FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Similar documents
UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

Fire damper FK120/FK90 TECHNICAL DATA

Smoke damper EKO-SRB1

Fire/smoke damper EKO-SRBG1

Fire/smoke damper EKO-JBG2

Bevent Rasch BSK Fire /04/2017

Combustion gas damper EKO-SRB

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBL

ESAS Smoke control damper

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Bevent Rasch BSK6. - Fire /04/2017

TYPE EK-EU SMOKE CONTROL DAMPER

Systemair Fire Dampers

PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

PKI-C Cartridge Fire Dampers

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

7/S5 FIRE DAMPER FD40. v 2.9 (en)

M A D E L. FOK-EIS-180 Fire dampers CE

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Fire dampers ETCE and ETCS TECHNICAL DATA

Rectangular fire damper TFER 30. pag. C-10

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

Combustion gas damper EKO-JB

Systemair Fire Dampers

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

CFSD Series. Product Description

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

PKIR3G, PKIS, PKIS3G and PKIS3GA

VAV TERMINAL BOXES TYPE: BA BT

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

Pressure control damper ERPA

SMOKE CONTROL DAMPERS

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Motorized Fire Dampers

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

VOLUME CONTROL / REGULATING DAMPERS

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Actionair Control and Shut Off Dampers

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Ceiling swirl diffusers

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Regulation and shut-off damper SPB and SPC

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE:

series FSD-FLD Fire and smoke dampers UL Approval

SFD-EN Smoke/Fire Dampers

OPTIVENT Housing HVSA, HVSL

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

CU2-15. Rectangular fire damper 120' at 1500 Pa. C7-EN-I 06/2018

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

J L I e x h a u s t h o o d

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Heights up to 1000 mm Fire resistance period up to 120 minutes

Zest Iris Duct Dampers

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

series RVV Variable flow rate controllers

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

IrisControlDamper. For Adjustment and Measuring of Airflow.

Ceiling swirl diffusers

CU2/B. Battery assembly of max. 4 individual dampers. C31-EN-G 06/2018

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Mechanical mixing box MBM

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

The VX-6 smoke control dampers are designed for smoke control systems in buildings outfitted with a one-stage

Smoke control damper RKI-90 Test certificate Z

to obtain the specified voids due

ROOFMASTER STEF-HT ROOF FAN

GDD - Supply Grille. Halton GDD. Supply Grille

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Transcription:

Halton FDR Fire Damper for Rectangular and Circular Ducts Type-approved and compliant with the EN 1366-2 and EN 13501-3 standards. Design for installation in separating concrete and masonry walls and ceilings and lightweight plasterboard walls of fire compartments with fire resistance class EIS 30 to EIS 120. Readiness for installation with all wall options as delivered no additional frames needed. Manufactured in accordance with the ISO 9001 quality system. VTT, the Technical Research Centre of Finland, is responsible for external quality control. Installation in rectangular and circular ducts with diameter 630 to 1000 mm. Available with motorised or manual actuator. Double sealing, ensuring that the blades are tight when the fire damper is closed before and during a fire. Fire damper casing complying with the tightness requirements for Class C, EN 1751. Fire damper tightness meeting smoke damper requirement S of standard EN 1366-2. Suitability for use in ducts with a maximum pressure of 2800 Pa. Damper closing tests performed at 15 m/s duct velocity. Product models and Accessories Models equipped with either manual or electric actuators. 1

DIMENSIONS W/H: 200, 250, 300, 400, 500...1000 When the damper is installed on concrete and masonry walls or ceilings, the size of the installation hole is W/H + 100 mm. When the damper is installed on lightweight walls, the size of the installation hole is W/H + 110 mm. FDR Ø WxH D-1 La Lb C L L+2xC 630 600x600 629 266 354 52 620 724 800 800x800 799 366 454 58 820 936 1000 1000x1000 999 466 554 58 1020 1136 Pressure drop and sound data Sound power level Lw, in in each octave band is computed bu adding the corresponding correction factor, Kok, to the sound pressure level in the selection chart according to the following equation. Lw = LpA + Kok The corresponding factor Kok is the average of the FDR operating area. 2

3

Material and finishing The FDR fire damper casing, installation flange, and installation frame are made of galvanised steel. The closing blade is made of calcium silicate and equipped with a flexible silicone seal as well as a graphite mass seal that expands at high temperatures. Product options and Accessories Actuators Manual actuator, MA (spring return) Electrical actuators ºC, contains a microswitch), B1 Belimo BF230-T-2 HL, operating voltage AC 230 V (72 ºC, contains a microswitch), B2 Model for Sweden: Belimo BF24 HL, operating voltage AC/DC 24 V (no fuse, contains a microswitch), B5 Belimo BF230 HL, operating voltage AC 230 V (no fuse, contains a microswitch), B6 Accessories Safety mesh on one side, N1 Safety mesh on both sides, N2 Models for Europe and Russia: Belimo BF24-T-2 HL, operating voltage AC/DC 24 V (72 Manual actuator accessories Fuse release temperatures, FU = 50 ºC, 65 ºC, 72 ºC, 100 ºC Limit switches, open and closed position, MS Function The FDR is a fire damper of class EIS 30 to EIS 120 for circular or rectangular ducts, which prevents fire and smoke from spreading in ventilation ducts. The fire damper is equipped with either a motorised actuator or manual actuation arrangement. Both actuators have a visual position indicator. If the power in the motorised actuator system is switched off, the blade closes automatically. Europe and Russia models: In both actuator options, a fuse reacts to a rise in temperature, causing a spring-return blade to close. The motorised fire damper is delivered complete with a spring-return actuator and a fuse that is activated at 72 ºC. Sweden model: The electrical motor option is without thermal fuse and shall be connected to an automatic alarm system. The fire damper is made of fireproof materials. Once the fire damper has closed, the double sealing closes the duct tightly, effectively preventing the spreading of flue gases in the ventilation ductwork. The flexible seal of the double sealing system operates at lower temperatures, while the graphite mass seal expands to insulate the system at temperatures above 150 ºC. The FDR fire damper can be connected to the MSH control and testing system for fire dampers. The MSH unit enables the use of smoke detectors in the ductwork or rooms. The FDR fire damper can also be connected to other common building automation systems. Installation Installation on masonry walls When the fire damper is installed on concrete and masonry walls and ceilings between fire compartments, the blade shaft is always horizontal. An opening is always left in the separating element for the fire damper, and the product is subsequently grouted into this. To make installation easier, all products come with 4

an installation flange, which is used to fasten the fire damper to the concrete surface with screws before grouting. During installation, the fire damper and actuator must be protected with, e.g., a plastic cover. The correct operation of the fire damper must be ensured before and after grouting. When the damper is installed for concrete and masonry walls and ceilings, the size of the installation hole is W/H + 100 mm. Installation on lightweight plasterboard walls When the fire damper is installed on lightweight plasterboard walls between fire compartments, an opening for the fire damper must be left on the plasterboard in which the installation frame (included in the delivery) is first mounted. The blade shaft must always be horizontal. To make installation easier, the fire damper comes with an installation flange, which is used to fasten the fire damper to, e.g., the steel frame of the panel wall. The space between the fire damper and the installation frame is filled with a fire prevention mastic. During installation, the fire damper and actuator must be protected with. e.g., a plastic cover. The correct operation of the fire damper must be ensured after application of the fire prevention mastic. For lightweight walls, the size of the installation hole is W/H+110 mm; consult the section Documents / Installation Instructions for the size of the installation holes. K2: 13/14 open K2: 13/14 open K2: 13/14 closed 21/22 closed 21/22 closed 21/22 open Suggested specifications A fire damper of class EIS 30 to EIS 120 shall have a double sealing solution that ensures fire-gas resistance at all temperatures when the fire damper is closed. In motorised models, the fuse shall be activated at 72 C (E and R models). In the manually operated system, the fuse activation temperature corresponds to the specifications (50, 65, 72, 100 C). The fuse shall be located inside the damper, and it shall be possible to replace it from the outside. The fire damper shall have means for external opening / triggering of the release and closing. The fire damper shall include a position indicator. The fire damper shall be suitable for vertical and horizontal installation on concrete and masonry walls and on ceilings or lightweight plasterboard walls between fire compartments (EIS 30 to EIS 120). The technical properties of the type-approved fire damper shall conform to the EN 1366-2 and EN 13501-3 standards. The internal quality control of the fire damper manufacturer shall be based on the ISO 9001 quality system system, and the operations of the manufacturer shall be subject to external third-party quality control. Detailed installation instructions, as well as an installer s installation certificate form, are supplied with each product. See also the section Documents / Installation Instructions. Electric actuator wiring diagram Product code S = Model E S R Europe Sweden Russia BF24-HI BF230-HI BF24-T HI BF230-T HI Manual actuator wiring diagram (limit switches, MS) Damper open Damper drives Damper closed K1:13/14 closed K1: 13/14 open K1: 13/14 open 21/22 open 21/22 closed 21/22 closed A = Type of duct connections R Rectangular A Duct connection 630 B Duct connection 800 C Duct connection 1000 W = Width A = R: 200, 250, 300, 400, 500, 600, 700, 5

800, 900, 1000 A = A: 600 A = B: 800 A = C: 1000 H = Height A = R: 200, 250, 300, 400, 500, 600, 700, 800, 900, 1000 A = A: 600 A = B: 800 A = C: 1000 Specifics and Accessories RE = Release type MA Spring release B1 BF24-T-2 HL fuse 72 C (E and R models) B2 BF230-T-2 HL fuse 72 C (E and R models) B5 BF24 HL, no fuse (S model) B6 BF230 HL, no fuse (S model) FU = Fuse release temperature ( C) 50 C, 65 C, 72 C, 100 C AC = Accessories MS Limit switches N1 Safety mesh, 1 side, installed in actuator side N2 Safety mesh, 2 sides Code example FDR/E-R-200-200, RE=MA, FU=72 6