BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Similar documents
BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

BAPI-Stat 3 Room Sensor

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration

DPS/MPS/RAH/RPS/SWP Space Sensor

VOC Duct and Rough Service Sensor

Installation and Maintenance Manual IM

Duct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

Digital Room Thermostats with Touch Screen LCD

Temperature Transmitters

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

SE8300 Series Installation Guide 24 Vac Low Voltage

Figure 1: WPR2 Dimensions and Hardware

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Installation and Operation Instructions DLP Series

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

SetPoint 150 Controller Installation Manual

MS Application. Features. Proportional Valve Actuator General Instructions

TM-9100 Series Room Command Module

Immersion Temperature Sensors

Compact Low Pressure Sensor

Low Pressure Sensor. Overview. Specifications. Installation and Operation

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

TC62D Installation Instructions

YCCS TE-6800 Series Temperature Sensors

A419ABG-3C Electronic Temperature Control

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

Combined Ventilation Controller RVWS-T-224HA

Section 55 Chapter 6

SMT-AZC INSTALLATION / OPERATION MANUAL

GE Measurement & Control

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

SEN and SEN Outdoor Air Temperature Sensors

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

J1000. Compact Inverter Series.

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

User Manual Solar Charge Controller 3KW

Installation and User Manual. with RAIN SENSOR.

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Description. functions including single duct pressure dependent or pressure independent systems.

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

INSTALLATION/OPERATING INSTRUCTIONS MCP

User Manual. Solar Charge Controller 3KW

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

SE7200 Series Installation Guide

1 Overview. 2 WPT Installation. WPT Installation Manual Document No , Rev 17. Wireless Pneumatic Thermostat- WPT-800 Series

LF Series At A Glance

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

INSTALLATION/OPERATING INSTRUCTIONS TSC

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

INTECH Micro 2300-RTD6

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Deadband Wireless Pneumatic Thermostat- WPT-800-DB Series

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

USERS MANUAL MCD REMOTE OPERATOR

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Installation Instructions & Users Manual

OE & OE Digital Room Sensor

Table of Contents. Carrier Sensors

TS , -850 Series TS , -850 Series TS-57031, TS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

CT325 TEMPERATURE CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTION

E.S.P. Embedded Sensing Probes for Motor Brushes

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Versatile and Powerful

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

J1000 D E F I 1000 J1000 J1000 J1000 J1000

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

MF /MS Series

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Package Contents. Mounting Hardware

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Transcription:

Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack. The setpoint is available as a resistance or voltage output. The override is a momentary closure signal that can be configured in parallel with the sensor or setpoint, or as a separate momentary output. Fig. 1: BAPI-Stat Quantum with slider setpoint adjustment, override button and provided screw pack. Mounting JUNCTION BOX 1. Pull the wire through the wall and out of the junction box, leaving about 6 inches free. 2. Pull the wire through the hole in the base plate. 3. Secure the base to the box using the #6-32 x 1/2 inch mounting screw provided. 4. Terminate the unit according to the guidelines in the Termination section. 5. Attach Cover by latching it to the top of the base, rotating the cover down and snapping it into place. 6. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until they are flush with the bottom of the cover. DRYWALL MOUNTING 1. Place the base plate against the wall where you want to mount the sensor. 2. Using a pencil, mark out the two mounting holes and the area where the wires will come through the wall. 3. Drill two 3/16 holes in the center of each marked mounting hole. Insert a drywall anchor into each hole. 4. Drill one 1/2 hole in the middle of the marked wiring area. 5. Pull the wire through the wall and out the 1/2 hole, leaving about 6 free. 6. Pull the wire through the hole in the base plate. 7. Secure the base to the drywall anchors using the #6 x 1 inch mounting screws provided. 8. Terminate the unit according to the guidelines in the Termination section. Fig. 2: Mounting hardware is provided for both J-Box and drywall installation (J-Box installation shown) 9. Attach cover by latching it to the top of the base, rotating the cover down and snapping it into place. Secure the cover by backing out the lock-down screws using a 1/16 Allen wrench until they are flush with the bottom of the cover. NOTE: In a wall-mount application, the mixing of room air and air from within the wall cavity can lead to erroneous readings, condensation, and premature failure of the sensor. To prevent this condition, plug the conduit hole with insulation in the junction box. 1 of 6

Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the National Electric Code (NEC) and local codes. Do NOT run this device s wiring in the same conduit as AC power wiring. BAPI s tests show fluctuating and inaccurate signals are possible when AC power wiring is in the same conduit as the signal lines. If you are experiencing any of these difficulties, please contact your BAPI representative. BAPI recommends wiring the product with power disconnected. Proper supply voltage, polarity and wiring connections are important to a successful installation. Not observing these recommendations may damage the product and void the warranty. Fig. 3: BAPI-Stat Quantum Circuit Board TERMINAL DESCRIPTION GND... Power Supply Ground (Common to the controller) V+... Power Supply Hot (See specs for voltage details) W1... Not Used OCCUPY... BAPI-Man Occ/Un-Occ indicator Input. Ground terminal to fill in the BAPI-Man icon for Occupied. SEN1 & SEN2... Sensor output per order (resistive). No polarity. *If the unit is a common ground configuration, see Grounding Note below. SET1 & SET2 A) Setpoint output per order (resistive). *If the unit is a common ground configuration, see Grounding Note below. B) Setpoint output per order (voltage). SET1 is +, SET2 is -. OVR1 & OVR2... Override Output (Dry contact) if unit is ordered with Override as a Separate Output (-J). The override can also be ordered as a momentary shunt across the sensor terminals SEN1 & SEN2 (-N) or as a momentary shunt across the setpoint terminals SET1 & SET2 (-P). *If the unit is a common ground configuration, see Grounding Note below. EXT-TEMP & EXT-GND.. Remote sensor terminals. No polarity. *If the unit is a common ground configuration, see Grounding Note below. To use these terminals, a 10K-2 thermistor sensor must be ordered separately and the temperature value from this sensor will be displayed on the LCD but will not be sent to the controller. Max wire distance for the external sensor is 25 feet. *Grounding Note: Common Ground or Differential Ground configurations are selected per order (Common Ground is default). The Differential Ground configuration indicates that SEN2, SET2, OVR2 and EXT-GND must all be wired separately (No internal common connection). The Common Ground configuration indicates that SEN2, SET2, OVR2 and EXT-GND are connected to GND internally (All internally common). 2 of 6

Optional Communication Jack Wiring Fig. 5: C35L Comm. Jack (3.5mm plug shown for clarity) C35L Comm. Jack Wiring Location WIRE COLOR Ground Black Tip White Ring Red Fig. 4: Back Plate Comm. Jack Locations Fig. 6: C11/C22 Comm. Jack C11L/C22L Comm. Jack Wiring PIN # WIRE COLOR 1 Not Connected 2 Black 3 Red 4 Yellow 5 Green 6 Not Connected Optional Test and Balance Switch (SW7) On the Test and Balance Switch (SW7), the NORM position allows the real sensor to be monitored. The HIGH position forces the output to a very hot reading and the LOW position forces a very cold reading (see Table below). Test and Balance Switch (SW7) LOW: Sets the sensor value low NORM: Sensor operates normally HIGH: Sets the sensor value high Sensor Type Low Temp (40 F) High Temp (105 F) Resistance Value Resistance Value 1000Ω RTD 1.02KΩ (41.20 F) 1.15KΩ (101.5 F) 3000Ω Thermistor 7.87KΩ (39.8 F) 1.5KΩ (106.8 F) 10K-2 Thermistor 30.1KΩ (34.9 F) 4.75Ω (109.1 F) 10K-3 Thermistor 26.7KΩ (35.9 F) 5.11KΩ (108.4 F) 10K-3(11K) Thermistor 7.32KΩ (43.7 F) 3.65Ω (105.2 F) 3 of 6

Front Panel & Control Descriptions BAPI-Man Icon Override Button Major Display Temperature Setpoint Slider Fig. 7: BAPI-Stat Quantum with Display, Slider Setpoint and Override. BAPI-Stat Quantum sensor comes with a display, slider setpoint adjustment and optional override. Temperature: Displayed in Fahrenheit or Celsius in the major display. (Field adjustable via the F/C switch on DIP Switch SW5.) Slider: Moving the slidepot enough to change the setpoint will display the setpoint in the major of the display. The setpoint temperature display will flash the digits indicating that setpoint is being changed. Override Button: When the override button is pressed on display units, the BAPI-Man Icon will display (Fig 8). A dry resistance of less than 15 ohms appears across the override output. Note: The unit must receive a confirmation (ground) signal on the OCCUPY terminal for the BAPI-Man to remain visible on the screen. Pressing the Override button will light the BAPI-Man icon; however, if no confirmation signal is received, then the BAPI-Man will go blank (disappear) after 5 seconds. Upon receiving a first confirmation (ground) signal on the OCCUPY terminal, the BAPI-Man will show occupied (Solid). The BAPI-Man will then show unoccupied (Hollow) whenever the confirmation signal is removed and occupied when the signal is returned. The only way to blank the BAPI-Man from the display after it has received a first confirmation signal is to cycle power. Solid equals Occupied Hollow equals Unoccupied Fig. 8: BAPI-Man Icon 4 of 6

Optional Technician Adjustments The unit is shipped ready to install. The following Setup or Program Menu Changes are available if the installer decides to change the factory settings. ENTERING PROGRAM MODE TO ADJUST PARAMETERS (see Figs 9-11 for adjustment tools) 1. Power unit and set DIP Switch SW5 #2 (PROG) to ON (right). The LCD will show a page number (P1-P9). P1-P9 will flash to indicate that display parameter can be adjusted. 2. Slide Potentiometer J1 is used to scroll up and down through pages and adjusting the page parameters. NOTE: For units with, the Slide Potentiometer will extend outside the enclosure. For units without, the Slide Potentiometer will not be extended outside the enclosure. 3. Push Switch SW8 as Enter to switch between page number and adjusting the page parameter. 4. After a page parameter has been adjusted, push Switch SW8 to confirm the change. 5. To exit Program Mode, Set DIP Switch SW5 #2 (PROG) to OFF (left). Note: DIP Switch SW5 #1 ( F/C) can be used to switch the display between F and C. Fig. 9: DIP Switch SW5 Parameter Temperature Offset Setpoint Lockout Temperature Display Display Low Display High Output Low Output High Value User Fan/Mode Setpoint Page P1 P2 P3 P4 P5 P6 P7 P8 P9 Programming Pages Adjustment ±5 in 0.1 increments Item Display Action 0 Setpoint Enabled Setpoint Disabled (pushbutton only): Display shows 1 setpoint when activated, but can't be changed Setpoint Display Only: Shows setpoint only, does not 2 display local temperature Setpoint Not Displayed: Setpoint can be changed, but 3 will not display Item Display Action 0 Display in whole digits 1 Display in 0.5 increments, F and C 2 Display in 0.1 increments, F and C Adjust the Low Temperature of the setpoint range Adjust the High Temperature of the setpoint range Shows Low Setpoint Output (Read Only. Displayed in 10 ohm resolution) Shows High Setpoint Output (Read Only. Displayed in 10 ohm resolution) Shows temperature setpoint value (Ready Only) Shows Fan/Mode setpoint on units configured with Mode/ Setpoint (Ready Only. Pushbutton only. Major display shows 0) Fig. 10: J1 Slide Potentiometer Fig. 11: Enter Switch SW8 5 of 6

General Diagnostics POSSIBLE PROBLEM: Temperature reading is incorrect Setpoint reading is incorrect Override is not working correctly POSSIBLE SOLUTIONS: - Verify that the input is set up correctly in the controller s and building automation software. - Check wiring for proper termination and check for opens or shorts. - Check for corrosion at either the controller or the sensor. Clean off the corrosion, re-strip the interconnecting wire and reapply the connection. In extreme cases, replace the controller, interconnecting wire and/or sensor. - Label the terminals at the sensor end and the controller end. Disconnect the interconnecting wires from the controller and the sensor. With the wires separated at both ends, measure the resistance from wire-to-wire with a multimeter. The meter should read greater than 10 Meg-ohms, open or OL depending on the meter you have. Short the interconnecting wires together at one end. Go to the other end and measure the resistance from wire-to-wire with a multimeter. The meter should read less than 10 ohms (22 gauge or larger, 250 feet or less). If either test fails, replace the wire. - Measure the physical temperature at the temperature sensor s location using an accurate temperature standard. Disconnect the temperature sensor wires and measure the temperature sensor s resistance across the sensor output pins with an ohmmeter. Compare the temperature sensor s resistance to the appropriate temperature sensor table on the BAPI website. If the measured resistance is different from the temperature table by more than 5% call BAPI technical support. Find BAPI s website at www.bapihvac.com; click on Resource Library and Sensor Specs then click on the type of sensor you have. Don t forget to reconnect the wires. - If the unit has a Test and Balance switch, make sure it is in the correct position. - Make sure that the setpoint output is correct. Remove the setpoint output wire and check the output for the correct resistance or voltage output. See the product label for your specific range. - Verify that the resistance across the override output is less than 15 ohms when the override is pushed. Specifications Power for 24VDC Power Units: 0 to 5 VDC Setpoint:... 9 to 40 VDC (24 VDC nominal) 0 to 10 VDC Setpoint:... 15 to 40 VDC (24 VDC nominal) Resistive Setpoint:... 9 to 40 VDC (24 VDC nominal) Any Allowed Setpoint:... 15 to 28 VAC (24 VAC nomimal) Note: AC power requires a separate pair of shielded wires Power Consumption: 13 ma max DC;.32 VA max AC Wiring: 22 to 16AWG Mounting: Standard 2x4 box or drywall (Screws provided) Outputs: Temperature: Thermistor or RTD : Resistive or Voltage Fan/System Control: Resistive Inputs: Dry contact (24V, <1mA) Occupied: OCCUPY terminal Grounded Unoccupied: OCCUPY terminal Open to Ground External Sensor: 10K-2 thermistor, Purchased separately, Wired 25 max from sensor Enclosure Material: ABS Plastic, UL94V-0 Environmental Ambient: Temperature: 32 to 122ºF (0 to 50ºC) Humidity: 0 to 95% RH Non-condensing Storage: 32 to 185 F (0 to 85 C) Agency: RoHS 6 of 6