Smile 11 RA/-B Smile 12 RF/-G Reset button

Similar documents
Tina 11A Connection block

Tina 10A/B/C Adaptor unit

Tina 4A Connection block

FMC-1/2 Tina Muting unit

Smile 41 Push-button box with/without emergency stop

Sense7-series Non-contact coded safety switch

EStrong-series Emergency Stop

Eden AS-i Proximity safety sensor

MKey9-series Safety Interlock Switch with Guard Locking

Please note! This model of Eden is obsolete and has been replaced by Eden DYN. Original instructions Eden Non-contact safety sensor

Knox Safety and process lock

Original instructions Eden OSSD Coded non-contact safety sensor

Eden OSSD Coded non-contact safety sensor

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

2NC (slow-action) Direct. Model. opening

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

Digital display Pressure range ON/OFF output Linear output Model

G3PE-Single-phase. Solid State Relays for Heaters

Multiple Limit Switch

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

A165E CSM_A165E_DS_E_11_2

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Model Number Structure

S8JX-N/S8JX-G Series Replacement Brackets

D4BS CSM_D4BS_DS_E_8_4

Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

D4GS-N CSM_D4GS-N_DS_E_7_2

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

DIN Track Terminal Blocks with Screw Terminals XW5T

Safety Roller Door RD344

Safety stop buttons Smile, INCA and Compact

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

2NC (slow-action) Direct. Model. opening

Better Productivity by Standstill and Low-speed Monitoring

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

D4BL. Guard Lock Safety-door Switch

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Safety Guard Switching Unit G9SX-GS

D4BL. Guard Lock Safety-door Switch

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Safety Limit Switch

A22LK CSM_A22LK_DS_E_6_2

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Cylindrical photoelectric sensors in M18 plastic or brass housings. Performance and portfolio variety. Metal *1 90 Optics AC power supply *2

Dimension A. Dimension B

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

Do not install and/or operate this safety product unless you have read and understand the safety information contained

INSTRUCTION and OPERATIONS MANUAL. for

Mechanical Spiral Sensor

A Member of the. Integrated Metering Technologies

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

ZB0050 / ZB0051 ZB0070 / ZB0071

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Safety interlock switch MKey

SELECON 80V DMX 1200W POWER SUPPLY OPERATION MANUAL

High-power Solid State Relays G3PH

Traffic Logix SafePace 450 Radar Speed Sign

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

LT-EL138 LED Flashlight

Conversion tables for Magne products

DALI 650mA LED Driver

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

EZ-LIGHT 2-Color Indicators for Use with Sensors

1000mA - 650mA Phase Dimmable LED Driver

10 S e r i e s PRESSURE SWITCH. features

650mA Phase Dimmable LED Driver

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

J 6 Se r i e s. Pressure and Vacuum switches. features

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

NEW GEN OWNER S MANUAL

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Installation Manual Model 3800/3810

Tissue Master. User Manual

This manual covers the following model:

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

A Member of the. Integrated Metering Technologies

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

English. Instruction and operation manual S 212. Dew point sensor

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Power Supply. Model PS-200

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

Bosch Smart Home. Door/Window Contact Instruction Manual

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation Power Management Unit Battery Cables and Battery Harness

Transcription:

Original Instructions Smile 11 RA/-B Smile 12 RF/-G Reset button ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety

Read and understand this User Manual Please read and understand this manual before using the products. Please consult your ABB JOKAB SAFETY representative if you have any questions or comments. WARRANTY ABB JOKAB SAFETY guarantees that the products are free from defects in materials and workmanship for a period of one (1) year (or other period if specified) from the date of sale by ABB JOKAB SAFETY. ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED USE. ABB JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. LIMITATIONS OF LIABILITY ABB JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER THE CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL ABB JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS ABB JOKAB SAFETY S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE ABB JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer s application or use of the product. At the customer s request, ABB JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Determine and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ABB JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA While every effort has been taken to ensure the accuracy of the information contained in this manual, ABB JOKAB SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and improvements without notice. Performance data given in this document are provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ABB JOKAB SAFETY S test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ABB JOKAB SAFETY Warranty and Limitations of Liability. 2TLC172097M0201, rev. C 2 www.abb.com/jokabsafety

Table of Contents 1 Introduction... 4 Purpose... 4 Target group... 4 Prerequisites... 4 Special notes... 4 2 Overview... 5 General description... 5 Safety instructions... 5 3 Electrical connections... 6 Smile 11 RA... 6 Smile 11 RB... 6 Smile 12 RF... 6 Smile 12 RG... 7 M12 connector... 7 4 Installation and maintenance... 8 Installation instructions... 8 Maintenance... 8 5 Operation... 9 LED indication... 9 6 Model overview... 10 Measurements... 10 7 Technical data... 11 2TLC172097M0201, rev. C 3 www.abb.com/jokabsafety

1 Introduction Purpose The purpose of these instructions is to describe the models Smile 11 RA/-B, and Smile 12 RF/-G of the Smile push button box, and provide the necessary information for installation and operation. The information applies to all models unless otherwise specified in the manual. Target group This document is intended for authorised installation personnel. Prerequisites It is assumed that the reader of this document has: Basic knowledge of ABB Jokab Safety products. Knowledge of machine safety. Special notes Pay attention to the following special notes in the document: Warning! Caution! NB! Risk of severe personal injury! Failure to carry out an instruction or procedure correctly, may result in injury to the operator or other personnel. Risk of damage to the equipment! Failure to carry out an instruction or procedure correctly, may result in damage to the equipment. Notes are used to provide important or explanatory information. 2TLC172097M0201, rev. C 4 www.abb.com/jokabsafety

2 Overview General description The Smile push button box is designed for use as a reset button in safety circuits. Smile 11 RA is a push button box with a normally open circuit for resetting and one input for connecting the LED in the push button. Smile 11 RB is a push button box designed for use together with a Pluto safety PLC. The Safety PLC Pluto has a feature called light button that is used to reduce the number of connections on Pluto. This feature means one connection can be used both as an input for resetting and an output for the LED. The feature requires a special connection for the reset button and its LED indicator, which Smile 11 RB provides. Smile 12 RF is a push button box designed for use together with Eden Dyn-Reset and Eden OSSD-Reset with 5 pin M12 connector. Smile 12 RG is a resetting push button box designed for use together with Eden OSSD-Reset with 8 pin M12 connector. Safety instructions Warning! Carefully read through the entire user manual before using the device. Products must be installed by a qualified electrician. Safety instructions, given standards and the machinery directive must be followed. Failure to follow the instructions, use contrary to these instructions as well as incorrect installation or handling of the product can affect the safety of personnel and equipment. Specific instructions for installation and prescribed use of the product given in the user manual must be carefully followed and relevant technical standards observed. Failure to comply with the instructions or standards, especially when tampering with and/or modifying the product, voids all liability. 2TLC172097M0201, rev. C 5 www.abb.com/jokabsafety

3 Electrical connections Smile 11 RA M12 connector 5 pin: 1) Brown 2) White 3) Blue 4) Black 5) Grey Smile 11 RB M12 connector 5 pin: 1) Brown 2) White 3) Blue 4) Black 5) Grey Smile 12 RF M12 connector 5 pin: 1) Brown 2) White 3) Blue 4) Black 5) Grey 2TLC172097M0201, rev. C 6 www.abb.com/jokabsafety

Smile 12 RG M12 connector 8-pin: 1 ) White 2 ) Brown 3 ) Green 4 ) Yellow 5 ) Pink 6 ) Blue 7 ) Red 8 ) Black M12 connector M12 5-pin male connector seen from the cable side M12 5-pin female connector seen from the cable side M12 8-pin male connector seen from the cable side M12 8-pin female connector seen from the cable side NB! A shielded cable is recommended between the Smile push button box and other electrical devices. Caution! All cable colours according to ABB Jokab Safety standard cables. 2TLC172097M0201, rev. C 7 www.abb.com/jokabsafety

4 Installation and maintenance Installation instructions 1. Secure the Smile push button box to the surface with two M5 screws. 2. Connect the M12 connector. Warning! The entire risk zone protected by the safety equipment must be possible to monitor from the position of the reset button. The safety circuit must never be broken without first ensuring that no one is in the risk zone. Warning! The reset button must not be placed so that it can be accessed from a dangerous position (for example, by stretching an arm around a corner or a finger through a safety net) Maintenance Warning! The safety functions and mechanism must be tested regularly, at least annually, to ensure that all the safety functions work properly. Warning! In the event of a functional stop or damage to the product contact your nearest ABB Jokab Safety representative/distributor. Do not try to repair the product yourself since it may cause permanent damage to the product and impair product safety with the risk of serious personal injury. Caution! ABB Jokab Safety assumes no responsibility for malfunctioning of the emergency stop if the installation and maintenance requirements described in this manual are not followed. These requirements are included in the product warranty. 2TLC172097M0201, rev. C 8 www.abb.com/jokabsafety

5 Operation LED indication LED indication is determined by the PLC program or other connected device e.g. Eden. NB! The table below describes the recommended use of the Smile push button box in a safety circuit. LED Indication Description LED in the button On On-Off (flashing) Off The safety circuit is not ready to be reset. The safety circuit is ready to be reset. The safety circuit is reset. 2TLC172097M0201, rev. C 9 www.abb.com/jokabsafety

6 Model overview Type Part number Description Smile 11 RA 2TLA030053R0000 Smile push button box with normally open resetting and one input for connecting the LED. Smile 11 RB 2TLA030053R0100 Smile push button box designed for use together with a Pluto safety PLC. Smile 12 RF Smile 12 RG 2TLA030053R2600 2TLA030053R2700 Smile push button box designed for use together with Eden Dyn-Reset and Eden- OSSD-Reset with 5 pin M12 connector. Smile push button box designed for use together with Eden-OSSD-Reset with 8 pin M12 connector. Measurements Smile 11 RA/-B Smile 12 RF/-G NB! All measurements in millimetres. 2TLC172097M0201, rev. C 10 www.abb.com/jokabsafety

7 Technical data Manufacturer Address ABB JOKAB SAFETY Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden Power supply LED operating voltage LED power consumption Push button box operating voltage Push button box power consumption Push button box nominal power 24 VDC (maximum 33 VDC) 20 ma at 24 VDC 30 ma at 33 VDC Min. 5 V Max. 35 V Min. 1 ma Max. 100 ma Max. 250 mw General Enclosure class Ambient temperature Relative humidity Enclosure material Connector material Connections Size Weight Colour Mechanical life Switching reliability IP65-25 +50 C 35-85 % (without icing or condensation) Polypropylene PP Au Smile 11 RA/-B: M12 5-pin male connector Smile 12 RF: M12 5-pin male and female connector Smile 12 RG: M12 8-pin male and female connector 84 x 40 x 36 (L x W x H) + 12 mm for M12 connector (L) ~ 60 g Enclosure: yellow Push button: blue 1,000,000 operations at 10 ma / 24 VDC 10 x 10-6 at 5 ma / 24 VDC 2TLC172097M0201, rev. C 11 www.abb.com/jokabsafety