Type EK 9F61 Series Medium Voltage Fuse Holders & Clips

Similar documents
Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Support / Disconnect Selection Guide

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

D I D /240 I. D x /240 I D / x x /24 I. D x /120

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Type SJK Test Switches

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

L11 Fused and Non-Fused Disconnect Switches (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.


Table 1d - FSA for All Returns, Females Tax Year

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

Medium Voltage Fuses

Current-limiting fuse mounts

E-RATED/MEDIUM VOLTAGE FUSES

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017


TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

Limitor -G General Purpose Fuses

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW)

IEC Standard Back-Up Fuse-Links

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

S&C Recloser Bypass Disconnects

References 4 Fuse carriers

Bussmann series IEC cylindrical fuses

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

600V, Non-Fusible, (3-Pole, 3 Phase)

Negative (sliding on the track)

M/1000, Heavy Duty Cylinders Double Acting

Industrial Control Transformers

UL 98 Fusible Disconnect Switches

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Monorail. Monorail CCD FOR MONORAIL/SKYTRAIN FEATURES & BENEFITS APPLICATIONS STANDARDS CURRENT COLLECTOR SYSTEM (CCD)

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

Parts Lists. Forward Series. Rev. Feb. 2017

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Low-Peak 600V Class RK1

Parts Lists. Novel Series. Rev. Feb. 2017

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

RBA Catalog Numbers and Information

Snap-in covers I Voltage taps

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Spare Parts. SPC-2 Sanitary Electro-Pneumatic Modulating Valve SP70736-GB

SPECIFICATION BULLETIN

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Positive Track with fuse box included

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

9070T150D1 Industrial Control Transformer, 150VA

Type MTS Miniature Test Switches

Pipe Supports PS 1. PO Box Highbrook Auckland

Medium voltage fuses Medium voltage fuses

Outdoor Enclosure Power System ENC X100MP48F20-AC6

Operation and Maintenance manual. fusible shunt trip switch

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

C1000 Series Automatic Cap Bank

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

8WH2 Spring-Loaded Terminals

CATALOG. Blackburn Flexible braids

Industry s most comprehensive medium voltage circuit protection

FX Full-Range Current-Limiting Fuse

NFPA 70E Standard for Electrical Safety Requirements for Employee Workplaces. Table Hazard Risk Category Classification

Single Socket and Horizontal Metering

Chargestar T26 / T45. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Contactors & Starters Index

8WH2 Spring-Loaded Terminals

Outdoor Enclosure Power System ENC X100MP48F20

Set-up, Operation & Maintenance Manual

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

Fuse Box on Bogies 750VDC

Solar Power Switchgear & Energy Storage Renewable Energy Systems

SY PVC / BS EN Control Flexible Cable

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

TA Ta VA CTRL-XFRMR

3 - Protection components Motor circuit-breakers

Industrial Control Transformers

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

Set-up, Operation & Maintenance Manual

Pretest Module 24 Three-phase Service Entrance

CURRENT -LIMITING FUSE UNITS TYPES EJ-2 AND EJ0-2 FOR MOTOR CIRCUITS

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

LIFTKET wire rope winch with wall bracket or foot support

PHOENIX CONTACT

Variable Frequency AC Motor Drive Units

Transcription:

Type EK 961 Series Medium Voltage use Holders & lips USE LOKS & HOLERS USE SUPPORTS, USE ISONNET SWITHES, AN AESSORIES ROM 2.4KV TO 38KV use supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. isconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. use supports and disconnecting switches include live parts for both ends. oth fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors. Indoor: use supports:...ek-1 use disconnect switches:... EK-3 The letter suffix following the (-1) or the (-3) shows the fuse size. When selecting a mounting for a current-limiting fuse, it is necessary that the clip centers and size agree with the fuse selected. Outdoor: use supports:...eko-1 use disconnect switches:.... EKO-3 or detailed information regarding these fuse supports and disconnecting switches such as storage, mounting and maintenance, please refer to INST-EK39196 available on our website at ep.mersen.com or ask your sales representative for a hard copy. use Size EE errule iameter 1-9/16 inches 2 inches 3inches two-3 inch in parrallel four-3 inch in parrallel two-4 inch in parrallel USE SUPPORT - EK-1 INOOR EK-1 EK-1 EK-1 EK-1 EK-1EE EK-1 Refer to drawings for specific dimensions. 2018 Mersen. All rights reserved. Mersen reserves the right to change, update, EP.MERSEN.OM or correct, without notice, any information contained in this datasheet. 45

TYPE EK 961 SERIES Medium Voltage use Holders & lips USE LOKS & HOLERS USE SUPPORT - EK-1 INOOR atalog No. Max. kv errule Size/ iam. lip enters (Live Parts) (lips) Insulator Rating - lass/nema Nominal Sys. (kv) Insulator Rating - IL (kv) 961A101 2.75/5.5 /1.56 8.12 961NW450 961WW460 4.8 60 A-20 961AG101 8.25 /1.56 8.12 961NW450 961WW460 13.8 95 A-20 961AG101 15.5 /1.56 11.5 961NW450 961WW460 13.8 95 A-20 961AJ101 15.5 /1.56 11.5 961NW450 961WW460 14.4 110 A-20 961AA201 2.75 /2.00 7 961NW451 961WW457 4.8 60 A-20 961A201 5.5 /2.00 9 961NW451 961WW457 4.8 60 A-20 961AEG201 15.5 /2.00 12 961NW451 961WW457 13.8 95 A-20 961AGG201 15.5 /2.00 15 961NW451 961WW457 13.8 95 A-20 961AGJ201 15.5 /2.00 15 961NW451 961WW457 14.4 110 A-20 961AHM201 25.8 /2.00 21 961NW743 961WW457 23 150 A-20 961AA301 2.75 /3.00 7 961NW750 961WW459 4.8 60 A-20 961AE301 2.75/5.5 /3.00 12 961NW750 961WW459 4.8 60 A-20 961AEG301 8.25 /3.00 12 961NW750 961WW459 13.8 95 A-20 961AGG301 15.5 /3.00 15 961NW750 961WW459 13.8 95 A-20 961AGJ301 15.5 /3.00 15 961NW750 961WW459 14.4 110 A-20 961AHM301 25.8 /3.00 21 961NW744 961WW459 23 150 A-20 961AA401 2.75 /3.00 7 961NW751 4.8 60 A-20 961AE401 2.75/5.5 /3.00 12 961NW751 4.8 60 A-20 961AEG401 8.25 /3.00 12 961NW751 13.8 95 A-20 961AGG401 15.5 /3.00 15 961NW751 13.8 95 A-20 961AGJ401 15.5 /3.00 15 961NW751 14.4 110 A-20 961AHM401 25.8 /3.00 21 961AWW738 23 150 A-20 961A501 5.08 EE/4.00 14.12 961NW452 4.8 60 A-20 961AG501 15 EE/4.00 14.12 961NW452 13.8 95 A-20 961AJ501 15 EE/4.00 14.12 961NW452 14.4 110 A-20 961AHG001 15 or olted-end uses refer to drawings. 96 961AK001 5.5 or olted-end uses refer to drawings. 60 lass/nema Tech Ref. 46 EP.MERSEN.OM

USE LOKS & HOLERS TYPE EK 961 SERIES Medium Voltage use Holders & lips ISONNET SWITH - EK-3 INOOR EK-3 EK-3 EK-3 atalog No. Max. kv errule Size/ iam. lip enters (Live Parts) (lips) Nominal Sys. (kv) IL (kv) lass/nema Tech Ref. 961AA205 2.75 /2.00 7 961NW731 961WW457 4.8 60 A-20 961A205 5.5 /2.00 9 961NW731 961WW457 4.8 60 A-20 961AEG205 15.5 /2.00 12 961NW731 961WW457 13.8 95 A-20 961AGG205 15.5 /2.00 15 961NW731 961WW457 13.8 95 A-20 961AGJ205 15.5 /2.00 15 961NW731 961WW457 14.4 110 A-20 961AHM205 25.8 /2.00 21 961NW746 961WW457 23 150 A-20 961AA305 2.75 /3.00 7 961NW732 961WW459 4.8 60 A-20 961AE305 2.75/5.5 /3.00 12 961NW732 961WW459 4.8 60 A-20 961AEG305 8.25 /3.00 12 961NW732 961WW459 13.8 95 A-20 961AGG305 15.5 /3.00 15 961NW732 961WW459 13.8 95 A-20 961AGJ305 15.5 /3.00 15 961NW732 961WW459 14.4 110 A-20 961AHM305 25.8 /3.00 21 961NW747 961WW459 23 150 A-20 961AA405 2.75 /3.00 7 961NW461 4.8 60 A-20 961AE405 2.75/5.5 /3.00 12 961NW461 4.8 60 A-20 961AEG405 8.25 /3.00 12 961NW461 13.8 95 A-20 961AGG405 15.5 /3.00 15 961NW461 13.8 95 A-20 961AGJ405 15.5 /3.00 15 961NW461 14.4 110 A-20 961AHM405 25.8 /3.00 21 961NW748 23 150 A-20 Refer to drawings for specific dimensions. EP.MERSEN.OM 47

TYPE EK 961 SERIES Medium Voltage use Holders & lips USE LOKS & HOLERS USE SUPPORT - EKO-1 OUTOOR EKO-1 EKO-1 EKO-1 EKO-1 atalog No. Max. kv errule Size/iam. lip enters (Live Parts) (lips) Nominal Sys. (kv) IL (kv) lass/nema Tech Ref. 961E209 2.75/5.5/8.25 /2.00 12 961NW743 961WW457 7.5 95 202 961GL209 15.5 /2.00 15 961NW743 961WW457 15 110 205 961HM209 25.8 /2.00 21 961NW743 961WW457 23 150 208 961E309 2.75/5.5/8.25 /3.00 12 961NW744 961WW459 7.5 95 202 961GL309 15.5 /3.00 15 961NW744 961WW459 15 110 205 961HM309 25.8 /3.00 21 961NW744 961WW459 23 150 208 961JN309 38 /3.00 27 961NW744 961WW459 34.5 200 210 961E409 2.75/5.5/8.25 /3.00 12 961AWW738 7.5 95 202 961GL409 15.5 /3.00 15 961AWW738 15 110 205 961HM409 25.8 /3.00 21 961AWW738 23 150 208 961JN409 38 /3.00 27 961AWW738 34.5 200 210 961K009 5.5 or olted-end uses refer to drawings. Refer to drawings for specific dimensions. 48 EP.MERSEN.OM

USE LOKS & HOLERS TYPE EK 961 SERIES Medium Voltage use Holders & lips ISONNET SWITH - EKO-3 OUTOOR EKO-3 EKO-3 Open Position EKO-3 atalog No. Max. kv errule Size/iam. lip enters (Live Parts) (lips) Nominal Sys. (kv) IL (kv) lass/ NEMA Tech Ref. 961E210 2.75/5.5/8.25 /2.00 12 961NW746 961WW457 7.5 95 202 961GL210 15.5 /2.00 15 961NW746 961WW457 15 110 205 961GN210 15.5 /2.00 15 961NW746 961WW457 34.5 200 210 961HM210 25.8 /2.00 21 961NW746 961WW457 23 150 208 961E310 2.75/5.5/8.25 /3.00 12 961NW747 961WW459 7.5 95 202 961GL310 15.5 /3.00 15 961NW747 961WW459 15 110 205 961HM310 25.8 /3.00 21 961NW747 961WW459 23 150 208 961JN310 38 /3.00 27 961NW747 961WW459 34.5 200 210 961E410 2.75/5.5/8.25 /3.00 12 961NW748 7.5 95 202 961GL410 15.5 /3.00 15 961NW748 15 110 205 961HM410 25.8 /3.00 21 961NW748 23 150 208 961JN410 38 /3.00 27 961NW748 34.5 200 210 Refer to drawings for specific dimensions. EP.MERSEN.OM 49

TYPE EK 961 SERIES Medium Voltage use Holders & lips USE LOKS & HOLERS AESSORIES AN SPARE PARTS Hinge Trunions and Operating Eyes for Use on isconnecting Switches use Size Hinge Trunion Model No. Operating Eye Model No. 961JW397 961W394 961KW398 961AWW612 961LW399 961AWW612 EK-3 961W394 EK-3 and 9A61AWW612 EKO-3 961JW397 EKO -3 961KW398 EKO-3 961LW399 50 EP.MERSEN.OM

USE LOKS & HOLERS TYPE EK 961 SERIES Medium Voltage use Holders & lips USE SIZE (ERRULE IAMETER 1.5625 ) use Supports & isconnect Switches 961A101 Spare Live Parts(*) igure (ig.) Spare use lips(**) igure (ig.) use size 961AG101 961AG101 961NW450 961WW460 961AJ101 USE SIZE (ERRULE IAMETER 2") use Supports & isconnect Switches 961AA201 961A201 Spare Live Parts(*) igure (ig.) Spare use lips(**) igure (ig.) use size 961AEG201 961NW451 961AGG201 961AGJ201 961AA205 961A205 961AEG205 961NW731 961AGG205 961AGJ205 961AHM201 961WW457 961E209 961GL209 961HM209 961AHM205 961E210 961GL210 961HM210 961NW743 961NW746 (*) Spare Live Parts: Order (1) Live Parts for each use Support and isconnecting Switch (includes live parts for both ends). (**) use lips: Order (2) use lips for each use Support and order (1) use lip for each isconnecting Switch. EP.MERSEN.OM 51

TYPE EK 961 SERIES Medium Voltage use Holders & lips USE LOKS & HOLERS USE SIZE (ERRULE IAMETER 3") use Supports & isconnect Switches 961AA305 961AE305 Spare Live Parts(*) igure (ig.) Spare use lips(**) igure (ig.) use size 961AEG305 961AGG305 961AGJ305 961AHM301 961E309 961GL309 961HM309 961NW732 961NW744 961JN309 961AHM305 961WW459 961E310 961GL310 961HM310 961NW747 961JN310 961AA301 961AE301 961AEG301 961NW750 961AGG301 961AGJ301 (*) Spare Live Parts: Order (1) Live Parts for each use Support and isconnecting Switch (includes live parts for both ends). (**) use lips: Order (2) use lips for each use Support and order (1) use lip for each isconnecting Switch. or the 3 ferrule diameter we also offer the at # 228-700-530 clips. These spring reinforced clips will accomodate one and two barrel 3-inch diameter medium voltage ferrule type fuses. The clip and reinforcing spring are intended to be bolted to a copper busbar through two.41 and 1.06 slots. A minimum copper-bus section of 1/4 x 1-1/2 is recommended for maximum ratings of 24R and 450E. The at # 228-700-530 is for one pair of clips, enough for one fuse. 52 EP.MERSEN.OM

USE LOKS & HOLERS TYPE EK 961 SERIES Medium Voltage use Holders & lips USE SIZE (ERRULE IAMETER TWO 3" IN PARALLEL) use Supports & isconnect Switches Spare Live Parts(*) igure (ig.) Spare use lips(**) use size 961AHM401 961E409 961GL409 961HM409 961JN409 961AA405 961AE405 961AEG405 961AGG405 961AWW738 961NW461 961AGJ405 961AHM405 961E410 N/A 961GL410 961NW748 961HM410 961JN410 961AA401 961AE401 961AEG401 961AGG401 961NW751 961AGJ401 ONVERSION KIT TO OR USE ON USE SUPPORTS Model No. igure (ig.) Used on live parts igure (ig.) 961NW402 961NW751 (Indoor) 961AWW738 (Outdoor) USE SIZE EE (ERRULE IAMETER TWO 4" IN PARALLEL) use Supports & isconnect Switches Spare Live Parts(*) igure (ig.) Spare use lips(**) use size 961A501 EE 961AG501 961NW452 N/A EE 961AJ501 (*) Spare Live Parts: Order (1) Live Parts for each use Support and isconnecting Switch (includes live parts for both ends). (**) use lips: Order (2) use lips for each use Support and order (1) use lip for each isconnecting Switch. EE EP.MERSEN.OM 53