APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Similar documents
APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Large Embedded Generation User Guide A

Residential PV-the City of Cape Town s experience Brian Jones Head: Green Energy/Electricity Services City of Cape Town South Africa

Net Metering Interconnection Requirements

Major Customer Connections. Preliminary Enquiry Form Embedded Generation > 30 kw

Guidelines for connection of generators:

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Louisville Gas and Electric Company

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Enquiry Form for Micro and Small Generators 5MW and Less

GUIDELINES FOR THE INSTALLATION OF EMBEDDED GENERATION

PSNH INTERCONNECTION REQUEST

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Enquiry Form (Non-Registered Generator With Capacity less than 5 MW)

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Net +Plus Connection Code

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Adopted: September 24, 2015 Version: Version 1.0

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

TERMS AND CONDITIONS

London Hydro Connection Checklist

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Consumer Guidelines for Electric Power Generator Installation and Interconnection

STATE OF NORTH DAKOTA DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS TABLE OF CONTENTS

Utilities (Technical Regulation) (Electricity Transmission Supply Code) Approval 2016 (No 1)*

Form C Renewable Energy Micro-Generation Connection Application Distribution System

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

MICHIGAN ELECTRIC UTILITY

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Impact of Distributed Energy Resources on Transmission System Reliability

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

JEA Distributed Generation Policy Effective April 1, 2018

Municipality Generator Interconnection Application Single Meter Application Part I

Please Refer to Attached Sample Form

Application for Net Export Rebate

GUIDELINES FOR EMBEDDED GENERATION. Application process to become an embedded generator in the City of Cape Town

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Appendix 6.7 January 23, 2015 SURPLUS ENERGY PROGRAM PROPOSED TERMS AND CONDITIONS

Export limits for Embedded Generators up to 200 kva connected at Low Voltage

Interconnection Process for Generation Systems

White River Electric Association, Inc. Net Metering Information & Service Requirements

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

Jemena Electricity Networks (Vic) Ltd

Micro Embedded generation

NET METER REQUEST FORM

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff.

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members

DAKOTA ELECTRIC ASSOCIATION DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS

Micro-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

Umatilla Electric Cooperative Net Metering Rules

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

RULES ENABLING THE NET- METERING PROGRAM FOR RENEWABLE ENERGY

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

Guideline for Parallel Grid Exit Point Connection 28/10/2010

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

Definitions. Scope. Customer Generation Interconnection Requirements

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined

FRENCH BROAD ELECTRIC MEMBERSHIP CORPORATION RATE SCHEDULES

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

To complete the process for a net metering interconnection, please follow the steps below:

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings:

ROANOKE ELECTRIC COOPERATIVE RATE SCHEDULES

BC Hydro Rate Schedules Effective: August 1, 2015 Fourth Revision of Page 30

Connecting your business diesel generation

Purpose. Background. Exclusions

Request for Payment Instructions form. Rule 21 Non-Exporting Generators Submittal Instructions

GUIDELINES FOR OPERATING, METERING AND PROTECTIVE RELAYING FOR. NET METERED SYSTEMS UP TO 50 kw AND BELOW 750 VOLTS

MICHIGAN ELECTRIC UTILITY

Distributed Generation Interconnection Policy

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No.

SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY

MICHIGAN ELECTRIC UTILITY

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

PHILIPPINE DISTRIBUTION CODE 2017 EDITION

NZQA unit standard version 8 Page 1 of 5. Apply and remove earths from conductors on electricity supply networks

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

Net Metering Service. Customer Information Package

Transcription:

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Work Order No: File Reference: 16/2/1 This application form for the connection of small scale embedded generation is for small scale embedded generators to be installed by residential, commercial or industrial customers. It is applicable to all forms of embedded electricity generation, including renewable energy and cogeneration. A separate Electricity Supply Agreement form must also be completed, except for installations where reverse power blocking is to be installed. If the embedded generator is to be configured as a standby supply after islanding from the municipal electrical grid, the generator will have to be connected to the existing internal wiring of the property. In such a case, the property owner must obtain a certificate of compliance from a qualified electrician and complete COMMISSIONING REPORT as per appendix 3. New Installation Revised application System upgrade Change of ownership Other: (specify) Erf No: Township/Ward Account No: Initials & Surname: Title: Postal Address: E-mail address : Postal Code: Fax No: Street (Physical) VAT Registration No: Address / Location: Contact No: Home Work Cell phone Indicate: Residential Business Industrial Group development Other: (e.g. farm specify) Planned construction schedule: Projected construction start date Projected commencement date Energy to be used for own electricity grid and no excess to be exported to municipal electrical grid. Concentrated Solar Power Motive for small scale embedded generation: (Tick appropriate box) Energy to be used for own Energy to be used solely electricity grid and excess for exporting to municipal to be exported to municipal electrical grid. electrical grid. Small Hydro Expected Life of Embedded Generation Project Battery storage: No Yes kwh Wind Energy to be used for wheeling to third party through municipal electrical grid. Photovoltaic Type of generation: (Tick appropriate box) Landfill Biomass Bio Gas gas Cogeneration Fossil fuel generation years Type of energy conversion: (Tick appropriate box and include operating characteristics). Synchronous generator Asynchronous /Induction generator Inverter Fuel-cell Dyno set Site location: Latitude(dd mm sss) S Longitude(dd mm sss) E For commercial/industrial only (show location and dimensions of intended installation infrastructure in relation to the existing property point of connection and buildings.) Site land use zoning: (Attach copy of zoning certificate) Preliminary design 1 : (to be attached) Circuit diagram & design showing major components, proposed point of common coupling, isolating & interfacing devices with municipal grid, protection schemes, customer grid, operating characteristics. 1 For guidance here, it is recommended that an installer/supplier be consulted.

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 2 Earthing arrangements i.e. TN-C-S Generator Info: Total capacity of small scale embedded generation (kva and PF 2 ): (Attach schedule for each unit if more than one generation unit and location) Make Three phase Total Export Generation Capacity ((kva) and PF) (Maximum power intended for export into Municipal grid) Single phase Model kva kva Amps Power Factor Property distribution board main circuit breaker size: Ampere (A) Three phase Single phase Proposed consumption and generation levels: (Complete the table below) Month Estimated imported energy for month (kwh) (Electricity bought from utility once SSEG is installed) Estimated exported energy for month (kwh)(electricity generated by SSEG & not utilised for own use) Estimated maximum instantaneous exported power (kva) Day of week that maximum power export occurs Time of day maximum power export occurs January February March April May June July August September October November December Total N/A N/A N/A Brief explanation of the reasons for the general load profile and electricity export profile as demonstrated above: Point of Common Coupling: (Isolation point to be used to connect/disconnect embedded generation from the Distribution Network, attach single-line diagram showing arrangement including consumer network). Network Connection Point: (In the case of applicant not being an existing consumer only, attach single-line diagram showing arrangement). 2 This will mainly apply to systems that make use of rotating machines e.g. wind power, hydro or diesel generators. For static power converters (e.g. inverters with a solar PV system), the power factor is generally 1 and the kwp of the system will be the same as the kva.

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 3 Protection Details: (Attach data sheets) Method of synchronizing: (Auto/Manual, make and type of relay etc.) Method of anti-islanding: (Details of scheme, relays to be used etc.) Method of generator control: (AVR, speed, power, PF etc., relays to be used) Other protection to be Applied: (O/C, E/F, over/under voltage, over/under frequency, reverse power etc.) Intended Recipient of Embedded Generation Output: (Own use, Overstrand Municipality Electricity Consumer, Overstrand Municipality Electricity) Recording of quality of supply devices List of regulatory approvals, requirements and normative references 3 : (Tick appropriate box or mark not applicable N/A) Electricity Regulation Act, Act 4 of 2006 and Electricity Regulation Amendment Act, Act 28 of 2007 Occupational Health & Safety Act, No. 85 of 1993 as amended South African Distribution Code (all parts) South African Grid Code (all parts) South African Renewable Power Plants Grid Code Overstrand Municipality Electricity Supply By-Law SANS 474 / NRS 057: Code of Practice for Electricity Metering SANS 10142- Parts 1 to 4: The wiring of premises (as amended and published) NRS 048: Electricity Supply Quality of Supply NRS 097-1 : Code of Practice for the interconnection of small scale embedded generation to electricity distribution networks: Part 1 MV and HV NRS 097-2 : Grid interconnection of small scale embedded generation: Part 2: Small scale small scale embedded generation Clearance by other Municipal departments FUNCTION SECTION COMMENTS NAME SIGNATURE DATE Zoning/subdivision Town Planning Building structure plans Building Department Noise impact & air pollution Environmental Services Note: 1. Electricity Services will require prior approval from these departments. Applications to connect to the municipal electrical grid will not be considered until all relevant approvals have been obtained. 2. Photovoltaic (PV) SSEG applications will require approval from only Town Planning and Building Departments if: a) Roof top installations: PV panel(s) in its installed position projects more than 1.5m, measured perpendicularly, above the roof and/or projects more than 600mm above the highest point of the roof; b) Installations on the ground: PV panel(s) in its installed position projects more than 2.1 metres above the natural/finished ground level. 3 Note: It is the responsibility of the ECSA registered professional engineer/technologist to ensure compliance through their professional sign-off of the installed system in Appendix 1 SSEG Installation Commissioning Report.

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 4 Installer Details Installer: Accreditation/qualification: Professional registration: Address: Contact person: Telephone no: Work: Cell: Fax: E-mail address: Additional Comments Reg. No. Postal code: Signed ( Installer): (Note: Sign-off by an ECSA registered professional is optional at application stage, however it is recommended that an ECSA registered professional engineer or professional technologist that is familiar with the technical details of the intended generation technology, complete this application form) ECSA registered professional Name & Surname Registration number: Registration category: Additional Comments Signed ( ECSA registered professional): I request the Overstrand Municipality Electro Technical Department to proceed with the review of this small scale embedded generation interconnection application. I understand that: I will have to pay for both in-house and outsourced engineering studies conducted as part of this review, should these be required; and A quotation for such work will be provided beforehand, giving me the opportunity to cancel or modify the application should I wish to do so. I further consent to Overstrand Municipality providing this information to the National Transmission Company and other Distributors as required. Application completed by: Name & Surname: Title: Signed (Applicant): Signed ( Property Owner): Submit completed form to: Electro Technical Department

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 5 FOR OFFICE USE Date Application Received: Application Reference No: Further Information Required: (e.g. Competent Person detail required i.t.o. Occupational Health and Safety Act, General Machinery Regulations: Supervision of Machinery, Section 2) YES NO Date Received: Load Flow Analysis Required: YES NO Date Complete: Fault Level / Protection Grading Study Required: YES NO Date Complete: Approved in Principle: YES NO Date Applicant Advised: Copy of COC received: YES NO Date COC received: Installation inspected by Municipality: YES NO Date inspected: Smart meter installed and programmed: YES NO Date installed and programmed: Installation certified for commissioning: YES NO Date applicant informed that installation may be commissioned: Installation inspected by: Electrician (Name): _ Staff no: Signature Electrician:

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 6 ANNEXURE A Responsibilities of Embedded Generators to Overstrand Municipality, Electro Technical Department 1 The Embedded Generator shall enter into a connection agreement with Overstrand Municipality Electricity (Distributor) before connecting onto the Distribution System. 2 The Embedded Generators shall ensure that the reliability and Quality of Supply complies with the terms of the connection agreement. 3 The Embedded Generator shall comply with the Distributor s protection requirement as well as protection of own plant against abnormalities, which could arise on the Distribution System. 4 The Embedded Generator shall be responsible for any dedicated connection costs incurred on the Transmission System or Distribution System as a result of connection of the Embedded Generation facility to the Distribution System. 5 The Embedded Generator shall be responsible for synchronizing the generating facility to the Distribution System within pre-agreed settings. Connection Point Technical Requirements 1 The Embedded Generator shall be responsible for the design, construction, maintenance and operation of the equipment on the generation side of the connection point. 2 The Embedded Generator shall be responsible for the provision of the site required for the installation of the Distributor s equipment required for connecting the generating facility. 3 The technical specifications of the connection shall be agreed upon by the participants based on the Distribution System Impact Assessment Studies. 4 A circuit breaker and visible isolation shall be installed at the connection point to provide the means of electrically isolating the Distribution System from the generating facility. 5 The Embedded Generator shall be responsible for the circuit breaker to connect and disconnect the generator plant. 6 The location of the circuit breaker and visible isolation shall be decided upon by the participants. Protection Requirement for Embedded Generators General Protection Requirements 1 The Embedded Generator s protection shall comply with the requirements of Overstrand Municipality. 2 Additional features including inter-tripping and generator plant status to be agreed upon by the participants. 3 The protection schemes used by the Embedded Generator shall incorporate adequate facilities for testing and maintenance. 4 The protection scheme shall be submitted by the Embedded Generator for approval by Overstrand Municipality Electro Technical Department. Specific Protection Requirements 1 Phase and Earth Fault Protection (a) The protection system of the Embedded Generator shall fully coordinate with the protective relays of the Distribution System. (b) The Embedded Generator shall be responsible for the installation and maintenance of all protection relays at the connection point. 2 Over/under Voltage and over/under Frequency Protection The Embedded Generator shall install over/under voltage and over/under frequency protection to disconnect the generating facility under abnormal network conditions as agreed between the Distributor and the Embedded Generator. 3 Faults on the Distribution System The Embedded Generator shall be responsible for protecting its generation facility in the event of faults and other disturbances arising on the Distribution System. 4 Islanding (a) The Embedded Generation facility shall be equipped with loss of mains detection protection system to prevent the generator from being connected to a de-energized Distribution System. The Distributor shall take reasonable steps to prevent closing circuit breakers onto an islanded network. (b) For unintentional network islanding, the Embedded Generator and the Distributor shall agree on methodology for disconnecting and connecting the Embedded Generator.

APPLICATION FOR THE INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Page 7 Quality of Supply Requirements 1 Frequency Variations The Embedded Generation facility shall remain synchronized to the Distribution System while the network frequency remains within the agreed frequency limitations at all time. 2 Power Factor The power factor at the connection point shall be maintained within the limits agreed upon by Overstrand Municipality Electro Technical Department. 3 Fault Levels The Embedded Generator shall ensure that the contractually agreed fault level contribution from the generation facility shall not be exceeded at any time. Telemetry 1 The Embedded Generator shall have the means to remotely report any status change of any critical function that may negatively impact on the Quality of Supply of the Distribution System. Operational Responsibilities of Embedded Generators 1 The Embedded Generator shall ensure that its generating units are operated within the capabilities defined in the Connection Agreement entered into with the Distributor. 2 The Embedded Generator shall reasonably cooperate with the Distributor in executing all the operational activities during an emergency generation condition. 3 The Embedded Generator shall assist the Distributors in correcting Quality of Supply problems caused by its equipment connected to the Distribution System. 4 All customers must declare any co-generating plant (whether licensed or not) and specify the interlocking mechanism to prevent inadvertent parallel operation with the Distributor s network. 5 Embedded Generators shall have the required protection to trip in the event of a momentary supply loss causing an island condition to prevent paralleling out of synchronism due to auto-reclose functionality on the Distributor s Network. Fault Reporting and Analysis/Incident Investigation 1 The Embedded Generators shall report the loss of generation (as agreed by the participants) to the Distributor within 15 minutes of the event occurring. Notice of the intention to reconnect such shall be given with at least 15 minutes advance notice to enable the Distributor to take any necessary action required. Outage Scheduling and co-ordination 1 Embedded Generators with the maximum capacity greater than 1MW shall furnish the Distributor with information on planned outages in order for the Distributor to properly plan, and coordinate its control, maintenance and operation activities. Standards to abide by 1 NRS 097 :GRID INTERCONNECTION FOR EMBEDDED GENERATION 2 NRS 048 :ELECTRICITY SUPPLY: QUALITY OF SUPPLY Additional Requirements 1 Where the 11 kv side of the generator transformer is Star, an NER must be fitted. 2 Where the 11 kv side of the generator transformer is Delta, an NECR must be fitted.