Our policy is one of continued research and development. We therefore reserve the right

Similar documents
97100 NAMUR. Technical data

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

HERION SERIES Indirect solenoid actuated soft seal

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

97105 Inline. Ordering information. Technical data. Accessories See page 5

Our policy is one of continued research and development. We therefore reserve the right

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

24010, 3/2 Direct solenoid actuated poppet valve

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Operating pressure (bar) kv factor (m 3 /h) *3)

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

N/** поставка оборудования для подготовки воздуха

Nugget 40, V08 series

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

AUTO STAR with central connector M12x1

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

A robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir.

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

High pressure valves. 80 to 350 bar

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

SBM TECHNOLOGY Cooling / Air Recovery Valve

SBM TECHNOLOGY PET Blow Valve Block

2/2 Pressure operated valves

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

, /2 Soft start ( soft clutch ) valve

Hydraulic pressure switch 20D Acc. to ATEX

Chapter 11: Valves and Actuators with the NAMUR-interface

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Solenoid Valves Type 3963

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

Directional Control Valve Series D3W Soft Shift

Pilot operated solenoid valves for pneumatic actuators

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

AUSTRALIAN PART NUMBERS for SOLENOID VALVES IN AUSTRALIA WE SEPARATELY STOCK VALVES, SOLENOID COILS, AND CONNECTOR PLUGS ETC.

Direct-acting 3/2 way plunger valve

Solenoid Valve Island Type 3965

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot-Operated Directional Control Valves Series D3 - D11

Limit Switch Type 4747

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Directional Control Valve Series D1VW

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

3/2-way Rocker Solenoid Valve for pneumatic systems

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

Valve Islands, V22 Series Sub-base Mounted 2 x 3/2, 5/2 and 5/3 Valves Solenoid Actuated with Wireway

Engineering GREAT Solutions

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

5/2 and 5/3 Way Valves

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

3/2-way Solenoid Valve for pneumatics

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

General Specifications DRV DRV-Exm DRV-Exd

TZIM. Electropneumatic Analog Positioner 10/ EN

Series 3730 Electropneumatic Positioner Type

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

D Series Ex d Stainless Steel

Directional Control Valve Series 4D01 (DENISON)

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

SKINNER Intrinsically Safe Series Four-Way

Chapter 2: Directional Control Valves

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

25000, 4/2 Direct solenoid actuated poppet valves

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

Electronic Limit Switch Type

Pilot operated solenoid valves for pneumatic actuators

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

Pilot Operated Pressure Relief Valve Series R5V (Denison)

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

Type Electronic Limit Switch

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering

Valves For Process Industry. Engineered Pneumatic Solutions.

Transcription:

For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust air recirculation (3 way function) Crossover-free switching, switch-over function guaranteed even with small cross section air supply Safety function in the event of power failure provided by mechanical return spring (monostable design) Reversible seal allows 3/2 or 5/2 way function Manual override with detent Compact design Simple design of soft seal spool system Easily interchangeable solenoid Technical data Medium: Filtered, non-lubricated and dry compressed air Actuation: Solenoid operated, indirectly controlled Flow direction: Fixed Mounting position: Optional Nominal diameter: 6 mm Port size: : G /4, /4 NPT, 3+5: G /8, /8-NPT Electrical connection: Connector interface to DIN 4365 form A and B Operating pressure: Max. 8 bar Temperatures: Valve: -25* to +5 C Solenoid: See solenoid table * With minus temperatures, use conditioned dry air. If installed in the open protect all connections against the penetration of moisture! Material: Housing: Aluminium anodized Pilot flange: Plastic (PBT) Seals: NBR (Perbunan) Ordering example 5/2 directional control valve, port size G /4, solenoid 24 V DC, with connector DIN 4365 form B, Protection class IP 65 Type: 97.35.24. Connectors See data sheet 753364 3/2 5/2 5/3 ) Oil recommendation:: Shell Hydrol DO 32, ESSO Febis K 32 (as of July 992) or comparable oils with DVI-values <8 (DIN 5352) and ISO viscosity class 32-46 (DIN 559). 7/ N/** 5.4.5. to amend, without notice, the specifications given in this document.

3/2, 5/2 and 5/3 directional valves, standard design (3/2 way or 5/2 way function by reversible seal) Symbol Type Port size Actuation Operating Flow Weight Dimensional 3, (5) 2, 4 pressure (bar) (l/min) (kg) drawing 97* G /4 G /8 Flange Solenoid/Spring 2... 8 75,25 M 4 2 97* /4 NPT /8 NPT Flange 97* G /4 G /8 Flange Solenoid/Solenoid 2... 8 75,35 M2 97* /4 NPT /8 NPT Flange 972* G /4 G /8 Flange Solenoid/Solenoid 2... 8 5,4 M3 972* /4 NPT /8 NPT Flange mid position APB * When ordering, please indicate solenoid, voltage and current type (frequency). Valve function: APB = All Ports Blocked Solenoid actuators Type Current draw Protection class Temperature Weight Dimensional Circuit diagram 24 V DC 23 V AC Fluid max. Ambience drawing (W) (VA) ( C) ( C) (kg) 35,7 5,6/4,3 IP w/o connector +5-5... +5,6 M4 SB 35,7 5,6/4,3 IP 65 with connector +5-5,,, +5,8 M4 SB DIN 4365 Form B 336,6 4,55/3,5 IP w/o connector +5-5... +5,9 M5 SB 337,6 4,55/3,5 IP 65 with connector +5-5... +5,2 M5 SB DIN 4365 Form A 342 ) 3,3 EEx m II T5 +8-5... +5,3 M6 SB with cable 3 m 343 ) 3,3 EEx m II T5 +8-5... +5,3 M6 SB8 with cable 3 m Standard voltages 24 V DC, 23 V AC. Other voltages on request. ) Certificate of Conformity PTB No. Ex-95.C.253 X N/** 5.4.5.2 to amend, without notice, the specifications given in this document. 7/

3/2, 5/2 and 5/3 directional valves for minimal electrical power, inkl. EEx i ) (3/2 way or 5/2 way function by reversible seal) Symbol Type Port size Actuation Operating Flow Weight Dimensional 3, (5) 2, 4 pressure (bar) (l/min) (kg) drawing 972* G /4 G /8 Flange Solenoid/Spring 2... 8 75,25 M 4 2 972* /4 NPT /8 NPT Flange 2... 8 75,25 M 972* G /4 G /8 Flange Solenoid/Solenoid 2... 8 75,35 M2 972* /4 NPT /8 NPT Flange 2... 8 75,35 M2 9722* G /4 G /8 Flange Solenoid/Solenoid 2... 8 5,4 M3 9722* /4 NPT /8 NPT Flange mid position APB 2... 8 5,4 M3 * When ordering please indicate solenoid, voltage and current type (frequency). Valve function: APB = All Ports Blocked Outside free of nonferrous metals Solenoid actuators Type Current draw Rated current at Protection class Temperature Weight Dimensional Circuit 24 V DC 23 V AC 24 V DC 23 V AC Fluid max. Ambience drawing diagram (W) (VA) (ma) (ma) ( C) ( C) (kg) 33),7-3 - IP w/o connector +8-5... +5, M5 SB 335,7-3 - IP 65 with connector +8-5... +5, M5 SB DIN 4365 Form A by DC 344 3),9-3 - EEx m II T6 +8-5... +5,4 M6 SB with cable 3 m 345 3) -,9-5 EEx m II T6 +8-5... +5,4 M6 SB8 with cable 3 m Standard voltages 24 V DC, 23 V AC. Other voltages on request. Design acc. to VDE 58, EN 54/528. % duty cycle. For intrinsically safe circuits, protection class EEx ia IIC T6 Type Nom. resistance Required Resistance Required voltage Ambient Fluid temperature Weight Dimensional Circuit RN coil switching current Rw 5 coil at terminal temperature max. (kg) drawing diagram (Ω) (ma) Rw 5 ( C) ( C) 339 4) 275 37 33 2-5... +5 +8,83 M5 SB3 When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account. On the other hand, the low effective inductivity and capacity can be ignored. ) Valves can only be operated with DC solenoids 2) Required connector for DC: type 57275, connector with rectifier for AC or universal current: Type 66333 3) Certificate of Conformity PTB No. Ex-95.C.253 X 4) Certificate of Conformity PTB No. Ex-95.C.252, CSA-Certificate No. LR 59-4, FM approved. Required connector acc. to DIN 4365 or ISO 44. Installation acc. to requirements of FM and CSA. 7/ to amend, without notice, the specifications given in this document. N/** 5.4.5.3

General dimensions valves M 5.5 9.5 M5 3 2 4 M2 5.5 9.5 M5 3 2 4 32 4 3 25 7.2 37.2 3 25 7.2 37.2 3.7 2.5 38.5 56.5 24 2 24.4 8 8 93.2 86.3 24 2 78.8 32 4 3 5 G /4 G /8 3 5 G /4 G /8 M3 5.5 9.5 M5 3 2 4 3 25 7.2 37.2 8 8 23 9.8 24 2 95.6 32 4 3 5 G /4 G /8 N/** 5.4.5.4 to amend, without notice, the specifications given in this document. 7/

General dimensions solenoids M4 M5 29 36 29,5 65 2 5 72 2 22 3 29,5 Ø9 Ø9 M6 36 3 29,5 5 68 Ø9 Circuit diagrams SB SB4 SB7 SB8 SB3 7/ to amend, without notice, the specifications given in this document. N/** 5.4.5.5

NAMUR interface 32 M5 thread 8 mm deep 2 8 24 Coding stud threaded M5x DIN 93-45 H M5 2 G /4 DIN/ISO 228/ Accessories Description Type Application Weight Ref. (kg) Data Sheet Flange plate 559857 Direct attachment to pneumatic linear actuators with NAMUR ribbing and for wall mounting,,5 752242 depending on the tubing position Yoke 54593 In conjunction with a flange plate for attachment to pneumatic linear actuators with NAMUR pillar (round), Adaptor plate 559853 Direct attachment to pneumatic rotary actuators with interface corresponding to former type valves,8 Silencer 45 Pressure connection G /8. Max. back pressure 6 bar, 758 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/** 5.4.5.6 to amend, without notice, the specifications given in this document. 7/

7/ N/** 5.4.5.7 to amend, without notice, the specifications given in this document.

N/** 5.4.5.8 7/ to amend, without notice, the specifications given in this document.