STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

Similar documents
STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENERATOR SET FEATURES

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1800 ekw 2250 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 225 ekw 281 kva

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Caterpillar 2500 kw 3516C

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

CONTINUOUS 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

220 to volts. Electronic unit injection

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

Specifications. 3406C Generator Set Electric Power

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Standby 500 ekw 625 kva 60 Hz 1800 rpm 480 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

STANDBY 4000 ekw 5000 kva 60 Hz 1800 rpm 4160 Volts

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 200 ekw 250 kva

Prime 455 ekw kva 60 Hz 1800 rpm 480 Volts

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Transcription:

DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm 11 000 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES FUEL/EMISSIONS STRATEGY Low Fuel consumption DESIGN CRITERIA The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response. FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat S O S SM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT 3516 TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT HV GENERATOR Matched to the performance and output characteristics of Cat engines Single point access to accessory connections UL 1446 Recognized Class F insulation CAT EMCP 4 CONTROL PANELS Simple user friendly interface and navigation Scalable system to meet a wide range of customer needs Integrated Control System and Communications Gateway

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Service indicator [ ] Dual element & heavy duty air cleaners [ ] Air inlet adapters & shut-off Cooling Radiator with guard Coolant drain line with valve Radiator fan and fan drive Fan and belt guards Cat Extended Life Coolant* Coolant level sensors [ ] Duct flange [ ] Heat exchanger and expansion tank [ ] Coolant level switch gauge [ ] Jacket water heater Exhaust Fuel Power Termination Generators Dry exhaust manifold Flanged faced outlets Secondary fuel filters Fuel priming pump Flexible fuel lines Fuel cooler* Bus bar (NEMA mechanical lug holes) Right hand cable entry Top or bottom cable entry Class F insulation Cat digital voltage regulator (CDVR) with kvar/pf control, 3-phase sensing Winding temperature detectors Anti-condensation heaters [ ] Mufflers and Silencers [ ] Stainless steel exhaust flex fittings [ ] Elbows, flanges, expanders & Y adapters [ ] Water separator [ ] Duplex fuel filter [ ] Primary Fuel Filter [ ] Left hand cable entry [ ] Oversized generators [ ] Cross current compensation transformer Governor Woodward 2301 isochronous [ ] Load share governor Control Panel EMCP 4.2 User Interface panel (UIP) - rear mount AC & DC customer wiring area (right side) Emergency stop pushbutton Lube Mounting Starting/Charging General Lubricating oil Gear type lube oil pump Oil filter, filler and dipstick Oil drain lines and valve Fumes disposal Rails - Engine / generator / radiator mounting Rubber anti-vibration mounts (shipped loose) 24 volt starting motor(s) Batteries with rack and cables Battery disconnect switch Right hand service Paint - Caterpillar Yellow (with high gloss black rails & radiator) SAE standard rotation Flywheel and flywheel housing - SAE No. 00 [ ] Option for right or left mount UIP [ ] Local & remote annunciator modules [ ] Digital I/O Module [ ] Generator temperature monitoring & protection [ ] Remote monitoring software [ ] Oil level regulator [ ] Deep sump oil pan [ ] Electric & air prelube pumps [ ] Manual prelube with sump pump [ ] Duplex oil filter [ ] Isolator removal [ ] Spring-type vibration isolator (shipped loose) [ ] Battery chargers (10 or 20 amp) [ ] 45 amp charging alternator [ ] Oversize batteries [ ] Ether starting aid [ ] Heavy duty starting motors [ ] Barring device (manual) [ ] Air starting motor with control & silencer [ ] CSA certification [ ] CE Certificate of Conformance [ ] Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007 * Not included with packages without radiators 2

SPECIFICATIONS CAT GENERATOR Cat HV Generator Frame size... 2750 Excitation... Permanent Magnet Pitch... 0.6670 Number of poles...4 Number of bearings... 2 Number of Leads... 006 Insulation... Class H with tropicalization and antiabrasion Insulation...Class F with tropicalization and antiabrasion - Consult your Caterpillar dealer for available voltages IP Rating... IP23 Alignment...Closed Coupled Overspeed capability...125 Wave form Deviation (Line to Line)... 002.00 Voltage regulator...3 Phase sensing with volts/hz Voltage regulation...less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) Telephone influence factor...less than 50 Harmonic Distortion...Less than 5% CAT DIESEL ENGINE 3516 TA, V-16, 4-Stroke Water-cooled Diesel Bore... 170.00 mm (6.69 in) Stroke... 190.00 mm (7.48 in) Displacement...69.00 L (4210.64 in 3 ) Compression Ratio... 13.5:1 Aspiration... TA Fuel System...Mechanical unit injection Governor Type... Woodward CAT EMCP 4 SERIES CONTROLS EMCP 4 controls including: - Run / Auto / Stop Control - Speed and Voltage Adjust - Engine Cycle Crank - 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions Digital indication for: - RPM - DC volts - Operating hours - Oil pressure (psi, kpa or bar) - Coolant temperature - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - ekw, kva, kvar, kw-hr, %kw, PF Warning/shutdown with common LED indication of: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Programmable protective relaying functions: - Generator phase sequence - Over/Under voltage (27/59) - Over/Under Frequency (81 o/u) - Reverse Power (kw) (32) - Reverse reactive power (kvar) (32RV) - Overcurrent (50/51) Communications: - Six digital inputs (4.2 only) - Four relay outputs (Form A) - Two relay outputs (Form C) - Two digital outputs - Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - Emergency stop pushbutton Compatible with the following: - Digital I/O module - Local Annunciator - Remote CAN annunciator - Remote serial annunciator 3

TECHNICAL DATA Open Generator Set - - 1500 rpm/50 Hz/11 000 Volts Low Fuel Consumption DM7961 Generator Set Package Performance Genset Power rating @ 0.8 pf Genset Power rating with fan 2000 kva 1600 ekw Coolant to aftercooler Coolant to aftercooler temp max 82 C 180 F Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System 1 Air flow restriction (system) Air flow (max @ rated speed for radiator arrangement) Engine Coolant capacity with radiator/exp. tank Engine coolant capacity Radiator coolant capacity 419.1 L/hr 110.7 Gal/hr 315.8 L/hr 83.4 Gal/hr 224.4 L/hr 59.3 Gal/hr 0.12 kpa 0.48 in. water 1543 m³/min 54491 cfm 398.0 L 105.1 gal 233.0 L 61.6 gal 165.0 L 43.6 gal Inlet Air Combustion air inlet flow rate 124.5 m³/min 4396.7 cfm Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to aftercooler Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 490.3 C 914.5 F 333.0 m³/min 11759.8 cfm 203.2 mm 8.0 in 6.7 kpa 26.9 in. water 1051 kw 59770 Btu/min 1527 kw 86840 Btu/min 234 kw 13308 Btu/min 166 kw 9440 Btu/min 71.9 kw 4088.9 Btu/min 3928 skva 2750 130 C 234 F Lube System Sump refill with filter 401.3 L 106.0 gal Emissions (Nominal) 3 NOx mg/nm3 CO mg/nm3 HC mg/nm3 PM mg/nm3 6743.6 mg/nm³ 354.7 mg/nm³ 104.2 mg/nm³ 34.1 mg/nm³ 1 For ambient and altitude capabilities consult your Cat dealer. Air flow restriction (system) is added to existing restriction from factory. 2 UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32. 3 Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM, NOx. Data shown is based on steady state operating conditions of 77 F, 28.42 in HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility and engine to engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Standby - Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Standby power in accordance with ISO8528. Fuel stop power in accordance with ISO3046. Standby ambients shown indicate ambient temperature at 100% load which results in a coolant top tank temperature just below the shutdown temperature. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Cat representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. 5

DIMENSIONS Package Dimensions Length 6233.2 mm 245.4 in Width 2286.0 mm 90 in Height 2342.0 mm 92.2 in Weight 17 909 kg 39,483 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #2748728). Performance No.: DM7961 Feature Code: 516DE4A Gen. Arr. Number: 2524230 Source: U.S. Sourced July 26 2011 17793027 6 www.cat-electricpower.com 2011 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.