The future of soft start motor control at your fingertips

a revolution in soft start motor control The future of soft start motor control at your fingertips

Game changing soft starters

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

Guide to the Application of Soft Starters

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Starts, stops and protects. Emotron TSA Softstarter

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry.

Synergy EN product information

Pocket Guide VLT Soft Starter the single speed drive

A softstarter beyond the ordinary

An Engineering Guide to. Soft Starters

SIRIUS Soft Starters Introduction

Pocket Guide VLT Soft Starter the single speed drive

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Section 0.0 Warnings... 2 Section 1.0

Panorama. Softstarters The complete range

Principles of iers (intelligent

PCS compact soft starters

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

4491 en / c. D IGISTART et. Reference guide

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Contents. MCD 200 Design Guide. Contents

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

Selection Guide for SMC-Delta and SMC-3. A New Dimension in Motor Control

Complete Range of Soft Start / Motor Control, Motor Protection & Control Solutions

CTi Automation - Phone: Fax: Web:

USERS MANUAL MCD REMOTE OPERATOR

AuCom - Soft Starters

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB


1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

Micro Controller based Motor Protection Relay & Motor Management System

MCD 200 Series Soft Starters

Sullair: An Industry Leader

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

How to Select a Variable Frequency Drive Based on Load Characteristics

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Features and Benefits. Control Features

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

Softstarters Type PSS. Softstarters. General information

AURORA Soft Starters LPRA & LPRB series

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Soft Starters and Energy Optimising Soft Starters Guide to contents - applicable to

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

Sullair: An Industry Leader

Benefits of using the Eaton S811+ soft starter to improve uptime and lower maintenance costs

ROBICON W120 enclosed drive

Low cost, internally bypassed non optimizing soft starter

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

RVS-DN Instruction Manual

Softstarters Softstarters

AUCOM NORTH AMERICA. Complete range of motor starting solutions

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

KSL VARIABLE FILL FLUID COUPLINGS

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Application example of a motor controlled by MCD100 and protected by a circuit breaker

130 KW / 165 KVA POWERED by

Guide to contents - applicable to

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor management system TeSys T Give your motor starters a sixth sense!

Technical Data Sheets

Technical Data Sheets

700 KVA / 550 KW POWERED by

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

2018 PRODUCT GUIDE Discover: The Solcon Data Logger Expanded istart Ratings Solcon s Full Line of Motor Protection

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

RVS-DX Digital Reduced Voltage Motor Starter

Innovation in soft start technology. agility USER MANUAL. MAN-AGY-001. Version 01

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

MOTOR CONTROL IS OUR NATURE PRODUCT GUIDE

Owl Energy Technologies, Inc. Motor Control Division. Application Brief

Softstarters PSR PSS PST Extreme duty

Motor Starters, Soft Starters and Load Feeders

Section 9: Gearboxes: Series F

Motor Starters, Soft Starters and Load Feeders

Motor Starters, Soft Starters and Load Feeders

SOLID STATE RELAYS Optically Isolated, Zero Over or Instant Triggering Control Voltage: 3-32 VDC / VAC

Product brochure. Medium voltage AC drive ACS2000, kw, kv

Product Overview. Soft Starters Motor Protection Control and Measurement. Solcon Industries Ltd.

Distributed intelligence

Technical Data Sheets

Series Motor Protection

300 KW / 375 KVA POWERED by

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Transcription:

The future of soft start motor control at your fingertips

As the original pioneers of soft start technology Fairford have been at the forefront of motor control innovation since the 1970 s. A major designer and manufacturer of soft start motor control solutions Fairford have manufactured and supplied 1,000,000 s of products into the market place and are recognised as the reference point for many control solution providers worldwide. synergy is an innovative form of motor control that bridges the gap between a drive and a soft starter. With the increasing pressure on industry to lower its energy consumption and increase systems efficiency, synergy has been developed to meet these requirements. In addition, synergy utilises Fairford s globally renowned automatic setup feature which allows the user to programme the unit to each individual application using a simple 8 button process. Not only that but in order to keep pace with modern technology and a fast growing market, buttons are replaced with a touch screen to bring the user interface to even greater management levels. With built in full motor overload protection as well as full data logging, field serviceable, upgradeable software, extensive input/output programmability synergy meets all of the industrial fixed speed criteria. More importantly it redefines motor control solutions as we have previously known them. iers intelligent Energy Recovery System iers is an advanced motor control technology for use in fixed speed applications. It is proven to reduce the energy consumed in a variety of industrial and commercial applications and has been implemented in every market from HVAC to Oil and Gas. In the industrial sector it is becoming increasingly important to offer technology that meets the corporate social responsibilities of companies as well as reducing the overall running costs of equipment and minimising downtime and maintenance. When the power factor drops, the motor is lightly loaded, and there are losses inherent in the design of a motor causing excess energy to be wasted. These are known as excitation losses. iers s consistent monitoring automatically recognises these costly losses, and in turn reduces the voltage and current, to not only increase the part load power factor, but reduce the energy consumption in kw. When the power factor increases, the motor is more loaded. iers then automatically bypasses itself to remove any losses within the equipment. iers is a technology that matches the power consumption to the load required. It intelligently monitors and regulates energy consumption on fixed speed motors. It also monitors the voltage, current and power factor during the start to calculate the full load figures. During the running stage, the power factor continues to be monitored.

synergy specification for sizes 1, 2 and 3 Range from 17-500A or 10-400HP 3-phase SCR Full motor overload Standard Trip Class 10: 3 x 23 secs or 3.5 x 17 secs - 3 or 5 starts per hour (other Trip Classes are available) 208, 230, 400, 480 volts Allowing for varying frequency 45Hz-65Hz IP20 / NEMA 1, IP00 User-friendly, full colour touch screen Full automatic set up Control voltages of 24VDC, 110/230VAC iers - intelligent Energy Recovery System as standard In Delta / 6 wire connection Multiple languages Modbus RTU as standard Inputs / Outputs: - 4 x programmable output relays - 3 x programmable digital inputs - Analogue input / outputs - USB for data logging and parameter setting/saving - Thermistor Comprehensive data logging Fully field upgradeable Fully field serviceable fans 2 year warranty

Size 1, SGY - 101 to SGY-117 Size 2, SGY - 201 to SGY-205 95.2mm (3.75 ) 143mm (5.62") Size 3, SGY - 301 to SGY - 305 Size 3, SGY - 307 & SGY - 309 205mm (8.07") 205mm (8.07") 435mm (17.12") 490mm (19.30") 470mm (18.50") 435mm (17.12") 494mm (19.45") 470mm (18.50") 270mm (10.63 ) 260mm (10.25 ) 305mm (12.00") 318mm (12.51") 60mm (2.375 ) 177.1mm (6.97 ) 80mm (3.14") 232mm (9.13") SGY-101 to SGY-105 lower fan only Weight = 3.50 kg (7.71 lbs) Weight = 6.50 kg (14.33 lbs) 160mm (6.30") 60mm (2.36") Weight = 16.00 kg (35.27lbs) 164mm (6.45") 310mm (12.20") 160mm (6.30") 60mm (2.36") Weight = 21.20 kg (46.73lbs) 168mm(6.63") 310mm (12.20")

Application Trip Class Default 10 Heavy 20 Agitator 10 Compressors Centrifugal 20 Reciprocating 20 Rotary Screw 20 Rotary Vane 10 Scroll 10 Ball mill 20 Centrifuge / Decanterbowl / Separator - extended start needed for sizing Motor FLC x 2.3 class 30 Bow Thruster Zero Pitch 10 Loaded 20 Conveyor Unloaded 10 Loaded 20 Crusher 30 Fan Low Inertia <85A 10 High Inertia >85A 30 Feeder - screw 10 Grinder 20 Hammer mill 20 30 Application Trip Class Lathe machines 10 Mills - flour Etc 20 Mixer Unloaded 10 Loaded 20 Moulding Machine 10 Pelletizers 20 Plastic and textile machines 10 Press, flywheel 20 Pump - Submersible Centrifugal 10 Rotodynamic 10 Pump - Positive Displacement Reciprocating 20 Rotary 20 Pump Jack 20 Rolling mill 20 Roots Blower 20 Saw Band 10 Circular 20 Screen - vibrating 20 Shredder 30 Transformers, voltage regulators 10 Tumblers 20 Wood chipper 30 Sizing Guide Minimum current ratings based on typical rated operation currents of motors for the corresponding rated operational powers. Current rating optimised for kw@400v & hp@440-480v - Ref IEC 60947-4-1:2009 Table G.1 In Line In Delta Trip Class 10 Trip Class 20 Trip Class 30 IEC IEC UL UL IEC IEC UL UL AC-53a AC-53a AC-53a kw 1) HP 2) kw 1) HP 2) 3-23: 90-5 A 3) 400V A 4) 440-480V A 3) 400V A 4) 440-480V 3.5-17:90-5 4-19: 90-5 4-29: 90-5 17 7.5 17 10 29 15 29 20 SGY-101 SGY-103 SGY-105 22 11 21 15 38 18.5 36 25 SGY-103 SGY-105 SGY-107 29 15 27 20 50 22 47 30 SGY-105 SGY-107 SGY-109 35 18.5 34 25 61 30 59 40 SGY-107 SGY-109 SGY-111 41 22 40 30 71 37 69 50 SGY-109 SGY-111 SGY-113 55 30 52 40 95 45 90 60 SGY-111 SGY-113 SGY-115 66 37 65 50 114 55 113 75 SGY-113 SGY-115 SGY-117 80 45 77 60 139 75 133 100 SGY-115 SGY-117 SGY-201 100 55 96 75 173 90 166 125 SGY-117 SGY-201 SGY-203 For more information on how synergy from Fairford can help you, please visit www.fairford.com/ synergy 132 75 124 100 229 110 215 150 SGY-201 SGY-203 SGY-205 160 90 156 125 277 150 270 200 SGY-203 SGY-205 SGY-301 195 110 180 150 338 185 312 250 SGY-205 SGY-301 SGY-303 242 132 242 200 419 220 419 350 SGY-301 SGY-303 SGY-305 302 160 302 250 523 300 523 450 SGY-303 SGY-305 SGY-307 361 200 361 300 625 355 625 500 SGY-305 SGY-307 SGY-309 430 250 414 350 745 425 717 500 SGY-307 SGY-309 SGY-401 500 280 477 400 866 500 826 600 SGY-309 SGY-401 SGY-403 For more information on synergy contact your local distributor: + 44 (0)1752 894554 www.fairford.com

For more information on synergy contact your local distributor: +44 (0) 1752 894554 www.fairford.com C US CONFORMS TO STD UL 508 CSA 22.2 No. 14 BRO-SGY-001-V01