Actuators for small valves

Similar documents
Electric actuators for small valves

Electrical Actuators

Electromotoric Actuators

Electromotoric actuators

2-position electric actuators with Ball valves VBZ ½...11/4

Modulating control valve PN16 with magnetic actuator

Air damper actuators

Two-port and three-port small valves PN16, ANSI Class 250

Air damper actuators

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

GDB..3..1A GLB..3..1A

Differential Pressure Sensors

2-Port and 3-Port Zone Valves, PN16

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

Electromotoric Actuators

Electromotoric Actuators

Butterfly valves, PN6, PN10, PN16

SAX Electronic Valve Actuator

2-Port and 3-Port Zone Valves, PN 16 / 20

SQL35.00 SQL85.00 SQK angle of rotation

2-port and 3-port valves with T-bypass PN 16

Modulating control valve PN16 with magnetic actuator

2-port and 3-port terminal unit valves PN16

Electro-hydraulic actuators for valves

2-Port and 3-Port Zone Valves & Actuators, PN16

Electromotoric Actuators

Electromotoric Actuators

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Control of cutting-oil emulsion for industrial grinding machines. Applications for CHW and LPHW systems, see data sheet CA1N4454E.

Electromotoric Actuators

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

SAV Electronic Valve Actuator

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

Modulating control valve PN16

Pressure sensor for liquid and gaseous media QBE620-P...

Butterfly valves PN6, PN10, PN16

Modulating control valves with magnetic actuators, PN 16

2-Port and 3-Port Zone Valves PN 16

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Modulating control valves with magnetic actuator PN 16

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Electromotoric actuators

3-Port Seat Valves with Male Thread, PN 16

Modulating control valve with magnetic actuator PN16

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

3-port seat valves, external thread, PN16

Actuators for Fire Protection Dampers

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Modulating control valves with magnetic actuators, PN 16

Actuators for Fire and Smoke Protection Dampers

2-Port and 3-Port Zone Valves PN 16

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Overview of types. Technical data. Safety notes

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Differential Pressure Sensors

Butterfly valves PN6, PN10, PN16

Rotary actuators for ball valves

Gas Pressure Governors

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Immersion temperature sensor QAE26.9.

Modulating Control Valve PN 16 with Magnetic Actuator

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Butterfly valves PN 16

VE-S_15-32 Pressure Independent Balancing & Control Valves

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

VA-4233-GGx Series Electric Valve Actuators

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Modulating control valves with magnetic actuator PN 16

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Zone Valves and Parts (Honeywell)

Differential pressure sensor

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Differential Pressure Sensors

3-port seat valves PN16 with flanged connection

Differential Pressure Sensors

Actuators for Fire and Smoke Protection Dampers

Type A - PICV Actuator Series

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Butterfly valves PN 16

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Power consumption In operation At rest For wire sizing

3-port seat valves PN10 with flanged connection

Actuators for Fire and Smoke Protection Dampers

MS Application. Features. Proportional Valve Actuator General Instructions

3-port seat valves PN16 with flanged connection

3-Port Seat Valves with Male Thread, PN 16

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

2. A E LM Form-fit versions Linear adapter ZH-LM

Commercial Actuator Selection Chart Non-Spring Return

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Transcription:

Actuators for small valves with 5.5 mm nominal stroke 4 891 SSB31... SSB81... 80130 80117 SSB... without auxiliary switch SSB...1 with auxiliary switch Electro-mechanical actuators for valve types VMP45..., VVP45... and VXP45... Nominal stroke 5.5 mm Automatic stroke recognition 3-position or DC 0 10 V control signal AC 24 V or AC 230 V operating voltage Direct assembly with union nut (no tools required) Can be operated manually Optional auxiliary switch AC 250 V / 1(0.5) A, with adjustable switching point 0...100 % Plug-in cable for supply voltage and control signal Parallel connection of multiple actuators possible With position indicator Use For use in fan-coil systems, induction units and chilled-ceiling systems, to operate heating or cooling valves. Functions The DC 0...10 V control signal or the 3-position control voltage generates a stroke in the actuator which is transmitted to the valve stem. SSB31... / SSB81... (3-position control) (DC 0...10 V control signal) Voltage at Y1: Valve opens Voltage at Y2: Valve closes No voltage at Y1 and Y2: Valve remains in current position. The valve opens in proportion to the voltage at Y. At 0 V, the valve is closed. Type summary Auxiliary switches The basic types are supplied with a 1.5 metre cable. Actuators may also be ordered without a cable (type codes ending in.../00). A long connecting cable (4.5 m, see Accessories ) can be ordered for these. The SSB31... and SSB81... actuators are also available with auxiliary switches. Actuator types SSB31.1... and SSB81.1... have a built-in auxiliary switch. The switch cannot be fitted later. Siemens Building Technologies CA1N4891E / 01.2000 Landis & Staefa Division 1/6

Type summary (cont d) Accessories Ordering Compatibility Type Operating voltage Running time at 50 Hz Control signal Cable length Built-in aux. switch SSB31 AC 230 V 150 s 3-position 1.5 m No SSB81 AC 24 V 150 s 3-position 1.5 m No SSB81U AC 24 V 150 s 3-position Connection No terminals SSB61 AC 24 V 75 s DC 0...10 V 1.5 m No SSB61U AC 24 V 75 s DC 0...10 V Connection No terminals SSB31.1 AC 230 V 150 s 3-position 1.5 m Yes SSB81.1 AC 24 V 150 s 3-position 1.5 m Yes SSB31/00 AC 230 V 150 s 3-position No cable No SSB81/00 AC 24 V 150 s 3-position No cable No SSB61/00 AC 24 V 75 s DC 0...10 V No cable No SSB31.1/00 AC 230 V 150 s 3-position No cable Yes SSB81.1/00 AC 24 V 150 s 3-position No cable Yes ASY3L45 Connecting cable AC 230 V, 3-position Length 4.5 m ASY6L45 Connecting cable AC 24 V, DC 0...10 V Length 4.5 m ASY8L45 Connecting cable AC 24 V, 3-position Length 4.5 m ASY98 Retaining screw for connector When placing an order please state the quantity, product name and type code. Items are supplied individually packed (except SSB61U and SSB81U, see note below). Example 2 actuators without cables, type SSB81/00 and 2 connecting cables, type ASY8L45 Actuator types SSB61U and SSB81U are available only in packs of 10 (minimum order quantity). The electro-mechanical actuators are suitable for use in conjunction with the following 2-port and 3-port valves with a nominal stroke of 5.5 mm : Valve type k vs [m 3 /h] Nom. pressure Data sheet VVP45... 2-port valves 0.25... 6.3 VXP45... 3-port valves 0.25... 6.3 PN16 N4845 VMP45... 3-port valves with integral T-bypass VMP43...(2) 2-port valves 0.25... 4 VMP43... 3-port valves 0.25... 2.5 PN16 N4841 VMP43...(4) 3-port valves with integral T-bypass Mechanical design The actuator and valve are supplied separately. They are assembled with a union nut, requiring no tools or adjustments. In the case of actuators with auxiliary switches, the switch is connected to terminals and must be wired separately. CA1N4891E / 01.2000 Siemens Building Technologies 2/6 Landis & Staefa Division

Features Plastic housing Stall-proof gear unit, no maintenance required Plug-in connecting cable, length 1.5 m Non-interchangeable AC 24 V and AC 230 V sockets Manual adjustment with 3 mm Allen key Reduced current consumption in stop positions Force-dependent switch-off in the event of overload, and in stroke end-positions. Up to 6 SSB31 or SSB81 or up to 10 SSB61 actuators may be operated in parallel. 80117 Engineering notes Mounting Note the admissible temperatures (see sections on Use and Technical data ). The connecting cable will not be damaged by contact with the valve body as long as the valve body temperature does not exceed 80 C. Mounting instructions are printed on the packing. Orientation 80129 Permissible NOT permissible Commissioning When commissioning, check the wiring and the functioning of the actuator and auxiliary switch, if fitted. Spindle extended (movement from Mark 0 to 1) valve opens. Spindle retracted (movement from Mark 1 to 0) valve closes. Caution The calibrates itself (calibration stroke) during commissioning. Correct functioning cannot be guaranteed if the SSB is operated without a valve. Operating The actuators can be driven manually to any position between 0 and 1 with a 3 mm Allen key. A control signal from the controller, however, will take priority over any manual position. Note To hold the actuator in the manually-set position, the connecting cable must be unplugged. A B 3 mm 80119 Manual adjustment with Allen key 80120 80121 3 mm 3 mm B A Position indicator at Mark 0 = CLOSED Position indicator at Mark 1 = OPEN Siemens Building Technologies CA1N4891E / 01.2000 Landis & Staefa Division 3/6

Maintenance! When servicing the actuator note the following: Switch off the operating voltage. Where applicable, disconnect electrical connections from the terminals. The valve must be mounted in accordance with instructions before commissioning the actuator. Technical data Supply voltage Control Auxiliary switch (optional) Applies to all types: General ambient conditions SSB31... SSB81... Operating voltage AC 230 V ±15 % AC 24 V ± 20 % AC 24 V ± 20 % DC 24 V ± 25 % Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Power consumption 6 VA 0.8 VA 2.0 VA Control signal 3-position 3-position DC 0...10 V Input impedance for DC 0...10 V --- --- > 10 kohm Position accuracy --- --- < 2 % of nominal stroke Max. no. of parallel connected actuators 6 6 10 Switch type 1 SPDT 1 SPDT Switching point adjustable at 0...100 % 0...100 % Switching capacity of auxiliary switches AC 250 V, 1 A resistive, 0.5 A inductive Running time for 5.5 mm stroke 150 sec 150 sec 75 sec Nominal stroke 5.5 mm Nominal force > 200 N Standard connecting cable (actuator) 3-core, length 1.5 m or 4.5 m Weight of actuator without / with auxiliary switch 0.3 kg / 0.4 kg Operation To IEC721-3-3 Class 3K3 : 1 C... 50 C and 5...85 %rh. Transport To IEC721-3-2 Class 2K3 : 25 C...+70 C and max. 95 %rh. Storage To IEC721-3-1 Class 1K3 : 5 C...+ 50 C and 5...95 %rh. Admissible temperature of medium (in valve) +1... +110 C Safety With AC 24 V operating voltage With AC 230 V operating voltage Housing protection standard To EN 60730 Section 2.7 : Protection class III To EN 60730 Section 2.7 : Protection class II IP40 CE marking Complies with the requirements for CE marking in accordance with: EMC Directive 89/336/EEC Low Voltage Directive 73/23/EEC Connecting cable SSB31... Y1 6 Black 80122 Control voltage, OPEN (AC 230 V) N 4 Y2 7 Blue White Neutral (neutral conductor) Control voltage, CLOSE (AC 230 V) SSB81... Y1 6 Purple 80123 Control voltage, OPEN (AC 24 V) G 1 Red Phase (AC 24 V) Y2 7 Orange Control voltage, CLOSE (AC 24 V) G0 2 Black 80124 System neutral G Y 1 8 Red Grey Phase (AC 24 V) Control signal DC 0...10 V CA1N4891E / 01.2000 Siemens Building Technologies 4/6 Landis & Staefa Division

SSB31.1 and SSB81.1 : Terminals for auxiliary switches Q14 Q12 Q11 80125 Do not exceed the max. loads for the SPDT contacts: Max. AC 250 V Max. 1 A resistive Max. 0.5 A inductive Q11 Q12 closed and Q11 Q14 open: Æ Valve > 0 % OPEN. Adjustable switching point. Q11 Q12 open and Q11 Q14 closed: Æ Valve 0 % = CLOSED The switching point can be adjusted by turning the switching cam with a screwdriver (instructions enclosed with packaging). Dimensions Without auxiliary switch All dimensions in mm SSB31... SSB81... 80126 81.4 72.5 48 83 With auxiliary switch SSB31.1... SSB81.1... 80127 98.5 89.5 48 83 Siemens Building Technologies CA1N4891E / 01.2000 Landis & Staefa Division 5/6

1998 Siemens Building Technologies Ltd. Subject to technical alteration CA1N4891E / 01.2000 Siemens Building Technologies 6/6 Landis & Staefa Division