DESCRIPTION The ArcLine 1' x 4' Series features a deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. The series produces total uniformity of light in the luminous area and is compatible with all of today s popular ceiling systems and is available with a number of options and accessories for application versatility. The specification luminaire is designed to offer maximum efficiency and performance for today s unique interior specifications. The ArcLine Series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. SPECIFICATION FEATURES Catalog # Project Comments Prepared by Metalux Date Construction -/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Ballast/ wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lamp-holder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral rid-lock feature for safety and convenience Controls Metalux LED luminaires come standard with -1V dimming drivers (1% standard). Options compatible with s Connected Lighting Systems: WaveLinx sensor LumaWatt Pro sensor SVPD sensor DLVP sensor and driver Fifth Light DALI driver Other options include stepdimming and 3rd party drivers. Refer to the Connected Lighting options page and ordering information for more details. Electrical* Long-Life LED system coupled with electrical driver to deliver optimal performance. LED s available in 3K, 3K or 4K with a minimum CRI of 8. Projected life is 6, hours at 91% lumen output. culus listed. Electronic drivers are available for 12-277V applications. Emergency Battery Pack Option Optional 12V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 9-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/ indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. Emergency/generator transfer options available see ordering information for details. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. Hinging/Latching Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. Frame/Sheilding Die formed heavy gauge, flat steel door with reinforced mitered corners and paint after fabrication, baked white matte enamel finish. Quadrasealed to prevent light spillage. Frosted acrylic profile lenses provide a soft but effective distribution of light. Compliance Modules are UL recognized components and indoor luminaires are culus listed for 2ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-8 standards. DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. Warranty Five year warranty. 14ALN LED 1' X 4' TROFFER LED MODULE Specification rade Troffer Curved Shielding CURVED -3/8" [138mm] 11-9/16" [29m] CERTIFICATION DATA culus 198 Damp Location Listed IC Rated LM79/LM8 Compliant ROHS Compliant DesignLights Consortium Qualified MOUNTIN DATA 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 1-1/2" [38mm] DOOR FRAMES ALN Flat, White Steel 11-3/4" [298mm] 3-1/2" [89mm] 48" [1219mm] -1/4" [133mm] 6-1/4" [19mm] Safe and convenient means of disconnecting power August 14, 218 11:3 AM
14ALN LED CURVED SHIELDIN CEILIN COMPATIBILITY rid/lay-in Standard Concealed T Slot rid F Aluminum Flange Trim With Supporting Swing ates Ceiling Exposed rid Concealed T Slot rid Flange Trim F (Verify compatibility/ consult Pre Sales Technical Support.) PHOTOMETRICS 26 3 79 16 14ALN-LD-26- UNV-L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.18 x mounting height, ( ) 1.22 x mounting height Lumens: 2633.9 Input Watts: 23.W Efficacy: 112.1 lm/w Test Report: 14ALN-LD-26- UNV-L83-CD1-U. IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 7 8 8 9 18 18 18 1 149 14 136 131 139 14 13 114 961 966 979 9 916 932 838 86 867 768 78 789 687 74 698 66 619 62 23 31 8 44 44 417 36 362 341 28 287 268 212 214 198 147 12 138 89 92 8 39 36 3 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 9 91 89 87 8 1 92 8 8 97 9 84 79 87 81 77 83 79 7 8 77 74 72 91 81 73 67 89 8 72 66 77 7 6 74 69 64 71 67 63 61 84 72 64 7 82 71 63 7 68 62 6 66 6 64 9 3 77 6 6 7 64 6 49 62 4 49 6 3 48 8 2 48 46 72 9 44 7 8 49 43 6 49 43 4 48 43 3 47 42 4 67 3 4 39 6 3 44 39 1 44 38 43 38 48 42 38 36 62 49 4 3 6 48 4 3 47 4 34 46 39 34 44 38 34 32 8 4 37 31 7 44 37 31 43 36 31 42 36 31 41 3 31 29 4 41 34 29 3 41 34 28 4 33 28 39 33 28 38 32 28 26 39 718 177 1436 14ALN-LD-3- UNV-L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.18 x mounting height, ( ) 1.21 x mounting height Lumens: 372.8 Input Watts: 34.W Efficacy: 13.6 lm/w Test Report: 14ALN-LD-3- UNV-L83-CD1-U. IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 7 8 8 9 1433 1433 1433 1429 142 1427 142 1396 146 138 138 1371 1297 13 1324 1224 1239 127 1133 116 117 136 16 163 928 91 941 82 837 819 77 72 689 61 64 73 491 494 463 388 39 368 29 294 272 23 29 191 12 126 18 4 47 4 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 89 91 89 87 8 1 92 8 8 97 9 84 79 86 81 77 83 79 7 8 77 74 71 91 81 73 67 89 8 72 66 77 7 6 74 69 64 71 67 63 61 84 72 64 7 82 71 63 7 68 62 6 66 6 64 9 2 77 6 6 7 64 49 62 4 49 6 3 48 8 2 48 46 72 9 44 7 8 49 43 6 48 43 4 48 43 3 47 42 4 66 3 4 39 6 2 44 39 1 44 38 49 43 38 48 42 38 36 62 49 4 3 6 48 4 3 47 39 34 4 39 34 44 38 34 32 8 4 37 31 7 44 37 31 43 36 31 42 36 31 41 3 31 29 4 41 34 28 3 41 33 28 4 33 28 39 33 28 38 32 28 26 Zonal Lumen Summary Zone Lumens % Fixture -3 86 3.6-4 1294 49.1-6 218 81.9-9 2634 1. -18 2634 1. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 2888 29 2869 28 2614 24 2272 2288 2137 1914 1979 1797 18 1392 116 Zonal Lumen Summary Zone Lumens % Fixture -3 191 3. -4 17 49. -6 2921 81.8-9 373 1. -18 373 1. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 398 3989 393 331 348 3366 394 311 2934 2643 2721 2487 288 1817 146 Peachtree City, A 3269 P: 77-486-48 August 14, 218 11:3 AM
14ALN LED CURVED SHIELDIN LUMEN MAINTENANCE Ambient Temperature TM-21 Lumen Maintenance (6, hours) Theoretical L7 (Hours) 2 C > 91% > 238, ENERY AND PERFORMANCE DATA BY CATALO NUMBER Stock or MTO* Catalog Logic (Rectilinear Shielding) Delivered Lumens Watts Efficacy (lm/w) MTO 14ALN-LD-23-UNV-L83-CD1-U 221 2.6 19 MTO 14ALN-LD-23-UNV-L83-CD1-U 234 2.6 114 MTO 14ALN-LD-23-UNV-L84-CD1-U 234 2.6 114 MTO 14ALN-LD-26-UNV-L83-CD1-U 229 23. 18 MTO 14ALN-LD-26-UNV-L83-CD1-U 2634 23. 112 MTO 14ALN-LD-26-UNV-L84-CD1-U 2634 23. 112 MTO 14ALN-LD-31-UNV-L83-CD1-U 34 29.4 14 MTO 14ALN-LD-31-UNV-L83-CD1-U 3181 29.4 18 MTO 14ALN-LD-31-UNV-L84-CD1-U 3181 29.4 18 MTO 14ALN-LD-3-UNV-L83-CD1-U 343 34. 1 MTO 14ALN-LD-3-UNV-L83-CD1-U 373 34. 14 MTO 14ALN-LD-3-UNV-L84-CD1-U 373 34. 14 MTO 14ALN-LD-4-UNV-L83-CD1-U 3897 4.9 9 MTO 14ALN-LD-4-UNV-L83-CD1-U 49 4.9 99 MTO 14ALN-LD-4-UNV-L84-CD1-U 49 4.9 99 *Made to order (MTO) requires a typical four week lead time. Peachtree City, A 3269 P: 77-486-48 August 14, 218 11:3 AM
14ALN LED CURVED SHIELDIN ORDERIN INFORMATION SAMPLE NUMBER: 14ALN-LD-3-UNV-L83-CD1-U Rating [Blank]= Standard ATW-SW4= Chicago Rated Series () 14ALN=1x4 ArcLine Series Trim =rid/lay-in (Standard) (1) =Concealed T =Slot rid F=Aluminum Flange Trim (8) Lamp LD=LED. LED Lumens Output 23=23 Lumens 26=26 Lumens 31=31 Lumens 3=3 Lumens 4=4 Lumens Shielding [Blank]=Smooth Frosted Acrylic, Curved (Standard) Option Aluminum Flange Trim (8) Blank=SW (Single White) Color S Single N Natural R In Row W White E End of Row Voltage (2) 347V=347 Volt (6) UNV=Universal Voltage 12-277 48V=48 Volt Low-voltage (Class 2) Options Emergency EL7W=7-watt, 12V-277V emergency battery pack installed (3) EL14W=14-watt 12V-277V emergency battery pack installed (3) ELV7W=7-watt, DLVP-compatible low voltage emergency battery pack installed (C) ELV14W=14-watt DLVP-compatible low voltage emergency battery pack installed (C) TR2=Bodine enerator Transfer Relay (7) ETRD=Iota Emergency Transfer Relay with dimming control (7) CCT L83=3K L83=3K L84=4K Flex A3/8-4/18DIM=3/8" Flex with -1V Dimming Leads Multiple other configurations available. See below for details. Driver Number of Drivers CD=-1V Dimming Driver 1=1 Driver (1%-1% Dimming) SR=Sensor-ready Dimming Driver for LWIPD1 option (1%-1% Dimming) (B) LTD=Fifth Light DALI Driver (4), (E) (1%-1% Dimming) LTHD=Fifth Light Dimming Driver (1%-1% Dimming) (E) LV1=DLVP Dimming Driver (%-1% Dimming) (C) SD=Step Dimming Driver (% or 1% Dimming) (4) LH=Lutron HiLume (LDE1 series) 1%-1% EcoSystem Driver with Soft-on Fade to Black dimming (F) L=Lutron Series (LDE-Series) %-1% EcoSystem Driver (F) LU=Lutron HiLume (L3D series) 1%-1% EcoSystem/3-wire Driver (F) Integrated Sensing Systems SWPD1=WaveLinx Wireless Integrated Sensor (A) LWIPD1=LumaWatt Pro Wireless Integrated Sensor (B) LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (B) SLVPD1=DLVP Low-voltage Integrated Sensor (C) SVPD1=-1V Stand-alone Integrated Sensor (D) Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) F2M-14S-W-U=Field Installed Flange Kit DF-14-W=1' x 4' Drywall Frame Kit DF1P-C =Decorator Dimmer, -1V SF1P- =Decorator Slide Dimmer, -1V SK-14-WT=Field Install Surface Mount Kit, Tall ISHH-1=Programming Remote for Integrated Sensor (D) ISHH-2=Personal Control Remote for Integrated Sensor (D) NOTES: (1) An EQ rid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2) Products also available in non-us voltages and frequencies for international markets. (3) With integral test switch/ indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (1 lm/w x 7=7 lumens). IES-format photometry for luminaire under emergency operation available. (4) 23, 26, 31 and 3 lumen packages not available with Step-dim (SD) and Fifth Light (LTD) driver option. () DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. (6) 347V versions are not available with emergency options. (7) Used to bypass local control during outage. Must be used in conjunction with UL 18 device (provided by others). TR2 option includes 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 12V or 277V when ordering these devices. (8) Specify row configuration type in the Catlog number when ordering the complete fixture. Integrated Sensing and Control System Options NOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) Consult LumaWatt Pro system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. Flexible Metal Conduit Options Flex options available for -1V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 9 enclosed FMC connector. Not all options may be combined and installation ratings vary by type. A3/8-4/18DIM series notes: Factory installed dimming option 3/8 flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed -1V +/- control wires. Meets UL 66, 83, 1479, 169, 181, 26. NEC 2.118, 3.22(C), 392, 396, 33, 1, 2, 3, 3, 4,, 18, 2, 3, 64, 72; Federal Specification A-A-944 (formerly J-C-3B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC ; Environmental Air-Handling Space Installation per NEC 3.22(C ). Specifications & Consult your Representative for availability and ordering information. SHIPPIN DATA Catalog No. 14ALN-LD-26 14ALN-LD-3 Wt. 19 lbs. 19 lbs. Peachtree City, A 3269 P: 77-486-48 August 14, 218 11:3 AM
LO SET MIN INTERATED SENSOR 14ALN LED CURVED SHIELDIN The ArcLine with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The ArcLine delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the ArcLine delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-1). The integrated sensor personal remote (Catalog Number: ISHH-2) provides code compliant manual raise, lower, ON, OFF control. The ArcLine with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 2 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. 1 Energy Savings Opportunities Light Level (DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level (DU) Unoccupied Level Unoccupied Occupied Unoccupied Occupied Target light level default: lux at 8 ft. Coverage Coverage Top View C L 3.3m [1 ft.] Side View m [ ft.] Major Motion m [ ft.] m [ ft.] Reccomended Mounting Height 8 12 ft. Optional Remote Control Raise/ Lower Time Out HI 1 ES 1 7 2 Occ MAX To Set Output Un Occ 1. Raise, Lower or Press Min., 7, Max. 2. To save press SET 3. Select Occ or Un Occ Programming Remote ISHH-1 Peachtree City, A 3269 P: 77-486-48 August 14, 218 11:3 AM