HORIZONTAL SPLIT CASING PUMP

Similar documents
OPERATION & MAINTENANCE MANUAL PORTABLE SUBMERSIBLE PUMP

Ni-HARD SUBMERSIBLE PUMP

OPERATION & MAINTENANCE MANUAL POLDER PUMP. A Mark of Quality

DEWATERING PUMP. Instruction, Installation, Operation and Maintenance Manual. A Mark of Quality. ISO 9001 Certified Company

HORIZONTAL SPLIT CASING PUMP

SUBMERSIBLE SEWAGE PUMP

POLDER PUMPSET. ISO 9001:2008 Certified Company. A Mark of Quality

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Agri KAM INSTALLATION, OPERATION AND MAINTENANCE MANUAL. A View of KBL Dewas Manufacturing Plant. A Kirloskar Group Company KIRLOSKAR BROTHERS LIMITED

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

SAM TURBO INDUSTRY LIMITED

PROCESS PUMPS (INDIA) PVT LTD

FOR ROTARY TYPE TWIN GEAR. Pump Type: HGSX

Series Base mounted pump. Installation and operating instructions

PROCESS PUMPS (INDIA) PVT LTD

PROCESS PUMPS (INDIA) PVT LTD

Series Base mounted pump. Installation and operating instructions

NSR PUMPS Installation, Operation and Maintenance Manual

INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE DSM (STANDARD)

INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE DB

NECO Pumping Systems

INSTALLATION AND SERVICE INSTRUCTIONS FOR 1008 AND 1010 SERIES PUMPS

SUMMIT PUMP. Model DSR Single Stage, Double Suction Pumps Installation, Operation, and Maintenance Manual

PROCESS PUMPS (INDIA) PVT LTD

OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD.

Specifications Information and Repair Parts Manual , , , &

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

SERIES PC INSTRUCTION AND OPERATION MANUAL

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODELS 3341 AND 3344 END SUCTION PUMPS

Designed to Meet Your Specifications! USER MANUAL INSTALLATION OPERATION MAINTENANCE

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

GENERAL DIMENSIONS OF SMF PUMPS. Capacity upto 7,000 m /hr Head upto 45 m. Range :

Model 3656/3756. Installation, Operation and Maintenance Instructions. Table of Contents. Owner s Information

The ELM Series Slurry Pump Installation and Operating Manual

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

ISO 9001 CERTIFIED COMPANY INDUSTRIAL PUMPS. Installation & Operational Manual For BACK-PULL-OUT PUMP

Enriching Lives T E C H N I C A L M A N U A L DV-40/DV-50 SERIES. KIRLOSKAR BROTHERS LIMITED A Kirloskar Group Company TM 1002

900 Series Split Case Fire Pump Systems

T E C H N I C A L M A

PROCESS PUMPS (INDIA) PVT LTD

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODEL 3310

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

1750 RPM Centrifugal Pumps

General Service Centrifugal Pump. 3. Designation. 1. Application. 2. Design. 4. Operating Data. Operating Instructions Nº A

INSTALLATION AND OPERATING INSTRUCTIONS

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

Wilo SCP Base Mounted Split Case Pumps Installation and operating instructions

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

Installation and Service Instructions 1008 & 1010 Size Pumps

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax:

KEEN INDUSTRIAL PUMP CO. Inc.

INSTALLATION AND OPERATING INSTRUCTIONS

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

WARMAN PUMPS ASSEMBLY, OPERATING AND MAINTENANCE INSTRUCTIONS PART 2C SERIES A SOLUTION PUMPS TYPE S AND SH PC2C

1750 RPM Centrifugal Pumps

INSTRUCTIONS ON INSTALLATION, OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE RKB

MET-PRO. Fybroc series 1530 horizontal pumps. Global Pump Solutions

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

INSTRUCTION MANUAL. Portable Greasing System S1180, REV C GS

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

General Service Centrifugal Pump. 1. Application. 3. Designation. 2. Design. 4. Operating Data. Operating Instructions Nº A2744.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS. Mr. Proprietor

HAYWARD GORDON ULC Process Pumps & Mixers

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Series HSC and HSC-S Base Mounted Centrifugal Pumps

AJAX PUMPS PUMPS AJAX. ~Pli~r. on s SYDNEY BRISBANE ADELAIDE PERTH. ~Pli~[ ODS ~ISTON PURPOSES

Medium and high pressure pumps

Penn Valley Pump Company Design Information for Double Disc Pumps

END SUCTION CENTRIFUGAL PUMPS

Installation & Operating Manual

MAINTENANCE AND REPAIR INSTRUCTIONS

GROOVED END FLO-TREX COMBINATION VALVE

INSTRUCTION MANUAL AC2516 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Series 1580 In-Line Mounted Centrifugal Fire Pumps

INSTRUCTION MANUAL AC8585 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE Series Base Mounted Centrifugal Fire Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

MET-PRO. Fybroc series 1600 horizontal pumps. Global Pump Solutions I N S T A L L A T I O N M A N U A L

8000 / 10,000 / 12,000


END SUCTION CENTRIFUGAL PUMPS

INSTRUCTIONS Installation Operation Repair

series 1500 horizontal pumps

Ghaziabad. Site No. 1, NO. REV. NO. Page 1

SUMMIT PUMP. Model SP Single Stage, Horizontal Slurry Pump, Installation, Operation, and Maintenance Manual

INSTRUCTION MANUAL SHORT BEARING FRAME, STUFFING BOX

Installation, Operation and Maintenance Instructions

Service Manual #40. Installation and Service Instructions 4000 Series Pumps

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Installation and Service Instructions 1012, 1014, 1015, & 1017 Size Pumps

SINGLE PHASE CENTRIFUGAL MONOBLOCK ACS 11 & 15 SERIES INSTALLATION & SPARE PARTS MANUAL MANUFACTURED BY: AQUASUB ENGINEERING - UNIT II

INSTRUCTIONS ON INSTALLATION OPERATION AND MAINTENANCE FOR KIRLOSKAR PUMP TYPE SHM

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

VSCP Vertical Suspended Column Pump Operation & Maintenance Manual

GUIDE TO THE INSTALLATION OF SPP PUMPS

SUMMIT PUMP Horizontal End Suction Pump Close Coupled and Frame Mounted

OPERATING INSTRUCTIONS ZDX 7-1/2AS

OPERATING INSTRUCTIONS ZDX 1/12CS

Transcription:

OPERATION & MAINTENANCE MANUAL HORIZONTAL SPLIT CASING A Mark of Quality

CROSS SECTION DRAWING No. DESCRIPTION MATERIAL 01 1/4 BSP PLUG BRASS 02 LOWER HOUSING C. I. IS-210, FG260 03 IMPELLER C. I. / G. M. / S. S. 04 NECK RING C. I. / G. M. 05 BUSH C. I. 06 LENTREN RING PLASTIC 07 RING NUT M. S. 08 1/4 GREASE CUP / NIPPLE BRASS 09 BALL BEARING (N.D.E.) STD. 10 GLAND PACKING STD. 11 IMPELLER KEY EN-8 12 HARDWER M.S. 13 FIBER RING FIBER + WOOD 14 BALL BEARING (D.E.) STD. 15 COUPLING KEY EN-8 16 SHAFT EN-8 17 BEARING HOUSHING C. I. IS-210, FG260 18 BEARING COVER C. I. IS-210, FG260 19 BEARING COLLAR C. I. IS-210, FG260 20 GLAND COVER C. I. IS-210, FG260 21 SLEEVE C. I. / S.S. / G.M. 22 UPPER CASING C. I. IS-210, FG260 23 TAPER PIN S. S. 2008 MBH Pumps (Gujarat) Pvt. Ltd. 1

GENERAL Figure-1 1. MBH make horizontal split casing type pumps with suction and discharge nozzles and their supporting feet integrally cast in the lower half casing. This construction allows removal of the rotating unit for inspection and repairs by just removing upper half casing, and without disturbing align ment, pipe connection or prime movers. 2. Pumps when properly installed and given due care in operation and main tenance should operate satisfactorily for a long period. 3. When the pump is received, before the actual use of the pump, it should be inspected and located in a dry place. The coupling should be rotated periodically to prevent pitting of bearing surfaces. 4. All split casing pump are designated by serial number, model number, size and type. This information is stamped on an identification plate which is mounted on the pumps. ANGULAR MISALIGNMENT INSTALLATION INSTRUCTION 1. The pump should be installed as near to the source of liquid as possible. 2. Make sure there is a suitable power source available for the pump driver. The motor driven electrical characteristics should be identical to those shown on motor data plate. 3. The foundation should be substantial to reduce vibration and rigid enough to avoid any twisting or misalignment. 4. The base frame of the pump must be bolted and ground to a rigid foundation of concrete block. 5. Shaft alignment must be checked again after the final position of the pump unit. 6. Maintain a gap of 2-3 mm between the drive and driven jaw of coupling. 7. Provide suitable earthing and tripping device for electrical equipments. ALIGNMENT PROCEDURE There are two forms of misalignment : a) Angular Shaft with axes concentric but not parallel. b) Parallel Shaft with axes parallel but not concentric. To check for angular alignment insert a pair of inside calipers or taper gauge at four points at 30 degree intervals around the coupling. Angular alignment is achieved when the measurements show that all points around the coupling faces are within 0.05 mm of each other. (See Fig 1) To check for parallel alignment, place a straight edge across both coupling rims at the bottom and at both sides ( See Fig 1). Parallel alignment is achieved when the straight edge rests evenly on the coupling rim at all position. Alignment adjustments can be made by shimming under the driver mounting feet. After each adjustment, it is necessary to recheck all features of the alignment. PARALLEL MISALIGNMENT 2008 MBH Pumps (Gujarat) Pvt. Ltd. 2 2008 MBH Pumps (Gujarat) Pvt. Ltd. 3

SUCTION AND DISCHARGE PIPING Figure-2(B) SUCTION PIPING When installing the pump piping, make sure that the following precautions are taken : 1. Piping should always be run to the pump. Do not move pump to pipe. This could make final alignment impossible. 2. Both suction and discharge piping should be supported independently and close to pump so that no strain is transmitted to the pump when flange bolts are tightened. Use pipe hangers or other supports at necessary intervals to provide support. When expansion joints are used in the piping system, they must be installed beyond the piping supports close to the pump. 3. It is advisable to increase the size of both suction and discharge pipes at the pump connection to decrease the loss of head from friction. 4. Install piping as straight as possible, avoid unnecessary bends. Where necessary, use 45 degree or long sweep 90 degree fitting to decrease friction losses. 5. Make sure that all piping joints are air tight. Provide pipe expansions below when hot fluid is to be pumped. Where reducers are used, eccentric reducers are to be fitted in suction lines and straight taper reducers in discharge and vertical lines (See Fig 2A, 2B, 2C). Misuse of reducers may cause the formation of air pocket in the pipe and thus preventing the correct operation of the pump. 6. The suction pipe should be as short and direct as possible. Where suction lift is not very high, it is advisable to use a foot valve. Horizontal suction line must have a gradual rise to the pump. 7. The discharge pipe is usually preceded by a non-return valve or check valve and a discharge gate valve (See Fig 2D). The check valve is to protect the pump from excessive back pressure and reverse rotation of the unit and to prevent back flow into the pump in case of stoppage or failure of the driver. The discharge valve is used in priming starting and shutting down the pump. Figure-2(A) SUCTION PIPING RECOMMENDED Figure-2(C) NOT RECOMMENDED RECOMMENDED Figure-2(D) DISCHARGE PIPING NOT RECOMMENDED 2008 MBH Pumps (Gujarat) Pvt. Ltd. 4 2008 MBH Pumps (Gujarat) Pvt. Ltd. 5

BEFORE STARTING INSTRUCTION 1. Check if the pump rotates freely by hand. 2. Check the alignment between pump and motor. 3. Fill the pump body and suction pipelines with liquid before starting. 4. Check the correct rotation as shown on the pump volute. 5. Check up grease in the grease lubrication or oil level for oil. 6. Valve on the delivery side should be closed. 7. The cock of pressure gauge should be closed. STARTING INSTRUCTION 1. Open all valve in suction line fully. 2. Start the pump and let the prime mover pick up its full speed. 3. Open the valve on delivery side slowly. 4. Open the cock for pressure gauge connection. 5. Set the delivery valve at designed duty point. (As per name plate) CHECK POINT DURING RUNNING 1. The flow of sealing liquid (if external liquid is provided for sealing purpose) should be uninterrupted. 2. In gland packing arrangement pumps, there should be constant drip of liquid from gland packed arrangement when the pump is running. 3. Head and capacity developed by the pump is as specified. 4. Power consumption is within limit. 5. There should be no mechanical friction in the pump. 6. Check the suction and discharge gauge reading. 7. Check the vibration and noise of the pump unit. LUBRICATION DETAILS In the regreasing period bearings should be repacked with a high quality, ball and rollar bearing grease free from resin and acid, not liable to harden or crumble and processing rust preventive properties. The regreasing interval depends upon the operating speed of the unit. Pump Operating Speed Regreasing Interval 1450 RPM 4000 Hours 2000 RPM 3000 Hours Recommended Grease Specifications. For 1450 RPM IOCL SERVOGEM - 3 or equivalent For 2000 RPM IOCL SERVOGEM - 2 or equivalent 2008 MBH Pumps (Gujarat) Pvt. Ltd. 6 No Liquid Delivered Pump does not deliver rated capacity Pump does not develop rated pressure Pump loses liquid after starting Pump operates for a short time, then stops Pumps operate while hots too much power Motor consumes Vibration Cavity formation - noise Pump Bearing Overheat TROUBLE SHOOTING CHART HORIZONTAL SPLIT CASING Pump not primed / lack of prime / incomplete priming Loss of prime Suction lift too high Discharge head too high Speed too low Wrong direction of rotation Impeller plugged up / Impeller partially plugged Air leak in suction Air leak in stuffing box Insufficient net inlet head Damage impeller & wrong size of impeller Defective packing Foot valve too small or partially obstructed Inlet pipe not submerged enough Impeller too small Obstruction in liquid passages Air or gas in liquid Head lower than rating Liquid heavier than rating Viscosity of liquid greater than rating Shaft bent Bearing warn off Misalignment of pump and driver Defects in motor Voltage and/or frequency lower than rating Rotor bearing worn out Speed too high Foundation not rigid Lubrication oil / grease dirty, contaminated 2008 MBH Pumps (Gujarat) Pvt. Ltd. 7

GUARANTEE HORIZONTAL SPLIT CASING The Pump is guaranteed against defects in material and workmanship under normal use and service for the period of 15 months from the date of purchase or 12 months from the date of commissioning, whichever is less. The General terms and conditions for above guarantee are : 1. The guarantee is valid only if the pump is operated strictly as per the instructions given in the user guide attached herewith. 2. Our obligation is limited to rectifying; repairing or replacing defective items, ex-works/service station/authorized Service Center, provided the purchaser has given immediate written notice. The equipment for repairs should be returned to us duly packed, on pre-paid freight basis. Model : Pump Sr. No. Customer Name : Address : Date of Purchage / Bill No.: Dealers Name : Signature : Date : Plot No. 14, G.I.D.C. Naroda Industrial Estate, Ahmedabad - 382 330, India. Phone : 079-2282 3066, 2282 1018 Fax : 079-2282 1511 E-mail : mbhpumpsad1@sancharnet.in Website : www.mbhpumps.com 2008 MBH Pumps (Gujarat) Pvt. Ltd. 8

Our Product Range CENTRIFUGAL TYPE HC PORTABLE SUBMERSIBLE SUBMERSIBLE SEWAGE POLDER / DEWATERING SELF PRIMING CENTRIFUGAL ISO 9001:2000 Certified Company Plot No. 14, G.I.D.C. Naroda Industrial Estate, Ahmedabad - 382 330, India. Phone : 079-2282 3066, 2282 1018 Fax : 079-2282 1511 E-mail : mbhpumpsad1@sancharnet.in Website : www.mbhpumps.com A Mark of Quality 12/2008 marg