High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.

Similar documents
HCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically.

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

CMP/EW EFFICIENT WORK

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

CMR/EW EFFICIENT WORK

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

INDUSTRIAL BRUSHLESS MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Centrifugal medium-pressure fans fitted with multi-blade

Fans for ATEX EXPLOSIVE ATMOSPHERES

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

HIGH-POWERED VENTILATORS

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

COMPACT Series type HCFB / HCFT (Plastic impellers)

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Medium Pressure Centrifugal Fans

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Plate mounted axial flow fans HXBR / HXTR Series

CRL. MADE OF SHEET STEEL TURBINE WITH REACTION BLADES LOW NOISE LEVEL IE3 > 0.75kw MOTORS ENERGY SAVING MOTORS CRL MEDIUM PRESSURE CENTRIFUGAL FANS

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

UDT UDTX FILTRATION UNITS AND AIR TREATMENT MODULES

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CGT Series Adjustable Pitch Fans

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

CGT Series Adjustable Pitch Fans

CHMT Series, F Rated Fans

ACOUSTIC CABINET FANS CVAB / CVAT Series

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CENTRIFUGAL IN-LINE FANS VENT Series

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

RECUP/LC HEAT RECOVERY UNITS F7 F7 R.I.T.E. Reglamento de instalaciones térmicas en edificios

FRF FRF/EW ROOF-MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH VERTICAL AIR OUTLET

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

DIRECT-AIR ILB / ILT Series Rectangular duct fans

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Energy-saving motors (ESM)

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

AXIAL FLOW CABINET FAN CGT Series

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

MAJAX-2 GENERAL SPECIFICATION

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Mixed Flow Roof Fans (RMH)

CJSX-SILENT 400º/2H BELT-DRIVEN EXTRACTION UNITS SOUNDPROOFED DOUBLE-WALL OF SOUNDPROOFING 40 MM THICK

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

ACOUSTIC CABINET FANS CVB / CVT Series

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Bifurcated Case Axial Fans (BIFA)

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Uniclass L7534. Manufacture controlled to ISO9001

SILENT MV Ultra Quiet In-line Fans

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

BOX BLB Centrifugal Box Fan

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Square Mixed Flow Fans (MFQ)

Short casing. Long casing (L version) Commercial premises

WINDER. Impellers with higher efficiency and less sound level

BATHROOM EXTRACT FANS DECOR-100 Series

NEW Slimpak EC Box Fan (SLPT EC)

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

Benefits of EC Motor Technology for Automotive Air Handling

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

CYLINDRICAL CASED AXIAL FLOW FANS

Performance. Sound Levels. Impellers. Motors. Accessories

Rotron HF/ HFV/ HFG Propeller Fans

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

MIXVENT-TH Series Mixed Flow Fans

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

TD-ECOWATT AND DECOR-ECOWATT Series

Transcription:

HEPT/EW with High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. BRUSHLESS MOTOR BRUSHLESS INDUSTRIAL E.C. Fibreglass-reinforced plastic impeller. Fan: Airflow direction from motor to impeller. Impeller in polyamide 6 reinforced with fibreglass. Sheet steel long casing. Electronic variable speed (), three-phase or single-phase, is supplied with fan. VARIABLE SPEED DRIVE : Variable Speed Drive.. 1/B. 3/B Supply included with fan CONTROL Supply optional accesory SUPPLY 1/B: 220-240 V 50/60 Hz 3/B: 380-415 V 50/60 Hz Motor and electronic variable speed: High-efficiency Industrial Brushless Motors E.C., fitted with electronic variable speed (), adjustable via external control input 0-10V. IP65 protection. It is advisable to install an electronic variable speed drive () outside the working area. The external signal can be supplied through a manual or automatic control with 0-10 V output. Electronic variable speed drive (), available with single-phase 220-240 V 50/60 Hz input (1/B type) or three-phase 380-415 V 50/60 Hz (3/B type). Standard protection IP20, on demand IP66 protection. By default, the electronic variable speed drive () is delivered programmed for constant speed. Working fan temperature: -25 ºC +60 ºC. Working temperature (): -25 ºC +50 ºC. Finish: Anticorrosive finish in polyester resin polymerised at 190ºC, after alkaline degreasing with nanotechnology treatment and phosphate-free. On request: Motor, impeller and guard unit (version F) Airflow direction from impeller to motor. Order code with variable speed drive () included HEPT/EW 31 2/H B T D HEPT/EW: High-efficiency long-cased axial fans, Efficient work Impeller diameter in cm. speed: 2=2850 rpm 4=1410 rpm 6=960 rpm H=High airflow L=Low airflow M: Fitted with 1/B, Industrial electronic variable speed, Brushless single phase power supply Motors E.C. 220-240 V 50/60 Hz. T: Fitted with 3/B, electronic variable speed, three-phase power supply 380-415 V 50/60 Hz. D: Standard version, supplied programmed for constant speed. P: Supplied with programmed for pressure control and Si-Presión pressure transmitter K: Supplied with programmed for pressure control and built into a BOXPRES KIT/B box. Technical characteristics Speed (r/min) Single-phase 230 V50/60 Hz Three-phase 400 V50/60 Hz electrical power Airflow Sound pressure level Weight approx. (W) (m 3 /h) db(a) (Kg) HEPT/EW-31-2/H 300 / 2850 2.86 1/B-0.37 0.84 3/B-0.75 345 420 / 4000 25 / 74 7.4 HEPT/EW-31-4/H 300 / 1410 1.14 1/B-0.37 0.34 3/B-0.75 140 510 / 2400 21 / 55 6.2 HEPT/EW-35-2/H 300 / 2850 4.08 1/B-0.37 1.20 3/B-0.75 495 635 / 6020 27 / 76 9.4 HEPT/EW-35-4/H 300 / 1410 1.14 1/B-0.37 0.34 3/B-0.75 140 745 / 3500 24 / 58 7.6 HEPT/EW-40-4/H 300 / 1410 2.79 1/B-0.37 0.82 3/B-0.75 340 1105 / 5200 27 / 61 13.5 HEPT/EW-40-6/H 300 / 960 2.13 1/B-0.37 0.62 3/B-0.75 255 1095 / 3500 29 / 54 13.5 HEPT/EW-45-4/H 300 / 1410 3.96 1/B-0.37 0.93 3/B-0.75 450 1555 / 7300 32 / 66 15.5 HEPT/EW-45-4/L 300 / 1410 2.79 1/B-0.37 0.82 3/B-0.75 340 1235 / 5810 30 / 64 15.5 HEPT/EW-45-6/H 300 / 960 2.13 1/B-0.37 0.62 3/B-0.75 255 1530 / 4900 31 / 56 15.5 HEPT/EW-50-4/H 300 / 1410 5.82 1/B-0.75 1.37 3/B-0.75 660 2160 / 10150 35 / 69 18.0 HEPT/EW-50-4/L 300 / 1410 2.79 1/B-0.37 0.82 3/B-0.75 340 1555 / 7300 33 / 67 18.0 17

Technical characteristics Speed (r/min) Single-phase 230 V50/60 Hz Three-phase 400 V50/60 Hz electrical power Airflow Sound pressure level Weight approx. (W) (m 3 /h) db(a) (Kg) HEPT/EW-50-6/H 300 / 960 2.13 1/B-0.37 0.62 3/B-0.75 255 1920 / 6150 34 / 59 18.0 HEPT/EW-56-4/H 300 / 1410 7.94 1/B-0.75 1.87 3/B-0.75 905 2725 / 12800 38 / 72 28.0 HEPT/EW-56-4/L 300 / 1410 5.82 1/B-0.75 1.37 3/B-0.75 660 2320 / 10900 36 / 70 28.0 HEPT/EW-56-6/H 300 / 960 2.93 1/B-0.37 0.68 3/B-0.75 330 2580 / 8250 37 / 62 28.0 HEPT/EW-63-4/H 300 / 1410 11.25 1/B-0.75 2.65 3/B-1.5 1295 3980 / 18700 48 / 82 33.5 HEPT/EW-63-4/L 300 / 1410 7.94 1/B-0.75 1.87 3/B-0.75 905 3510 / 16500 41 / 75 33.5 HEPT/EW-63-6/H 300 / 960 4.28 1/B-0.37 1.00 3/B-0.75 480 3765 / 12050 40 / 65 33.5 Acoustic features at maximum speed The specified values are determined according to free field measurements of pressure and sound levels in db(a) at an equivalent distance of twice the fan s span plus the impeller s diameter, with a minimum of 1.5 m. Sound power Lw(A) spectrum in db(a) via frequency band in Hz. 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 HEPT/EW-31-2/H 49 62 74 78 80 80 76 68 HEPT/EW-31-4/H 30 43 55 59 61 61 57 49 HEPT/EW-35-2/H 51 64 76 80 82 82 78 70 HEPT/EW-35-4/H 33 46 58 62 64 64 60 52 HEPT/EW-40-4/H 36 49 61 65 67 67 63 55 HEPT/EW-40-6/H 29 42 54 58 60 60 56 48 HEPT/EW-45-4/H 43 57 69 72 74 75 71 62 HEPT/EW-45-4/L 41 55 67 70 72 73 69 60 HEPT/EW-45-6/H 33 47 59 62 64 65 61 52 HEPT/EW-50-4/H 46 60 72 75 77 78 74 65 HEPT/EW-50-4/L 44 58 70 73 75 76 72 63 HEPT/EW-50-6/H 36 50 62 65 67 68 64 55 HEPT/EW-56-4/H 49 63 75 78 80 81 77 68 HEPT/EW-56-4/L 47 61 73 76 78 79 75 66 HEPT/EW-56-6/H 39 53 65 68 70 71 67 58 HEPT/EW-63-4/H 61 75 87 90 92 92 89 80 HEPT/EW-63-4/L 54 68 80 83 85 85 82 73 HEPT/EW-63-6/H 44 58 70 73 75 75 72 63 Dimensions in mm A B D E J Drills No. HEPT/EW-31 385 355 308 200 10 8 HEPT/EW-35 425 395 360 220 10 8 HEPT/EW-40 490 450 410 220 12 8 HEPT/EW-45 540 500 460 220 12 8 HEPT/EW-50 600 560 514 230 12 12 HEPT/EW-56 660 620 560 260 12 12 HEPT/EW-63 730 690 635 350 12 12 See HEP/EW-HEPT/EW model characteristic curves Accessories See accessories section. INT PL P PT/H RI RT BTUB BAC PS S CONTROL UNITS AND SENSORS 18

19

20

21