RED DRAGON ELECTRONIC PROPANE FLARE

Similar documents
OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

MODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets

Propane torch. Model Assembly And Operation Instructions

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

B21 Series BASOTROL Gas Valve

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

Owner s Manual MODEL NO: S400A SERIAL NUMBER 5000

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Safety Pilot System For Vented Gas Logs

#9040 FUEL TANK SWEEPER

KLW4000D Multi-Port Power Pack

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 700 SERIES LEVELING SYSTEM. FEATURING: Touch Panel Leveling Control Air Leveling With Tag Axle Dump

HexPro Series Low Profile Wrenches

Propane Conversion Systems. Installation Instructions: 2S-LIFAN200TM 2S-LIFAN200FM 2S-LIFAN390TM 2S-LIFAN390FM

Operating Manual. Electri-Lite

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

E Series CE Approved Intermittent Pilot Ignition Control

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

PROPANE TORCH WITH TURBO BURNER

Installation Instructions Diesel Nitrous System (#82028)

Low Profile Wrenches Operation and Maintenance Manual

MULTI-FUNCTION JUMP STARTER

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

SECTION 1 2 OPERATION OF INSTRUMENTS AND CONTROLS MR2 U. Keys and Doors. Engine immobiliser system Side doors Power windows...

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

Operating Manual. Safety/Process Flare Pilot

G76x Direct Spark Ignition Controls

Regulated Hose Supply Installation, Operation & Maintenance Manual

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633

INSTRUCTIONS. #82028 Diesel Nitrous System. Thank you for choosing ZEX products; we are proud to be your manufacturer of choice.

Start-up Instructions


VERSA-CUT 60 PLASMA CUTTER

HOT AIR LANCE PART MANUAL Rev. A

24 Volt - 3/8" Cordless Impact Wrench

Models

IBT Series Square Drive Torque Wrenches

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

Hot-Shot Operating Instructions

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

DURA SHOT S SPRAYERS.


Rapid Shrink 100. Owner s Manual

SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W

Items required:- Old Propane Gas Gun, High Pressure regulator, High pressure gas pipe and pipe clips, 12V battery, Propane gas, Tools Etc.

THE MODEL 916/918 HYDRAULIC REAR TINE TILLER

BG1600M Intermittent Pilot Ignition Control

PS MIG Volt MIG Welder Assembly & Operating Instructions

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

original instructions 18V Torch RFP1801

Troubleshooting Manual

Installation Manual. English. French

DSTP20: Fuel Transfer Pump

SAVE THESE INSTRUCTIONS

Cordless Rechargeable Saw Instructions for Use

INSTALLATION INSTRUCTIONS

RMT1201. ORIGINAL INSTRUCTIONS Cordless Multi-Tool

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

18V CORDLESS STAPLER/NAILER

18 KG MOBILE SODA BLASTING UNIT

UNIVERSAL ELECTRA-STEER FOR 2 COLUMN 220w Plain w Polished w Plain w Polished

Installation Instructions

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

TWIN HALOGEN SHOP LIGHT

Operation Guide. Operation Guide. Winnebago Hydraulic Leveling Systems by Kwikee. Introduction. Table of Content WARNINGS

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Air-Operated Waste Oil Drainer

CHALLENGER Propane to Natural Gas Instructions

GEMINI GAS CONTROL PRODUCT INFORMATION

BGD278 Series BASOTROL CE Approved Gas Valve

1080 CF Valve Replacement Instructions

MODEL: 1410-A INSTALLATION AND OPERATION INSTRUCTIONS

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

Poly Electric Drinkers

HIGH QUALITY GAS PRODUCTS SINCE 1957

MULTI FUNCTION POWER PAK PLUS

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

G72x Series Direct Spark Ignition Controls

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

Garden Hose Reel with 3/4In. x 100Ft. Hose. Owner s Manual

OPERATION AND MAINTENANCE MANUAL

! WARNING! Read This Manual Before Operating Equipment

ELECTRIC HYDRAULIC GEAR PUMP

SP6. Automatic Battery Charger. Model

OPERATOR S MANUAL. 20-bu 3-Point Hitch Material Collection System. LP65048 Supplier ST /07/2017 English. North American Edition Printed in USA

Reverse Osmosis System

AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM

Models 8100PP & 86110LP. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

TFL Gas Log Lighter (TFLGLL)

Transcription:

RED DRAGON ELECTRONIC PROPANE FLARE Assembly and Operating Instructions For Models: PF-12 LPS 1/4" Flare 6,900,000 BTU/hr Max PF-14 LPS 3/8" Flare 38,000,000 BTU/hr Max PF-16 LPS 1/2" Flare 48,300,000 BTU/hr Max The RED DRAGON PROPANE FLARE is designed for the evacuation of LP liquid or vapor only. Its use for the evacuation of any other gases or flammable liquids is strongly discouraged and cancels any warranties or perceived responsibility of FLAME ENGINEERING, INC. Read this manual and any other safety-related information before assembling, operating or maintaining your RED DRAGON PROPANE FLARE: Save this manual for future reference. TORCHES & EQUIP. Failure to follow these instructions, local, state, national codes and other instructions provided with this flare equipment may result in serious injury or death. PFLPS Instruction Manual 7-2012

TABLE OF CONTENTS: Important Information and Safety Information...1 Other Required Equipment...1 Component Photos and Descriptions...2 Assembly Instructions...3 Lighting Instructions...5 Shut Down Procedures...5 Trouble Shooting Tips & Other Flaring Rules...6 Parts List...8 PLEASE READ BEFORE GETTING STARTED: The purpose of the Red Dragon Electronic Propane Flare is to provide an efficient process for the evacuation of propane liquid and or vapors from an LP container. It is important to remember a Red Dragon Propane Flare will not completely empty the container. All safety rules, local ordinances, state and federal regulations are to be reviewed and permission granted by the appropriate authority before the flaring of LP cylinders in or near to a populated area. All gas components used in the construction of the Red Dragon Propane Flare are either UL or CSA listed components. NOTE: The Red Dragon Propane Flare is designed for the evacuation of LP gas liquids or gases only. The use of the flare for the evacuation of any other gases or flammable liquids is prohibited and voids any warranties expressed or implied. Qualifications, Codes, Etc. The testing, firing, and the service of this flare equipment requires training and knowledge of LP-Gas and LP-Gas appliances and should not be attempted by anyone who is not qualified. You must completely familiarize yourself with the flare, and its operation by reading and complying with the safety instructions, labels, owner's manual, etc. that is provided with each flare. IMPORTANT SAFETY NOTE: The manual flare is not designed to be operated unattended. OTHER REQUIRED EQUIPMENT NOT INCLUDED WITH THIS FLARE: PILOT FUEL SOURCE A filled LP cylinder with a minimum of 5 gallon capacity (20lb cylinder) is required to provide the pilot torch fuel. A larger cylinder or several 5 gallon cylinders may be required for the complete flaring of a larger propane container. ADJUSTABLE WRENCH Required for attaching the evacuation hoses to valve box, the flare head to the tower and the P.O.L. fitting to the pilot cylinder. GLOVES AND EYE PROTECTION Required for safe assembly & operation of the flare. 3 Cinder Blocks or 3 Sand Bags Required for weighting down tripod if the flare is to be operated on pavement or soft soil where stakes are not sufficient. 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 1

COMPONENT PHOTOS & DESCRIPTIONS: Upper Tower Handle Electrode Box Flare Head/Flare Hose Assembly Evacuation Flare Tube Pilot Torch Upper Tower Flare Head/Hose Assembly Flare Tower Pin (Attached to Pilot Torch Hose) Flare Tube Hose w/ Female Swivel Connection 1/4 Pilot Torch Hose w/ Female Swivel Connection Control Box Receiver Plate Heat Sensor & Ignition Wire 25 Evacuation Tank Hose Assembly Female Swivel Connection Master On Light Master On/Off Switch Flare Tower Pin (Behind Control Box) Electronics Control Box Pressure Gauge Ball Valve Solenoid Control Box Lower Tower Evacuation Tank Fitting Acme Thread LP Fitting For 1/2 Flare Tower Shown Here Pressure Relief Valve 10 1/4 Pilot Cylinder Hose Assembly Leg Guide w/handle 110 Volt Power Cord Pilot Cylinder Hose Assembly Adjustable Regulator Female Fitting Safety P.O.L. Cylinder Fitting Pilot Cylinder (not included) Caribiner Clip Ground Stakes Circle Eyelet For Ground Stakes Tower Base Plate Evacuation Tank Hose Assembly Tripod Leg 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 2

ASSEMBLY INSTRUCTIONS: BEFORE OPERATING THE RED DRAGON PROPANE FLARE: Make sure you have selected a safe area for placement and operation with approximately 40 foot radius and a minimum 50 feet of vertical clearance. A. B. Tee Handle Spring Lock Leg Guide Circle Eyelets 1. Stand the tower in an upright position on the tower base plate. Remove the three Leg Pins that are securing the Tripod Legs and pull the legs free of the storage brackets. (see photos A & B) 2. Pull the tee handle lock of the tripod leg guide. The leg guide will slide down until the tripod legs are at maximum extension. (see photos A,B & C) 3. Pull upward on the lower tower square tubing until the tee handle locks the tripod legs securely. (Test the flare tower position and confirm that the tripod legs cannot be folded. (see photos A & C) Leg Pins D. C. IMPORTANT NOTE: The Eyelets at the end of each tripod leg are to hold the Ground Stakes if the tower is set up on dirt or grass. If using the flare tower on pavement, weight the tripod legs with sandbags or cinder blocks before operating. Evacuation Flare Tube 4. Assemble the electrode box, pilot torch and evacuation flare tube to the receiver bracket on the top of the upper tower using a lock-washer and hex nut. (See Photo D and Diagram 1) Flare Head Receiver Bracket DIAGRAM 1 5. Attach the control box to the control box receiver plate at the top of the lower tower section using the provided wing nuts. (See Photo E) 6. Run the pilot hose and evacuation fuel hose from the torch through the hose secure ring on the upper tower collar and attach them to the appropriate fittings on the left side of the solenoid (bottom) control box. The main evacuation line will connect to the top fitting and the pilot torch line will connect to the bottom fitting. These are flared fittings no need for thread sealant. (See Photo F) 7. Grasp the upper tower square tubing or handle and extend the upper tower to full height and secure with the flare tower pin which is conveniently attached to the pilot torch hose. Check that all hoses remain in their proper hose brackets on the tower. Pilot Torch Electrode Box E. F. 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 3

ASSEMBLY INSTRUCTIONS: H. 8. Arrange the tower so that the tripod leg with the hose bracket is pointing toward the tank being evacuated. Weight the tripod legs with cinder blocks or sand bags if the unit is to be operated on pavement. If the unit is to be operated on dirt or grass, stake each tripod leg down using the leg stakes included with the unit. 9. Attach the Female Swivel Connection on the Pilot Cylinder Hose to the Male Connection on the bottom left male fitting on the bottom of the solenoid control box. Attach the other end of the Pilot Cylinder Hose to the pilot cylinder using the P.O.L. fitting. NOTE: Always use a separate pilot cylinder. Never use the tank being evacuated as the pilot source. Wrench tighten but do not over tighten (remember this is a left hand thread fitting).(see photo G) G. 10. Attach the Female Swivel Connection on the Evacuation Tank Hose to the Male Flared Connection on the bottom right of the Solenoid Control Box. As mentioned before, Teflon or pipe thread sealant is NOT required. (see photo G) Note: Use the caribiner clip to keep the evacuation hose in an orderly manner. (See Photo H) 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 4

RED DRAGON PROPANE FLARE OPERATING INSTRUCTIONS BEFORE OPERATING THE RED DRAGON PROPANE FLARE: Make sure you have selected a safe area for placement and operation with approximately 40 foot radius and a minimum 50 feet of vertical clearance. LIGHTING PROCEDURES Before Starting, Make sure the "Main" switch and the "Remote" switch are in the "OFF" position. 1. Attach pilot hose to an LPG fuel supply with at least five gallon capacity. 2. Attach the main evacuation line to the tank being evacuated. This connection will be either a P.O.L fitting or a commercial tank connection, depending on the model. 3. Slightly open each tank, one at a time, and test for leaks at all connections to the Solenoid Control Box using soapy water or commercial leak testing fluid. Turn off tanks and correct any leaks before continuing. Repeat this step if you have to correct leaks until none are found. 4. Make certain that the main and remote switches are in the "OFF" position. Slowly open each tank valve fully. Connect electrical power cord to a 110 volt A.C. power source. NOTE: The pilot hose is equipped with a safety P.O.L. fitting. If the valve on the pilot fuel container is turned on too quickly, the P.O.L. fitting will check (you may hear a click) just as it would if the hose ruptured. This check valve restricts flow and will result in failure of the pilot to light or result in an insufficient pilot flame. REMEMBER, ALWAYS TURN THE TANK ON SLOWLY! SHUT DOWN PROCEDURES 5. After making certain the remote switch is in the "OFF" position, move the main switch to the "ON" position. The RED indicator light will come on. The pilot torch should now automatically light. NOTE: It is possible you will hear the buzzing sound of the electrical spark attempting to light the pilot burner. The ignition system will cycle in seven seconds. The ignition system will attempt to re-light after a 7 second delay. A third ignition will be attempted. Failure to establish a pilot results in the unit locking out. Should the pilot not achieve ignition, turn the main switch "OFF", wait 30 seconds and start again. It may be necessary to repeat this procedure several times to purge sufficient fuel through the pilot fuel lines. Once the pilot is burning, the system will continue to monitor itself. If the pilot torch goes out, an automatic relight is attempted. If reignition does not occur within 10 seconds, the system will automatically shut down and the operator should start again at step 4 in these instructions. 6. After pilot is ignited, move the remote switch to the "ON" position to start evacuation of the main tank.leak test hose connections from torch and flare tube to the solenoid control box using soapy water or commercial leak detector. 1. Turn the valve off on the tank being evacuated and allow all LP-Gas to escape from the fuel line. 2. Turn the remote switch to "OFF". 3. Close the pilot tank valve. 4. After pilot has burned out, turn main switch to "OFF". 5. Disconnect the unit from the power supply and disconnect hoses from both tanks. 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 5

RED DRAGON PROPANE FLARE OPERATING INSTRUCTIONS CARE AND MAINTENANCE 1. Check all screws on the terminal strips in the electronic control box for tightness before and after each use. Tighten if needed. 2. Store the unit in a dry place to protect the burners and ignition system components. 3. Always leak check all connections before each use and correct as necessary before lighting. DO NOT operate the unit if any leaks are present. TROUBLE SHOOTING TIPS Ignition and Heat Sensor: The ignition and heat sensor electrodes can be sensitive. If unit is not lighting or staying lit, make sure the electrodes have a 90 angle and that the gap between the ignitor and the ground is 1/4". The ignitor and ignitor ground wire should be over the pilot torch bell an 1/8" - 1/4" and the heat sensor wire should just barely cross the edge as shown below. The flare solenoid will only activate when pilot flame is sensed. If flare solenoid fails to activate double check the position of the heat sensor wire and make sure it is positioned as shown below. Ignitor Make Sure The Electrodes are Ignitor Ground Positioned as Shown Here. Approx. 1" Electrode Electrode Box Electrode Heat Sensor Heat Sensor Electrode Box Pilot Torch Ignitor Ground 1/4" Gap Ignitor WARNING: Keep all parts of the body away from the electrodes. This system creates a high voltage spark and can cause injury or death. DO NOT service this unit if you have a pacemaker. Flaring in the Wind: The Red Dragon Flare can operate in winds up to 25 mph. It may be necessary to rotate the flare so the electrodes and heat sensor are situated in the pilot flame but not exposed to the fuel coming from the evacuation flare tube. Evacuation Flare Tube To test the ignition: Make sure both fuel source valves are "CLOSED" (Pilot Tank and Main Fuel Source to be flared). Turn the main switch to "ON" and then turn the remote switch to "ON" and watch for a strong spark between ignitor and ground. If a stong spark is not noticed turn switches off and adjust electrodes as shown in these diagrams. Keep hands and head a safe distance away from the flare head as there may be a small amount of fuel left in the lines. Flaring in the Rain: Flaring may not be possible in rainy conditions. Rain may extinquish the pilot or cool the heat sensor enough to where it will shut-down the flare solenoid. Wind Direction 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 6

RED DRAGON PROPANE FLARE OPERATION INSTRUCTIONS TROUBLE SHOOTING TIPS AND OTHER FLARING RULES TO REMEMBER: Lengthy Flare Jobs and the Pilot Fuel Source: Always use a separate cylinder for the pilot source and have more than one pilot cylinder available for lengthy flaring situations. The pilot fuel source may become empty or drop below 18 P.S.I. and have to be replaced before the tank being evacuated is completely empty. When the pilot tank empties or drops below 18 P.S.I. the pilot will/may quit burning and raw LP gas could be released into the atmosphere. Follow the shut-down procedures and replace the pilot cylinder. Repeat lighting instructions to continue. IMPORTANT NOTE: YOU SHOULD NOT USE THE SAME TANK YOU ARE EVACUATING FOR YOUR PILOT SOURCE. Tank Freeze-Up and the Refrigeration Effect: Tank freeze-up or pressure loss may occur when evacuating vapor withdrawl containers, especially while operating at outside temperatures below 50 F. Pilot containers may also be effected. Frost build up on the outside of the tanks, fittings and hoses are indicators of excessive refrigeration. If the tank being evacuated is losing pressure, yet still contains fuel, you may be required to cease the flaring procedure for a few minutes to let the tank defrost. This effect can and will happen to the fuel tank being evacuated. Other side effects are the flare tube may accumulate frost (the frost in this case contains propane). In the right conditions this frost is flammable. If the pilot tank is losing pressure or freezing up, replace it with a larger cylinder. As the evacuation tank pressure drops, the speed of the process is reduced. The fuel in the LP cylinder is being evacuated and burned at tank pressure. As the fuel is being consumed the pressure in the cylinder will drop. Outside temperature also has a direct effect on tank pressure. Therefore, the flare will not produce 529 gallons per hour consumption up to the very last second. A fuel cylinder being evacuated on an 85 degree Fahrenheit day will flare faster than a fuel cylinder being evacuated on a 40 degree Fahrenheit day. Flaring In Extreme Conditions: Certain components of the Ignition and Solenoid Control Box are not designed to be operated in temperatures exceeding 125 F (54 C) or below -20 F (-32 C). NOTES 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 7

RED DRAGON PROPANE FLARE OPERATING INSTRUCTIONS REPLACEMENT PARTS LIST DESCRIPTION...Part No. FLARE HEAD: Pilot torch/flare tube assembly: For Model PF-12 LPS 1/4" Flare... VT 3-12 PF-12 For Model PF-14 LPS 3/8" Flare... VT 3-12 PF-14 For Model PF-16 LPS 1/2" Flare... VT 3-12 PF-16 Electrode assembly: Electrode (Ignitor and Heat Sensor)...26 Electrode Box and Cover...36 Hi Temp Wire Insulator...26-2 HOSES: 1/4" Pilot Hoses: 65" Hose Solenoid Control Box to Pilot Torch...HP65T 10' Hose Pilot fuel source to Solenoid Control Box... HP10C Flare Hoses: Hose From Solenoid Control Box to Flare Tube For Model PF-12 LPS 1/4" Flare... 65" HP65T For Model PF-14 LPS 3/8" Flare... 72" PFH-72-14 For Model PF-16 LPS 1/2" Flare...60" HP1/2-5TS 25' Hose From Main Tank to Solenoid Control Box For Model PF-12 LPS 1/4" Flare... 25' HP25 For Model PF-14 LPS 3/8" Flare... 25' PFH-25-14 For Model PF-16 LPS 1/2" Flare...25' HP1/2X25S REGULATOR: 25 lb. Preset Regulator For Pilot Tank...567 RC TANK CONNECTIONS: Safety P.O.L. For Pilot Tank Connection...P-3200 W Straight through P.O.L. for 1/4" Flare Line... P-1685 Commercial Tank Connector for 3/8" Flare Line...F-3145 Commercial Tank Connector for 1/2" Flare Line...F-3175 Miscellaneous Parts: Flare Tower Retaining Pin...G-21 Tripod Leg Retaining Pins...G-21-2 (3) Control Box Receiver Plate...PF-TA Electrode (Part # 26) Electrode Box (Part # 36) Pilot Torch/Flare Tube Assembly Ignitor Hi Temp Wire Insulator (Part # 26-2) Ground Heat sensor PRESSURE GAUGE AND PRESSURE RELIEF VALVE: 300 lb. Pressure Gauge for Main Tank... G-25 400 P.S.I. Pressure Relief Valve For Evacuation Hose... H400 CONTROL BOXES AND INDIVIDUAL COMPONENTS: Complete Controls: Electronics Control Box, Solenoid Control Box, Electrode and Remote Switch For PF-12 LPS 1/4" Flare... CS603-12 For PF-14 LPS 3/8" Flare... CS603-14 For PF-16 LPS 1/2" Flare... CS603-16 Electronic Control Box (Top Box) & Electrode Components: Main ON/OFF Toggle Switch... M 3008 Main ON Indicator Light...330 Ignition Control Box... Model 24 Wiring Harness For Ignition Control Box...Model 24W Transformer (output is 24 V / 60 VA)...28 Terminal Connection Strips... 29 & 29-8 Remote Switch with 20' connection wire...pfrs 10' 110 Volt A.C. Power Cord...PFPW 10' Sensor Cable...PFSW 10' Ignition wire...pfiw Electrode (Ignitor and Heat Sensor)...26 Electrode Box...36 Hi Temp Wire Insulator...26-2 Solendoid Control Box Components (Bottom Box): 24 Volt A.C. normally closed solenoid valves: 1/4" Solenoid for pilot on all Solenoid Control Boxes... S-124 1/4" Solenoid for PF-12 LPS 1/4" Flare... S-124 3/8" Solenoid for PF-14 LPS 3/8" Flare... S-125 1/2" Solenoid for PF-16 LPS 1/2" Flare... S-126 Main Switch Terminal Strip Main Indicator Light Pilot Solenoid Flare Solenoid Ignition Control Box Transformer Remote Switch Plug 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com 8

PFLPS Instruction Manual 7-2012 800-255-2469 785-222-2873 Fax 785-222-3619 www.flameengineering.com