don t forget fuel storage modern gasoline does not keep well (keeps better in the winter) Don t keep it much more than 6 months use stabilizer NOTE: have a siphon on hand to get fuel from your car(s) if needed

Emergency power and Computers Emergency generators can easily provide recharge power For laptops don t forget that you will need to power your Cable / DSL modem. Emergency generators can provide power for a home Office / desktop computer but Care must be given to generator stability, voltage, and Frequency. Generator must be sufficiently sized so as to Not dip voltage dramatically during reactive load starts. (If you are serious about computer need get dedicated Generator for that application) A UPS can remain and is a help during times when reactive (motor) loads start and line voltage drops briefly know the Low voltage trip points.

Conclusion A solution that uses portable generating equipment Without lots of extension cords Requires a 4-5Kw - 240vac - generator Does require pre-planning Reasonable but measurable cost involved Allows family to continue most of daily lifestyle Could make your neighbor jealous (save one long Extension cord to send him a little)