Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Similar documents
Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

F-2600 SERIES INLINE VORTEX FLOW METER

Armstrong In-Line and Insertion Vortex Flow Meters

F-2700 SERIES INSERTION VORTEX FLOW METER

Range of Ultrasonic Flowmeters.

F-1500 SERIES INSERTION TURBINE FLOW METER

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Model FVP General Specification. Flanged Vortex Plate. Product Features

F-2700 SERIES INSERTION VORTEX FLOW METER

VLM20 In-line Vortex Flowmeter

ISTEC MAGNETIC METERS

F-2600 SERIES INLINE VORTEX FLOW METER

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Vortex Plate. Model VP General Specification. Product Features

BARTON 7400 Precision Gas Turbine Flow Meters

Multivariable Vortex Flow Meter

The readings you need, right where you need them. AX Series Vortex Meters

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Low Profile Insertion Vortex

VIM20 Vortex Insertion Flowmeter

Hot Tap Insertion Vortex

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Multivariable Vortex Flow Meter

VIM20 Vortex Insertion Flowmeter

Appendix. Clearance. Skewed profiles. Application Schematics

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Rosemount 3051CFA Annubar Flowmeter

Vortex Flow Meter Model DVH

F-2500 SERIES VORTEX METER

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

VIM20 Vortex Insertion Flowmeter

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

tprime TM Series 280T

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

The readings you need, right where you need them. AX Series Vortex Meters

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

DFX Series Liquid Ultrasonic Flow Meters

ULTRASONIC HEAT METER

RIM20 Rotor Insertion Flowmeter

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

VORTEX IN-LINE FLOW METERS

Vortex Flowmeter Model DVE

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

flow measurement solutions RIM10 series rotor insertion flowmeters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Vortex In Line Flow Meter

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Rosemount 3051T In-Line Pressure Transmitter

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

Rosemount 3095FT MultiVariable Flow Data Logger

Vortex In Line Flow Meter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

mass flowmeter for compressed air

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Rosemount 8800D Series Vortex Flowmeter

AquaTrans AT600. Panametrics Clamp-on Ultrasonic Liquid Flow Meter. Imagination at work. Version 3 (12/1/14)

Rosemount DP Flowmeters and Primary Elements

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

4.30 [109] 5.43 [138] FCI FlexMASSter ST98 Series: The Best Value in a 8.00 [203] High Performance. Flange. Mounting Hole. Positioning to Split Flow

OPTIMASS 2000 Technical Datasheet

Full Profile Insertion

UTM10 Series Ultrasonic Transit-time Flowmeters

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Smart Products. Maxon Workshop Richard Reyes

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

HTM Series Helical Turbine Meters

Coriolis Mass Flowmeter for low flow measurements

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Rosemount 8800D Series Vortex Flowmeter

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Rosemount 4088 MultiVariable Transmitter

Micro Motion 7827 Digital Viscosity Meter

Electromagnetic Flowmeters. Product Overview.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

RHM 60. Coriolis Mass Flowmeter for Medium Flow also Suited for High Pressure Applications. Applications. Advantages. Features

ThermoPro TM Series TP10

Hydro-Flow Model 3100

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

220 Series Innova-Flo o

Transcription:

GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage Pipeline balancing Power systems Gas processing Compressor station metering Gas production Fuel monitoring Features Netherlands Measurement Institute (NMi) approval Compliant with AGA Report #9 Accuracy 0.1% of reading Isolated from upstream flow disturbances 40:1 or better turndown ratio

High Accuracy for Custody Transfer Applications The Sentinel ultrasonic flowmeter is designed to meet the high-accuracy requirements of AGA9 for natural gas custody transfer, as well as the NMI pattern approval. A Sentinel meter body is composed of a length of carbon steel pipe with flanged ends, rated to the pressure requirements of the individual installation, and two pairs of pre-installed ultrasonic transducers. The system is factory assembled and tested to ensure that it meets strict quality control standards. 1.5 Advanced Ultrasonic Transducer Technology High Power for High Velocity The heart of ultrasonic measurement is the transducer. The Sentinel T11 transducer is specifically designed for natural gas applications. Our transducers provide high transmission power through the gas, ensuring optimal performance under high flow conditions of up to 118 ft/sec (36 m/s). The robust all-welded metal design ensures resistance to corrosion and pressure cycling. The transducer frequency is matched to the pipe size of the system ordered. In addition, the Sentinel transducer holder includes unique acoustic isolation characteristics that allow optimal performance, even in noisy applications such as wet natural gas. Percent Error 1.0 0.5 0.0-0.5-1.0 Percent Error -1.5 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 6 in NMi certification 6 in unit #2 6 in unit #3 8 in China pattern approval 12 in NMi certification 16 in Unit #1 AGA9 limits Sentinel performance plots, various size flow cells 1.5 1.0 0.5 0.0-0.5-1.0 Percent of Maximum Flow Sentinel T11 transducer How Correlation Transit-Time Measurement Works Ultrasonic transducers are installed in the meter body, one upstream of the other. The transducers send and receive ultrasonic pulses through the fluid. The meter measures the difference between the upstream and downstream transit times, and uses digital signal processing and correlation detection to calculate velocity and volumetric flow rate. -1.5 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 725 psi (50 bar) 290 psi (20 bar) 116 psi (8 bar) AGA9 limits Percent of Maximum Flow Sentinel performance plots, same flow cell at various pressures Upstream transducer Downstream transducer Fluid flow Upstream transducer Ultrasonic signal paths Downstream transducer Transit-time flow measurement technique

System Design A complete Sentinel system consists of the ultrasonic meter, flow conditioner, and upstream/downstream piping. This configuration removes the uncertainty associated with installation effects (distorted flow profile caused by valves, elbows, other piping system components) on the overall meter performance. This solution provides a simplified, yet cost effective metering system without exposing the user to any additional risk in measurement uncertainty. Customers can be assured of accurate flow measurements because flow profile, a major source of uncertainty if not fully developed and uniform, is removed from the overall equation in the ultrasonic flowmeter system. Flow conditioning plate (included, but not shown) 5-diameter Sentinel flowmeter (included with system) 10-diameter (included with system) Bidirectional Sentinel flowmeter installation Pressure transmitter tap Flow Conditioning System Flow conditioning plate (included, but not shown) 10-diameter (included with system) Temperature transmitter tap (3-diameter downstream minimum) 5-diameter Flow conditioning plate (included, but not shown) Sentinel flowmeter (included with system) 5-diameter 10-diameter (included with system) Pressure transmitter tap 5-diameter Temperature transmitter tap (3-diameter downstream minimum) The Sentinel system includes a flow profile conditioning plate and a straight pipe run of ten diameters upstream of the Sentinel meter body. The system requires the customer to provide a minimum of five-diameter straight pipe run both upstream and downstream of the installation. When used in a bidirectional flow application, the Sentinel system includes an additional flow profile conditioning plate and ten diameters of straight pipe run on the downstream side of the flowmeter. The customer-provided five-diameter pipe runs upstream and downstream are still required. The Sentinel path configuration is designed such that a minimum number of paths interrogates the maximum area of the pipe, resulting in measurement stability and superb repeatability. In addition, the meter uses no bounced or multiple bounced paths susceptible to signal distortion from build-up on walls and adversely affected by ultrasonic noise (often from upstream piping and valving) and high flow velocity. The straight single path provides a solid measurement and maximizes the longterm performance of the meter. The Sentinel flow metering system operates with a better than 5 Hz response rate, depending on pipe size, using a sophisticated multi-mode signal processing technique that delivers accurate and dependable meter performance with high turndown. This fast sampling ensures that system accurately measures flow under dynamic and pulsating flow conditions. Error, Percent 2.0 1.5 1.0 0.5 0.0-0.5 IGM Program Error Limits -1.0 AGA9 Error Limits -1.5-2.0 0 5 10 15 20 25 30 35 Straight Run Reference Velocity (ft/s) Single Elbow Double Elbow (In Plane) Double Elbow (Out of Plane) Double Elbow (Out of Plane) with Half Moon Obstruction Corrected error percent vs. velocity, 10 in (25 cm) IGM spool with CPA-50E (Name CPA-50E used with permission), 3.5 Dup/10 Ddown, repeat runs

Performance in Air/Natural Gas (NG) at Atmospheric Pressure Although Sentinel is designed to operate at natural gas transmission line pressures, it has been proven to work well in air at ambient pressure. This is made possible by Sentinel s advanced ultrasonic transducers and the associated electronics and signal-processing platform used. There is no minimum pressure requirement for proper operation of the metering system. In addition, variable pressures exhibit virtually no effect on the Sentinel s flow measurement. Meter performance can be verified in the field during commissioning using atmospheric pressure air to ensure the meter system is ready to go when needed. Thus, customers will have a high degree of confidence in the installation and performance of the meter prior to line pressurization with natural gas. Removable Transducer Option The Sentinel flowmeter is available with optional isolation valves on each installation port. This permits the removal of transducers under process pressure. A single hydraulic ram system is required for safety and to simplify the reinstallation process. Convenient Installation The Sentinel flowmeter electronics are preprogrammed with all system setup information. The system is ready to use as soon as the meter body is installed and the power and meter communications are wired. No additional setup or configuration are needed. Sentinel flowmeter system Monitor meter calibration data collection, configuration and security 1 or 2 frequency 1 Alarm 2 Analog outputs (4 to 20 ma) 2 Analog inputs RS485 Modbus protocol RS232 or RS485 Pressure Flow computer Z Corrected volumetric flow Super compressibility Gas comp. Temperature PanaView instrument interface software Energy content (BTU) Typical system configuration. PanaView software provides a communication interface between the Sentinel system and a laptop PC. PanaView Instrument Interface Software cf Energy PanaView software facilitates communication between a PC and the Sentinel system or other GE Sensing products. This software monitors your Sentinel flowmeter to provide a secure, comprehensive check on meter configuration with a full audit trail. It also allows live flow readings and tracking of flow diagnostics. Example of PanaView display

Nominal Pipe Size Weight Flange Class (ANSI B16.5) Face-to-Face *Height h *Width w Distance in (mm) 300 lb 600 lb 900 lb in (mm) in (mm) in (mm) 4 (100) 236 lb (107 kg) 270 lb (122 kg) 304 lb (138 kg) 32 (813) 35 (889) 34 (864) 6 (152) 387 lb (176 kg) 473 lb (215 kg) 568 lb (258 kg) 45 (1143) 37 (940) 36 (914) 8 (203) 470 lb (213 kg) 593 lb (269 kg) 794 lb (360 kg) 48 (1219) 39 (991) 38 (965) 10 (254) 581 lb (264 kg) 832 lb (377 kg) 1048 lb (475 kg) 52 (1321) 42 (1067) 40 (1016) 12 (305) 731 lb (332 kg) 1014 lb (460 kg) 1401 lb (635 kg) 56 (1422) 44 (1118) 42 (1067) 14 (356) 905 lb (411 kg) 1331 lb (604 kg) 1881 lb (853 kg) 58 (1473) 46 (1168) 44 (1118) 16 (406) 1067 lb (484 kg) 1747 lb (792 kg) 2302 lb (1044 kg) 60 (1524) 48 (1219) 46 (1168) 18 (457) 1259 lb (571 kg) 2031 lb (921 kg) 3003 lb (1362 kg) 63 (1600) 50 (1270) 48 (1219) 20 (508) 1528 lb (693 kg) 2557 lb (1160 kg) 3765 lb (1708 kg) 67 (1702) 53 (1346) 50 (1270) 24 (610) 2255 lb (1023 kg) 3691 lb (1674 kg) 6386 lb (2897 kg) 74 (1880) 57 (1448) 54 (1372) *Extra clearance needed for insertion mechanism w h Nominal Pipe Diameter Velocity (ft/sec) Actual Volumetric Flow Rate (ACFM) in (mm) minimum maximum minimum maximum 4 (100) 3.8 118 18 626 6 (152) 2.4 118 26 1420 8 (203) 2.4 118 46 2460 10 (254) 2.4 118 72 3877 12 (305) 1.5 89 64 4151 14 (356) 1.5 89 77 5017 16 (406) 1.5 89 101 6553 18 (457) 1.5 89 128 8295 20 (508) 1.5 89 158 10,307 24 (610) 1.5 89 228 14,908 Nominal Pipe Diameter Velocity (m/sec) Actual Volumetric Flow Rate (m3/hr) in (mm) minimum maximum minimum maximum 4 (100) 1.15 36 34 1064 6 (152) 0.72 36 44 2416 8 (203) 0.72 36 76 4183 10 (254) 0.72 36 120 6593 12 (305) 0.45 27 106 7019 14 (356) 0.45 27 128 8483 16 (406) 0.45 27 168 11,082 18 (457) 0.45 27 213 14,027 20 (508) 0.45 27 264 17,430 24 (610) 0.45 27 382 25,209

Sentinel Specifications Operation and Performance Meter is designed to meet or exceed the requirements of AGA Report Number 9. Fluid Types Natural gas (other gases available upon request) Pipe Sizes 4 in to 24 in (100 mm to 600 mm) Other sizes available upon request. Meter Body Materials Carbon steel (A106 Gr. B or A333 Gr. 6) pipe section with carbon steel (A105 or A350 LF2) flanges and fittings Specify A333 Gr. 6 and A350 LF2 for low-temperature service. Maximum Error (Without Flow Calibration) ±0.5% between 0.1 Qmaximum* and Qmaximum ±1.0% between Qminimum and 0.1 Qmaximum* Repeatability 0.08% between 0.1 Qmaximum* and Qmaximum 0.15% between Qminimum and 0.1 Qmaximum* Resolution 0.003 ft/s (0.001 m/s) Velocity Sampling Interval 0.2 seconds Maximum Peak-to-Peak Error ±0.2% between 0.1 Qmaximum* and Qmaximum *(0.15 Qmaximum for 4 meter size) Zero Flow Reading <0.007 ft/s (.00213 m/s) for each acoustic path <0.01 ft/s (.00305 m/s) composite for all paths Accuracy can be improved with high pressure NG flow calibration. Meter Performance Flow calibrated accuracy is 0.1% of reading relative to lab Absolute accuracy is 0.3% including lab uncertainty Specifications assume 5 diameters upstream and 5 diameters downstream of straight pipe run in addition to the pipe run and flow conditioning plates provided with the Sentinel system, and a flow velocity greater than 5 ft/s (1.5 m/s). For Pipe Sizes 4 in to 10 in (15 cm to 25 cm) Maximum actual measurable velocity: ±118 ft/s (±36 m/s) Minimum actual measurable velocity: ±2.4 ft/s (±0.72 m/s) Transitional flow velocity: 11.8 ft/s (3.6 m/s); QT = 10% (QT = 15% for 4 meter size) For Pipe Sizes 12 in to 24 in (30 cm to 61 cm) Maximum actual measurable velocity: ±88.6 ft/s (±27 m/s) Minimum actual measurable velocity: ±1.48 ft/s (±0.45 m/s) Transitional flow velocity: 8.86 ft/s (2.7 m/s); QT = 10% Maximum operating gas pressure @ 176 F (80 C) MAOP psig (bar) Electronics ANSI Flange Class 300 lb 600 lb 900 lb 690 psig (47 bar) Flow Measurement Correlation Transit-Time mode Enclosures US: Epoxy-coated aluminum Weatherproof Type 4, IP66 Class I, Division. 1, Groups B,C&D FM and CSA European: Flameproof II 2 GD EEx d IIC 1381 psig (95 bar) Dimensions Main enclosure Weight: 10 lb (4.5 kg), Size (h x d): 8.2 x 6.6 in (208 x 168 mm) 2072 psig (143 bar) Power Enclosure Weight: 25 lb (11.3 kg), Size (l x h x d): 15 in x 10 in x 8 in (381 mm x 254 mm x 203 mm) Display 2-line x 16-character LCD display, LED backlight, configurable to display up to four measurement parameters in sequence Power Supplies Standard: 95 to 240 VAC ±10%, 50 to 60 Hz ±2% Optional: 17 to 32 VDC, ±10% Note: For DC-powered meters, Class 2 rated supplies must be used for the line power.

Power Consumption 20W maximum Operating Temperature 40 C to 60 C ( 40 F to 140 F) Storage Temperature 55 C to 75 C ( 67 F to 167 F) Standard Inputs/Outputs Two 0/4 to 20 ma isolated outputs, 600 W maximum load One frequency (HF) output, optically isolated, from DC to 10 khz maximum One hermetically sealed Form C alarm relay. Can be applied to indicate flow direction or fault. Two isolated 4 to 20 ma inputs and 24 V loop power for pressure and temperature Optional 2 HF outputs and two alarm output or 1 HF output and 4 to 20 ma inputs Digital Interfaces Bidirectional RS232 or RS485 link to PanaView Software RS485 Modbus digital output Materials Transducer: Titanium CP Gr. 2 (B348/B381) Transducer holder: Stainless steel 316/316L (A276)C Area Classifications North America: Explosion-proof Class I, Division 1, Groups B,C,&D European: Flameproof II 2 G EEx d II PED 97/23/EC Transducer Cables Integrated cables: Potted mineral insulated cable (North America) or armored cable with ATEX-certified cable glands (European) Metrological Approval for Sentinel NETHERLANDS Audit Capacity Password security protected Log file of all critical parameters not erasable Totalizer hardware secured/seal European Compliance System complies with 73/23/EEC LVD (Installation Category II, Pollution Degree 2), PED Cat III, Module H Wetted T11 Ultrasonic Flow Transducers Temperature Range 30 C to 80 C ( 22 F to 176 F) Pressure Range 300 lb ANSI flange class: 740 psig (51 bar) maximum allowable operating pressure at 100 F (38 C) 600 lb ANSI flange class: 1,480 psig (103 bar) maximum allowable operating pressure at 100 F (38 C) 900 lb ANSI flange class: 2220 psig (153 bar) maximum allowable operating pressure at 100 F (38 C) Other pressure rating available upon request.

g www.gemeasurement.com 920-055F 2016 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.