SPECIFICATION SHEET : FHS2-UNV-36L

Similar documents
This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

FHS2-UNV-36L INSTALLATION INSTRUCTIONS

FHS2-UNV-56S SPECIFICATIONS

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

UL AND CODE COMPLIANCE

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Cat# DC LED Array Emergency Driver

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

FHSCP-UNV-10P-L-SD SPECIFICATIONS

MODEL : FHS2-UNV-36L

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Installation and Operation Instructions 10/04/13

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

SURE-LITES FBP140XLP Instruction Manual

621 Recessed LED Downlights - 2

FHEZ10A24 FHEZ10A24 - CEC 24" EZ EXIT EM T-Grid

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

Installation Instructions Central Battery Units

610 Recessed LED OpticLites

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

120VAC / Universal Input Rectangular LED DC Engines and LED DC Engine Retrofit Kits

622 Recessed LED Wallwash - 4

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

621 Recessed LED Downlight - 6

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Table of Contents. Ordering Instructions 4. Grande RM4D LED - Direct RM4D QuickShip Part Number 5 RM4D Row Configurations 6-9

MaxLite LED UTILITY WRAP FIXTURES

The reliable, flexible choice for easy LED emergency driver design-in

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instruction

Morris Products 53 Carey Road, Queensbury, NY 12804

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

Cynergy Series Retrofit Kit

LED Emergency Drivers

Lumen Maint. (Hrs.) 2

Lumen Maint. (Hrs.) 2

LED Emergency Drivers

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

IMPORTANT SAFEGUARDS

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

AccuPower AQU126B Installation Instructions

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

B33 INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

MANUFACTURED IN THE UK

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

Linear Line Voltage LED Engine

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

TrustSight LED Emergency Lighting

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

MANUFACTURED IN THE UK

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

AUTO CHARGE LPC SERIES

style with efficiency

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

AccuPower AQU128B Installation Instructions

PDX and PX Retrofit Series

Self-Testing Industrial Series

VR44-MU-xxx-8yy-xxxxA

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Project Name ADEO AD22 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

Project Name. 24 (609.6mm) 24 (609.6mm)

Project Name. 23-3/4 (603.3mm)

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

CONVERJ CJ22 2x2 Architectural Recessed

Project Name ADEO AD14. Adeo 1x4 (AD14) 1x4 Architectural Recessed. (76.2mm) EMERGENCY

CONVERJ CJ14 1x4 Architectural Recessed

Project Name. 24 (609.6mm)

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

Special Specification 6058 Battery Back-Up System for Signal Cabinets

CONVERJ CJ24 2x4 Architectural Recessed

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

MODEL 422 Submersible Pump Controller

light FULL BLEED APPLICATION SHOT RENDERING

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Installation Instructions

Spectron Industrial Series

Recessed. EvoKit LED Retrofit Kits Gen 3

Transcription:

SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working voltage between 11-36VDC and not exceeding 20W. ELECTRICAL DATA INPUT VOLTAGE 100V ~ 277V ± 10%, 50/60Hz SURGE PROTECTION C62.41 (MOV) OVER CURRENT PROTECTION Fuse INPUT CURRENT 0.07 A INPUT POWER < 4 W THROUGHPUT CURRENT HANDLING RED LEAD 3A, 60V Max. WHITE/BLACK LEAD 100W Max. OUTPUT CURRENT 100m A - 700m A (Refer to accesory chart) OUTPUT WORKING VOLTAGE 11-36VDC OUTPUT SHORT CIRCUIT PROTECTION SelfResetting PTC R E C H AR G E T IM E R E Q U IR E D 2 4-4 8 H o u rs (R e fe r to b a tte ry c h a rt) BATTERY TYPE NiCd 9.6VDC or LiFePO4 9.6VDC BATTER Y C APAC ITY AVAILABLE.9Ah, 1Ah, 1.2Ah, 1.5Ah, 1.8Ah, 3Ah, 4Ah, 6Ah ILLU MIN ATION TIME MIN IMU M 90MIN, U PTO 360MIN (AVAILABLE) TOTAL MAXIMUM LED POW ERED 20W OUTPUT CLASSIFICATION Class 2 AMBIENT TEMPERATURE 0ºC-50ºC NiCd, 10ºC-50ºC LiFePO4, -20 C-50 C (FHSBATCC3-3) C E R T IF IC AT IO N S curus 1310, curus 924 EMERGENCY LED DRIVER & LiFePO4 BATTERIES RoHS compliant 1.69 1.52 1.17 R 0.09 5.34 5.01 WIRE LENGTH - INCHES FRONT VIEW WIRING DIAGRAMS BLACK WHITE RED BLK/WHT BATTERY-LED ARRAY-TEST SWITH-PILOT LIGHT 12 ±1 12 ±1 24 ±1 18 ±1 24 ±1 FHS2-UNV-36L RIGHT VIEW FHS2-UNV-36L 4.69 INPUT/OUTPUT WIRES (REFER TO WIRING DIAGRAM BELOW) TEST SWITCH 100mA - 700mA harness LED ARRAY BATTERY Disconnected for Shipping.93 WIRING DIAGRAM (TYP) WHITE(COMMON) Accessory Harness (Wire length 24") Part Number Description Part Number Description FHS-HARNESS-100 100 ma LED Harness FHS-HARNESS-150 150 ma LED Harness FHS-HARNESS-200 200 ma LED Harness FHS-HARNESS-250 250 ma LED Harness FHS-HARNESS-300 300 ma LED Harness FHS-HARNESS-350 350 ma LED Harness FHS-HARNESS-400 400 ma LED Harness FHS-HARNESS-450 450 ma LED Harness FHS-HARNESS-500 500 ma LED Harness FHS-HARNESS-550 550 ma LED Harness FHS-HARNESS-600 600 ma LED Harness FHS-HARNESS-650 650 ma LED Harness FHS-HARNESS-700 700 ma LED Harness LINE WALL SWITCH BLACK WHITE LED DRIVER BALLAST MUST BE GROUNDED HOT( 120V ~ 277V) LED ARRAY RED (+) BLUE (-) BLACK WHT/BLK RED (+) TEST SWITCH BLK RED BATTERY FHS2-UNV-36L 2010-251-1 rev T

GENERAL INSTALLATION GUIDELINES FOR LED EMERGENCY DRIVER MODEL : FHS2-UNV-36L IMPORTANT SAFE PRACTICES When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: Do not connect battery until fixture is installed. IMPORTANT: An un-switched AC power source of 100VAC to 277VAC is required. This device is designed for use in fixtures listed for dry and damp locations. CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. CAUTION: Do not let power supply cords touch hot surfaces. CAUTION: Do not mount near gas or electric heaters. CAUTION: Battery is rechargeable Ni-Cad or LiFePO4 type and must be recycled or disposed of properly. Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. Do not use this emergency driver for other than intended use. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. IMPORTANT: Indicator (LED light) illuminated indicates battery in charge mode when AC power is applied. It is recommended and required by applicable code to test emergency ballast to ensure proper function of the system; push the test switch for thirty (30) seconds every 30 days to ensure the emergency driver is functioning as LED light source illuminated. Conduct a ninety minute (90) discharge test one time (1) per year; LED light source should be illuminated for a minimum of ninety minutes (90). ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly or installation of emergency driver. TESTING SYSTEM: The emergency battery requires a charge minimum of one (1) hour before testing the circuit. A full charge requires twenty four (24) or thirty six (36) or forty eight (48) hours, depending upon battery pack. Please refer to battery chart for charging time. SAVE THESE INSTRUCTIONS 2010-251-2 rev T

FRONT VIEW RIGHT VIEW BLK/WHT TO LED DRIVER (100W MAX.) RED BLK WHT INPUT POWER TO LED (+) INPUT LED ARRAY TEST SWITCH NOTE: DRILL ½ DIA. HOLE IN MOUNTING PLATE TO INSERT TEST SWITCH BATTERY WIRING DIAGRAM (TYP) WHITE(COMMON) LINE HOT( 120V ~ 277V) BLACK WHT/BLK WALL SWITCH BLACK WHITE LED DRIVER RED (+) BLUE (-) RED (+) TEST SWITCH FHS2-UNV-36L BALLAST MUST BE GROUNDED BLK LED ARRAY RED BATTERY WIRING DIAGRAM (EMERGENCY ONLY) WHITE(COMMON) HOT( 120V ~ 277V) BLACK WHT/BLK RED (+) TEST SWITCH FHS2-UNV-36L LED ARRAY BLK RED BATTERY 2010-251-3 rev T

Battery Chart Fulham Model No. Chemistry Compliant Pack Capacity Max Load for 90 min. Battery Voltage Recharge Time FHSBATT8-AA.9 NiCd 900mAh 4W 9.6V 24Hrs FHSBATT8-C3 NiCd 3000mAh 16W 9.6V 32Hrs FHSABATT8-D4 NiCd 4000mAh 20W 9.6V 32Hrs FHSBATL3-1 LiFePO4 1000mAh 4W 9.6V 24Hrs FHSBATL3-1.5 LiFePO4 1500mAh 8W 9.6V 24Hrs FHSBATL3-3 LiFePO4 3000mAh 16W 9.6V 32Hrs FHSBATL6-1.5 LiFePO4 3000mAh 16W 9.6V 32Hrs FHSBATL6-3 LiFePO4 RoHS 6000mAh 20W 9.6V 48Hrs FHSBATL6-.6 LiFePO4 1200mAh 6W 9.6V 24Hs FHSBATL9-.6 LiFePO4 1800mAh 10W 9.6V 24Hrs FHSBATL6-1.5L* LiFePO4 3000mAh 16W 9.6V 32Hrs FHSBATL6-3L* LiFePO4 6000mAh 20W 9.6V 48Hrs FHSBATT8-C3L* NiCd 3000mAh 16W 9.6V 32Hrs FHSBATCC3-3 LiFePO4 RoHS 3000mAh 10W 9.6V 32Hrs FHSBATL6-1.5S LiFePO4 RoHS 3000mAh 16W 9.6V 32Hrs FHSBATL3-1.5S LiFePO4 RoHS 1500mAh 8W 9.6V 24Hrs CAUTION: Replace battery only with corresponding part number. * Note: These batteries do not include mounting means, separate mounting brackets are available. Harness Extension Battery Model Number Harness Part Number Description FHSBATT8-AA.9 FHS-EXT12L HotSpot 12" Battery Extension FHSBATT8-C3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATT8-D4 FHS-EXT12H HotSpot 12" Battery Extension FHSBATL3-1 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-1.5 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-1.5 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-.6 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL9-.6 FHS-EXT12M HotSpot 12" Battery Extension FHSBATCC3-3 FHS-EXT12M HotSpot 12" Battery Extension FHSBATL6-1.5S FHS-EXT12M HotSpot 12" Battery Extension FHSBATL3-1.5S FHS-EXT12M HotSpot 12" Battery Extension 2010-251-4 rev T

Battery Dimensions 5.23 4.72 4.09 2.50 2.39 FHSBATT8-AA.9 4W, 900mA, 9.6V R.07 4.11 FHSBATT8-C3 16W, 3000mA, 9.6V 3.29 2.17 2.78 R.07.66 2.17 4.15 2.11 2010-251-5 rev T

Battery Dimensions 3.48 3.48 2.97 2.97 2.29 FHSBATL3-1 4W, 1000mA, 9.6V 2.70 FHSBATL3-1.5 8W, 1500mA, 9.6V 1.14 1.35 R0.07 R0.10 R0.07 2.37 R0.10 0.91 0.91 4.39 5.70 3.88 5.19 2.76 1.41 FHSBATL3-3 16W, 3000mA, 9.6V 2.70 FHSBATL6-1.5 16W, 3000mA, 9.6V 1.35 R0.07 R0.10 3.27 R0.07 R0.10 1.22 4.59 0.91 2010-251-6 rev T

Battery Dimensions 4.89 2.50 3.84 2.72 FHSBATT8-D4 20W, 4000mA, 9.6V 3.33 R.07 2.72 4.95 2.66 7.52 2.76 FHSBATL6-3 20W, 6000mA, 9.6V R.07 6.40 1.22 2010-251-7 rev T

Battery Dimensions 5.23 4.72 1.81 FHSBATL6-.6 6W, 1200mA, 9.6V R0.07 4.11 0.79 7.52 R.07 7.01 1.81 FHSBATL9-.6 10W, 1800mA, 9.6V 6.40.85 2010-251-8 rev T

1 MODEL : FHS2-UNV-36L Battery Dimensions 7.89 1.56 FHSBATL6-1.5L 16W, 3000mA, 9.6V Do not apply pressure, contains critical components at this location. 0.92.76 Mounting Bracket Dimensions (Optional) 9.07 8.56 3.00 R.15 0.79 1.63 0.91 FHSBATSC6-1.5L R.08 1.94 R.10 7.96 0.94 0.41 0.59 2010-251-9 rev T

Battery Dimensions 7.94 2.17 FHSBATL6-3L 20W, 6000mA, 9.6V Do not apply pressure, contains critical components at this location. 1.21 1.07 Mounting Bracket Dimensions (Optional) 9.13 8.62 3.96 3.00 1.18 FHSBATSC6-3L 1.18 2.21 R0.10 R0.08 2.52 1.29 0.646 8.01 3.00 2010-251-10 rev T

Battery Dimensions 7.89 2.17 FHSBATT8-C3L 16W, 3000mA, 9.6V 1.04 Mounting Bracket Dimensions (Optional) 9.08 8.57 3.94 3.00 R0.2 1.18 FHSBATSC8-C3L 1.18 2.18 R.08 2.52 1.07 0.61 3.00 2010-251-11 rev T

Battery Dimensions FHSBATCC3-3 10W, 3000mAh, 9.6V FHSBATL6-1.5S 16W, 3000mAh, 9.6V FHSBATL3-1.5S 8W, 1500mAh, 9.6V 2010-251-12 rev T

PRODUCT SPECIFICATION SHEET ILB-SL-CP10 CONSTANT POWER LED EMERGENCY DRIVER SLIM PROFILE FOR NARROW COMPARTMENTS MODEL NO: TYPE: PROJECT: COMMENTS: LED LED OPERATION 10W LED Load @ 10-60VDC nom. 1 OUTPUT 10 Watts (Constant) DESCRIPTION The ILB-SL-CP10 from IOTA is a UL Classified LED emergency driver that allows the same LED fixture to be used for both normal and emergency operation. In the event of a power failure, the ILB-SL-CP10 switches to the emergency mode and operates the existing fixture for 90 minutes. The unit contains a battery, charger, and converter circuit in a single slim profile can for installation within the channel space or wireway. The ILB-SL-CP10 will operate an LED array load at 10 watts with constant power at a rated output voltage of 10-60 VDC. The Constant Power design of the ILB-SL-CP10 maintains the output wattage to the LED array even as the system voltage diminishes, providing a consistent illumination level for the full 90-minute emergency duration. SPECIFICATIONS Input Voltage... (Universal) 120-277V, 50/60Hz Input Rating... 3.7 Watts (max) Output Voltage 1... 10-60 VDC Class 2 Compliant Output Current... 1.0A (@10VDC) - 0.167A (@60VDC) Output Power... 10 Watts (constant) Power Factor... 0.9 Emergency Operation... 90 minutes Operating Temp... 0 to 55 C THD... < 20% Battery... High Temp Nickel Cadmium 24 Hour Recharge 7-10 Year Life Expectancy Weight... 3.5 lbs. Approval... UL and CUL Classified as an LED emergency driver for field installation 1 Max. output voltage in emergency mode is 58.5 VDC with a + tolerance of 1.5 volts DIMENSIONS 24.17 x 1.2 x 1.2 (mounting center 23.78 ) PRODUCT ADVANTAGES Classified for field installation Constant Power Design maintains illumination throughout the 90-minute runtime with no light degradation Slim Profile housing allows integral installation within restrictive and narrow channel spaces of strip and troffer fixtures Two-wire universal AC input Self-sensing output voltage allows the CP Series to operate various product types, reducing product SKUs for emergency options FEATURES UL 924 Listed, UL Classified to FTBV UL 1310 Certified, Output Class 2 Compliant Long life high temperature recyclable Ni-Cad battery Galvanized steel case Includes single-piece TBTS test switch and charge indicator accessory kit For use with switched or unswitched fixtures 5-Year Warranty. See Warranty Page for details. Meets or exceeds all NEC, IBC, and Life Safety Code Emergency Lighting Requirements Rated for use in Plenum, Damp Location, Recessed Type IC, and Enclosed and Gasketed Luminaires RoHS Compliant LENGTH 24.17 HEIGHT 1.2 MOUNTING CENTER 23.78 WIDTH 1.2 IOTA REV 072116 Patented. See www.iotaengineering.com/patents for details. Product specifications are subject to change without notice IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com

ILB-SL-CP10 CONSTANT POWER LED EMERGENCY DRIVER TEST KIT CONFIGURATION TBTS ACCESSORIES TMK-ISL Top Mount Cover When top-mounting the ILB-SL-CP unit, the TMK-ISL is used to cover the exposed wiring that goes from the battery pack into the fixture. TMK ILB-CP FIXTURE ILB-SL-CP10 SAMPLE SPECIFICATION Supply and install IOTA ILB-SL-CP10 Constant Power emergency LED driver system as indicated on the plans. The emergency driver shall be designed for internal or external mounting to the luminaire including a self-contained, high-temperature, sealed, maintenance-free nickel cadmium battery rated for a 10-year service life. The unit shall be provided complete with an illuminated push to test switch. The emergency driver system shall be UL class 2 certified in accordance with UL 1310 and shall be UL listed for use in damp locations and in enclosed and gasketed fixtures with a temperature range of 0 to 55 C. The AC input shall be a two-wire, universal voltage capable 120 thru 277 VAC, 50/60 Hz and be UL Classified to Category Control Number (CCN) FTBR, Emergency Lighting and Power Equipment, and FTBV, Emergency Light-Emitting-Diode Drivers for field installation. Maximum input power of the emergency driver shall be 3.7 watts. The unit charger shall consist of a two-stage charging system which samples the battery in relation to its temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected with reverse polarity protection. A low voltage battery disconnect (LVD) circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches approximately 80 to 85% of its nominal terminal voltage, preventing a non-recoverable, deep-discharge condition as well as equipment initialization failure when utility power is restored. The unit shall achieve a full recharge in 24-hours. The emergency driver shall accommodate an LED load with a forward voltage requirement ranging from 10 to 60 VDC. The output voltage sensing shall be automatic and instantaneous with a resulting, inversely-proportional current to maintain constant power to the LED array with an output tolerance of +/- 3%. The unit shall supply the rated load for a minimum of 1 1/2 hours or to 87 1/2% of rated battery terminal voltage. The output power to the LED load during emergency operation shall be held constant 10 watts from minute one throughout the entire emergency run time resulting in no loss or degradation of the light source during emergency operation. The unit shall be furnished with an electronic, AC-lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will enable a transfer to emergency operation when utility power dips below an acceptable level. Maximum remote mounting distance of the emergency driver shall be 50-feet. SPECIFICATION TOOLS FOR UL CLASSIFIED FIELD INSTALLATION The ILB-SL-CP10 is UL Classified for Field Installation. Refer to the CP Series Compatibility and Suitability of Use Guidelines addendum for complete project installation requirements. IOTA ILB-CP PERFORMANCE CALCULATOR Visit www.iotaengineering.com/cptools to access our on-line CP performance calculator for assistance when determining lumen output and operating specifications for your unit, in addition to convenient links to other specification materials. IOTA REV 072116 Patented. See www.iotaengineering.com/patents for details. IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com

BSL310 (polycarbonate case) BSL310C (metal case with conduit) BSL310M (metal case without conduit) BSL310C-DF (metal case with dual conduit) Emergency Driver for Linear LED Strips Class 2 Output Product Summary UL RECOGNIZED Factory Installation * (Indoor and Damp) Output Class 2 Compliant *BSL310 is field installable when used with the Philips EvoKit G2 LED Retrofit luminaire. Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 60 ma Maximum AC Input Power Rating 4.0 W Maximum Output Current and Voltage Selectable (See Table 1) Without Selector: minimum 200 ma, 35-50 VDC, minimum 300 ma over optimized range (30-34 VDC) With Selector: minimum 400 ma, 10-29 VDC Output Power 10.0 W (Maximum) Test Switch/Charging Indicator Light Illuminated Test Switch Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +55 C (32 F to 131 F) Dimensions (BSL310) 14.5 x 2.25 x 1.18 (369 mm x 58 mm x 30 mm) Mounting Center 14.0 (356 mm) Dimensions (BSL310C/M) 15.34 x 2.25 x 1.16 (390 mm x 58 mm x 29 mm) Mounting Center 15.0 (381 mm) x 1.37" (34.8mm) Weight 2.25 lbs. (1.0 kg) - polycarbonate 3.15 lbs. (1.43kg)- metal w/o conduit 3.45 lbs. (1.56kg)- metal w/conduit 3.80 lbs. (1.73kg)- metal w/dual conduit Specifiers Reference Project Type Model No. Comments 1.18 2.25 1.16 2.25 1.16 2.25 14.5 BSL310 EMERGENCY DRIVER FOR LINEAR LED STRIPS 14.0 15.34 BSL310C EMERGENCY DRIVER FOR LINEAR LED STRIPS 15.0 16.87 BSL310C-DF EMERGENCY DRIVER FOR LINEAR LED STRIPS 15.0 A Division Of Philips Electronics North America Corporation Application The BSL310 universal input (120-277 V) emergency LED driver works in conjunction with an AC LED driver that has an output current not to exceed 3.0 A. The emergency driver consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one case. The BSL310 can deliver up to 10 watts to an LED load (measured at nominal battery voltage) for 90 minutes. If used in an emergency-only fixture, no AC driver is necessary. The BSL310 is suitable for indoor and damp locations. For more information about specific LED and AC driver compatibility, please call the factory. Operation When AC power fails, the BSL310 immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency driver automatically returns to the charging mode. A patented circuit delays AC LED driver operation for up to 5 seconds to prevent over current of LED's that would occur if both drivers supply the load at the same time. Installation The BSL310 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency driver. The emergency driver must be fed from the same branch circuit as the AC driver. Per UL requirements, the polycarbonate BSL310 must be enclosed if remote mounted outside of the fixture. Installation is not recommended with fixtures where the ambient temperature may fall below 0 C. The product is suitable for installation in sealed and gasketed fixtures. For LED loads rated less than 30V, connect the load select per Table 1 for proper operation and optimum performance. The BSL310C-DF is offered in two options. Both are equipped with two flexible metal conduits. For option A, the illuminated test switch is located in one conduit and product wiring in the other. *BSL310 is field installable when used with the Philips EvoKit G2 LED Retrofit luminaire. Option B contains the illuminated test switch wiring in its own conduit, with the test switch and a wall plate included in a separate parts kit. UL and Code Compliance The BSL310 has been tested by Underwriters Laboratories in accordance with the standards set forth in UL UL 924, Emergency Lighting and Power Equipment, and by the Canadian Standards Association (CSA) in accordance with the standards set forth in C22.2 No. 141, Unit Equipment for Emergency Lighting. The BSL310 is UL Listed and CSA Certified for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA- LSC), National Building Code of Canada (NBC), National Fire Code of Canada (NFC) and UL 90-minute requirements. L2300211 1.37 1.37 03/04/15 Philips Emergency Lighting P.O. Box 460 Collierville, TN USA 38027-0460 Sales 800-223-5728 FAX 901-853-5009 Tech. Support 888-263-4638 www.philips.com/bodine

(polycarbonate case) BSL310 (metal case with conduit) BSL310C (metal case without conduit) BSL310M (metal case with dual conduit) BSL310C-DF Emergency Illumination The BSL310 operates an LED load of up to 10.0 W at nominal battery voltage for a minimum of 90 minutes. Specification Emergency lighting shall be provided by using a LED fixture equipped with a Philips Bodine BSL310 universal input (120-277 V) emergency driver. A patented circuit delays AC LED driver operation for up to 5 seconds to prevent over current of LED's that would occur if both drivers supply the load at the same time. This emergency driver shall consist of a high-temperature, maintenance-free nickel-cadmium battery, charger and electronic circuitry contained in one case. An illuminated test switch (ITS) to monitor charger and battery and installation hardware shall be provided. The emergency driver shall be capable of delivering up to 10 watts to an LED load for a minimum of 90 minutes. The BSL310 is suitable for indoor and damp locations. The BSL310 shall have a maximum of 4.0 watts of input power and a 24.0 Watt-hour battery capacity and shall comply with emergency standards set forth by the current NEC. The emergency driver shall be UL Recognized for factory installation only and shall be warranted for a full five years from date of purchase. Warranty Model BSL310 is warranted for five (5) full years from date of purchase. This warranty covers only properly installed Philips Bodine emergency LED drivers used under normal conditions. For the warranty period, Philips Emergency Lighting will, at its option, repair or replace without charge a defective emergency LED driver, provided it is returned to the factory transportation prepaid and our inspection determines it to be defective under terms of the warranty. Repair or replacement, as stated above, shall constitute the purchaser s exclusive warranty, which does not extend to transportation, installation, labor or any other charges; nor does it apply to any equipment of another manufacturer used in conjunction with the emergency driver. Emergency Driver for Linear LED Strips Class 2 Output Benefits: Enables LED Linear strip fixtures to meet Emergency Code requirements Emergency mode lumen output of up to 1300 lumens Universal input (120-277 VAC) 2 wire input reduces wiring errors Compatible with a variety of LED strip manufacturers Compatible with AC drivers and LED loads rated for Class 2 Selectable Output Compatible With* Philips Xitanium 40 W SR Driver Philips LEDline Samsung U990048 LG Lightbox *Contact Factory for compatibility with other LED applications IMPORTANT TEXT: REFER TO TABLE 1 REGARDING LOAD SELECT Table 1 LOAD SELECT OPTIONS MAXIMUM LOAD VOLTAGE 10V - 29V 30V - 50V LOAD SELECT CONNECTED NOT CONNECTED TABLE 2a. UL CLASSIFIED LOADS Manufacturer Series Reference Manufacturer s Part Number Philips Fortimo LED Line 1ft 1100lm 830 3R HV1 Philips Fortimo LED Line 1ft 1100lm 835 3R HV1 Philips Fortimo LED Line 1ft 1100lm 840 3R HV1 Philips Fortimo LED Line 1ft 1100lm 850 3R HV1 Philips Fortimo LED Line 1ft 1100lm 865 3R HV1 Philips Fortimo LED Line L2EVO1.5 ft 1250lm 830-1 Philips Fortimo LED Line L2EVO1.5 ft 1250lm 835-1 Philips Fortimo LED Line L2EVO1.5 ft 1250lm 830-1 TABLE 2b. Listed Luminaires Manufacturer Philips Model Number EvoKit LED Retrofit Luminaire Philips LEDline Wire Gauge (AWG) Table 3 REMOTE DISTANCES Maximum Remote Mounting Distance* (ft) Maximum Wire Length** (ft) 10 500 1000 12 300 600 14 200 400 16 125 250 18 75 150 20 50 100 22 30 60 24 20 40 26 13 26 * Total wire length can NOT exceed that given in Maximum Wire Length column. ** Distance is round trip wire length. Distances are for Emergency Driver only. Consult AC Driver specification for remote mounting distances when using AC Driver. L2300211 03/04/15 Philips Emergency Lighting P.O. Box 460 Collierville, TN USA 38027-0460 Sales 800-223-5728 FAX 901-853-5009 Tech. Support 888-263-4638 www.philips.com/bodine For the most current technical information and notices, please visit TechNotes on our website.