PVL Series. Solenoid & Remote Pilot Operated 1/8" & 1/4" Valves. Section C. C59

Similar documents
PVL Series Solenoid & Remote Pilot Operated 1/8" & 1/4" Valves zpv06

ADEX Series. Air Control Valves. Section D

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8" Port zpv02 A B C D E F G H. Section H

Isys Micro Series. Air Control Valves. Section E

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic

503 Series Solenoid Pilot Actuated Valves

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

Features General Information ompact, easy to install, reliable, serial bus compatible... Easy to meet system design needs Full flow capacity allows di

Isys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration

atalog /US asic eatures llen ey Sensor Locking lip ircuit ressure /12 5/32" Tube Instant onnections Driving ressure U xhaust ack ressure Thresho

Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products.

Valve Products. B Series Valve

Single Solenoid External Pilot Normally Closed

Viking Lite Series Valves Air Control Valves

Poppet Series Compressed Air & Vacuum

DX ISOMAX Series Directional Control Valves &

Valve Products. Viking Lite Series Valves. Operating information. Minimum operating pressure, PSIG (bar) Materials. Recommended air quality for valves

Solenoid Pilot Actuated Valves

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Instrument Ball Valves

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2

ISOM Features Features eramic Technology ll ISOM products use high-tech ceramic switching technology providing: xcellent Reliability Long life in exce

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

Mechanical Style Pressure Switch. Specifications

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

4 Port Solenoid Valve

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

3/2 ^ % Features. Construction. Electrical

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

Couplings - Quick Disconnect

4 Port Solenoid Valve

V Series Manifold Valves with Collective Wiring Size 1. V Series Size 1 Pneumatic Connectors. Moduflex Valve System V Series Manifold Valves Size 1

Valve Products Viking Lite Valves

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

atalog /US Index Vacuum ups Product Selection Technical Lifting orces, up iameters, Material Specifications 6-9 P lat Precision molded single li

Your Global Source for Today s Most Popular Solenoid Valves

B Series Air Control Valves B3.75 Cv 1/8", 1/4" Port B Cv 1/4", 3/8" Port B Cv 3/8" Port B Cv 1/2" Port B8 7.

NAAMS Standards Compliant Power Clamp Cylinder ø50, ø63

Valvair II. Solenoid Operated Directional Spool Valves. Section E.

Adams. Progressive. Description. Typical system layout using Pneumatic Pump for grease - with monitoring. Typical system

F20 & F21 QIX Particulate & Coalescing Filters

ROSS CONTROLS. Double Valves for Control Reliable Energy Isolation.

VALVES. V44/V45 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 26 mm

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

SRB Series. UL Recognized CSA Certified VDE Approved* Specifications. SRB Series. Power Inlet Filters & Power Entry Modules

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in.

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

VAL /2, 5/2, 5/3, and 2 x 3/2 Directional control valves. 3-Port and 5-Port Air Pilot Valves

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

Low Voltage Fuses AFaC and BaC types

SMART PUMP VACUUM MANAGEMENT SYSTEM SETUP AND INSTALLATION GUIDE

Corcom Product Guide. Introduction. Catalog: Issue Date:

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

Vacuum Cups. Styles. Cup material Nitrile Silicon Urethane Material code NBR SI U Operating temperature ( C) -60 to ±5 55 ±5 55 ±5

G780, 3-Way, Mixing Flanged Globe Valve

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

General Specifications

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Sliding Seal & Brass Poppet Valves

Flow Controls & Accessories

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

PVL-B2. Stackable and Stand-alone Inline Valves. PVL-B21 - Stand-alone Series. PVL-B22 - Stackable Series. PVL-B2 Valve Series

Transportation. Air Brake Tubing

MK Series High Performance Butterfly Submittal/Technical Data

5.2 to 79 gpm 3000, 3600, 5000 psi

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

^ % 3/2 5/2 SERIES 362/562. Features. Construction. Nominal Ambient Temp. Ranges. Electrical

Assembly kits (501 Series/502 Series/503 Series) 25 Pin Sub-D Connector Kit

Flow Controls & Accessories

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

Watertight Wiring Devices

Pneumatics Pneumatic Quick ouplings Single Shut-Off ouplings Single Shut-Off couplings are primarily used for pneumatic applications, connecting air t

General Specifications

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

How to Order. Nil M. Action S T. Load voltage Wiring. M9NV 5 V, 12 V 3-wire (PNP) M9PV 12 V. F9NWV 5 V, 12 V 3-wire (PNP) F9PWV

Selection Information Molded Case Circuit Breakers

Bussmann series IEC cylindrical fuses

Quick Couplings. Section F

Pin & Sleeve. Heavy Duty Industrial Wiring Devices for North American and European Markets

Pneumatic Division North America Richland, MI 49083

High Performance Butterfly Valves 2 Way Way 2-20 Bray MK Series High Performance Butterfly Valves ANSI Class 150 and 300

NEMA Contactors & Starters A200

April 2007 / BULLETIN Solenoid Valves. The right solenoid valve for any job.

SUB-BASES and MANIFOLDS for ISO 5599/I VALVES

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Flow Controls & Accessories

Dimensions / Technical Data / Order Codes

5.2 to 79 gpm 3000, 3600, 5000 psi

411BAM Battery Auctioneering Module

Spool & Sleeve Valves for ANSI Sub-Bases Series W70

Control Reliable Monitored Valves

Transcription:

Series Solenoid & Remote Pilot Operated /8" & /4" Valves Section Moduflex www.parker.com/pneu/pvl asic Valve unctions...60 Stacking pplications...6-62 eatures ( & )...63 ommon Part Numbers-Stacking ( & )...64 ccessories ( & )...65 ommon Part Numbers-Inline ( & )...66 Solenoids, lectrical onnectors...67-68 eatures (0 & 0)...69 Stacking System Overview (0 & 0)...70 lectrical onnection (0 & 0)...7 ommon Part Numbers (0 & 0)...72-73 Ordering Information Solenoids (0 & 0)...74 0...75-76 0...77-78 Pin ssignments (0 & 0)...79 Technical ata...80-8 ables...82-83 ccessories / Spare Parts...84-85 imensions...86-92 OL ITMS R MOST POPULR. 59 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- asic Valve unctions Single Solenoid 4-Way, 2-Position 4-Way Valve unctions Single Remote Pilot 4-Way, 2-Position #4 #2 #4 #2 Moduflex e-energized position Solenoid operator #4 de-energized. Pressure at inlet port connected to outlet port 2. Outlet port 4 connected to exhaust port 5. nergized position Solenoid operator #4 energized. Pressure at inlet port connected to outlet port 4. Outlet port 2 connected to exhaust port 3. ouble Solenoid 4-Way, 2-Position Normal position Pressure at inlet port connected to outlet port 2. Outlet port 4 connected to exhaust port 5. Operated position Maintained air signal at port 4. Pressure at inlet port connected to outlet port 4. Outlet port 2 connected to exhaust port 3. ouble Remote Pilot 4-Way, 2-Position #4 #2 #4 #2 Solenoid operator #4 energized last. Pressure at inlet port connected to outlet port 4. Outlet port 2 connected to exhaust port 3. Solenoid operator #2 energized last. Pressure at inlet port connected to outlet port 2. Outlet port 4 connected to exhaust port 5. Momentary air signal at port 4 last. Pressure at inlet port connected to outlet port 4. Outlet port 2 connected to exhaust port 3. Momentary air signal at port 2 last. Pressure at inlet port connected to outlet port 2. Outlet port 4 connected to exhaust port 5. ouble Solenoid 3-Position ouble Solenoid / Remote Pilot ual 3-Way, 2-Position N (NNP) P #4 #2 #4 #2 #4 #4 With #2 operator energized inlet port connected to cylinder port 2, cylinder port 4 connected to exhaust port 5. With #4 operator energized inlet port connected to cylinder port 4, cylinder port 2 connected to exhaust port 3. ll Ports locked ll ports blocked in the center position. enter xhaust ylinder ports 2 and 4 connected to exhaust ports 3 and 5 in center position. Port is blocked. With #4 & #2 operators both de-energized pressure at inlet port blocked, outlet port 4 connected to exhaust port 5, outlet port 2 connected to exhaust port 3. With #4 operator energized pressure at inlet port connected to outlet port 4, exhaust port 5 blocked, outlet port 2 connected to exhaust port 3. With #2 operator energized pressure at inlet port connected to outlet port 2, exhaust port 3 blocked, outlet port 4 connected to exhaust port 5. With #4 & #2 operators both energized pressure at inlet port connected to outlet ports 4 & 2, exhaust ports 3 & 5 blocked. 60 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stacking System Overview pplication The Series stacking system permits assembly of several valves into one manifold. Supply is connected at either a single or dual head / tail set.* Two common exhaust galleries are provided. onnections to outlet ports #2 and #4 on each valve can be accomplished by threaded pipe or instant tube fittings. lectrical connection is made to each solenoid utilizing a 5mm, 3-Pin connector plug ( & ). ach manifold assembly can handle any combination of the following valve types: Single Solenoid Single Remote Pilot ouble Solenoid ouble Remote Pilot Two valve sizes can be combined in one manifold using a transition kit. * or simultaneous operation of more than 5 valves, a dual head / tail set is recommended. Stacking pplications Manifold shows solenoid and remote pilot valves, threaded pipe ports, instant tube fittings, and a single supply head / tail set. Moduflex eatures reatly reduces installation costs. Reduces piping and the risk of leaks. onsolidates controls, saves space. Provides custom valving arrangements with standard components. Improves appearance of pneumatic equipment. ommon main supply port. llows for two common exhausts which can easily be plumbed away for cleanliness. Indicator lights and surge suppression available. esigned for 35mm IN rail mounting. May be surface mounted by removing IN rail clips. Servicing valves can be accomplished quickly without disassembling the entire manifold or removing plumbing. 6 Parker Hannifin orporation Pneumatic ivision

Moduflex atalog 0600P- Mounting Options Mounting on 35mm IN Rail Valve manifolds mount quickly and easily to 35mm IN rail with the use of a pneumatic head / tail set. The dual head / tail set provides input and exhaust ports at both ends and is recommended if more than 5 valves are to be operated simultaneously. Surface Mounting Manifolds may be surface mounted by removing the 35mm IN mounting hardware on the pneumatic head / tail set. Removal or Replacement Modules are removed in reverse of the order shown at right. efore removing a module for service or replacement, loosen the pneumatic tail piece. Stacking pplications Mounting Procedure. lip on and tighten the pneumatic head piece. 2. ssemble the two parallel mounting rods using cross rods provided with modules. module 3. lip on the pneumatic tail piece. Start screws into mounting rod but leave loose for module insertion. 4. To mount valves, position upper slot then pushlock lower slot. Mount modules (valves, modules, transition pieces, etc.) and press together. O-rings Manifold shows solenoid and remote pilot valves, threaded pipe ports, instant tube fittings, and a single supply head / tail set. 5. Tighten the assembly. 62 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- eatures & Series Series Specifications 4-Way, 5-Port, 2 or 3-Position Valves Single & ouble Solenoid Single & ouble Remote Pilot ual 3/2 -.6 v /8" NPT & SPP /4" & 6mm Tube Porting -.2 v /4" NPT & SPP 3/8" & 6mm Tube Porting Mounting Style Stacking Manifold Valve IN Rail Mounting (35mm) Moduflex Solenoid Pilot ctuation ontinuous uty Rated,.2W - 2V & 24V.6V - 24V, 20V, 240V 3-Pin, 5mm (/8"), (/4") Shown e-nergized Manual Overrides rass Locking & Non-Locking Operating Pressure 30 to 50 PSI (30 to 035 kpa) Operating Temperature 5 to 40 (-5 to 60 ) ertification / pproval pproved to be Marked UL (0 only) N 79 300 Note: units are polarity sensitive. Pressure xhaust 63 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- ommon Part Numbers Single Solenoid / Remote Pilot 4-Way, 2-Position (/8") & (/4") Stacking Valves ouble Solenoid / Remote Pilot 4-Way, 2-Position #4 #2 #4 #2 #4 #2 #4 #2 Moduflex Valve Only 268 2687 2606 26067 2697 26097 /8" SP /8" NPT 6mm Tube /4" Tube /4" NPT 3/8" Tube 0.6 v.2 v Valve Only 2268 22687 22606 226067 22697 226097 /8" SP /8" NPT 6mm Tube /4" Tube /4" NPT 3/8" Tube 0.6 v.2 v Locking Manual Override, Valve Less Solenoid. Non-Locking Manual Override, Valve Less Solenoid. ouble Solenoid / Remote Pilot 4-Way, 3-Position ouble Solenoid / Remote Pilot ual 3/2 Normally losed P P #4 #2 #4 #2 Valve Only 27687 /8" NPT 0.6 v 27697 /4" NPT.2 v #4 #4 Valve Only 25687 /8" NPT 0.6 v 256067 /4" Tube 25697 /4" NPT.2 v Non-Locking Manual Override, Valve Less Solenoid. #4 #2 #4 #2 Valve Only 28687 /8" NPT 0.6 v 28697 /4" NPT.2 v Non-Locking Manual Override, Valve Less Solenoid. Notes: Solenoids or Remote Pilot dapter must be ordered separately from page 67. ach valve is shipped with 2 tie rods for stacking assembly. OL OPTIONS R MOST POPULR. 64 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stack omponents & ccessories Single Supply Head / Tail Sets & Stacking System Transition Kits Series Model Number Port Size 797 /4" NPT 79 /4" SP 737 3/8" NPT ** 73 3/8" SP Kit includes: Ported (head) and lank (tail) plus all necessary hardware. * IN rail mounting clips on both head and tail. Maximum stack length of 6 valves. **! aution: IN rail mounting clips on head piece only. Maximum stack length of 8 valves. Note: IN rail mounting clips may be removed for surface mounting. ombination Model Number Port Size PVUL97 NPT & PVUL9 SP Kit enables valves of two different sizes to be combined in the same stack. Kit includes: 2 Ported Heads (one for each valve size) and a Transition Module with an uxiliary Supply Port. Maximum number of valves for each size is 6. Larger Size Head Transition Module Smaller Size Head Moduflex ual Supply Head / Tail Sets Pressure Isolation Kit ssembly Instructions Valves 3 5 3 5 3 5 xtended ross Rods Series Model Number Port Size 7297 /4" NPT 729 /4" SP 7237 3/8" NPT 723 3/8" SP Kit includes: 2 Ported s (head and tail) plus all hardware. Mounts to 35mm IN rail at both ends. Maximum stack length of 6 valves. Note: IN rail mounting clips may be removed for surface mounting. xample : Two different pressures P and P2 can supply the same bank of power valves, the exhausts remaining common. xample 2: omplete isolation of the commons in the same bank of power valves: main pressure and exhaust commons. xample 3: The exhaust commons can be isolated within the same bank of power valves, while the main pressure supply remains common. Series Model Number Kit includes: 90 3 isolation plugs, 90 2 open port plugs and 2 extended cross rods. 902 0 isolation discs 902 and 0 O-rings. 65 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- ommon Part Number Single Solenoid / Remote Pilot 4-Way, 2-Position (/8") & (/4") Inline Valves ouble Solenoid / Remote Pilot 4-Way, 2-Position Moduflex #4 Valve Only #2 68 #4 /8" SP #2 #4 Valve Only #2 268 #4 /8" SP #2 687 /8" NPT 0.6 v 2687 /8" NPT 0.6 v 6067 697 6097 /4" Tube /4" NPT 3/8" Tube.2 v 26067 2697 26097 /4" Tube /4" NPT 3/8" Tube.2 v Solenoids or Remote Pilot dapter must be ordered separately from page 67. Solenoids or Remote Pilot dapter must be ordered separately from page 67. Note: OL OPTIONS R MOST POPULR. 66 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Solenoids & Remote Pilot onnectors (/8") & (/4") Inline Valves & 3-Pin, 5mm Solenoids, Non-Locking, lush Override (w/o electrical connectors) Voltage 8mm Pin Spacing Kit Number 8mm Pin Spacing Solenoid Power onsumption 2V PS298245P P2-KV32.2W 24V PS298249P P2-KV32.2W 24V-50/60Hz PS298242P P2-KV3.6V 20V/60Hz PS298253P P2-KV3.6V 240V/60Hz PS298257P P2-KV3.6V Notes: Kit includes: solenoid, (2) machine screws, (2) self threading screws, () gasket, () 3-cell gasket. lectrical connectors must be ordered separately from the chart shown on page 68. Moduflex Remote Pilot onnectors (/8") & (/4") Valves Model Number PVP PVP5 Port itting 5/32" Tube 0-32 UN (M5) Supplied with two screws to quickly mate with the valve body. 67 Parker Hannifin orporation Pneumatic ivision

ä 0 ä atalog 0600P- lectrical onnectors Plug-In & emale lectrical onnectors emale lectrical onnectors 5mm 3-Pin IN 43650-8mm 2.3mm Top of light 2mm 22 W Wire 5mm Moduflex Molded 6' ord Shown onnector onnector escription with ord PS2932P PS2932HP 8 Inches Unlighted PS2932P PS2932P 6 eet Unlighted PS294675P PS294675P* 6 eet Light 2V or PS294679P PS294679P* 6 eet Light 24V or PS294683P PS294683P* 6 eet Light 0/20V PS294687P N/ Light 240/230V * L with surge suppression. Note: Max ø6.5mm cable size required for connector w/o 6' (2m) cord. IP65 rated when properly installed. ngineering ata: onductors: 2 Poles Plus round able Range (onnector Only): 4 to 6mm (0.6 to 0.24 Inch) ontact Spacing: 8mm 68 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- eatures 0 & 0 0 Series 0 Series Specifications 4-Way, 5-Port, 2 or 3-Position Valves Single & ouble Solenoid ual 3/2 Valves 0-0.6 v /8" NPT & SPP /4" & 6mm Tube Porting 0 -.2 v /4" NPT & SPP 3/8" & 8mm Tube Porting Mounting Style IN Rail Mounting (35mm) Stacking Manifold Valve Solenoid Pilot ctuation Low watt solenoid pilots:.2w/.6v Lights & Surge Suppression Standard 2V to 20V Operating Pressure 30 to 50 PSI (30 to 035 kpa) Operating Temperature 5 to 40 (-5 to 60 ) ertification / pproval pproved to be Marked IP65 3 5 0 Single Solenoid Shown e-nergized 3 5 0 3-Position P Moduflex Note: units are polarity sensitive. Pressure xhaust 69 Parker Hannifin orporation Pneumatic ivision

Moduflex atalog 0600P- Stacking System Overview Simplified lectrical Wiring liminate costly wiring of individual solenoids with compact 0 or 0 stacks of up to 6 modules with built-in electrical connectors. Simplified Setup single cable provides electrical connection to PL or special terminal block. 0 0 & 0 Stacking System Modular Stacking The modular stacking system permits easy assembly of valves and external connection modules into a single stack. Integral supply and exhaust ports are manifolded as the stack is assembled. Intermodular electrical connection is accomplished through integral 20-Pin electrical connectors, eliminating the need for harnessing or wiring within the stack. 0 single and double solenoid valves can be combined into one stack with the use of transition modules. 0 single and double solenoid valves can be combined into one stack without any transition modules. The electrical head / tail set provides a single electrical connection from the stack to a PL or terminal block. ach stack mounts easily to 35mm IN rail by means of a pneumatic head / tail set, which also provides common air supply and exhaust. 0 0 xternal onnections xternal connection modules with 0 valves allow sensor feedback or output connections to be integrated into the valve stack. 0 PL Stacking System enefits Reduces wiring, saves space. llows custom arrangements with standard components. urther reduces wiring by integrating feedback and output connections into the 0 valve stack. reatly reduces installation time and costs. Servicing valves can be accomplished quickly without disassembling the entire stack. 70 Parker Hannifin orporation Pneumatic ivision

lectrical onnection 0 & 0 Stacking System utoconfiguration 0 atalog 0600P- The construction of the stack determines the relationship of each connector pin and the device it is to control. The address of each solenoid valve and each feedback or output connection is based on its physical position in the stack. or 0, addresses are assigned consecutively from top to bottom and left to right beginning at top left with 0. or 0, addresses are assigned consecutively from left to right and beginning at top left with 0. 25-Pin onnector, ual Size Stack Maximum 2 ddresses 0 It is easy to add or remove one or more modules to adapt to machine modifications. Once the controller is programmed, however, it is recommended that, where possible, the addition or permanent removal of any module be done at the tail (right-hand) end of the stack to prevent affecting the addresses of other modules in the stack. change in address requires reprogramming of the controller. onnector Options 35-Pin onnector, ual Size Stack Maximum 32 ddresses 0 0 25-Pin onnector, Maximum 6 ddresses 25-Pin onnector, Single Size Stack Maximum 6 ddresses 7 Parker Hannifin orporation Pneumatic ivision Moduflex 0

atalog 0600P- ommon Part Numbers Single Solenoid 4-Way, 2-Position 0 Single & ouble Solenoid ouble Solenoid 4-Way, 2-Position Moduflex #4 #2 Valve Only 0 0687W2 2-24 V /8" NPT 0687W 24-20 V 06067W2 /4" Tube 2-24 V 0.6 v Valve Only 0 #4 #2 02687W2 /8" NPT 2-24 V 02687W 24-20 V 026067W2 /4" Tube 2-24 V 0.6 v 06067W 24-20 V 026067W 24-20 V ouble Solenoid 4-Way, 3-Position P ouble Solenoid ual 3/2 Normally losed P #4 #2 #4 Valve Only 0 07687W2 /8" NPT 2-24 V 07687W 24-20 V 076067W2 /4" Tube 2-24 V 076067W 24-20 V 0.6 v Valve Only 0 05687W2 /8" NPT 2-24 V 0.6 v 05687W 24-20 V #4 #2 Valve Only 0 08687W2 /8" NPT 2-24 V 08687W 24-20 V 086067W2 /4" Tube 2-24 V 086067W 24-20 V 0.6 v Notes: Solenoids sold separately on page 74. Part Numbers o Not include Solenoids. OL OPTIONS R MOST POPULR. 72 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- ommon Part Numbers Single Solenoid 4-Way, 2-Position 0 Single & ouble Solenoid ouble Solenoid 4-Way, 2-Position Valve Only 0 #4 #2 0697W2 /4" NPT 2-24 V Valve Only 0 #4 #2 02697W2 /4" NPT 2-24 V Moduflex 0697W 24-20 V 06097W2 3/8" Tube 2-24 V.2 v 02697W 24-20 V 026097W2 3/8" Tube 2-24 V.2 v 06097W 24-20 V 026097W 24-20 V ouble Solenoid 4-Way, 3-Position P ouble Solenoid ual 3/2 Normally losed Valve Only 0 #4 P 07697W2 /4" NPT 2-24 V.2 v 07697W 24-20 V #2 0 #4 Valve Only 05697W2 /4" NPT 2-24 V.2 v 05697W 24-20 V #4 #2 Valve Only 0 08697W2 /4" NPT 2-24 V.2 v 08697W 24-20 V Notes: Solenoids sold separately on page 74. Part Numbers o Not include Solenoids. OL OPTIONS R MOST POPULR. 73 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Ordering Information 0 & 0 Solenoids 0 & 0 3-Pin, 5mm Solenoids / Kits (8mm Pin Spacing) IN43650 Moduflex Voltages Power onsumption Holding urrent Id (rop-out urrent)* Kit Numbers With Non-Locking lush Manual Override Solenoid Only Kit Numbers With Locking lush Manual Override * When using a programmable controller, be sure that the leakage current of the controller outputs is lower than the drop-out current value. Notes: Kit includes: Solenoid, (2) machine screws, (2) self threading screws, () gasket, () 3-cell gasket, () L-shaped 3-cell gasket. Solenoid Only 2V.2W 00 m 0 m PS34445P P2-KS32 PS34445P P2-KS322 24V.2W 50 m 5 m PS34449P P2-KS32 PS34449P P2-KS322 24V.6V 65 m 22 m PS34442P P2-KS3 PS34442P P2-KS32 0V, 50Hz 20V, 60Hz.6V 3.3 m 5 m PS34453P P2-KS3 PS34453P P2-KS32 74 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stack onstruction onstructing a 0 Stack When constructing a stack, the following rules apply:. stack must have a pneumatic and an electrical head / tail set. 2. stack has a physical limit of 6 active modules (valves, feedback modules and output modules), regardless of whether they are double or single. 3. Single feedback and output modules must be stacked with single solenoid valves, and double feedback and output modules must be stacked with double solenoid valves. 4. ouble and single modules can be combined in a stack with the use of a transition module. stack order of double to single is recommended to maximize the number of possible addresses.! UTION: If the application requires simultaneous operation of valves and/or external connection modules, see Technical ata page for operating limits. ddressing ddresses are automatically assigned to each solenoid and each external connection based on its position in the stack. ddresses are numbered consecutively from top to bottom and left to right beginning at the top left of the stack with 0. To find the total number of addresses that will be required for a stack, calculate the following for each type of module based on table below and total: ddresses x Quantity of Units = ddresses Required Type of ddresses Quantity ddresses Module ssigned In stack Required ouble solenoid valve 2 x = ouble ck module 4 x = ouble output module 4 x = Single solenoid valve x = Single feedback module 2 x = Single output module 2 x = TOTL RSSS = lectrical onnection When selecting the electrical head / tail set, the following must be considered:. The size (double or single) of the electrical head piece must match that of the first module to its right. 2. The electrical connector must provide sufficient addresses for the stack. The number of addresses possible with each type of head / tail set is shown in the following table. ased on the head type needed, select the connector that provides sufficient addresses for the stack. 0 Modular Valve Stacking System 0 ouble Solenoid to Single Solenoid Valve Manifold with 25-Pin onnector: 6 valves 9 addresses ouble Solenoid to Single Solenoid Mixed Manifold with 25-Pin onnector: 5 active modules 0 addresses Head Type onnector Possible ddresses Single Solenoid 25-Pin 6 ouble Solenoid 25-Pin 2 35-Pin 32 Moduflex 75 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stack omponents & ccessories 0 Modular Valve Stacking System xternal onnection Modules With 20-Pin intermodular system and 2mm (mini) connectors, these modules can be combined with valves and/or other modules. eedback modules supply voltage to sensors and accept signals for communication back to the PL. eedback modules can be used for PNP or NPN sensors, indicator lights will only work on PNP sensors. Output modules allow connection and control of valves mounted externally from the stack. Type Size onnections Model Number Moduflex eedback Output Head / Tail Sets Pneumatic Single 2 Inputs 302 ouble 4 Inputs 2304 Single 2 Outputs S302 ouble 4 Outputs S2304 ouble Single Single air supply head / tail are used for shorter manifolds and dual air supply head / tail are used for longer manifolds. ual air supply head / tail sets contains 2 ported ends plus all hardware. lamps to 35mm IN rail. Removing 35mm hardware provides mounting holes for surface mounting. Single air supply head / tail sets clamp on one side only, ual air supply head / tail sets clamp on both sides. Type Port Size Model Number Single Supply ouble Supply /4" NPT 797 /4" SP 79 /4" NPT 7297 /4" SP 729 Single ir Supply Head / Tail Set ual ir Supply Head / Tail Set Pressure Isolating isc escription Sold in lots of 0. Model Number 902 lectrical or use with manifolds of all single solenoid valves or all double solenoid valves. Provides electrical link between all functions in the stack and the PL. Size onnector Model Number Single Solenoid 25-Pin (Male), -Sub 925 ouble Solenoid 25-Pin (Male), -Sub 9225 35-Pin (Male) 92235 or use with manifolds using both single and double solenoid valves. Provides electrical connection to PL and transition between single and double solenoid valves. Valve Order onnector Model Number ouble Solenoid then Single Solenoid Single Solenoid then ouble Solenoid 25-Pin (Male), -Sub 35-Pin (Male) 25-Pin (Male), -Sub 9425 94235 9325 Single Size Stacks ual Size Stacks 76 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stack onstruction onstructing a 0 Stack When constructing a stack, the following rules apply:. stack must have a pneumatic and an electrical head / tail set. 2. stack has a physical limit of 6 solenoids. 3. Single and double solenoid valves can be combined into one stack without any transition module.! UTION: If the application requires simultaneous operation of valves and/or external connection modules, see Technical ata page for operating limits. ddressing ddresses are automatically assigned to each solenoid and each external connection based on its position in the stack. ddresses are numbered consecutively from left to right beginning at the top left of the stack with 0. To find the total number of addresses that will be required for a stack, calculate the following for each type of module based on table below and total: ddresses x Quantity of units = ddresses Required Type of ddresses Quantity ddresses Module ssigned In stack Required ouble solenoid valve 2 x = Single solenoid valve x = TOTL RSSS = 0 Modular Valve Stacking System 0 25-Pin onnector with Intermediate ir Supply Module: 5 valves 7 addresses Moduflex Head Type onnector Possible ddresses 25-Pin 6 9-Pin 6 6 7 8 9 0 2 3 4 5 9-Pin onnector: 0 valves 6 addresses 77 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stack omponents & ccessories 0 Modular Valve Stacking System Head / Tail Sets lectrical / Pneumatic Port Size / Type onnector Model Number 3/8" NPT, Single -Sub, 25-Pin w/ xternal Pilot (Px) 273725 3/8" NPT, Single 3/8" NPT, Single -Sub, 25-Pin w/o xternal Pilot (Px) ircular, 9-Pin w/o xternal Pilot (Px) 73725 7379 Moduflex ir Supply Modules -Sub, 25-Pin ircular, 9-Pin Tail ir Supply Module to be mounted at the end of the manifold for dual air supply for longer manifolds. Intermediate ir Supply Module used when multiple pressures are required on a manifold. Port Size / Type Tail ir Supply Module Intermediate ir Supply Module 3/8" NPT PVUL237 PVUL237 3/8" SP PVUL23 PVUL23 Tail ir Supply Module Intermediate ir Supply Module Pressure Isolating isc escription Sold in lots of 0 Model Number 902 Pressure Isolating isc O-ring Transition Kits (0 to 0) Port Size / Type onnector Model Number /4" NPT to 3/8" NPT /4" NPT to 3/8" NPT /4" SP to 3/8" SP /4" SP to 3/8" SP Transition Kit with xternal Pilot (Px) Transition Kit without xternal Pilot (Px) Transition Kit with xternal Pilot (Px) Transition Kit without xternal Pilot (Px) 27379 7379 2739 739 78 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Pin ssignments -Sub, 25-Pin Single Size Head / Tail Set Pin No. Stack ddress Pin No. Stack ddress 3 0 8 0 25 20 2 2 7 2 24 3 9 3 4 6 4 23 5 8 5 0 6 5 Not Used 22 7 7 24V (feedback) (0) 9 8 4 0V (feedback) (0) 2 9 6 ommon 0v -Sub, 25-Pin ouble Size Head / Tail Set* eedback onnector* 4 2 Pin No. Stack ddress Pin No. Stack ddress 3 0 9 3 25 6 4 2 2 8 5 24 3 5 Not Used 4 7 24V (feedback) 23 5 4 0V (feedback) 0 6 6 ommon 0v 22 7 3 6 9 8 5 7 2 9 2 8 8 0 4 9 20 20 7 2 Output onnector* Pin No. I/O Pin No. I/O 24V (feedback) 2 2 3 0V (feedback) 3 ommon 0v 4 Input 4 Output 3 4 2 Notes: Solenoids are polarity sensitive. The common must be at 0V. Switching must be at the high potential. * vailable with 0 Only 0, 0 Modular Valve Stacking System 9-Pin ircular onnector K L M vailable with 0 Only T H U S V N P R ylindrical, 35-Pin type Trident Ringlock ouble Size Head / Tail Set* * vailable with 0 only. Pin No. Stack ddress 0 2 3 4 5 6 H 7 8 K 9 L 0 M N 2 P 3 R 4 S 5 T ommon 0V U Not Used V Not Used Pin No. Stack ddress Pin No. Stack ddress 0 V 8 W 9 2 X 20 3 Y 2 4 Z 22 5 a 23 6 b 24 H 7 c 25 8 d 26 K 9 e 27 L 0 f 28 M g 29 N 2 h 30 P 3 i 3 R 4 j ommon 0V S 5 k 0V (feedback) T 6 m 24V (feedback) U 7 K L M N a b c d P Z j k e R H Y i m f S X W h V g U T Moduflex 79 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Technical ata Technical Information Moduflex Operating Pressure Range: Single Pilot... 45 to 50 psi (3 to 035 kpa) ouble Pilot...30 to 50 psi (207 to 035 kpa) Temperature Range (mbient) Operating... 5 to 40 (-5 to 60 ) Storage... -40 to 58 (-40 to 70 )! UTION: If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior. Medium:... ry or lubricated air or inert gas Medium Quality: &...ry or lubricated air at 50 micron filtration Specific haracteristics escription /8" Valves () (0) Materials: ody...lass filled polyamide Seals...Polyurethane ittings...rass Mounting: Inline...Surface mount on flat surface Stacking...Mount on 35mm IN rail or flat surface Mounting Orientation:...ll positions Manual Overrides:... Locking or non-locking Lubrication Valves are pre-lubricated and may be operated with dry air. If lubrication is desired, use 442 oil. ycle Life:... 30 million (dry air) /4" Valves () (0) v 0.6.2 low Rates Threaded connector Instant tube fitting 6 5 4 PS (bar) P P 6 5 4 PS (bar) P P P = input pressure PS = output pressure 3 2 P 3 2 P 200 400 600 800 000 l/mn (NR) 7 28 35 SM 400 800 200 600 2000 l/mn (NR) 8 42 56 70 SM Port Sizes Instant tube fitting /4" 3/8" Threaded /8" Pipe /4" Pipe Maximum Valve itting Torque 7.4 ft-lb (0Nm) 4.8 ft-lb (20Nm) Head / Tail Port Size / Max. Torque /4" Pipe / 4.8 ft-lb (20Nm) 3/8" Pipe / 40.6 ft-lb (55Nm) or ir Operated Valves: Single cting ouble cting Single cting ouble cting Response Time (Input to Output)* 4 ms 8 ms 25 ms ms Pilot Pressure (@ 90 PSI Inlet) 44 psi 29 psi 44 psi 29 psi epilot Pressure (@ 90 PSI Inlet) 5 psi 22 psi Maximum Operating requency 5 Hz 0 Hz 5 Hz 0 Hz or Solenoid Operated Valves: Single cting ouble cting Single cting ouble cting Response Time (Input to Output)* 22 ms 2 ms 39 ms 7 ms Maximum Operating requency 5 Hz 0 Hz 5 Hz 0 Hz Power onsumption Hold =.2 Watt, =.6V =.2 Watt, =.6V Power onsumption Inrush =.2 Watt, = 3.5V =.2 Watt, = 3.5V Voltage Tolerance Standard Voltages +0% to -5% rated voltage @ 70 (20 ) 2 and 24 V 24 and 20 V Rated Insulation Voltage 500 Volts 500 Volts Protection Rating IP65 IP65 Standards (except 240 V) and N 79 300 * Valves tested with test chamber at 90 PSI inlet pressure. +0% to -5% rated voltage @ 70 (20 ) 2 and 24 V 24 and 20 V 80 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Technical ata lectrical haracteristics Standard Voltages: Solenoid... = 2 and 24 = 24V 50/60 Hz and 20V 60 Hz eedback module...24v (designed for sourcing sensor) Output module...24v Voltage Tolerance: +0% to -5% of rated voltage @ 70 (20 ) Power onsumption (Solenoid): Hold... =.2W... =.6V Inrush... =.2W... = 3.5V Rated urrents (Solenoid) Voltage Holding urrent Id (rop-out urrent)* 2V 00 m 0 m 24V 50 m 5 m 48V 25 m 2.5 m 24V 65 m 22 m 20V 3.3 m 5 m * When using a programmable controller, be sure that the leakage current of the controller outputs is lower than the drop-out current value. Maximum llowable urrents: Stack = 000 m ( mp) Output module = 000 m ( mp) eedback Module = 00 m (supply + load) Indication: y L one for each stack address 0 xternal onnection: Round connector M2 Protection Rating... IP65 0 & 0 Technical Information! Simultaneous Operation Some applications require simultaneous use of devices during setup or operation. Under normal single device operation, reliability can be assured by staying within the stated Maximum llowable urrents. uring simultaneous operation, however, the currents for each device must be added together with the total current not exceeding the 000 m ( mp) rating for the stack (example: only ten 2V solenoids can be operated simultaneously because their total accumulated current = 000 m). This is especially true for any connected external load when using the output module. While each output module is rated for 000 m, simultaneous operation of this load will reduce this rating. alculate maximum available current for any externally connected load during simultaneous operation according to the following formula: vailable urrent =,000 m - simultaneous current* * dd all solenoid currents based on system voltage and any other external load operating simultaneously. Type of urrent Quantity urrent evice Required (simultaneous) Used Solenoid m () x = m xternal Load (2) m (3) x = m Total Required urrent = m (4) () epending on system voltage (see Rated urrents ). (2) eedback modules use a separate common so are not used for this calculation, but total feedback current cannot exceed 000 m ( mp). (3) epending on device connected to the output module. Use rated current (m) for device or calculate: m = Watts/Volts x 000. (4) Must not exceed 000 m ( mp). Moduflex 8 Parker Hannifin orporation Pneumatic ivision

Moduflex atalog 0600P- able Pin ssignments Pin Out etail -Sub, 25-Pin onnector* PIN NO. 4 5 6 7 8 9 20 2 22 23 24 25 PIN NO. 2 3 4 5 6 7 8 9 0 2 3 0, 0 Modular Valve Stacking System Output Solenoid No. -Sub 25-Pin No. IP65 able olors Output Solenoid No. -Sub 25-Pin No. IP65 able olors 0 3 reen 0 8 lue / lack 25 Transparent 20 White / lack 2 2 ark lue 2 7 Khaki 3 24 Light lue 3 9 Orange 4 Pink 4 6 White 5 23 Purple 5 8 ray 6 0 ark reen / lack Not Used 5 Red / lack 7 22 Yellow Not Used 7 Red 8 9 Light reen / lack Not Used 4 rown 9 2 Yellow / lack Valve ommon 6 lack Notes: Solenoids are polarity sensitive. The common must be at OV. Switching must be at the high potential. * vailable with 0 Only. 9-Pin ircular onnector* K L M T H U S V N * vailable with 0 Only. P R Output Solenoid No. 9-Pin onnector IP65 able olors Output Solenoid No. 9-Pin onnector IP65 able olors 0 Pink / rown 0 L lue White / reen M Pink 2 White / Yellow 2 N rey 3 White / rey 3 P Yellow 4 White / Pink 4 R White 5 rown / reen 5 S reen 6 Red / lue Valve ommon T lack 7 H rey / Pink Not Used U rown 8 rown / Yellow Not Used V Red 9 K Violet Notes: Solenoids are polarity sensitive. The common must be at OV. Switching must be at the high potential. Maximum 6 solenoid outputs with one valve (negative) common line on Pin T. 35-Pin ircular onnector* H Z Y K L M N a b c d X j i W h k m V g * vailable with 0 Only. e f U T R S P Output Solenoid No. 35-Pin onnector IP65 able olors Output Solenoid No. 35-Pin onnector IP65 able olors 0 White / rown 8 V rown / Pink White / reen 9 W rown / lue 2 White / Yellow 20 X rown / Red 3 White / rey 2 Y rown / lack 4 White / Pink 22 Z reen / rey 5 White / lue 23 a reen / Pink 6 White / Red 24 b reen / lue 7 H White / lack 25 c reen / Red 8 rown / Yellow 26 d reen / lack 9 K Violet 27 e Yellow / rey 0 L lue 28 f Yellow / Pink M Pink 29 g Yellow / lue 2 N rey 30 h Yellow / Red 3 P Yellow 3 i Yellow / lack 4 R White 0 V valves j lack 5 S reen 0 V inputs k rown 6 T rown / reen 24 V inputs m Red 7 U rown / rey 82 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- ables able with emale -Sub, IP65 Rated, 25-Pin onnector 0, 0 Modular Valve Stacking System P8L-M255 5 Meters / 6.40 t onnection to the control system is through 20 colored wires W 24, rated at 2.5 amp. able with emale IP65 Rated, 9-Pin onnector Moduflex P8L-M95 5 Meters / 6.40 t onnection to the control system is through 9 colored wires W 20, rated at 5 amp. able with emale IP65 Rated, 35-Pin onnector P8L-M355 5 Meters / 6.40 t onnection to the control system is through 35 colored wires W 20, rated at 5 amp. 83 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stacking System 35mm IN Rail M200 6 eet Zinc chromated steel rail for easy mounting of stacks. IN rail can be mounted to grids or other surfaces to allow snap in mounting of pneumatic and electrical components. Stacking ccessories / Spare Parts 0.59 (5mm).38 (35mm) 0.06 (.5mm) Moduflex dapter Kits ontains a size transition module and a replacement tail piece for field conversion to a combination stack. 940 930 ouble then Single Single then ouble Pressure Isolation Kit Series Model Number Kit includes: 90 3 Isolation Plugs, 2 Open Port Plugs 90 and 2 xtended ross Rods. 902 902 0 Isolation iscs ssembly Instructions xample : Two different pressures P and P2 can supply the same bank of power valves, the exhausts remaining common. Valves 3 5 xample 2: omplete isolation of the commons in the same bank of power valves: main pressure and exhaust commons. xample 3: The exhaust commons can be isolated within the same bank of power valves, while the main pressure supply remains common. 3 5 3 5 xtended ross Rods 84 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- Stacking System Seals and askets Stacking ccessories / Spare Parts Series O-Rings askets 2 PPRV23 PPRV20 PPRV24 PPRV20 Series 0 0 O-Rings PPRV23 PPRV24 PPRV23 PPRV20 Notes: O-rings seal between stackable valve bodies. Sold in set of 30. 2 3-cell gaskets seal between pilot and valve body. Sold as one set of 20 gaskets. Moduflex ross Rods Series Model Number PPRV2 PPRV22 Used in valve stack mounting. Sold as set of 0 cross rods. IN Rail lip ssembly PPRL09 Head / Tail Set ll Sizes ssembly includes: clamp, screw, and spring. Sold as set of 20 each. 85 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions (/8") Valve & Stacking System Valves Single Solenoid Single Remote Pilot imensions (Inline Pipe) 2.40 (6) (Inline Tube) 2.80 (7) (Stacking Pipe) 2.40 (6) (Stacking Tube) 2.68 (68) 5.9 (50) 4.25 (08) 2 7.9 (20) 3 4.60 (7) 3.74 (95) Moduflex ouble Solenoid ouble Remote Pilot.5 (3).47 (2) 2.7 (55) Inches (mm).7 (8).79 (20) H 3.58 (9) /8" Pipe or /4" tube or 6mm tube for main ports. H 2 H 3 Stacking System T Single ir Supply imensions.50 (38) 3.27 (83) 2.76 (70) *.7 (4.2).39 (0).47 (2).3 (8) /4" R.73 (44) S.35 (9) S R n valves T.43 () ouble ir Supply Inches (mm) * learance for #6 screw. llen key (3 mm) n valves 86 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions (/4") Valve & Stacking System Single Solenoid Valves Single Remote Pilot imensions (Inline Pipe) 2.87 (73) (Inline Tube) 3.66 (93) (Stacking Pipe) 2.87 (73) (Stacking Tube) 3.27 (83) 7.00 (78) 5.35 (36) 2 8.94 (227) 3 5.62 (43) 4.84 (23).5 (3) 2.7 (55).98 (25).00 (26) H 4.6 (7) Moduflex ouble Solenoid ouble Remote Pilot.43 () Inches (mm) /4" Pipe or 3/8" tube or 8mm tube for main ports. H 2 H 3 T Single ir Supply Stacking System imensions.50 (38) 4.25 (08) 3.94 (00) *.7 (4.2).39 (0).47 (2).3 (8) 3/8" R 2.7 (55) S.35 (9) S R n valves ouble ir Supply T.5 (3) Inches (mm) * learance for #6 screw. llen key (4 mm) n valves 87 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions Transition Kits Transition Kits & Valves 2 n Valves n Valves Screw river 5 Moduflex imensions.98 (25) 2 3/8" 3.94 (00).7 (4.2).47 (2) /4" Inches (mm) 88 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions Single Solenoid 0 Modular Valve Stacking System ouble Solenoid imensions /8" NPT (SP) or /4" Tube (6mm) /8" NPT (SP) or /4" Tube (6mm) (Inline Pipe) 2.87 (73) (Inline Tube) 3.66 (93) (Stacking Pipe) 2.87 (73) (Stacking Tube) 3.27 (83) 5.43 (38) 6.97 (77).93 (49) 3.46 (88) 3.50 (89).7 (8).79 (20) Inches (mm).47 (2) Moduflex xternal onnection Modules Single ouble 2 mm (mini) emale onnector 2 mm (mini) emale onnector imensions 2.72 (69) 5.3 (35) 6.97 (77).8 (46) 3.46 (88) 3.50 (89).87 (22).47 (2) Inches (mm) Pneumatic Head / Tail Set.39 (0).5 (38).47 (2) /4" /4" n modules.5 (38).7 (4.2) 3mm llen Key 3.27 (83) To calculate stack length, add the width of the pneumatic and electrical head / tail sets plus (quantity x width) for each type of active module. Widths shown in inches (mm). Module Qty Width Total Width Pneumatic head / tail set x 3.00" (76) = 3.00" (76) lectrical head / tail set: x = Select 25-Pin head / tail.73" (44) or 25-Pin w/ transition 2.60" (66) or 35-Pin head / tail 2.76" (70) or 35-Pin w/ transition 3.62" (92) Valves x.7" (8) = eedback/output modules x.87" (22) = TOTL STK LNTH = 89 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions 0 Modular Valve Stacking System lectrical Head / Tail Sets* Single Stack -Sub, 25-Pin onnector imensions 2.48 (63) 2.40 (60) 5.3 (35) 6.97 (77).8 (46) Moduflex ouble Stack -Sub, 25-Pin onnector * When the stack contains both single and double modules, you must use a head / tail set that includes a size transition module (shown below). 3.46 (88).47 (2) 3.50 (89) K.89 (48) Inches (mm).39 (0).87 (22) ylindrical 35-Pin ouble Size Head / Tail Set H.57 (40) H K Size Transition Module imensions.87 (22) 6.97 (77) Inches (mm) 90 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions Single Solenoid 0 Modular Valve Stacking System ouble Solenoid 4 2 /4" NPT (SP) or 3/8" Tube (8mm) 5 2 4 3 5 3 4 2 /4" NPT (SP) or 3/8" Tube (8mm) Moduflex imensions (Inline Pipe) 2.87 (73) (Inline Tube) 3.66 (93) (Stacking Pipe) 2.87 (73) (Stacking Tube) 3.27 (83) 6.50 (65) 2.56 (65) 3.94 (00).00 (25.4).3 (33) Inches (mm).00 (25.4).47 (2) -Sub, 25-Pin onnector K ylindrical onnector K x Px 5 3 /4" NPT (SP) or 3/8" Tube (8mm) x Px 5 3 /4" NPT (SP) or 3/8" Tube (8mm) imensions imensions 2.75 (70) 6.22 (58) 2.28 (58) 3.94 (00).65 (42) 2.75 (70) 6.22 (58) 2.28 (58) 3.94 (00).65 (42).06 (27).39 (0) K.2 (3).06 (27).39 (0) K.30 (8) Inches (mm) Inches (mm) 9 Parker Hannifin orporation Pneumatic ivision

atalog 0600P- imensions 0 Modular Valve Stacking System Intermediary ir Supply Module Moduflex 5 3 /4" NPT (SP) or 3/8" Tube (8mm) imensions 2.94 (75) 6.22 (58) 2.28 (58) 3.94 (00).08 (28).06 (27).47 (2) Inches (mm) Transfer Module x Px 5 3 /4" NPT (SP) or 3/8" Tube (8mm) imensions 2.75 (70).06 (27) 6.22 (58).39 (0) Inches (mm) 2.28 (58) 3.94 (00).65 (42) 92 Parker Hannifin orporation Pneumatic ivision