LISTED TECHNICAL GUIDE STELLAR 2000 TM

Similar documents
TECHNICAL GUIDE LISTED

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION

Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: GHD, GFD, GFA, GNA, GUA & GHA CFM 2-5 TON COILS

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

SPLIT SYSTEM HEAT PUMP 12 SEER

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

R-22, 13 SEER 60 Hertz

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60

LISTED TECHNICAL GUIDE

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH)

DESCRIPTION FEATURES

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

SINGLE PACKAGE HEAT PUMPS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DESCRIPTION FEATURES

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION

N4A6. Product Specifications

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

WCA4**4. Product Specifications

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

CSA6. Product Specifications. SoftSound SXC 2600

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

HCH6. Product Specifications

P5RF Series Single Packaged Air Conditioner Single Phase

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

10+ SEER - AIR CONDITIONER

R4H4. Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

PHB SERIES 7-1/2 and 10 TON

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

TSA6. Product Specifications. SmartComfort TXC 5600

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

ELITE SERIES R-410A Ready - Multi-Position

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

10AC DIPLOMAT SERIES RFC SYSTEMS

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

N4A4 C. Product Specifications

10+ SEER - AIR CONDITIONER

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz

Q7RE Series Single Packaged Heat Pump, Single Phase

CAC SERIES 12-1/2 Thru 20 Ton

Transcription:

E T I I I R P I T I O I N G TECHNICAL GUIDE STELLAR 2000 TM SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: H*DB018 THRU 060 (1 THRU 5 NOMINAL TONS, 1 PH) H*DB036 THRU 076 (3 THRU 6-1/3 NOMINAL TONS, 3 PH) This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001. U R A C T MA N U F R C E UN I R T I C ER T A R I A RY F F I E D E Q U I C A T T S A T ON Certification applies only when the complete system is listed with ARI. Models 018-048 Model 060 LISTED Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. O T M E N S A R I AI E CT N D A R R - C D AS ONDI ON S 2 C 1 0 OM P NI N G OF L Y W IT H DESCRIPTION FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21024-006 Rev. D (0403) The HDB Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custommatched with one of YORK's complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system. Electric heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces. WARRANTY Single Phase Units: 5-year limited parts warranty. 5-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - Cabinet is made of powder painted steel over pre-primered steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and automotive quality finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Both quick connect and sweat connect models are available. Both service valves are firmly affixed to the unit. The sweat unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor- bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls, and the molex plug in the control box connecting the condenser fan make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.

Physical and Electrical Data - 1 Phase H4DB018 H4DB024 H4DB030 H4DB036 H5DB042 H5DB048 H4DB060 Unit Supply Voltage 208/230-1-60 Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 13.0 15.2 16.9 23.0 27.2 31.9 37.6 Max. Overcurrent Device Amps 2 20 25 25 35 40 50 55 Compressor Type 3 Recip Recip Recip Recip Recip Scroll B Scroll B Compressor Amps Rated Load 9.7 11.5 12.8 17.1 20.5 24.4 28.8 Locked Rotor 54 60 68 86 120 140 165 Crankcase Heater No No NOo Yes Yes No No Fan Motor Amps Rated Load 0.5 0.8 0.8 1.6 1.6 1.4 1.6 Fan Diameter Inches 18 18 18 18 18 18 24 Fan Motor Rated HP 1/12 1/8 1/8 1/4 1/4 1/4 1/4 Nominal RPM 1100 1075 1075 1100 1100 1100 850 Nominal CFM 1850 1950 1950 2150 2200 2200 3000 Face Area Sq. Ft. 9.4 9.4 11.3 11.3 14.1 14.1 20.0 Coil Rows Deep 1 1 1 1 1 1 1 Fin / Inches 16 16 18 18 18 16 18 Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Unit Charge (Lbs. - Oz.) 4 3-14 3-10 4-7 4-9 5-11 6-0 8-0 Charge Per Foot, Oz. 0.68 0.68 0.68 0.68 0.70 0.70 0.70 Operating Weight Lbs. 124 134 135 140 155 176 210 PHYSICAL AND ELECTRICAL DATA - 3 Phase H4DB H5DB H4DB H4DB H4DB H5DB H4DB H4DB H5DB H4DB 036 048 060 076 036 048 060 076 048 060 25 46 58 Unit Supply Voltage 208/230-3-60 460-3-60 575-3-60 Normal Voltage Range 1 187 to 253 432 to 504 517 to 633 Minimum Circuit Ampacity 15.2 19.0 21.6 25.4 8.1 9.7 10.8 12.8 7.5 8.6 Max. Overcurrent Device Amps 2 25 30 30 40 15 15 15 20 15 15 Compressor Type 3 Recip Scroll B Scroll B Scroll B Recip Scroll B Scroll B Scroll B Scroll B Scroll B Compressor Amps Rated Load 10.9 14.1 16.0 18.9 5.8 7.1 8.0 9.5 5.6 6.4 Locked Rotor 78 105 125 146 40 55 67 73 44 50 Crankcase Heater Yes No No No Yes No No No No No Fan Motor Amps Rated Load 1.4 1.4 1.6 1.8 0.8 0.8 0.8 1.0 0.5 0.6 Fan Diameter Inches 18 18 24 24 18 18 24 24 18 24 Fan Motor Rated HP 1/4 1/4 1/4 1/3 1/4 1/4 1/4 1/3 1/4 1/4 Nominal RPM 1100 1100 850 1100 1075 1075 850 1100 1075 850 Nominal CFM 2150 2150 3000 4200 2350 2150 3000 4200 2150 3000 Face Area Sq. Ft. 11.3 14.1 20.0 20.0 11.3 14.1 20.0 20.0 14.1 20.0 Coil Rows Deep 1 1 1 2 1 1 1 2 1 1 Fin / Inches 18 16 18 13 18 16 18 13 16 18 Liquid Line OD 3/8 3/8 3/8 1/2 3/8 3/8 3/8 1/2 3/8 3/8 Vapor Line OD 3/4 7/8 7/8 1-1/8 3/4 7/8 7/8 1-1/8 7/8 7/8 Unit Charge (Lbs. - Oz.) 4 4-9 6-0 8-0 14-0 4-9 6-0 8-0 14-0 6-0 8-0 Charge Per Foot, Oz. 0.68 0.70 0.70 0.70 0.68 0.70 0.70 0.70 0.70 0.70 Operating Weight Lbs. 140 176 210 300 140 176 210 300 176 210 1. Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with a superscript B are Bristol scrolls. All scrolls listed with a superscript C are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. 2 Unitary Products Group

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase OUTDOOR UNITS H4DB018 H4DB024 H4DB030 H4DB036 H4DB042 H5DB048 H4DB060 UNIT ORIFICE(S) 1 53, 55 59, 61 65, 67, 69 73, 75 73,78,81 81, 84 87, 90, 93 FACTORY CHARGE, LBS. - OZ. 3-14 3-10 4-7 4-9 5-9 6-0 8-0 INDOOR COIL COIL ORIFICE 2 SYSTEM ORIFICE + ADDITIONAL CHARGE, OZ. G1FA/G1UA024S14, 17 59 53 + 2 59 + 2 - - - - - G1FA/G1UA030S14 65 57 + 4 57 + 4 67 + 0 - - - - G1FA/G1UA036S14, 17, 21 73-59 + 6 67 + 2 73 + 0 - - - G1FA/G1UA048S17 84 - - - 75 + 14 81 + 0 - - G1FA/G1UA048S21 84 - - - 75 + 21 81 + 5 84 + 6 - G1FA/G1UA060S21, 24 90 - - - - - 84 + 6 90 + 0 G1NA030S17H 57 55 + 4 57 + 7 - - - - - G1NA030S17K 63 - - 67 + 4 - - - - G1NA036S17J 67 - - - 73 + 2 - - - G1NA036S21C 67 - - - 73 + 2 - - - G1NA048S21D 78 - - - 75 + 8 78 + 3 84 + 0 - G2FD024(S,H)14, 17 61 57 + 4 55 + 4 - - - - - G2FD030(S,H)17 65 57 + 6 59 + 6 67 + 2 - - - - G2FD035(S,H)14 65 57 + 6 59 + 5 67 + 0 73 + 0 - - - G2FD036(S,H)17 75-59 + 10 67 + 6 73 + 3 - - - G2FD036(S,H)21 75-59 + 10 67 + 8 73 + 5 - - G2FD042(S,H)21 78 - - - 75 + 8 81 + 1 - - G2FD046(S,H)17 78 - - - 73 + 7 81 + 0 84 + 0 - G2FD048(S,H)21, 24 84 - - - 75 + 20 81 + 8 84 + 3 - G2FD060(S,H)24 90 - - - - 81 + 13 84 + 6 90 + 0 G2FD061H24 90 - - - - - - 90 + 5 G1HD024 59 55 + 5 59 + 18 - - - - - G1HD036 69-57 + 11 65 + 7 69 + 22 - - - G1HD048 81 - - - 75 + 14 78 + 5 81 + 2 - G1HD060 93 - - - - - 84+ 9 93 + 0 F2RP018 53 53 + 0 - - - - - - F2RC024 61 53 + 2 59 + 2 - - - - - F2RC030 65 - - 67+ 0 - - - - F2RC036 73 - - 67 + 2 73 + 0 - - - F2RC/F2RP/FP024 61-59 + 4 - - - - - F2RP/FP030 65-59 + 6 67 + 2 - - - - F2RP/FP036 75 - - - 75 + 6 - - - F2FP040 63-57 + 15 - - - - - F2RP/FP042 78 - - - 75 + 8 78 + 3 - - F2FP045 78 - - - 78 + 25 - - - F2FP048 84 - - - - 78 + 11 84 + 6 - F2FP060 90 - - - - - 84 + 8 90 + 0 FOOTNOTES: 1. These orifices are packed in the instruction/warranty packet of each outdoor unit. 2. These orifices are factory-mounted in the flow control device of each indoor coil. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and the additional charge required for the specific evaporator coil in the system using the table above: 3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge=Base Charge (as shipped) +adder for evaporator +adder for line set. 5. If the orifice in the evaporator was changed verify the evaporator nameplate has been marked with the correct orifice size. Unitary Products Group 3

Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase OUTDOOR UNITS H*DB036 H*DB048 H*DB060 H*DB076 UNIT ORIFICE(S) 1 73, 75 81,84 90, 93 - FACTORY CHARGE, LBS. - OZ. 4-9 6-0 8-0 14-0 INDOOR COIL COIL ORIFICE 2 SYSTEM ORIFICE + ADDITIONAL CHARGE, OZ. G1FA/G1UA048S17 84 75 + 14 - - - G1FA/G1UA048S21 84 75 + 21 84 + 6 - - G1FA/G1UA060S21, 24 90-84 + 6 90 + 0 - G1NA036S17J 67 73 + 2 - - - G1NA036S21C 67 73 + 2 - - - G1NA048S21D 78 75 + 8 84 + 0 - - G2FD035(S,H)14 65 73 + 0 - - - G2FD036(S,H)17 75 73 + 3 - - - G2FD036(S,H)21 75 73 + 5 - - - G2FD042(S,H)21 78 73 + 8 - - - G2FD046(S,H)17 78 73 + 7 84 + 0 - - G2FD048(S,H)21, 24 84 75 + 20 84 + 3 - - G2FD060(S,H)24 90-84 + 6 90 + 0 - G2FD061H24 90 - - 90 + 5 - G1HD036 69 69 + 22 - - - G1HD048 81 75 + 14 81 + 2 - - G1HD060 93-84 + 9 90 + 0 - F2RC/FC036 73 73 + 0 - - - F2RP/FP036 75 75 + 6 - - - F2RP/FP042 78 75 + 8 - - - F2FP045 78 78 + 25 - - - F2FP048 84-84 + 6 - - F2FP060 90-84 + 8 90 + 0 - K4EU090 - - - - +0 FOOTNOTES: 1. These orifices are packed in the instruction/warranty packet of each outdoor unit. 2. These orifices are factory-mounted in the flow control device of each indoor coil. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. 5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size. 4 Unitary Products Group

COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL 1 ELECTRIC 2 RATED NET MBH SEER SEER W HEAT. KW CFM W/O TXV + TXV 3 EER TOTAL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD H4DB018 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 650 18.8 13.9 10.30-9.25 H4DB024 H4DB030 H4DB036 H5DB042 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 810 24.8 18.4 10.50-9.75 N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 800 25.0 18.5 10.60-10.05 N1AHB1206 5,8,10,15,19 17 G2FD030(S,H)17 1000 29.0 21.5 10.60-9.90 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1000 30.0 22.2 12.20-10.85 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1200 35.6 26.3 10.20-9.40 N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1200 36.6 27.1 10.40-9.55 N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1400 39.5 29.2 10.00-9.00 N1AHC1606 5,8,10,15,20 21 G2FD046(S,H)21 1450 40.0 29.6 10.00-9.00 N1AHD2006 8,10,15,20,25,30 24 G2FD048(S,H)24 1450 40.5 30.0 10.40-9.30 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1600 48.5 36.4 10.40-10.00 H5DB048 N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1600 48.5 36.4 10.40-10.00 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1600 49.0 36.8 10.60-10.20 H4DB060 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1950 57.5 42.6 10.00-9.55 3 PH 10 SEER AC / N1VS - VARIABLE SPEED N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 36.0 26.6 10.70-9.70 H4DB036 N1VSB12 10,15,18 17 G2FD046(S,H)17 1200 36.6 27.1 11.00-10.00 N1VSC16 10,15,18 21 G2FD048(S,H)21 1200 37.6 27.8 11.60-10.30 H5DB048 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1630 49.0 36.8 10.80-10.25 H4DB060 N1VSD20 10,15,18,30 24 G2FD061H24 1600 58.0 42.9 10.75-9.80 1 PH 10 SEER AC / N1VS - VARIABLE SPEED H4DB018 N1VSB12 10,15,18 17 G2FD024(S,H)17 650 19.2 14.2 11.35-10.25 H4DB024 N1VSB12 10,15,18 17 G2FD024(S,H)17 870 25.6 18.9 11.80-11.05 N1VSB12 10,15,18 17 G2FD036(S,H)17 870 26.4 19.5 12.00-11.25 N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 36.4 26.9 10.80-9.80 H4DB036 N1VSB12 10,15,18 17 G2FD046(S,H)17 1200 37.0 27.4 11.10-10.10 N1VSC16 10,15,18 21 G2FD048(S,H)21 1200 38.0 28.1 11.70-10.40 H5DB042 N1VSC16 10,15,18 21 G2FD048(S,H)21 1430 41.0 30.3 11.00-9.90 H5DB048 H4DB060 H4DB018 H4DB024 N1VSC16 10,15,18 21 G2FD048(S,H)21 1600 49.0 36.8 11.00-10.45 N1VSD20 10,15,18,30 24 G2FD048(S,H)24 1600 49.5 37.1 11.05-10.65 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1630 49.0 36.8 10.80-10.25 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1980 59.5 44.0 11.10-10.65 N1VSD20 10,15,18,30 24 G2FD061H24 1980 59.5 44.0 11.20-10.55 1 PH 10 SEER AC / F2RP / RC / FP / FC F2RC/FC024 5,8,10 18-650 18.5 13.7 10.50-9.10 F2RP/FP018 2,5,8 18-650 18.0 13.3 10.00-9.00 F2RC/FC024 5,8,10 18-750 23.0 17.0 10.00-9.30 F2RP/FP024 5,8,10 18-750 23.8 17.6 10.20-9.10 F2RP/FP030 5,8,10,15 18-750 24.0 17.8 10.40-9.20 F2FP040 5,8,10,15 21-810 25.6 18.9 11.25-9.85 F2RC/FC030 5,8,10,15 18-1000 28.0 20.7 10.40-9.60 H4DB030 F2RC/FC036 5,8,10,15 21-1000 29.0 21.5 10.50-9.70 F2RP/FP030 5,8,10,15 18-1000 29.0 21.5 10.55-9.80 F2RP/FP036 5,8,10,15,19 21-1000 29.8 22.1 10.80 11.00 9.90 For Notes see Page 4. Unitary Products Group 5

COOLING CAPACITY - With Air Handler Coils (Continued) UNIT H4DB036 H5DB042 AIR HANDLER ELECTRIC 2 HEAT. KW W COIL 1 RATED CFM 1 PH 10 SEER AC / F2RP / RC / FP / FC (Continued) NET MBH TOTAL SENS. COOLING SEER W/O TXV SEER + TXV 3 EER F2RC/F2FC036 5,8,10,15 21-1200 35.4 26.2 10.10-9.35 F2RP/F2FP036 5,8,10,15,19 21-1200 36.8 27.2 10.50-9.65 F2RP/F2FP042 5,8,10,15 21-1200 37.0 27.4 10.50-9.60 F2FP045 5,8,10,15 24-1200 37.0 27.4 10.50-9.50 F2RP/F2FP042 5,8,10,15 21-1400 39.5 29.2 10.00-8.90 F2FP048 5,8,10,15,20,25 24-1400 40.0 29.6 10.00-9.00 F2FP048 5,8,10,15,20,25 24-1600 47.5 35.2 10.00-9.95 H5DB048 F2FP060 5,8,10,15,20,25 24-1600 48.0 35.5 10.00-9.85 H4DB060 F2FP060 5,8,10,15,20,25 24-1950 57.0 42.2 10.00-9.40 3 PH 10 SEER AC / F2RP / RC / FP / FC 4,5 F2RC/F2FC036 5,8,10,15 21-1200 35.0 25.9 10.00-9.25 H4DB036 F2RP/F2FP036 5,8,10,15,19 21-1200 36.4 26.9 10.40-9.55 F2RP/F2FP042 5,8,10,15 21-1200 36.6 27.1 10.40-9.50 H5DB048 F2FP048 5,8,10,15,20,25 24-1600 48.0 35.5 10.05-9.95 H4DB060 F2FP060 5,8,10,15,20,25 24-1950 57.0 42.2 10.00-9.40 3 PH SEER AC / K2EU H4DB060 K2EU060 10,16,25 36-1950 56.5 39.5 10.00-9.40 H4DB076 K2EU090 10,16,25,36 52-2550 76.6 53.6 - - 10.30 1 PH 10 SEER AC / M1HC H4DB018 M1HC018F01 0 40-460 16.8 12.4 10.30-9.60 H4DB024 M1HC024F01 0 40-830 24.2 17.9 11.00-11.10 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. 3. TXV = Use 1TV700 Series Kit. 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard. - = Not applicable 6 Unitary Products Group

COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils UNIT H4DB018 H4DB024 H4DB030 H4DB036S06 FURNACE** CFM RANGE W (MIN.-MAX.) 575 725 700 900 875 1125 1050 1350 For Notes see Page 6. 036-21024-006 Rev. D (0403) COOLING COIL RATED NET MBH SEER W/O TDR SEER + TDR EER CFM TOTAL SENS. W/O TXV W/O TXV 14,17 G1FA024S14,17 650 18.4 13.6 10.15-9.10 14 G1FA030S14 650 18.8 13.9 10.30-9.25 - G1HD024 650 18.9 14.0 10.30-9.30 17 G1NA030S17H 650 19.0 14.1 10.50-9.35 14,17 G1UA024S14,17 650 18.4 13.6 10.15-9.10 14 G1UA030S14 650 18.8 13.9 10.30-9.25 14,17 G2FD024(S,H)14,17 650 18.8 13.9 10.30-9.25 17 G2FD030(S,H)17 650 19.0 14.1 10.50-9.35 14 G2FD035(S,H)14 650 19.0 14.1 10.50-9.35 14,17 G1FA024S14,17 800 24.6 18.2 10.30-9.95 14 G1FA030S14 810 24.8 18.4 10.50-9.75 17,21 G1FA036S17,21 800 25.0 18.5 10.60-10.05 17,21 G1FA036S17,21 800 25.0 18.5-11.00 10.05 - G1HD024 810 23.2 17.2 10.25-9.35 - G1HD036 810 25.6 18.9 10.80-9.95 17 G1NA030S17H 810 24.4 18.1 10.20-9.85 14,17 G1UA024S14,17 800 24.6 18.2 10.30-9.95 14 G1UA030S14 810 24.8 18.4 10.50-9.75 17,21 G1UA036S17,21 800 25.0 18.5 10.60-10.05 17,21 G1UA036S17,21 800 25.0 18.5-11.00 10.05 14,17 G2FD024S14,17 810 24.8 18.4 10.50-9.75 17 G2FD030(S,H)17 800 25.0 18.5 10.60-10.05 14 G2FD035(S,H)14 800 25.0 18.5 10.60-10.05 17 G2FD036(S,H)17 800 25.4 18.8 10.70-10.20 14 G1FA030S14 1000 28.8 21.3 10.60-9.90 14 G1FA036S14 1000 29.0 21.5 10.80-10.00 17,21 G1FA036S17,21 1000 29.0 21.5 10.80-10.00 17 G1FA048S17 1000 30.0 22.2-11.00 10.20 - G1HD036 1000 29.4 21.8 10.70-9.95 17 G1NA030S17K 1000 29.4 21.8 10.60-10.05 14 G1UA030S14 1000 28.8 21.3 10.60-9.90 14 G1UA036S14 1000 29.0 21.5 10.80-10.00 17,21 G1UA036S17,21 1000 29.0 21.5 10.80-10.00 17 G1UA048S17 1000 30.0 22.2-11.00 10.20 17 G2FD030(S,H)17 1000 29.0 21.5 10.60-9.90 14 G2FD035(S,H)14 1000 29.0 21.5 10.75-9.70 17 G2FD036(S,H)17 1000 30.0 22.2 12.20-10.85 17 G2FD036(S,H)17 1000 30.0 22.2-10.90 9.95 21 G2FD036(S,H)21 1000 30.0 22.2-11.00 10.05 21 G2FD042(S,H)21 1000 30.0 22.2-11.00 10.10 17 G2FD046(S,H)17 1000 31.0 22.9 12.45-11.10 17 G2FD046(S,H)17 1000 30.0 22.2-11.00 10.05 14 G1FA036S14 1200 35.4 26.2 10.00-9.30 17,21 G1FA036S17,21 1200 35.4 26.2 10.00-9.30 21 G1FA048S21 1200 37.0 27.4-10.60 9.75 - G1HD036 1200 35.4 26.2 10.00-9.30 - G1HD048 1200 36.8 27.2 10.20-9.60 17 G1NA036S17J 1200 35.6 26.3 10.20-9.40 21 G1NA036S21C 1200 35.6 26.3 10.20-9.40 21 G1NA048S21D 1200 36.8 27.2 10.40-9.65 14 G1UA036S14 1200 35.4 26.2 10.00-9.30 17,21 G1UA036S17,21 1200 35.4 26.2 10.00-9.30 17 G1UA048S17 1200 37.0 27.4-10.55 9.70 21 G1UA048S21 1200 37.0 27.4-10.60 9.75 14 G2FD035(S,H)14 1200 35.2 26.0 10.00-9.35 17 G2FD036(S,H)17 1200 35.6 26.3 10.20-9.40 21 G2FD036(S,H)21 1200 36.8 27.2 10.30-9.50 21 G2FD042(S,H)21 1200 36.8 27.2 10.40-9.65 17 G2FD046(S,H)17 1200 36.6 27.1 10.40-9.55 21,24 G2FD048(S,H)21,24 1200 37.2 27.5-10.60 9.85 Unitary Products Group 7

COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils (Continued) UNIT H4DB036S25,4 6 H5DB042 H5DB048 H4DB060S06 H4DB060S25,4 6 FURNACE** CFM RANGE (MIN.-MAX.) 1050 1350 1225 1575 1400 1800 1700 2100 1700 2200 W COIL RATED CFM NET MBH TOTAL SENS. 14 G1FA036S14 1200 35.0 25.9 10.00-9.20 17,21 G1FA036S17,21 1200 35.0 25.9 10.00-9.20 17 G1FA048S17 1200 36.6 27.1-10.45 9.60 21 G1FA048S21 1200 36.6 27.1-10.50 9.65 - G1HD036 1200 35.0 25.9 10.00-9.30 - G1HD048 1200 36.4 26.9 10.10-9.60 17 G1NA036S17J 1200 35.2 26.0 10.10-9.30 21 G1NA036S21C 1200 35.2 26.0 10.10-9.30 21 G1NA048S21D 1200 36.4 26.9 10.30-9.55 14 G1UA036S14 1200 35.0 25.9 10.00-9.20 17,21 G1UA036S17,21 1200 35.0 25.9 10.00-9.20 17 G1UA048S17 1200 36.6 27.1-10.45 9.60 21 G1UA048S21 1200 36.6 27.1-10.50 9.65 14 G2FD035(S,H)14 1200 34.8 25.8 10.00-9.25 17 G2FD036(S,H)17 1200 35.2 26.0 10.10-9.30 21 G2FD036(S,H)21 1200 36.4 26.9 10.20-9.40 21 G2FD042(S,H)21 1200 36.4 26.9 10.30-9.55 17 G2FD046(S,H)17 1200 36.2 26.8 10.30-9.45 21,24 G2FD048(S,H)21,24 1200 36.8 27.2-10.50 9.75 21 G1FA048S21 1425 40.5 30.0 10.40-9.50 - G1HD048 1400 40.0 29.6 10.00-9.10 21 G1NA048S21D 1400 39.5 29.2 10.00-9.05 21 G1UA048S21 1425 40.5 30.0 10.40-9.50 21 G2FD042S21 1400 39.5 29.2 10.00-9.00 17 G2FD046S17 1450 40.0 29.6 10.00-9.00 21,24 G2FD048S21,24 1450 40.5 30.0 10.40-9.30 24 G2FD060S24 1450 41.0 30.3 10.50-9.60 21 G1FA048S21 1600 47.5 35.6 10.20-9.95 21,24 G1FA060S21,24 1600 49.0 36.8 10.60-10.20 - G1HD048 1630 48.0 36.0 10.20-9.50 - G1HD060 1600 48.5 36.4 10.20-10.20 21 G1NA048S21D 1500 46.5 34.9 10.00-9.40 21 G1UA048S21 1600 47.5 35.6 10.20-9.95 21,24 G1UA060S21,24 1600 49.0 36.8 10.60-10.20 17 G2FD046(S,H)17 1500 47.5 35.6 10.20-9.10 21,24 G2FD048(S,H)21,24 1600 48.5 36.4 10.40-10.00 24 G2FD060(S,H)24 1600 49.0 36.8 10.60-10.20 21,24 G1FA060S21,24 1950 57.5 42.6 10.30-9.55 - G1HD060 2000 57.5 42.6 10.00-9.55 21,24 G1UA060S21,24 1950 57.5 42.6 10.30-9.55 24 G2FD060(S,H)24 1950 58.5 43.3 10.35-9.60 24 G2FD061H24 2000 58.5 43.3 10.35-9.55 21,24 G1FA060S21,24 1950 57.5 42.6 10.00-9.55 21,24 G1UA060S21,24 1950 57.5 42.6 10.00-9.55 24 G2FD060(S,H)24 1950 57.5 42.6 10.00-9.55 24 G2FD061H24 2000 58.5 43.3 10.35-9.55 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. COOLING SEER W/O TDR W/O TXV SEER + TDR W/O TXV EER 8 Unitary Products Group

COOLING PERFORMANCE H4DB018 H4DB024 H4DB030 H4DB036 NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15 superheat and 15 sub-cooling at condensing unit. a. Increase capacity 1% for each 2 increase in sub-cooling. b. Decrease capacity 1% for each 2 decrease in sub-cooling. 3. Sub-cooling in excess of 20 may result in excessively high condensing temperature with air on condenser above 115 F. Maximum recommended condensing temperature is 140 F. 036-21024-006 Rev. D (0403) SUCT. T/P @ AIR TEMP ON CONDENSER SUCT. T/P @ AIR TEMP ON CONDENSER COMPR. 75 F 95 F 115 F COMPR. 75 F 95 F 115 F TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW 35 61.5 17.3 1.38 14.7 1.51 12.0 1.66 35 61.5 41.4 3.09 31.1 4.01 21.7 5.31 40 68.5 19.3 1.43 16.5 1.58 13.7 1.74 40 68.5 45.2 3.15 34.2 4.09 24.0 5.39 H5DB042 45 76.0 21.4 1.48 18.4 1.65 15.4 1.83 45 76.0 49.2 3.23 37.3 4.18 26.4 5.48 50 84.0 23.5 1.53 20.4 1.73 17.1 1.92 50 84.0 53.3 3.32 40.6 4.28 28.9 5.58 35 61.5 27.0 1.84 21.6 2.02 16.5 2.17 35 61.5 46.2 4.18 41.6 4.96 36.9 5.89 40 68.5 29.9 1.90 24.1 2.11 18.7 2.29 40 68.5 50.4 4.28 45.6 4.07 40.7 6.03 H5DB048 45 76.0 33.0 1.97 26.7 2.19 20.9 2.40 45 76.0 54.8 4.37 49.8 5.18 44.6 6.17 50 84.0 36.0 2.02 29.4 2.28 23.3 2.51 50 84.0 59.3 4.47 54.0 5.30 48.6 6.31 35 61.5 29.1 2.48 23.0 2.66 17.4 2.81 35 61.5 53.6 4.21 48.3 4.99 42.8 5.90 40 68.5 32.5 2.58 25.8 2.77 19.6 2.93 40 68.5 58.4 4.31 52.8 5.10 47.1 6.03 H4DB060 45 76.0 36.0 2.68 28.7 2.88 21.9 3.06 45 76.0 63.4 4.42 57.6 5.21 51.5 6.16 50 84.0 39.5 2.78 31.6 2.99 24.3 3.18 50 84.0 68.6 4.53 62.4 5.33 56.1 6.29 35 61.5 39.9 3.43 30.8 3.62 22.5 3.81 35 61.5 76.9 5.37 69.9 6.43 62.9 7.84 40 68.5 44.1 3.55 34.3 3.76 25.2 3.97 40 68.5 84.5 5.53 76.9 6.64 69.3 8.00 H4DB076 45 76.0 48.3 3.67 37.8 3.89 28.1 4.11 45 76.0 92.6 5.70 84.3 6.81 76.0 8.17 50 84.0 52.7 3.78 41.5 4.02 31.1 4.25 50 84.0 101.0 5.88 92.1 6.99 83.1 8.36 CONTROL WIRING POWER WIRING GROUND LUG LOW VOLTAGE JUNCTION BOX ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. TYPICAL INSTALLATION TO INDOOR BLOWER THERMOSTAT TO POWER SUPPLY NEC CLASS 1 WIRING WEATHERPROOF DISCONNECT SWITCH 48 OVERHEAD CLEARANCE 12 REAR AND SIDES NEC CLASS 2 WIRING TO COIL 24 SERVICE ACCESS CLEARANCE NOTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum or equivalent Unitary Products Group 9

TYPICAL FIELD WIRING - 1 PHASE APPLICATION ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 230-1-50 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) POWER WIRING CONTROL WIRING FACTORY WIRING * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. FURNACE OR AIR HANDLER TERMINAL BLOCK C Y R G W GND. LUG CONTACTOR TERMINALS COIL Y R G W * CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. ROOM THERMOSTAT USE COPPER CONDUCTORS ONLY. TYPICAL FIELD WIRING - 3 PHASE APPLICATION GND. LUG ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-3-60 460-3-60 575-3-60 380/415-3-50 CONTACTOR TERMINALS COIL 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLOCK * Y R G W CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. ROOM THERMOSTAT USE COPPER CONDUCTORS ONLY. 10 Unitary Products Group

ACCESSORIES Refer to Price Manual for specific model numbers. 48" OVERHEAD CLEARANCE C Hard Start Kit - Provides increased starting torque for areas with low voltage. B Compressor Blanket - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups. Off Cycle Timer Delay - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. A AIR IN 4 SIDES Room Thermostats - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 5-1/2 1 Heat Stage only, manual, mechanical thermostat. Add subbase for 1H/1C. VAPOR CONNECTION LIQUID CONNECTION 3-1/8 2-3/8 1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. SOUND RATINGS HDB SOUND RATING DECIBELS* 018 76 024 76 030 78 036 78 1 042 78 1 048 79 1 060 78 1 076 78 1 1. Compressor Blanket Factory Installed. * Rated in accordance with ARI Standard 270. All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. 1 PHASE Unit Model HDB Dimensions (Inches) Refrigerant Connection Line Size A B C LIQUID VAPOR 018 20-1/8 24 24 024 20-1/8 24 24 5/8 030 24-1/8 24 24 036 24-1/8 24 24 3/8 3/4 042 30-1/8 24 24 048 30-1/8 24 24 7/8 060 31-7/8 35 35 3 PHASE Unit Model HDB Dimensions (Inches) Refrigerant Connection Line Size A B C Liquid Vapor 036 24-1/8 24 24 3/4 048 30-1/8 24 24 3/8 7/8 060 31-7/8 35 35 076 31-7/8 35 35 1/2 1-1/8 Unitary Products Group 11

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB018 G1FA024S14,17 ID CFM 550 600 650 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 22.1 20.3 18.5 16.8 22.4 20.6 18.8 17.1 22.6 20.8 19.0 17.3 S.C. 13.4 13.4 13.6 13.5 13.8 13.9 14.0 14.0 14.2 14.3 14.4 14.5 K.W 1.81 1.82 1.81 1.79 1.82 1.84 1.84 1.82 1.84 1.86 1.86 1.84 T.C. 21.3 19.5 17.7 16.0 21.5 19.8 17.9 16.3 21.8 19.9 18.1 16.4 S.C. 13.3 13.3 13.5 13.4 13.8 13.8 14.0 14.0 14.3 14.3 14.5 14.5 K.W 1.89 1.90 1.89 1.86 1.91 1.92 1.91 1.88 1.93 1.94 1.94 1.91 T.C. 19.9 18.2 16.4 14.9 20.2 18.4 16.6 15.2 20.3 18.6 16.8 15.4 S.C. 13.0 13.0 13.1 13.2 13.6 13.6 13.7 13.8 14.2 14.1 14.3 14.3 K.W 2.00 2.00 1.98 1.94 2.02 2.02 2.00 1.97 2.04 2.04 2.03 2.00 T.C. 18.4 16.7 15.0 13.6 18.5 16.9 15.2 13.8 18.7 17.0 15.4 13.9 S.C. 12.7 12.6 12.7 12.6 13.2 13.2 13.3 13.2 13.8 13.8 13.9 13.7 K.W 2.13 2.12 2.08 2.04 2.16 2.14 2.11 2.07 2.18 2.17 2.14 2.10 T.C. 16.6 14.9 13.5 12.1 16.7 15.1 13.6 12.4 16.8 15.3 13.8 12.7 S.C. 12.0 12.0 12.0 11.9 12.6 12.6 12.6 12.3 13.2 13.2 13.1 12.6 K.W 2.28 2.25 2.20 2.14 2.30 2.27 2.23 2.18 2.33 2.30 2.26 2.21 T.C. 14.8 13.1 12.0 10.6 14.9 13.3 12.0 11.0 14.9 13.6 12.2 11.5 125 S.C. 11.3 11.4 11.3 11.2 12.0 12.0 11.9 11.4 12.6 12.6 12.3 11.5 K.W 2.43 2.38 2.32 2.24 2.44 2.40 2.35 2.29 2.48 2.43 2.38 2.32 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB08 G2FD024(S,H)17 1.02 1.02 1.01 N1VSB12 G2FD024(S,H)17 1.04 1.04 0.93 F2RC/F2FC024 1.01 1.01 1.02 F2RP/F2FP018 0.98 0.98 0.99 Coil T.C. S.C. KW G1FA030S14 1.02 1.02 1.01 G1HD024 1.03 1.03 1.01 G1NA030S17 1.03 1.03 1.00 G1UA024S14,17 1.00 1.00 1.00 G1UA030S14 1.02 1.02 1.01 G2FD024(S,H)14,17 1.02 1.02 1.01 G2FD030(S,H)17 1.03 1.04 1.00 G2FD035(S,H)14 1.03 1.04 1.00 M1HC018F01 0.91 0.91 0.87 12 Unitary Products Group

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB024 G1FA024S14,17 ID CFM 750 800 850 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 28.1 25.7 23.4 21.2 28.3 25.9 23.6 21.4 28.5 26.1 23.8 21.5 S.C. 17.3 17.3 17.4 17.4 17.7 17.7 17.8 17.8 18.1 18.1 18.2 18.2 K.W 2.15 2.10 2.04 1.99 2.18 2.12 2.07 2.02 2.20 2.15 2.10 2.04 T.C. 28.0 25.6 23.2 21.0 28.2 25.8 23.4 21.2 28.4 26.0 23.6 21.4 S.C. 17.7 17.7 17.8 17.8 18.1 18.2 18.3 18.3 18.6 18.6 18.8 18.8 K.W 2.31 2.25 2.18 2.11 2.34 2.27 2.21 2.14 2.36 2.30 2.23 2.17 T.C. 26.7 24.4 22.1 19.9 26.9 24.6 22.3 20.3 27.1 24.8 22.4 20.5 S.C. 17.7 17.7 17.8 17.8 18.2 18.2 18.3 18.5 18.7 18.7 18.8 19.0 K.W 2.52 2.44 2.36 2.28 2.55 2.47 2.39 2.32 2.57 2.50 2.42 2.35 T.C. 25.0 22.8 20.6 18.7 25.1 22.9 20.8 18.9 25.3 23.1 21.0 19.0 S.C. 17.4 17.3 17.5 17.5 18.0 17.9 18.2 18.0 18.5 18.5 18.7 18.5 K.W 2.74 2.66 2.56 2.48 2.77 2.68 2.59 2.51 2.79 2.71 2.62 2.54 T.C. 22.8 20.7 18.8 17.0 22.9 20.8 18.9 17.3 23.0 21.0 19.1 17.5 S.C. 16.7 16.6 16.8 16.5 17.2 17.2 17.3 17.3 17.8 17.7 17.7 17.5 K.W 2.96 2.85 2.75 2.66 2.98 2.88 2.78 2.70 3.01 2.92 2.82 2.73 T.C. 20.6 18.6 17.0 15.3 20.7 18.7 17.0 15.7 20.7 18.9 17.2 16.0 125 S.C. 16.0 15.9 16.1 15.5 16.4 16.5 16.4 16.6 17.1 16.9 16.7 16.5 K.W 3.18 3.04 2.94 2.84 3.19 3.08 2.97 2.89 3.23 3.13 3.02 2.92 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB08 G2FD024(S,H)17 1.00 1.00 1.00 N1AHB08 G2FD030(S,H)17 1.02 1.02 1.00 N1VSB12 G2FD024(S,H)17 1.04 1.04 1.01 N1VSB12 G2FD036(S,H)17 1.07 1.07 0.94 F2RC/F2FC024 0.93 0.93 1.00 F2RP/F2FP024 0.97 0.97 1.06 F2RP/F2FP030 0.98 0.98 1.06 F2FP040 1.04 1.04 1.05 Coil T.C. S.C. KW G1HD024 0.94 0.95 1.00 G1HD036 1.04 1.04 1.04 G1NA030S17 0.99 0.99 1.00 G1UA024S14,17 1.00 1.00 1.00 G1UA030S14 1.01 1.01 1.03 G2FD024(S,H)14,17 1.01 1.01 1.03 G2FD036(S,H)17 1.03 1.03 1.01 G1FA036S17,21 1.02 1.02 1.01 G1UA036S17,21 1.02 1.02 1.01 G2FD030(S,H)17 1.02 1.02 1.01 G2FD035(S,H)14 1.02 1.02 1.01 G1FA030S14 1.01 1.01 1.03 M1HC024F01 0.98 0.98 0.88 Unitary Products Group 13

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB030 G1FA036S17,21, G2FD030(S,H)17 ID CFM 900 1000 1100 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 33.5 30.7 27.9 25.3 34.1 31.3 28.4 25.8 34.6 31.7 28.9 26.2 S.C. 21.0 21.1 21.2 20.8 21.8 21.9 22.1 20.9 22.6 22.7 22.9 21.7 K.W 2.63 2.55 2.46 2.38 2.68 2.60 2.51 2.43 2.72 2.64 2.55 2.47 T.C. 33.2 30.4 27.6 24.9 33.8 30.9 28.1 25.4 34.2 31.3 28.5 25.8 S.C. 21.1 21.1 21.3 20.9 22.0 22.0 22.3 21.1 22.8 22.9 23.1 21.9 K.W 2.81 2.72 2.62 2.53 2.86 2.77 2.67 2.58 2.90 2.81 2.72 2.62 T.C. 31.3 28.6 25.9 23.4 31.7 29.0 26.3 23.8 32.0 29.3 26.6 24.1 S.C. 20.5 20.6 20.8 20.4 21.4 21.5 21.8 20.6 22.2 22.3 22.6 21.4 K.W 2.98 2.89 2.78 2.68 3.03 2.94 2.84 2.74 3.07 2.98 2.88 2.78 T.C. 28.7 26.2 23.7 21.4 29.1 26.6 24.1 21.8 29.3 26.8 24.4 22.2 S.C. 19.5 19.6 19.8 19.5 20.5 20.7 21.0 19.8 21.5 21.5 21.9 20.8 K.W 3.15 3.05 2.95 2.84 3.20 3.10 2.99 2.89 3.23 3.14 3.03 2.93 T.C. 25.7 23.5 21.3 19.3 26.1 23.8 21.5 19.6 26.2 24.0 21.9 19.9 S.C. 18.5 18.5 18.7 18.5 19.6 19.5 19.7 18.6 20.5 20.5 20.8 19.6 K.W 3.30 3.20 3.09 2.98 3.34 3.25 3.14 3.04 3.38 3.28 3.18 3.08 T.C. 22.7 20.8 18.9 17.2 23.1 21.0 18.9 17.4 23.1 21.2 19.4 17.6 125 S.C. 17.5 17.4 17.6 17.5 18.7 18.3 18.4 17.4 19.5 19.5 19.7 18.4 K.W 3.45 3.35 3.23 3.12 3.48 3.40 3.29 3.19 3.53 3.42 3.33 3.23 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB12 G2FD030(S,H)17 1.00 1.00 1.01 N1AHB12 G2FD036(S,H)17 1.03 1.03 0.95 N1VSB12 G2FD036(S,H)17 1.03 1.03 0.95 N1VSB12 G2FD046(S,H)17 1.07 1.07 0.96 F2RC/F2FC030 0.97 0.97 1.01 F2RC/F2FC036 1.00 1.00 1.03 F2RP/F2FP030 1.00 1.00 1.02 F2RP/F2FP036 1.03 1.03 1.04 F2RP/F2FP036 1.03 1.03 1.04 Coil T.C. S.C. KW G1FA036S14 1.00 1.00 1.00 G1FA048S17 1.03 1.03 1.01 G1HD036 1.01 1.01 1.02 G1NA030S17K 1.01 1.01 1.01 G1UA030S14 0.99 0.99 1.00 G1UA036S14 1.00 1.00 1.00 G1UA036S17,21 1.00 1.00 1.00 G1UA048S17 1.03 1.03 1.01 G2FD030(S,H)17 1.00 1.00 1.01 G2FD035(S,H)14 1.00 1.00 1.03 G2FD036(S,H)17 1.03 1.03 1.04 G2FD036(S,H)21 1.03 1.03 1.03 G2FD042(S,H)21 1.03 1.03 1.02 G2FD046(S,H)17 1.03 1.03 1.03 G1FA030S14 0.99 0.99 1.00 14 Unitary Products Group

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB036 G1FA036S17,21 ID CFM 1100 1200 1300 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 41.4 37.9 34.5 31.3 41.9 38.4 35.0 31.8 42.3 38.8 35.4 32.1 S.C. 25.5 25.6 25.8 25.9 26.3 26.4 26.7 26.8 27.1 27.2 27.6 27.7 K.W 3.43 3.33 3.22 3.11 3.49 3.39 0.88 3.17 3.53 3.43 3.33 3.22 T.C. 40.9 37.5 34.0 30.9 41.3 37.9 34.4 31.2 41.7 38.2 34.8 31.6 S.C. 25.7 25.8 26.1 26.1 26.6 26.7 27.0 27.1 27.4 27.6 27.9 28.0 K.W 3.66 3.55 3.43 3.31 3.72 3.61 3.49 3.37 3.76 3.65 3.53 3.41 T.C. 38.3 35.1 31.9 28.8 38.6 35.4 32.2 29.3 39.0 35.8 32.5 29.7 S.C. 25.1 25.2 25.5 25.6 26.0 26.2 26.5 26.8 27.1 27.2 27.6 27.8 K.W 3.87 3.76 3.64 3.51 3.93 3.82 3.69 3.58 3.97 3.86 3.73 3.62 T.C. 35.0 32.1 29.2 26.5 35.3 32.3 29.3 26.8 35.5 32.5 29.7 27.1 S.C. 24.2 24.3 24.7 24.8 25.3 25.3 25.6 25.8 26.3 26.3 26.9 26.7 K.W 4.08 3.96 3.83 3.70 4.13 4.02 3.89 3.77 4.18 4.06 3.93 3.81 T.C. 31.3 28.7 26.1 23.8 31.5 28.9 26.4 24.5 31.6 29.0 26.5 24.8 S.C. 23.1 23.1 23.5 23.4 24.1 24.2 24.4 24.7 25.1 25.2 25.2 25.0 K.W 4.27 4.15 4.01 3.88 4.32 4.20 4.07 3.97 4.36 4.24 4.13 4.03 T.C. 27.6 25.3 23.0 21.1 27.7 25.5 23.5 22.2 27.7 25.5 23.3 22.5 125 S.C. 22.0 21.9 22.3 22.0 22.9 23.1 23.2 23.6 23.9 24.1 23.5 23.3 K.W 4.46 4.34 4.19 4.06 4.51 4.38 4.25 4.17 4.54 4.42 4.33 4.25 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB12 G2FD036(S,H)17 1.01 1.01 0.99 N1AHB12 G2FD046(S,H)17 1.03 1.03 1.01 N1VSB12 G2FD036(S,H)17 1.03 1.03 0.98 N1VSB12 G2FD046(S,H)17 1.05 1.05 0.96 N1VSC16 G2FD048(S,H)21 1.07 1.07 0.96 F2RC/F2FC036 1.00 1.00 0.99 F2RP/F2FP036 1.04 1.04 1.00 F2RP/F2FP042 1.05 1.05 1.01 F2FP045 1.05 1.05 1.02 Coil T.C. S.C. KW G1FA036S14 1.00 1.00 1.00 G1FA048S17 1.05 1.05 1.00 G1FA048S21 1.05 1.05 1.00 G1HD036 1.00 1.00 1.00 G1HD048 1.04 1.04 1.01 G1NA036S17J 1.01 1.01 0.99 G1NA036S17D 0.99 0.99 1.03 G1NA036S21C 1.01 1.01 0.99 G1NA048S21D 1.04 1.04 1.00 G1UA036S14 1.00 1.00 1.00 G1UA036S17,21 1.00 1.00 1.00 G1UA048S17 1.05 1.05 1.00 G1UA048S21 1.05 1.05 1.00 G2FD035(S,H)14 0.99 0.99 0.99 G2FD036(S,H)21 1.04 1.04 1.02 G2FD042(S,H)21 1.04 1.04 1.00 G2FD046(S,H)17 1.03 1.03 1.01 G2FD048(S,H)21,24 1.05 1.05 0.99 G2FD036(S,H)17 1.01 1.01 0.99 M3HD048S 0.99 0.99 1.03 Unitary Products Group 15

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H5DB042 G1FA048S21 ID CFM 1300 1400 1500 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 48.0 44.1 40.1 36.5 48.4 44.5 40.5 36.9 48.8 44.8 40.9 37.5 S.C. 29.9 30.0 30.3 30.3 30.8 30.9 31.2 31.2 31.6 31.7 32.1 32.4 K.W 3.98 3.85 3.71 3.57 4.04 3.91 3.77 3.63 4.09 3.97 3.83 3.70 T.C. 46.3 42.5 38.7 35.3 46.6 42.8 39.0 35.7 46.9 43.1 39.3 36.0 S.C. 29.8 29.9 30.2 30.5 30.8 30.9 31.2 31.4 31.7 31.8 32.1 32.3 K.W 4.24 4.11 3.96 3.81 4.30 4.16 4.02 3.88 4.35 4.22 4.07 3.94 T.C. 43.8 40.2 36.6 33.4 44.2 40.5 37.0 33.8 44.3 40.8 37.3 34.1 S.C. 29.3 29.4 29.7 29.7 30.5 30.4 31.0 30.9 31.3 31.4 31.9 32.0 K.W 4.48 4.34 4.18 4.03 4.53 4.39 4.24 4.08 4.59 4.45 4.30 4.16 T.C. 40.8 37.5 34.2 31.1 41.1 37.7 34.5 31.5 41.3 38.0 34.7 32.3 S.C. 28.5 28.6 28.9 28.8 29.6 29.6 29.9 30.0 30.7 30.7 30.9 31.5 K.W 4.70 4.55 4.39 4.22 4.75 4.61 4.45 4.29 4.80 4.67 4.51 4.38 T.C. 37.8 34.7 31.7 28.9 37.9 34.9 31.9 29.7 38.3 35.2 32.2 30.1 S.C. 27.6 27.6 27.9 27.8 28.5 28.6 28.9 29.0 29.7 29.8 30.1 29.4 K.W 4.90 4.75 4.58 4.41 4.97 4.81 4.64 4.50 5.01 4.86 4.70 4.57 T.C. 34.8 31.9 29.2 26.7 34.7 32.1 29.3 27.9 35.3 32.4 29.7 27.9 125 S.C. 26.7 26.6 26.9 26.8 27.4 27.6 27.9 28.0 28.7 28.9 29.3 27.3 K.W 5.10 4.95 4.77 4.60 5.19 5.01 4.83 4.71 5.22 5.05 4.89 4.76 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHC16 G2FD042(S,H)21 0.98 0.98 1.03 N1AHC1606 G2FD046(S,H)21 0.99 0.99 1.04 N1AHD2006 G2FD048(S,H)24 1.00 1.00 1.02 N1VSC16 G2FD048(S,H)21 1.01 1.01 0.97 F2RP/F2FP042 0.98 0.98 1.04 F2FP048 0.99 0.99 1.04 Coil T.C. S.C. KW G1UA048S21 1.00 1.00 1.00 G2FD046(S,H)17 0.99 0.99 1.04 G2FD048(S,H)21,24 1.00 1.00 1.02 G2FD060(S,H)24 1.01 1.01 1.00 G1HD048 0.99 0.99 1.03 G2FD042(S,H)21 0.98 0.98 1.03 G1NA048S21D 0.98 0.98 1.02 16 Unitary Products Group

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H5DB048 G1FA048S21 ID CFM 1550 1600 1650 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 53.0 49.0 45.0 41.2 53.2 49.2 45.2 41.4 53.4 49.3 45.3 41.5 S.C. 34.5 34.8 35.3 35.6 35.0 35.2 35.8 36.0 35.4 35.6 36.3 36.5 K.W 4.06 3.98 3.91 3.85 4.08 4.00 3.93 3.86 4.10 4.02 3.95 3.88 T.C. 52.6 48.5 44.5 40.9 52.7 48.7 44.6 41.0 52.9 48.9 44.8 41.2 S.C. 34.9 35.1 35.8 36.1 35.4 35.7 36.3 36.6 36.0 36.2 36.7 37.0 K.W 4.44 4.35 4.26 4.19 4.45 4.36 4.28 4.21 4.47 4.38 4.30 4.23 T.C. 51.3 47.3 43.4 39.7 51.5 47.5 43.4 39.9 51.6 47.6 43.6 40.0 S.C. 34.9 35.1 35.8 35.8 35.4 35.6 36.1 36.3 35.9 36.1 36.6 36.8 K.W 4.72 4.62 4.53 4.45 4.73 4.64 4.55 4.47 4.76 4.66 4.57 4.49 T.C. 49.6 45.7 41.7 38.3 49.7 45.8 41.9 38.4 49.9 46.0 42.1 38.6 S.C. 34.4 34.7 35.0 35.2 34.9 35.2 35.7 35.7 35.5 35.7 36.4 36.3 K.W 5.00 4.90 4.81 4.71 5.01 4.91 4.81 4.73 5.03 4.94 4.84 4.76 T.C. 47.6 43.9 40.1 36.7 47.8 44.0 40.3 36.8 47.9 44.1 40.4 37.0 S.C. 33.6 33.8 34.4 34.4 34.3 34.4 35.1 34.9 34.7 34.9 35.4 35.5 K.W 5.29 5.18 5.08 4.98 5.30 5.20 5.09 5.00 5.33 5.22 5.12 5.02 T.C. 45.6 42.1 38.5 35.1 45.9 42.2 38.7 35.2 45.9 42.2 38.7 35.4 125 S.C. 32.8 32.9 33.8 33.6 33.7 33.6 34.5 34.1 33.9 34.1 34.4 34.7 K.W 5.58 5.46 5.35 5.25 5.59 5.49 5.37 5.27 5.63 5.50 5.40 5.28 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHC16 G2FD048(S,H)21 1.02 1.02 1.02 N1AHC16 G2FD048(S,H)24 1.02 1.02 1.00 N1AHD20 G2FD060(S,H)24 1.03 1.03 1.01 N1VSC16 G2FD048(S,H)21 1.03 1.03 0.98 N1VSD20 G2FD048(S,H)24 1.04 1.04 0.97 N1VSD20 G2FD060(S,H)24 1.03 1.03 1.00 F2FP048 1.00 0.99 1.00 F2FP060 1.01 1.00 1.02 Coil T.C. S.C. KW G1UA048S21 1.00 1.00 1.00 G2FD060(S,H)24 1.03 1.03 1.01 G1FA060S21,24 1.03 1.03 1.01 G2FD048(S,H)21,24 1.02 1.02 1.02 G1FD046S17 1.00 1.00 1.09 G1HD048 1.01 1.01 1.06 G1HD060 1.02 1.02 1.00 G1NA048S21D 0.98 0.98 1.04 G1UA060S21,24 1.03 1.03 1.01 Unitary Products Group 17

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB060 G1FA060S21,24 ID CFM 1700 1850 2000 ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 33.7 58.8 53.8 49.2 64.3 59.3 54.4 49.7 64.8 59.8 54.8 50.5 S.C. 40.1 40.4 41.0 41.3 41.5 41.8 42.4 42.7 42.8 43.1 43.8 44.5 K.W 5.27 5.16 5.06 4.96 5.34 5.24 5.13 5.04 5.41 5.30 5.19 5.11 T.C. 63.1 58.1 53.1 48.4 63.7 58.7 53.6 49.3 64.1 59.1 54.1 49.8 S.C. 40.7 40.9 41.5 41.7 42.2 42.4 43.0 43.5 43.7 43.9 44.7 45.0 K.W 5.75 5.63 5.52 5.41 5.83 5.71 5.60 5.49 5.90 5.78 5.65 5.56 T.C. 62.1 57.2 52.2 47.7 62.7 57.5 52.5 48.2 63.1 58.0 53.1 48.6 S.C. 40.9 41.1 41.7 42.0 42.6 42.6 43.2 43.5 44.2 44.2 45.0 45.0 K.W 6.08 5.96 5.83 5.73 6.16 6.04 5.92 5.81 6.23 6.11 5.99 5.88 T.C. 60.4 55.5 50.5 46.1 60.9 55.9 51.2 46.7 61.2 56.3 51.6 47.2 S.C. 40.3 40.6 41.1 41.3 42.1 42.2 43.1 43.2 43.7 44.0 44.8 44.8 K.W 6.42 6.29 6.16 6.04 6.50 6.37 6.23 6.12 6.57 6.43 6.30 6.18 T.C. 58.2 53.4 48.7 44.5 58.7 53.9 49.3 44.9 59.1 59.3 49.7 45.5 S.C. 39.5 39.7 40.4 40.6 41.2 41.4 42.2 42.3 43.1 43.2 43.7 44.1 K.W 6.75 6.61 6.47 6.34 6.83 6.69 6.54 6.42 6.89 6.45 6.62 6.49 T.C. 56.0 51.3 46.9 42.9 56.5 51.9 47.4 43.1 57.0 62.3 47.8 43.8 125 S.C. 38.7 38.8 39.7 39.9 40.3 40.6 41.3 41.4 42.5 42.4 42.6 43.4 K.W 7.08 6.93 6.78 6.64 7.16 7.01 6.85 6.72 7.21 6.47 6.94 6.80 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHD20 G2FD060(S,H)24 1.02 1.02 1.02 N1VSD20 G2FD060(S,H)24 1.03 1.03 0.93 N1VSD20 G2FD061H24 1.03 1.03 0.94 F2FP060 0.99 0.99 1.02 Coil T.C. S.C. KW G1HD060 1.00 1.00 1.00 G1UA060S21,24 1.00 1.00 1.00 G2FD060(S,H)24 1.02 1.02 1.02 G2FD061H24 1.02 1.03 1.02 H4DB060S25,46 ONLY Coil T.C. S.C. KW G2FD060S24 1.00 1.00 1.00 K2EU060 0.97 0.93 1.05 18 Unitary Products Group

COOLING PERFORMANCE DATA AIR CONDITIONER NO. INDOOR COIL NO. CONDENSER ENTERING AIR TEMPERATURE 75 85 95 105 115 H4DB076 KEU090A33A ID CFM 1900 2550 3150 ID DB ( F) 85 80 70 85 80 70 85 80 70 ID WB ( F) 72 67 57 72 67 57 72 67 57 T.C. 75.4 72.8 70.5 78.2 75.5 73.4 81.0 78.2 76.2 S.C. 46.5 46.3 45.9 52.8 52.7 52.2 59.1 59.0 58.4 K.W 6.11 6.03 5.97 6.42 6.32 6.29 6.72 6.62 6.60 T.C. 72.9 70.3 67.3 75.4 72.8 70.0 77.9 75.3 72.7 S.C. 45.7 45.4 44.6 52.2 51.9 51.1 58.6 58.3 57.5 K.W 6.67 6.56 6.51 7.01 6.89 6.85 7.34 7.22 7.19 T.C. 70.4 67.8 64.1 72.6 70.1 66.7 74.8 72.4 69.2 S.C. 44.9 44.5 43.3 51.5 51.1 50.0 58.1 57.6 56.6 K.W 7.23 7.09 7.05 7.60 7.46 7.42 7.96 7.82 7.78 T.C. 67.8 64.3 59.7 69.7 66.5 62.2 71.6 68.7 64.6 S.C. 44.2 43.3 41.7 50.6 49.8 48.1 57.0 56.2 54.5 K.W 8.01 7.87 7.78 8.39 8.26 8.16 8.76 8.65 8.54 T.C. 65.2 60.8 55.3 66.8 63.9 57.7 68.4 65.0 60.0 S.C. 43.3 42.0 40.0 49.6 49.5 46.2 55.9 54.8 52.4 K.W 8.78 8.64 8.50 9.17 8.99 8.90 9.56 9.48 9.30 T.C. 62.6 57.3 50.9 63.9 61.3 53.2 65.2 61.3 55.4 125 S.C. 42.4 40.7 38.3 48.6 49.2 44.3 54.8 53.4 50.3 K.W 9.55 9.41 9.22 9.96 9.72 9.64 10.36 10.31 10.06 NOTE: NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Unitary Products Group 19

MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1UA 1/2 CASED UPFLOW G1HD HORIZONTAL DUCT G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) G2FD COIL F2RC / F2FC OR F2RP / F2FP / F3RP / F3FP/ F2FV FAN COIL UNITS (UPFLOW, HORIZONTAL) Subject to change without notice. Printed in U.S.A. 036-21024-006 Rev. D (0403) Copyright by York International Corp. 2003. All rights reserved. Supersedes: 036-21024-006 Rev C (0203) Unitary 5005 Norman Product York OK Group Drive 73069