Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Similar documents
Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Sheet-Steel Light Fittings Series 6014 / 6414

7 Lighting Technology

Linear Luminaire with LED Series EXLUX 6402/2

LED Linear Luminaire Series EXLUX 6402

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Sheet-Steel Light Fittings Series 6114

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight LED Series 6525

Plug and Socket Devices SolConeX 16 A Series 8570

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight LED Series 6525

7 Lighting Technology

Floodlight Series 6121

Floodlight LED Series 6125

Sheet Steel Emergency Light Fitting Series 6018

Load disconnect switch Series 8146/5-V11

Terminal Boxes Series 8125

Floodlight Series 6521/4

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Terminal Boxes Series 8125

Linear Luminaire for Fluorescent Lamps

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Tank Inspection Lights Series 6122

Position Switches Series 8074/2

Safety Switches Series 8537

Position Switches Series 8070/2

Position Switches Series 8060/2

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Control Buttons / Switches for Panel Mounting Series 8003

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Battery Boxes Series 8316

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Tubular Light Fitting with LED Series 6036

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Ex UPS standard Series 8265

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

7 Lighting Technology

7 Lighting Technology

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Linear Luminaire with LED

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Control switch/load disconnect switch Series 8008

Linear fluorescent luminaire LED V-CG-S

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Pendant Light Fitting IEC

Portable Lamps Series HS6145, HSL145

Metal Position Switch Series 8074

EXEL-L. Detail of the internal side. Transparent polycarbonate

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Control Device System NEC Series ConSig 8040

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Load and Motor Switches, Load-Break Switches Series 8549

Control Buttons Series 8082

Operating Instructions

Linear fittings EVDL LED fitting - zones 21, & 22

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Linear fittings EVNL LED fitting - zones 2, & 22

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

K: bracket type. L: pole type

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544

Operating Instructions

10 Load and Motor Switchgear

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

M-0. M-0... series control, monitoring and signalling devices. Ex e

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Easy and safe installation

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Transcription:

> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600 are useable for normal lighting, but also as group or centrally-supplied emergency light fitting. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 for use in x x x for use in x for use in x x x x x WebCode 6600A Lighting /1

Selection Table Version Lamp wattage W Through wiring Cable glands Order number Art. no. Weight ECOLUX 6600 18 with 5 cores plastic M25 6600/522-8510-6250 225333 3.700 Order Number Supplement metal M20 6600/522-8500-6250 225329 3.800 36 with 5 cores plastic M25 6600/542-8510-6250 225477 5.500 metal M20 6600/542-8500-6250 225473 5.600 58 with 5 cores plastic M25 6600/562-8510-6250 225597 6.600 metal M20 6600/562-8500-6250 225593 6.750 Through wiring Without 6600/...-.0..-... With 5 conductors 6600/...-.5..-... Cable entry Standard: M25 x 1.5; 1 cable entry, 6600/...-..2.-... 2 stopping plugs kg Metalleinschubplatte M20 6600/...-..1.-... ECG 220... 240 V 2-lamps AC, 1-lamp DC 6600/...-...-0... 220... 240 V 2-lamps AC, 2-lampigs DC (standard) Terminal strip Special: terminal strip 8184, 4 / 6 mm 2 solid / finely stranded 6600/...-...-.1.. Standard: WAGO 265 2.5 mm 2 6600/...-...-.2.. Number of terminals Standard: with 3 cores; L1 + N + PE 6600/...-...-..3. Note Special: with 5 cores; L1 + L2 + L3 + N + PE 6600/...-...-..5. The light fittings are supplied without tubes and mounting accessories. These parts must be ordered separately. Explosion Protection Explosion protection Global (IECEx) Gas and dust IECEx BVS 07.0023X Ex na II T4 Gc Ex tc IIIC T * C Dc oder Ex tb IIIC T * C Db * surface temperature see test certificate Europe (ATEX) Gas Dust Certifications and certificates Certificates Ship approval Zone 2: DMT 01 E 085 X Zone 2: E II 3 G Ex na IIC T4 Gc Zone 21: DMT 01 ATEX E 086X Zone 22: DMT 01 E 085X Zone 21: E II 2 D Ex tb IIIC T * C Db Zone 22: E II 3 D Ex tc IIIC T * C Dc * surface temperature see test certificate IECEx, ATEX, Brazil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), USA Canada (FM), Belarus (operating authorisation), Taiwan (ITRI) GL /2 Lighting

Technical Data Electrical data Ballast Power factor cos p Disconnection of the light Luminous characteristics Measures for light guidance Luminous intensity distribution 6600/5..-...-0... 6600/5..-...-6... Lamp start Cold start Cold start Voltage 220... 240 Vac 220... 240 Vac Voltage 198 264 Vdc 198 264 Vdc DC during switching on Voltage 176 264 Vdc 176 264 Vdc DC during operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC with 1 lamp with 2 lamps Lamps standard IEC 60081 IEC 60081 Lamp power 18, 36, 58 W 18, 36, 58 W Nominal current cos p ) 0.96 capacitive; additional compensation not required Faulty lamp 2x18W 170mA 2x36W 320mA 2x58W 500mA 2x18W 150mA 2x36W 300mA 2x58W 480mA If lamp is faulty, power supply of lamps is switched off automatically by electronic ballast; when using a 2-channel-ECG power is switched off only to the defective lamp. Standard Wide beam, reflector painted white. Colour: signal white RAL 9003; prismatic structure for anti-glare in the diffuser sides. Special Additional reflector (easily mounted), broad deep-beam, aluminium anodized and semi-polished. 08258E00 Version 1-lamp, without reflector 1-lamp, with reflector Accuracy class acc. to LitG B21 B31 08257E00 08259E00 Version 2-lamp, without reflector 2-lamp, with reflector Accuracy class acc. to LitG B21 B31 08257E00 Lighting /3

Technical Data Ambient conditions Umgebungstemperatur without trough wiring with trough wiring T a T s max T a T s max 220.. 240 V (IEC) 6600/52.-...-0... -25... +55 C +80 C -25... +55 C +80 C 6600/54.-...-0... -25... +55 C +80 C -25... +55 C +80 C 6600/56.-...-0... -25... +55 C +80 C -25... +55 C +80 C 220... 240 V (IEC) 6600/52.-...-6... -25... +55 C +70 C -25... +55 C +70 C 6600/54.-...-6... -25... +55 C +70 C -25... +55 C +70 C 6600/56.-...-6... -25... +55 C +75 C -25... +55 C +75 C Mechanical data Degree of protection IP66 (IP64 when using breather 8162) Protection class I (with internal PE connection terminal) Material Enclosure Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Lamp cover Polycarbonate Seal Silicone-gasket foamed into diffuser Quick-acting locks Polyamide, glass fibre reinforced, black / white Assembly parts Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Cover lock Quick fasteners to open with screw-driver; cover hinged for access. Mounting / Installation Mounting Cable glands Connection Standard Special Installation notes Looping through of cables Through wiring 2 x M8 inserts in housing Mounting grooves in housing to accommodate bracket fitting and ceiling rails for variable light installation. Variable mounting distances of light fittings; see dimension drawings Standard 1 x cable gland 8161, M25 x 1.5, cable dia. range: d 7... 17 mm 2 x stopping plugs 8290, M25 x 1.5 Special Entry parts in moulded plastic (8161 / 8290): M20 Metal glands: M20; M25; Metal cable gland earthing via metal adapter plates Spring clamp terminal connection cross-section: max. 2 x 2.5 mm 2 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Terminal block with screw terminals connection cross-section: max. 2 x 6 mm 2 (solid) max. 2 x 4 mm 2 (flexible) numbers of terminals: 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) There are 2 M25 x 1.5 cable entries on the connection side for looping through of connection cable (entry and exit on one side). Fittings can be supplied with internal through-wiring. Entry and exit holes for connection cables are positioned on opposite sides. A through-wiring kit can be fitted after manufacture (see accessories). Terminals: See technical data top Wiring cross-section: 2.5 mm 2 for max. 16 A /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white Pins made of brass 18 W 1350 Im 36 W 3350 Im kg 108952 0.100 108951 0.200 58 W 5200 Im 108950 0.220 Diffuser cover for light fitting 18 W 124890 0.500 for light fitting 36 W 124897 0.860 05329E00 for light fitting 58 W 124904 0.800 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Reflectors 05324E00 for later installation, broad deep beam For 2-lamps light fitting 18 W 117098 0.265 For 2-lamps light fittings 36 W 117115 0.234 For 2-lamps light fittings 58 W 117145 0.290 Adapter plates for earth continuity when using metal glands; 2 x M20 x 1.5 1 piece 115826 0.060 05755E00 2 x M25 x 1.5 1 piece 115828 0.060 Lamp-holder Lamp holder for two-pin cap lamps G 13 107275 0.008 05888E00 Mounting rail for a variable mounting distance of 1 pair 124894 0.210 05895E00 Mounting clamp bracket 05896E00 Mounting bracket mounted on the mounting rail for a variable mounting distance 1 pair 124901 0.300 Ring bolts M8, direct mounting in insert nuts 1 pair 115736 0.120 Wall-mounting bracket 05378E00 to mount the lamps as side-entry lamps using a tube with a length of 1300 mm, d 42 mm (for pipe clamp R 1 1 / 2 ) 109281 4.215 Ceiling mounting bracket 05460E00 for ceiling suspension of the lamp, 1 pair 124908 0.230 05897E00 Lighting /5

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Pipe clamps Mounting set,,grid cable rack 09402E00 with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 4 (d 42 mm) 124913 1.140 R 1 1 / 2 (d 48 mm) 124891 1.160 R 2 (d 60 mm) 124898 1.300 for grid cable racks, with a cable diameter of 6 mm; with mounting rail for a variable mounting distance; Material: stainless steel 124905 1.560 Ceiling and wallmounting bracket 04361E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 1 pair 124910 1.150 05898E00 Cable gland 02055E00 of moulded material, Series 8161 8161/5-M20-13 1 piece 138518 0.012 02055E00 8161/5-M20-13 50 pieces 138454 0.600 8161/5-M25-17 1 piece 138520 0.020 8161/5-M25-17 50 pieces 138456 1.000 Stopping plug of moulded material, Series 8290 04840E00 8290/3-M20 1 piece 143522 0.005 8290/3-M20 100 pieces 143543 0.500 8290/3-M25 x 1,5 1 pieces 143524 0.007 8290/3-M25 100 pieces 143544 0.700 Breathing gland for installation in lights; in moulded material; without counter nut 05703E00 Thread: M25 x 1.5 1 pc 138573 0.010 Thread: M25 x 1.5 20 pcs 138576 0.200 /6 Lighting

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Light fittings ECOLUX 6600, 18 W, 36 W, 58 W 04824E00 Dimensions Light fitting 18 W 36 W 58 W L1 700 1310 1610 L2 1) 400 800 800 L3 2) 340... 460 680... 920 795... 1030 1) Fixed mounting distance 2) Variable mounting distance Pipe clamp 04717E00 Mounting set grid cable rack 04822E00 04716E00 04833E00 Ceiling- and wall-mounting bracket Ceiling mounting bracket 04823E00 04715E00 04834E00 Wall mounting bracket for pole-mounting version Ring bolt Mounting clamp bracket Installation accessories We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7