SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL

Similar documents
SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

GENERAL PURPOSE MIXERS

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Corrosion Coupon Rack Operations & Maintenance Manual

Centrifugal Separator Operations & Maintenance Manual

Separator Systems Operations & Maintenance Manual

Bypass / Filter Feeders Operations & Maintenance Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Modular Outdoor Fountain System

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Fluid Coil Installation, Operation and Maintenance

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

25 GALLON PORTABLE OIL LIFT

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

HA/HAB Fiberglass Wall Mount Ventilators

OWNERS MANUAL JANUARY 2007 ISO

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

advanced FLOW engineering Instruction Manual P/N: , & WL

Air Curtain. Installation, Operating and Maintenance Instructions

PowerFLO 5800/5900 Series

Manual. Economy Glycol Feeder. Installation Maintenance Repair Manual

MODEL TON HYDRAULIC FLOOR JACK

MODEL TON HYDRAULIC FLOOR JACK

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Injection/Sample Quills

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Wastewater Air Release Valve Models 48A, 49A

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

advanced FLOW engineering Instruction Manual P/N: &

BCFS Belt Driven Centrifugal Filtered Supply Fans

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

Water treatment services product catalog

advanced FLOW engineering Instruction Manual P/N: S Make: Dodge Model: Challenger Year: Engine: V6-3.6L / V8-5.7L / V8-6.

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Val-Matic Extended Bonnet Assembly Instructions

Benron Equipment & supply, Inc.

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

JET METER INSTRUCTIONS

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Rotary Cutter Drives Service Manual

ARAG Modular Manual Valve Operating Instructions and Parts Manual

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

FOR TECHNICAL ASSISTANCE

EMERGENCY EYE/FACE WASH

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Operating Instructions & Parts Manual. Truck Drain. Model 48UJ80 and 48UJ81

ADI-125/750 ADI-125/1500 ADI-125/2500

Model 8309WC Barrier Free Shower & Eye/Face Wash

Model C230 Pump Controller

Industrial Gly-Pack Feed Systems Operations & Maintenance Manual

MODEL: ATVBK-710 BEFORE RETURNING THIS PRODUCT FOR ANY REASON, PLEASE CALL

Model 8309WC Barrier Free Shower & Eye/Face Wash

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

INSTRUCTION MANUAL # FiTech Hy-Fuel Tight-Fit In-Tank Retrofit Kit

Owner's Manual. Model: ATVBK-710 ( ) (7-Nozzle Deluxe Boom Assembly w/connecting Fittings) Technical Specifications.

Val-Matic 4-20 Air/Vacuum Valve

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

advanced FLOW engineering Instruction Manual P/N: / Make: BMW Model: 328d/dx (F30/F31) Year: Engine: L4-2.

INSTALLATION and OPERATION INSTRUCTIONS

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

½"-3" Air/Vacuum Valve Models 100S to 103S

advanced FLOW engineering Instruction Manual P/N: / /

TECHNICAL INFORMATION

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

ARAG Modular Electric Valve Operating Instructions and Parts Manual

1600 PSI ELECTRIC PRESSURE WASHER

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

LIGHTNING PROTECTION UNIT (LPU)

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Surface Mounted Bottle Fillers

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

Techcon Systems TS5322 TS5322D Adjustable Mini Spool Valve. User Guide

MRC 150/300 USER MANUAL. 1 Laird Technologies

Tuffy Liquid Level Controls with Pneumatic Switch

EF SERIES MOTORS OPERATION & PARTS MANUAL

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Universal Bevel Drives Service Manual

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

MV Series Motors Operation & Parts Manual

DOUBLE DRUM OPERATIONS MANUAL 2017 VERSION C

Condensate Pump. Installation and Safety Instructions CP-22 CP CP-22LP CP-22LP-230

advanced FLOW engineering Instruction Manual P/N: / Make: RAM Model:1500 EcoDiesel Year: Engine: V6-3.

advanced FLOW engineering Instruction Manual P/N: &

Transcription:

SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL PLEASE RECORD THE FOLLOWING DATA (Information is located on the product label or packing slip) Product: Model No: Serial No: Installation Date: Installation Location / Application: The above information will help when ordering replacement parts and accessories for your Wingert Sample Cooler or Sludge Trap. J.L. WINGERT CO. MANUFACTURED PRODUCTS Mixers, Bypass Feeders, Filter Feeders, Bromine Feeders, Sample Coolers, Sludge Traps, Separators, Separator Systems, Tank Stands, Tank Package Systems, Glycol Feed Systems, Coupon Racks, Control Stations, NEMA Enclosures, Custom Packaged Systems and Specialty Welding P.O. Box 6207 Garden Grove, CA 92846-6207 / 11800 Monarch St. Garden Grove, CA 92841-2113 Phone (714) 379-5519 Fax (714) 379-5549 Northern California Region Phone (510) 487-5310 Southwest Region Phone (602) 470-1015 Email: customerservice@jlwingert.com www.jlwingert.com OM0400.A 03/12

CONTENTS: 1.0 INTRODUCTION 2 2.0 WARRANTY 2 3.0 UNPACKING 2 4.0 MODEL NUMBER VERIFICATION 3 5.0 LOCATION AND ENVIRONMENT 4 6.0 SAFETY 4 6.1 SAFETY HIGHLIGHTS 4 7.0 INSTALLATION 5 7.1 PLUMBING 5 8.0 MAINTENANCE 6 9.0 TEMPERATURE AND PRESSURE LIMITS 6 10.0 NOTES 6 PAGE 1.0 INTRODUCTION Thank you for your purchase of a J.L Wingert Sample Cooler or Sludge Trap. Wingert Sample Coolers are an effective way to reduce the temperature of a fluid for testing it s quality. Wingert Sludge Traps allow for cleaning of the sample fluid of debris before it enters the Sampler Cooler, thus preventing the coils from clogging; increasing the life of the Sample Cooler. 2.0 WARRANTY Wingert Sample Coolers and Sludge Traps are warranted against manufacturing defects in material and workmanship for one year from the date of shipment. Applications outside the service for which the product is designed, including any non-factory modifications, will automatically void any warranty. Items returned to J.L. Wingert Co. for warranty consideration must be transported via prepaid freight. Final warranty determination will be made upon inspection. J.L. Wingert Co. will, at their discretion, repair or replace any defective item. Any repair or replacement outside warranted limitations will be considered a repair order and quoted accordingly. All replacements will be F.O.B. factory. There are no other implied or expressed warranties. 3.0 UNPACKING Wingert Sample Coolers and Sludge Traps are fully assembled and ready for installation. A Sample Cooler or Sludge Trap will be packed in a carton for shipping. Inspect packaging upon receipt for any damage. Unpack and inspect the product for damage and verify that goods received correlate with the packing list and product table on page 3. Verify that no packing material has obstructed the inlet, outlet or purge openings. Notify the factory of any discrepancies immediately upon receipt. If any product is damaged due to freight handling, contact the factory immediately for further assistance. It is recommended that photo documentation of any damage or discrepancy be supplied to support any claims. NOTE: Most freight carriers allow only a limited time after receipt of goods to file a freight claim. Page 2

4.0 MODEL NUMBER VERIFICATION SC - 1 - B - 316 / MB /MB OPTIONS MOUNTING BRACKET COIL MATERIAL 316 316 STAINLESS STEEL 600 ALLOY 600 COP COPPER A B END CONNECTIONS ¼" OD TUBING PLAIN ¼" FNPT COIL TYPE 1 FIXED COIL 2 REMOVABLE COIL SC BASE MODEL SAMPLE COOLER ST / MB /MB OPTIONS MOUNTING BRACKET ST BASE MODEL SLUDGE TRAP Page 3

5.0 LOCATION AND ENVIRONMENT The Wingert Sample Coolers and Sludge Traps requires periodic inspection. Sample Coolers and Sludge Traps should be accessible from all directions for inspection. Removable coil will require special clearances. 6.0 SAFETY J.L. Wingert s equipment is designed and built with safety in mind. However, proper installation and operation can increase your overall safety. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS. 6.1 SAFETY HIGHLIGHTS Read and understand the following safety highlights. PRESSURE INSIDE THE UNIT See design specification for maximum operating pressure. Do not perform maintenance or repair without first releasing pressure and draining the fluid from the unit. EQUIPMENT IDENTIFICATION LABEL Identification label provides equipment information. Be sure the coil material and pressure ratings are as specified on the Equipment Identification Label and conform with your requirements. Page 4

7.0 INSTALLATION 7.1 PLUMBING Check local codes prior to final location and mounting. It is recommended to install a J.L. Wingert Sludge Trap inline before the J.L. Wingert Sample Cooler. This will help keep the Sample Cooler coils clean of debris. Below is a recommended piping diagram for installing the Sludge Trap and Sample Cooler. J.L. Wingert does not recommend installing a valve on the Cooling Water Discharge. If a valve is installed on the Cooling Water Discharge and is not open, an unwanted increase in pressure can occur inside the shell resulting in damage to the Sample Cooler. Sample Fluid Inlet 1/4" FNPT Sample Fluid Discharge 1/4" OD Tube or 1/4" FNPT Sample Cooler Sludge Trap Cooling Water Inlet 1/2" FNPT Cooling Water Discharge 1/2" FNPT Sludge Trap Drain 1/2" FNPT Page 5

8.0 MAINTENANCE Purging of the solids is the only maintenance that a Wingert Sludge trap requires. Periodic inspection through inlet and outlet ports is recommended. If a Sample Cooler with a removable coil is purchased, periodic removal and inspection of the coil and inside of the shell is recommended. 9.0 PRESSURE AND TEMPERATURE LIMITS MATERIAL SAMPLE COOLER OPERATING CONDITIONS PRESSURE COIL TEMPERATURE 316SS 1500 PSI (103.4 bar) 600 F (315.5 C) ALLOY 600 1500 PSI (103.4 bar) 600 F (315.5 C) COPPER 300 PSI (20.6 bar) 400 F (204.4 C) CARBON STEEL SHELL 200 PSI (13.7 bar) 250 F (121.1 C) SLUDGE TRAP OPERATING CONDITIONS MATERIAL CARBON STEEL PRESSURE TEMPERATURE 1500 PSI (103.4 bar) 600 F (315.5 C) 10.0 NOTES Page 6