THERMAL OVER CURRENT RELAY

Similar documents
INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA UNDERVOL TAGE RELAYS TYPES: IAV54E IAV55C IAV54F IAV55F

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

INSTRUCT IONS GEH-1 793J INSTANTANEOUS AUXILIARY RELAY TYPES HGA11A, C, H, J, K, P, S, T, V, W, X GENERAL ELECTRIC AUILIARV P A GENERALS ELECTRIC

B CW POWER RELAY

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

GEK 45484B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAY HFA151 TYPE. GE Protection and Control 205 Great Valley Parkway Malvern, PA

INSTRUCTIONS GEI-98305C UNDERVOLTAGE RELAY D-C. Type NGV18A GENERAL ELECTRIC

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

P. Sub 4 184A404. Sub 3 876A220

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

COM Overcurrent Relay

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

INSTRUCTION S GEK 7354J AUXILIARY VOLTAGE RELAY TYPE HAA16B, HAA16C GENERAL ELECTRIC

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

INSTRUCTIONS GEK G HIGH-SPEED DIFFERENTIAL RELAYS TYPES CFD22A AND CFD22B. GE Protection and Control

GENERAL ELECTRIC INSTRUCTIONS GEK- 2M42. Insert Rooklet GEH 1793 INSTANTANEOUS AUXILIARY RELAY TYPE HGA MODEL 12HGAI1E(-)A I NTRODUCT ION

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

41-747G. Figure 1: Type DGF Relay without case (Photo)

4.0 OPERATION Type ITH-T Relay

GENERAL ELECTRIC INSTRUCTIONS. GE I Supersedes GEI-28802E INSTANTANEOUS VOLTAGE RELAYS TYPES

INSTRUCTIONS HAA 15A/15B/15C/15D/15E/15F/15G/15H AUXILIARY CURRENT RELAYS. Iso9ooo. GE Power Management

INSTRUCTIONS SYNCHRONISM-CHECK RELAYS. GE Meter and Control. 205 Great Valley Parkway Malvern, PA Types IJS51A.

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

www. ElectricalPartManuals. com INSTRUCTIONS TYPE CO CONTACT MAKING AMMETER INSTALLATION OPERATION MAINTENANCE I.. L APPLICATION

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

INSTRUCTIONS GEI-10190L DC AUXILIARY RELAYS TYPE HGA17A TO F, H, M, R, S, T GENERAL ELECTRIC

INSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA GEK-49826D INSTANTANEOUS OVERCURRENT RELAYS TYPES:

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

UNION SERVICE SPECIFICATION NUMBER SU A

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

INSTRUCTIONS GEH-1789B GEH-1789A SUPERSEDES BALANCED-CURRENT RELAYS. Types. IJCSlB IJCSlC IJC53A. www. ElectricalPartManuals. com. GENERAL f) ELECTRIC

MAGNETIC MOTOR STARTERS

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

DIAC DIFC DSFC Digital Self Powered Overcurrent Protection

Installation Sheet January, 2016 Supersedes February, 2013

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

INSTANTANEOUS CURRENT RELAYS

A. Submit manufacturer's literature and technical data before starting work.

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

Instructions for De-Ion Air Circuit Breakers Types DM2R, DM2F

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Design Standard. Purpose: Design Standard:

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

INSTRUCTIONS TIME OVERCURRENT RELAY TYPE IAC 12IAC77S(-)A INTRODUCTION

Installation Sheet January, 2016 Supersedes June 2013

SECTION PANELBOARDS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

Type SOQ Negative Sequence Time Overcurrent Relay

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

CR193 Vacuum Limitamp* Contactors

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

INSTRUCTIONS. GE Protection and Control 205 Great Valley Parkway Malvern, PA GLK 34117G

Florham Park, NJ USA Call (ASCO) for sales or service

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

GE K D IN ST RU CT ION S INSTANTANEOUS AUXILIARY RELAY TYPE HGA111 GENERAL ELECTRIC

SL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

CX-Series. Circuit Breaker

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

SECTION MOTOR CONTROL

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Power systems Protection course

Industrial Control Transformers

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Control Transformers

Instructions for Replacing

www. ElectricalPartManuals. com outdoor oillnaken type GC aingle tank descrlpllve bullella page l 14.4 lev 100,380 and BOO mva 23 lev 280 mva

Motor Protection. Voltage Unbalance & Single-Phasing

INSTRUCT ION S GEK A. Supersedes GEK TIME OVERCURRENT RELAY TYPE IAC66S GENERAL ELECTRIC

Transcription:

INSTRUCTIONS THERMAL OVER CURRENT RELAY Type TMCllA GEI-28826A GENERAL. ELECTRIC www. ElectricalPartManuals. com com

GEI-28826A 2 Model Frequency 12TMC11A51A 50/60 12TMC11A52A 50/60 12TMC11A53A 50j60 12TMC11A54A 50/60 12TMC11A55A 50j60 12TMC11A56A 50/60 12TMCUA57A 50/60 12TMC11A58A 50/60 12TMC11A59A 50/60 12TMC11A60A 50,:0 12TMC11A61A 12TMC11A62A 25 12TMC11A63A 25 12TMC11A64A 12TMC11A65A 25 12TMC11A66A 25 12TMC11A67A 25 12TMC11A68A 25 12TMC11A69A 25 12TMC11A70A 25 25 Flg. I Type TMCIIA Relay Removed from Case TABLE "A" Full Load Amperes For 400C Rise Coil Rating Cont. Rated Motor Amperes Min. Max. 2.42 2.01 2.20 2.65 2.21 2.40 2.92 2.41 2.65 3.20 2.66 2.90 3.52 2.91 3.20 3.87 3.21 3.51 4.25 3.52 3.86 4.68 3.87 4.25 5.15 4.26 4.68 5.60 4.69 5.09 2.42 2.01 2.20 2.65 2.21 2.40 2.92 2.41 2.65 3.20 2.66 2.90 3.52 2.91 3.20 3.87 3.21 3.51 3.86 4.68 4.25 3.52 4.25 5.15 4.26 4.68 3.87 5.60 4.69 5.09 TABLE FOR SELECTING PROPER MODEL NO. OF TYPE TMCUA RELAY Instantaneous Unit Ampere Callbration Min. Max. 10 40-0 -a - g CG -i

THERMAL OVERCURRENT RELAY TYPe TMC 11A single pole thermal over current relay provides both instantaneous and thermal overload protection for motors with compensation for changes in relay ambient temperature. It consists of an induction thermal unit an instantaneous unit 1 and a universal seal-in urut and target coil (see Fig. 1). Both the thermal and instantaneous units have Independent normally open contacts with separate targets (the seal-in unit is energized by the closing of the thermal unit contacts). The thermal unit contacts are hand reset while the instantaneous unit contacts are self- reset. The two targets are reset by the same mechanism which resets the thermal unit contacts. The thermal unit consists of a current coil placed over a bi-metal helix that acts as the shortcircuited secondary of a transformer. The current heats the helix causing it to rotate in a direction to close the hand reset contacts. Tripping current is adjustable from 90 to 110 percent of coil rating. The contacts cannot be reset until the unit has cooled for a time. The instantaneous unit is the small hinge-type unit mounted on the right front side of the relay. It operates over a 4 to 1 range and has its calibration stamped on a scale mounted beside the adjustable pole piece. The relay case is suitable for either surface or semiflush panel mounting and an assortment ol hardware is provided for either mounting. The cover attaches to the case and also carries the reset mechanism. Each cover screw has provision for a sealing wire. The case has studs or screw connections at the bottom only for the external connections. The electrical connections between the relay units and the case studs are made through spring backed contact lingers mounted in stationary molded inner and outer blocks between which nests a removable connecting plug which completes the circuits. The outer block, attached to the case, has the studs for the.external connections, and the inner block has the terminals for the internal connections. The relay mechanism is mounted in a steel lramework called the cradle and is a complete unit 'With all leads being terminated at the inner block. 'This cradle is held firmly in the case with a latch at the top and the bottom and by a guide pin at the TYPE TMC INTRODUCTION back of the case. The case and cradle are so constructed that the relay cannot be inserted in the case upside down. The connecting plug, besides making the electrical connections between the respective blocks of the cradle and case, also locks the latch in place. The cover, which is fastened to the case by thumbscrews, holds the connecting plug 1n place. To d:;aw out the relay unit the cover is first removed, and the plug drawn out. Shorting bars are provided in the case to short the current transformer circuits. The latches are then released, and the relay unit can be easily drawn out. To replace the relay unit, the reverse order is followed. Ase.Parate testing plug can be inserted in place of the connecting plug to test the relaf in place on the panel either from its own source o current, or from other sources. Or, the relay unit can be drawn out and replaced by another which has been tested in the laboratory. The cover is provided with a mechanical interlock which prevents replacing the cover unless the connecting plug is in place. APPLICATION The Type TMC11A relay is not intended for use directly in primary circuits. It should always be used with current transformers. It is selfprotecting on primary short-circuits because the CT will saturate before excessive secondary currents are reached. For standard 40 C continuous-rated motors (which have 115 percent service factor), the relay should be selected so that the full load current of the motor falls between the minimum and maximum values of full load amperes on Table "A". For 50 C or 55 C continuous-rated motors (which do not have 115 percent service factor), multiply the motor full-load amperes by 0.9 and use this value to select the relay. For 0.8 power factor synchronous motors with constant field excitation and driving d-e generators rated 150 percent load for two hours, obtain the motor armature current at 150 percent load on the generator from the motor data sheet, multiply by 0.9, and use the value to select the relay. If Thea inltrvdiona do not purport to ccwer oil detau or.,oriaf;- in equipment nor to,_.,ide for..,.,.,. pouible coftlingency to be met in ioll wifft inlifallotion, opetafioll or ntai- Should fvrl#te, informatioll be derired or lhoulcl particular em. winch ore not ccwwed IUificienlly for the purdto-' J141FP0a1, the maher mould be referred to the G.-a/ Electric COIIIfXI'IY. 3

GEI-28826 A the data is not available, take the motor full load armature current, multiply by 1.16, and use this value to select the relay. (The motor current at 150 percent load will be about 133 percent of full load value. Division of 133 percent by 115 percent gives 1.16). For 0.8 power factor synchronous motors with constant field excitation and driving d-e generators rated 125 percent load for two hours, obtain the motor armature current at 125 percent load on the generator from the motor data sheet, multiply by 0.9, and use this value to select the relay. If the data is not available, select a relay the same as for standard 40 C continuous -rated motors (the motor current at 125 percent load will be about 115 percent of the full load value). For intermittent rated motors, or for motors designed for use in higher temperature or altitudes, relays should be s e l e c t e d in accordance with the characteristics of the motor and the application. Table "A " gives the permissible application range in full-load amperes for 40 C rise motors with 115 percent service factor and the corresponding rated coil amperes. The coil rating is the approximate value at which the relay will ultimately trip in a 40 C ambient, with the relay calibration set at 100 percent, and is equal to 110 percent of the maximum full-load amperes. If the motor full-load amperes are equal to the minimum value in the application range, then the nominal trip value of the relay will be approximately 120 percent of full-load. If the full-load amperes are equal to the maximum value, the nominal trip value will be approximately 110 percent of full-load. The relay can be adjusted from 90 percent to 110 percent of these values. For 50 C and 55 C rise motors, application of the 0.9 multiplier essentially reduces the nominal trip point another 10 percent. RATINGS Type TMC11Arelay is available for 25and 50/ 60 cycles in current ratings from 2.42 to 3.52 amperes with 10 j40 ampere instantaneous unit and from 3.87 to 5.60 amperes with 20j86ampere instantaneous unit. See Table "A". The current-closing rating of the contacts is 30 amperes for voltages not exceeding 250 volts. The current-carrying ratings are affected by the selection of the tap on the seal-in unit coil as indicated in the following table: Amperes AC or DC,unction 2-Amp Tap 0.2 Amp Tap rt'ripping Duty 30 5!Carry Continuously 4 0.8 The 2-ampere tap has a d-e resistance of 0.13 ohms and a 60 cycle impedance of 0.53 ohms while the 0.2-ampere tap has a 7 ohm d-e resistance and 52 ohm 60 cycles impedance. The tap setting used on the seal-in element is determined by the currelit drawn by the trip coil. The 0.2-ampere tap is for use with trip coils that operate on currents ranging from 0.2 up to 2.0 amperes at the minimum control voltage. If this tap is used with trip coils requiring more than 2 amperes, there is a possibility that the 7-ohm resistance will reduce the current to so low a value that the breaker will not be tripped.. The 2-ampere tap should be used with trip coils that take 2 amperes or more at minimum control voltag e..z provided the tripping current does not exceed 3u amperes at the maximum. control voltage. If the tripping current exceeds 30 amperes an aux"" Uiary relay should be used, the connections being such that the tripping current does not pass through the contacts or the target and seal-in coil of the protective relay. INSTANTANEOUS UNIT BURDENS Burden data on the instantaneous unit coils are given in the following table: Volt Imp. Coil Freq. Amp Amp Ohms PF 1Q-40 60 5 0.83 0.033 0.95 50 5 0.80 0.032 0.95 25 5 0.65 0.027 0.98 20-80 60 5 0.21 0.008 0.95 50 5 0.20 0.008 0.95 25 THERMAL UNIT 5 0.15 0.007 0.98 At rated current the burden of the thermal unit is approximately 13.5 volt-amperes and 12 watts for 25 and60 cycle operation or approximately 12.5 volt-amperes and 11 watts for 50 cycle operation. The volt-ampere burden of the thermal unit at 5 amperes is approximately equal to K divided by the square of the current rating, where K is 325 for 25 and 60 cycles and 305 for 50 cycles. RECEIVING, HANDLING AND STORAGE These relays, when not included as a part of a control panel will be shipped in cartons designed to protect them against damage. Immediately upon receipt of a relay, examine it for any damage sus- 4 tained in transit. If injury or damage resulting from rough handling is evident, file a damage claim at once with the transportation company and promptly notify the nearest General Electric Ap-

" f I "" 0...._ -;;;- r.t),... 0 SEAL-IN UNIT RESET LEVER COMPENSATING_... BIMETAL RESET ROD -- STA TION ARY CONTA CT MO VABLE-- ---- CONTACT BRUSH Fig. 2 SC ALE PL ATE ADJUSTABLE POLE PIECE '---... OPERATING COIL.--- ADJUSTMENT LOCKING SC REW '----'=--t-- -'DJUSTI NG SCREW Type TMCIIA With Nameplate Removed To Show Adjusting Plate Of Thermal Unit RETAINING PL ATE BIMETAL HELIX MOVA BL E CONTA CT BRUSH COMPENSATING BIMETAL STATIONARY CONTACT BRUS H CONTACT TERMINALS Fig. 3 STEEL CORE ADJUSTMENT LOCKING SCREW ADJUSTING SCREW Thermal Unit with Current Coil and Reset Rod Removed GEI-28826A www. ElectricalPartManuals. com com 5

GEI-28826A paratus Sales Office. Reasonable car e should be exercised in unpacking the relay in order that none of the parts are injured or the adjustments disturbed. LOCATION The location should be clean and dry, free from dust and excessive vibration, and well lighted to facilitate inspection and testing. MOUNTING The relay should be mounted on a vertical surface. The outline and panel diagram is shown The relays are tested at 100 percent calibration. The relay when hot, is tested to hold (nonoperative) at 90 percent of its coil rating and trip at 100 percent. Thus, an individual relay may vary as much as 10 percent in its calibration; i, e., an individual relay may trip at 90 percent of its coil rating with the adjustment screw set at 100 percent. The instantaneous unit should be set at about 1.6 times the maximum (110 percent normal voltage) locked rotor current of the motor. Since the required setting would seldom be less than 5 times or more than 12 times full load current, the relays rated from 2.42 to 3.52 amperes are provided with 10/40 ampere units and the 3.87 to 5.60 ampere relays are provided with 20/80 ampere units. Example: Standard 40 C motor, full voltage started, 60 cycle, full load current 3.92 amperes (CT sec.) maximum locked rotor current 500 percent. Use Model 12TMC11A58A rated 4.68 am- The relay has been adjusted at the factory and it is advisable not to distrub the adjustments. It is most important that the bimetal helix and the compensatin bimetal should never be tampered with at any hme. Upon leaving the factory, the relay is set for the 100 percent calibration. If it is desired to adjust the relay to trip at a slightly higher or lower value of current, loosen the adjustment locking screw (see Fig. 3.) Then the adjusting screw can be turned to provide the desired adjustment. Be sure to tighten the adjustment locking screw. To substitute a new current coil in the thermal unit, the procedure should be as follows: 6 INSTALLATION If the relays are not to be installed immediately, they should be stored in their original cartons in a place that is free from moisture, dust and metallic chips. Foreign matter collected on the outside of the case may find its way inside when the cover is removed and cause trouble in the operation of the relay. infig, 7. OPERATION MAINTENANCE CONNECTIONS The internal connections for Type TMCllA relay are shown in Fig, 4. A typical wiring diagram is shown in Fig, 5. One of the mounting studs or screws should be permanently grounded by a conductor not less than No. 12 B & S gage copper wire or its equivalent. peres 50/60 cycles thermal unit, 20/80 amperes instantaneous unit. The thermal unit has a nominal trip point of 4.68 amperes adjustable from 90 percent to 110 percent or 4,21 to 5.15 amperes. This corresponds to 108 percent to 131 percent of fullload allowing operation at 115 percent continuously if desired. If this were a 55 C motor, the current value to be used for selecting the relay would be 3.92 x.9 or 3.53 amperes. Use model 12TMC11A57A rated 4.25 amperes. The nominal trip point is adjustable from 98 percent to 119 percent of full load allowing operation at 100 percent continuously. For both motors, the instantaneous unit setting would be 3.92 x 5 x 1.6 x 1.1 = 35 amperes. The average time-current characteristic curve for this relay is shown in Fig. 6. 1. Remove con leads from terminals 5 & 6. 2. Loosen the three mounting screws and romove the retainj.dg plate (see Fig. 2). 3. Lift out the present con and substitute the replacement taking care that the con ls mounted with the two locating pins on the lower side. 4. Replace the retaining plate so that lt rests squarely against the end of the core. 5. Tighten the three mounting screws. 6. Connect con leads to terminals 5 & 6. CONTACT CLEANING For cleaning fine silver contacts, a flexible burnishing tool should be used. This consists of a.

LL. Fig. ij...... UN I/' SEAL-IN a.. 2... 500...J 0 u 0 1- I U N N S I T.T qqqq 2 4 6 8 80 70 0 60 0 :400 1- z: u a.. 30 0 200 100 10 :: SHORT FINGER Internal Connections for Type TMCIIA Relay i\ \ \ \ \ \ 60 i\ \ v '( 1\ \ \.. v Fig. 6 \ \ \ CYCLES \ 50 CYCLES "\ ' 1'. " r--. 1"..., "t A-C BUS -...; Fig. 5 LEGEND 49 TYPE TMC RELAY Sl SEAL IN UNIT 50 INSTANTANEOUS UNIT 52 CIRCUIT BREAKER TC TRIP COIL GEI-28826A a AUXILIARY CONTACT, CLOSEJ WHEN BREAKER IS CLOSED Typical External Connections for Type lmcija Relay THERMAL OVERCURRENT RELAY TYPE TMCIIA(-)A AVERAGE TIME-CURRENT CURVES BASED ON 40 DEGREES C AMBIENT./ 25 CYCLES 20 30 40 50 60 70 80 90 100 200 300 400 500 600 800 1000 SECOND TO TRIP Average Time-Current Character istic Curve for Type TMCIIA Relay 7

12-52 GEI-28826A flexible strip of metal with an etched roughened surface, resembling iu effect a superfine file. The polishing action is so delicate that no scratches are left, yet corroded material will b e removed rapidly and thoroughly. The flexibility of the tool insures the cleaning of the actual points of contact. Sometimes an ordinary file cannot reach the actual points of contact because of some obstruction from some other part of the relay. Fine silver contacts should not be cleaned with It is recommended that sufficient quantities of renewal parts be carried in stock to enable the prompt replacement of any that are worn, broken, or damaged. 6 57 9 0000 00000 2 4 6 B 10 NUMBE NG OF STUDS (FRONT VEW) RENEWAL PARTS - 1--- - PANEL DRILLING FOR SEMI-FLUSH MOUNTING (FRONT VIEW) Fig. 7 CASE - knives, files or abrasive paper or cloth. Knives or files may leave scratches which increase arcing and deterioration of the contacts. Abrasive paper or cloth may leave minute particles of insulating abrasive material in the contacts and thus prevent closing. The burnishing tool described above can be obtained from the factory. When ordering renewal parts, address the nearest Sales Office of the General Electric Company t specify quantity required. name of. wanted, ana give complete nameplate data, inclu serial number. If possible, give the General Electric Company requisition number on which the relay was furnished. l a> v _J_l r :I PANEL v OUTLINE ii-18 STUD VIEW,SHOWII'IG ASSEMBLY OF HARDWARE FOR SURFACE NTG. ON STEEL PANELS Outline and Panel Drilling for Type TMCIIA Relay PANEL DRILLING FOR SURFACE MOUNTING (FRONT. W) GENERAL ELECTRIC COMPANY, SCHENECTADY, N. Y. SupOf'sodes GEI-28826..... \