GUIDE 212.V3 VSD VERTICALLY INSTALLATION GUIDE. The Protector TM. Light Curtain Series 4694

Similar documents
CARE-C Light Curtain Installation Instructions.

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

Thru-Beam Photo Eye Monitored / Non-Monitored Battery Powered Emitter

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

Sliding Gate Operator User's Manual

INSTALLATION SHEET MODEL 618 SHEET NO ISSUE 2. The 618 can be mounted on the car doors using the standard fixing kit provided (Fig 1).

Sliding Gate Operator User's Manual

Electric Vehicle Charging Station

CX-SERIES ADVANCED BATTERY CHARGER

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Roll Up Door Operator

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Operators Guide: RoboSign Stop/Go Traffic Control System

OPERATION MANUAL Common for All models Bobbin Sensor (Weft End Detection) DP150 - L2 BP150 - L2-12V BP150 - L2-24V (PNP/NPN)

ZB0050 / ZB0051 ZB0070 / ZB0071

OPERATING INSTRUCTION

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Operators Guide: RoboSign Stop/Go Traffic Control System

Gate & Door Controller with LCD and Intelligent Technology

GUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations

INSTALLATION GUIDE AND USER MANUAL

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains

Tina 4A Connection block

FMC-1/2 Tina Muting unit

IGLOO IGLOO EASY INSTRUCTION MANUAL

Tina 10A/B/C Adaptor unit

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Photoelectric Sensors 55 Series

MKey9-series Safety Interlock Switch with Guard Locking

Sectional and Tilting Door Opener

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

OPERATING INSTRUCTION

DIAMOND POINT VIBRATING PROBES

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

OPERATING INSTRUCTION

The Navigator Elevator Landing System. Installation Manual. System Components: Selector Operation. Digital Connection

Photoelectric. Sensors Invisible Light Beam Protection Area

CD3000S-1PH Thyristor Unit Heater Break version

RVS-AX Instruction Manual

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

INTECH Micro 2300-RTD6

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

User Manual. Solar Charge Controller 3KW

GV Standard Three Wall Box Operation and Maintenance Manual

HL (AZH) LIMIT SWITCHES

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

1.Safe testing IMPORTANT:

Installation Instructions

CAUTION CM-SE CM-S21 CM-S41

SKC400U SLIDING GATE OPENER OWNER S MANUAL

LED Downlight Ceiling Fixtures

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

SA1W: Water Detection Sensors

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

ESD5550 / 5570 Series Speed Control Units

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

INDUS rail /

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Long-Range Barrier Sensors

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Automatic concealed bollards 275 H600 and 275 H800 Control station

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

LASER ENHANCED SEMI-AUTOMATIC GRIP OWNER S MANUAL RED LASER GREEN LASER

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Technical Manual Electrical Power Supply System T4002

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Electric Actuator Instructions

Checker Unload Checkstand Installation Instructions

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

User Manual Solar Charge Controller 3KW

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

QUADSCAN User s Guide Door Mounted Presence sensor

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Electronic Circuit Breaker ESS20-0..

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

Smile 41 Push-button box with/without emergency stop

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

CVR-625. Compact Vibrating Rod Instruction Manual

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

User s Manual. Automatic Switch-Mode Battery Charger

CHECKLIST & COMPONENTS

IMPORTANT SAFETY RECOMMENDATIONS

HS5E Miniature Interlock Switches with Solenoid

i3000s/i2000 Flex AC Current Probe

Transcription:

T 1 800 787 5020 F 1 905 846 2161 www.peelledoor.com GUIDE The Protector TM Safety Light Curtain Light Curtain Series 4694 VSD VERTICALLY SLIDING DOORS 11/24/2011

IMPORTANT INFORMATION FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS, INJURY, OR CALL BACKS. KEEP INSTRUCTION MANUAL ON SITE. FOR THE OPERATION OF LIGHT CURTAIN IN THE MODE AUTO BLANKING, THE FOLLOWING POINTS MUST BE OBSERVED: THE LIGHT CURTAIN REMAINS INACTIVE UP UNTIL THE GATE IS COMPLETELY OPEN. RUNNING MOVEMENTS BELOW THE ENTIRE OPENING ARE NOT MONITORED. DO NOT USE THIS PRODUCT IN EXPLOSIVE ATMOSPHERES, RADIOACTIVE ENVIRONMENTS OR FOR MEDICAL APPLICATIONS! USE ONLY SPECIFIC AND APPROVED DEVICES FOR SUCH APPLICATIONS OTHERWISE SERIOUS INJURY OR DAMAGE TO PROPERTY MAY OCCUR! IT IS IN THE SOLE RESPONSIBILITY OF THE PLANNER AND/OR INSTALLER AND/OR BUYER THAT THIS PRODUCT IS USED ACCORDING TO ALL APPLICABLE CODES AND STANDARDS IN ORDER TO ENSURE SAFE OPERATION OF THE WHOLE APPLICATION. ANY CHANGE OF THE DEVICE BY THE BUYER OR USER MAY RESULT IN AN UNSAFE CONDITION. THE MANUFACTURE DENIES EVERY LIABILITY AS WELL AS WARRANTY CLAIMS WHICH RESULT FROM SUCH MANIPULATION. OBJECTS THAT PASS THROUGH THE PROTECTED AREA FASTER THAN THE MAXIMUM RESPONSE TIME OF THE DEVICE MAY NOT BE DETECTED. IT IS THE RESPONSIBILITY OF THE SPECIFIER, PURCHASER AND INSTALLER TO ENSURE THAT ON COMPLETION, THE INSTALLATION COMPLIES WITH ALL RELEVANT FEDERAL, STATE AND LOCAL CODES AND REGULATIONS THAT APPLY TO YOUR APPLICATION. PARTICULAR ATTENTION SHOULD BE GIVEN TO CLAUSE 2.13.3.4 POWER CLOSING OF VERTICALLY SLIDING HOISTWAY DOORS AND VERTICALLY SLIDING CAR DOORS OR GATES OUTLINED IN ASME A17.1a-2008 / CSA B44a-08 ADDENDA TO SAFETY CODE FOR ELEVATORS AND ESCALATORS. THESE LIGHT CURTAIN SYSTEMS MUST BE INSTALLED ONLY BY AUTHORIZED AND FULLY TRAINED PERSONNEL. CAUTION! THE LIGHT CURTAIN IS DESIGNED TO DETECT PASSENGERS AND FREIGHT OF A SPECIFIC SIZE OBJECTS SMALLER THAN THE SPACING BETWEEN THE LIGHT BEAMS MAY NOT BE DETECTED. TRANSPARENT OBJECTS MAY NOT BE DETECTED. GATE LIGHT CURTAIN SENSORS AVOID IMPROPER USE

Table of Contents Parts Included 1 Assembly Notes 2 Installation Prep Work 3 New Rail Clips 4 Beam Blocker 5 Wiring 6 How it Works 7 Specifications 10

Parts Included 4694 Light Curtain Quantity 1 set 060004 Self Tapping Bolt 3/8-16 x 1 1/4 Quantity 2 066995 L/R Beam Blockers Quantity 1 pair Truss Head Screw 10-24 x 1/4 Quantity 30 066937 Z Clip Hex Head Bolt 5/16-18 x 7/8 Quantity 4 Flat Head Screw Undercut 3/8-16 x 1/2 Carriage Bolt 3/8-16 x 1 3/4 Washer 5/16 Quantity 4 066998 Mounting Angle Spacer 066932 Mounting Angle Lock Washer 5/16 Quantity 4 066001 Lock in Angle Lock Washer #10 Quantity 30 Lock Washer 3/8 Hex Nut, 3/8-16 Washer, 3/8 1

Position The cable outlets of the sensor edges must be at the top, as the car door must enter the protective area from the top. Assembly section. the top, as the gate/door must enter the protective area from the top. Assembly Notes Assembly Notes The cable outlets of the sensor edges must be at the top, as the gate/door must enter the protective area from the top. IP65 1. Fasten the sensor edges with 3 screws to a flat wall or inside the guide tracks. The lenses of the sensor edges (black points) must face each other. 2. Mount the control unit with 2 or 4 screws to a stable location near the emitter edge. Please note that the cable length of the emitter (white markings) is 5 m IP65 only, whereas the cable of the receiver (blue markings) E has a length of 15 m. 3. Connect the cables from the sensor edges to the control unit. Guide and fix them properly and Alignment The separate them, as far as possible, from cables The sensor sensor edges have must to be aligned not within be bent 10 degrees or be exposed that carry high voltages and/or high currents in of each to other. tension. order to minimize possible EMI interferences. 4. Connect the control unit to the gate/door drive unit (Relay Output, Test Input). 5. Connect the protective Eground terminal of the control unit with a low impedance cable of AWG 15 / 1.5 mm2 or thicker and a maximum length The sensor edges have to be aligned better than of 200 mm to a protective grounded frame or a ± 10. Cleaning of the sensor edges protective ground socket. The edges shall be cleaned with a soft tissue and little 6. soapy Connect water power only. Any to use the of abrasive control or unit. inappropriate The device cleaning indicates solvents that may it is cause receiving loss of power range or by may switchingon the the green device. LED (power). When all light beams damage are free and the test input is on high, the output relay changes to the state OK (relay output NO) and the yellow LED goes out. Environment The sensor edges must not be bent or exposed to tension. The cables shall not be stretched or squeezed. Ensure the cable radius is not less then 80 mm (3 in) Avoid contamination by oil or greasy liquids. The sensor edges must not be bent or be exposed to tension. IP65 Keep the optical edges free and clear of dust and dirt on the lenses. Ensure there is no direct light sources interfering with the light curtain receiver. i.e. sunlight, flashlight, strobe light. If this happens, switch the location of the emitter and receiver. The sensor edges have to be aligned better than ± 10. IP65 R R R The cables shall not be stretched or squeezed. Ensure a cable radius R > 80 mm and avoid contamination by oil or greasy liquids. R If there are different LED readings than stated in paragraph 6, please go to the trouble-shooting The section. cables shall not be stretched or squeezed. Ensure a cable radius R > 80 mm and avoid contamination Assembly Notes by oil or greasy liquids. The cable outlets of the sensor edges must be at the top, as the gate/door must enter the protective area from the top. R IP65 IP65 2 Please note that the Peelle Protector is an optical device. Therefore, avoid dust and dirt on the lenses. Other infrared light sources like optoelectronic sensors, flashlights, direct sun light, etc. shall not shine directly into the receiver edge. They can interfere with the Peelle Protector and may lead to instable function. In such a case, please swap the emitter and the receiver edge, as the emitter edge is not sensitive to optical disturbance. Danger of Fix high the voltage! control unit with 2 or 4 screws in order to Disconnect avoid power vibration. before opening the cover of the Close control the unit! cover of the control unit in order to avoid dust, dirt, humidity, and liquids on the electronic circuits and to avoid electrical hazards.

Installation Prep Work 3

New Rail Clips Alternate Mouting 2011 - Present 4

Beam Blocker 5

Wiring WIRING FOR EXISTING PEELLE GATES WITH SENSOR BEAM When adding a light curtain to an existing gate, compliance with A17.1-2000 is required. If the pre-existing reversal device is a Peelle Sensor Beam, simply wire the Output Relay Contact between 32 and 170 of the Peelle Controller. WIRING FOR EXISTING PEELLE GATES WITH OR WITHOUT REVERSING EDGE 1. Wire the Output Relay Contact to the GR relay of the door control. Add Contacts from Fire Service relays (not included) to ignore detection during Fire Service. 2. Wire a gate Slow Speed Relay as shown in the diagram to ensure gate Slow Speed operation during Fire Service Phase 1 Recall. 3. Wire the gate Slow Speed Relay Contacts to the GH / GL contactor of the existing logic as shown. STEP 1 Output Relay Contact STEP 2 Slow Speed Relay STEP 3 Slow Speed Relay Contacts NOTES AND EXCEPTIONS: 1. Code compliance is the responsibility of the installer. 2. For other control interfaces, please contact Peelle engineering for assistance. 6

How it Works The PROTECTOR is an infrared light curtain sensor system for detecting obstructions immediately under a vertically descending freight car door or gate. The system contains 24 protective beams spaced evenly (see specifications). The standard product is suitable for vertically closing freight doors of up to 20ft. (6m) wide. The system ignores the closing freight car gate as it closes over the system sensors. The system will ignore the freight car gate provided that the closing speed of the door is greater that 0.2ft/s and less than 7ft/s. The system consists of three parts - a Transmitter Edge (Tx), Receiver Edge (Rx) and a Light Curtain Controller. The edges contain all the intelligence required to control and synchronize the transmission and reception of all the protection beams and provide an output that indicates the obstruction status of the detector system to the Light Curtain Controller. The RX edge includes a special routine which allows for any one beam to be permanently obstructed but which allows the system to remain operational. This override condition can be identified by monitoring the red LED on the RX edge. No Override Condition - LED instantly illuminates on detection. Override Condition - LED flashes momentarily, and then remains constant on detection. If two or more beams are permanently obstructed then the system will remain in a permanent detect state. The Light Curtain Controller uses dual pole changeover relays which are wired to the door controller to cause a door reversal when the system enters a detection state. This universal method of connection is detailed in the section Installation - Light Curtain Controller. Installation TX and RX (light curtain arrays) 7

How it Works Installation - Light Curtain Controller (Fig. 2) The Light Curtain Controller box can be mounted to the top of the elevator car by means of the mounting holes and screws. After ensuring the supply switch is off, connect the electrical supply and relay output contacts to the elevator system according to local code requirements. Ensure the correct supply voltage is selected (115V or 230V) BEFORE switching on the supply. Switch on the supply, check that both red and green LEDs are on. Connect the transmitter (Tx) and receiver (Rx) arrays to the Light Curtain Controller. With the light curtain uninterrupted, the red LED should be off and the relay should be energized. With the beams interrupted, the red LED should illuminate and the relay should drop out. Supply Requirements Voltage - 230V or 115V AC, Frequency - 50 or 60Hz. Power consumption - less than 14VA Output Contacts Dual pole changeover, Relay rating (each contact) 240V AC 4A RES. Field Wiring Cable insulation to be rated 60 C minimum Copper conductors must be used. Nominal tightening torque vale 0.45Nm Cord Routing Connect the cable assembly to the short flying lead from the Tx and Rx arrays and plug it into the Light Curtain Controller. It is important that the cord is routed with sufficient free cord to avoid sharp bends or flexing at anchor points. Ensure there is no risk of catching or rubbing by fastening the cord (using the nylon clamps and restraints provided in the parts kit). Generous bend radii should be maintained, to avoid damage to the cord. Ensure cable is clamped either side of the inline connector to restrain the short flying lead from the array. This cord is stationary unlike typical passenger applications. Switch Selection The receiver array contains a 2 way switch. Switch configuration is as follows: Selector 1 (ON) = Buzzer On after time-out Selector 1 (OFF) = No Buzzer after time-out Selector 2 (ON) = Buzzer On with detection Selector 2 (OFF) = No Buzzer with detection Selector 3 (ON) = Detect Relay - resets after time-out Selector 3 (OFF) = Detect Relay - remains set after time-out If you are experiencing false door reversals, Switch 2 can be set to the off position in an attempt to resolve the false door reversals. Switches can be revealed by carefully prying off the filter. The switch is located near the green LED. Indicator LEDs Both the transmitter and receiver have a green LED to indicate that power is present. In addition, the receiver has a red LED to indicate that the sensor system has detected an obstruction. DIP Switches Inside Receiver (Rx) There are two dip switches inside the receiver. They are located at the top of the receiver (Rx) behind the plastic cover. Dip switch 1 has no current function. Dip switch 2 controls the sensitivity of the receiver (Rx). It should be field set to the OFF position for applications less than 8-0 in opening width. 8 210.V8 QUICK REFERENCE

Specifications Item Detail Additional comments Number of beams 24 non-focused beams Infra-red Number of Sensors 24 See drawing outline Sensor Spacing 2.95 (75mm) See drawing outline Scan Type Door Closure Speed Range Direct 0.2 ft/s 7.0 ft/s Minimum Maximum Range of detection 4m Standard Light Immunity 50 000 lux Visible light Angular displacement Positional mounting tolerance 10 o +/- 0.7 (18mm) vertically +/- 0.2 (5mm) side by side Operating voltage 24 volts 16 volts min 30 volts max Current consumption <100 ma RMS Total of both units Control unit FPS 0272 Mandatory Environmental protection IP54 Conformal coating to PCB's Operating temperature range Storage temperature range Unit size 0 C to +70 C -40 C to +80 C 1.18 x0.8 x7 (30x20x2136mm) Mounting Five screw positions See drawing outline Indicators Cable supplied Supply present: System fault / beams obstructed: Two x 26 (8m) approx of 3 core cable Green LED Red LED Connects to product via short fixed lead Case material Aluminium alloy Finished Black Cover (filter) Infra-red transparent plastic Snap-on fixing Installation kit Instructions - 1 off Cable Clips - 10 off Nytie - 6 off Screws M4 x 20mm - 20 off M4 Hex Nut - 10 off Washers - 10 off Self Tapping SYSTEM APPROVALS UL, cul, CE (EMC) EN12015, EN12016. 9

Specifications 405mm 300mm 600mm 600mm 154mm 15 INFRA-RED TRANSPARENT PLASTIC FILTER 19 MOUNTING HOLE CENTER LINE 30 HOUSING. BLACK ANODISED ALUMINIUM ALLOY 10

Specifications FPS 0272 INTERFACE UNIT Item Detail Additional comments INTERFACE UNIT ENHANCED FEATURES Buzzer with adjustable time-out Power Consumption FPS 0272 INTERFACE UNIT N/O Item Detail TIME OUT Additional EARTH comments COM 1 2 3 RELAY /GRD N/C Buzzer with adjustable time-out INTERFACE UNIT ENHANCED FEATURES Power Consumption COMMON FEATURES: N/O COM N/C N/O COM N/C Operating Temperature Range COMMON FEATURES: Storage Temperature Range 4.0VA (Typical) 4.0VA (Typical) TO THE CONTROLLER (VOLTAGE FREE CHANGE OVER CONTACTS) RELAY LED (RED)- + O/P C POWER LED (GRN)- DETECT RELAY TRANSFORMER TIME OUT Voltage free change-over 1 2 3 relay RELAY + O/P C VOLTAGE SELECTION 115/ 230V SUPPLY EARTH /GRD Supply Voltage 230 or 115V AC (50Hz or 60Hz) Switch selected (SW1) Signal Output Fail Safe Conditions N/O COM N/C DETECT RELAY TO THE CONTROLLER (VOLTAGE FREE CHANGE OVER CONTACTS) contacts Faulty cable or supply failure 0 o C to +70 o C RELAY LED (RED)- + O/P -40 o C to +80 o C C POWER LED (GRN)- + O/P C LIGHT CURTAIN TRANSFORMER VOLTAGE SELECTION 1=BUZZER ON TIMEOUT 2=BUZZER ON DETECTOR 3=DETECTION RELAY OPTION 115/ 230V SUPPLY 1=BUZZER ON TIMEOUT 2=BUZZER ON DETECTOR LIGHT CURTAIN 3=DETECTION RELAY OPTION SUPPLY UNIT Contacts rated / set, 240V AC 4A RES SUPPLY UNIT PRODUCT SPECIFICATION PRODUCT SPECIFICATION Unit size 2 x 2 x 12 (54 x 54 x 300mm) See drawing outline Supply Voltage 230 or 115V AC (50Hz or 60Hz) Switch selected (SW1) Mounting Four screw positions (2 sets) See drawing outline Voltage free change-over relay Signal Output Contacts rated / set, 240V AC 4A RES Enclosure material Plated contacts steel Fail Safe Conditions Supply Faulty cable present: or supply failure Green LED Indicators System fault / System Detection: Red LED Operating Temperature Range 0 o C to +70 o C SYSTEM APPROVALS Storage Temperature Range UL, cul, CE (EMC) -40 o C to +80 o C EN12015, EN12016 Unit size 2 x 2 x 12 (54 x 54 x 300mm) See drawing outline Mounting Four screw positions (2 sets) See drawing outline Enclosure material Indicators Plated steel Supply present: System fault / System Detection: Green LED Red LED SYSTEM APPROVALS UL, cul, CE (EMC) EN12015, EN12016 11

T 1 800 787 5020 F 1 905 846 2161 www.peelledoor.com TECHNICAL SUPPORT 1-800-787-5020 ext 275 NORTH AMERICAN SALES sales@peelledoor.com EXPORT SALES exportsales@peelledoor.com