SMX-F. Self-priming magnetic drive pumps. Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation CFRETFE

Similar documents
Main material CFRETFE IWAKI SELF-PRIMING MAGNETIC DRIVE PUMPS SMX-F PATENT JAPAN / U.S.A. / EU / CHINA / TAIWAN

Main material CFRETFE IWAKI SELF-PRIMING MAGNETIC DRIVE PUMPS SMX-F PATENT JAPAN / U.S.A. / EU / CHINA / TAIWAN

MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series.

SMX. Self-priming magnetic drive pumps Magnetic drive pumps with an excellent balance of features and performance GFRPP

Max. flow capacity of 5,000 L/min and max. discharge head of 98m. The world s largest class fluoroplastic magnetic drive pump.

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

IWAKI MAGNETIC DRIVE PUMPS MX-F

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

Main material GFRPP IWAKI MAGNETIC DRIVE PUMPS

PDF-A Self-priming magnetic drive pumps. SMX series

Iwaki Electromagnetic Metering Pump EWN-R (Chlorine Dioxide type)

IWAKI CHEMICAL GEAR PUMPS

METALLIC CENTRIFUGAL MAGNETIC DRIVE PUMPS MP M MMP MTFO

IWAKI Gas-Liquid Transfer Pump APN-30/-60 GD3-W Instruction Manual. Read this manual before use of product

IWAKI Magnet Gear Pump MDG-M4 (built-in type) Instruction Manual

Magnetic drive pumps MX series

IWAKI Magnet Gear Pump MDG-M4 Instruction Manual

IWAKI CHEMICAL GEAR PUMPS

IWAKI PNEUMATIC-DRIVEN BELLOWS PUMP CFD-8T-B TYPE Instruction Manual. Read this manual before use of product

Iwaki Photoresist Dispensing Pump PDS-105 RA/RB

IWAKI Gas-Liquid Transfer Pump APN-05/-10/-20/-30/-60-W (built-in type) Instruction Manual. Read this manual before use of product

IWAKI Gas-Liquid Transfer Pump APN-085-W Instruction Manual. Read this manual before use of product

IWAKI Magnetic Drive Pump MX-F100 Instruction Manual. Read this manual before use of product

MDT Series Instruction Manual

IWAKI Air Pump BAN-0510/-0505 Instruction Manual. Read this manual before use of product

IWAKI Air Pump APN-085-D3 Instruction Manual. Read this manual before use of product

MXM. Magnetic drive pumps Magnetic drive pumps with an excellent balance of features and performance. s e r i e s

IWAKI Electromagnetic Metering Pump ES-B/C Type Instruction Manual. Read this manual before use of product

IWAKI PNEUMATIC DRIVE BELLOWS PUMPS

Iwaki Direct Drive Pump RD-40

Iwaki Direct Drive Pump RD Series

IWAKI PNEUMATIC-DRIVEN BELLOWS PUMP CFD-8T-B TYPE Instruction Manual. Read this manual before use of product

PDF-A Magnetic drive pumps. MDM series

IWAKI Hicera Pump V series Instruction Manual. Read this manual before use of product

MX-F. Magnetic drive pumps. Chemically resistant magnetic drive pumps which can tolerate abnormal operation. s e r i e s

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

IWAKI Metering Pump LK-A, B, C Models Instruction Manual

IWAKI MAGNETIC DRIVE PUMPS MDW. Patent JAPAN / U.S.A. / EU / CHINA / TAIWAN

SP SERIES SELF-PRIMING MAG DRIVE

DOUBLE OCTOMILL TM PRODUCT RANGE

You ll find many Tsubaki products being

Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9

IWAKI Metering Pump LK-F Series Instruction Manual

HOW TO SEND E-INVOICES TO CARGOTEC

Process Magnetic Drive Pump. Global Technical Information

Guide Ball Bushing NEW

Knife gate valve JTV. Data is only for informational purpose. All specifications are subject to change without notice issue 11

NEW. PLASTIC MODULAR CHAIN WT0705-W Plastic Top Chain

Magnetic drive pumps MX series

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

BP Statistical Review of World Energy June 2017

Stafsjö s ATEX solutions for category 1 D (Zone 20)

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

Information Technology and Economic Development: An Introduction to the Research Issues

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

MTC. Mold Temperature Control. Consilience Technology

Spherical Roller Bearings

self-priming thermoplastics magnetic drive pumps

CAT.ES70-22 A. Series VC. Direct Operated 2 Port Solenoid Valve for Heated Water. Series VCB

Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects

Bearings for the Cement and Ready-Mix Concrete Industries

series VALVELESS SELF-PRIMING MAGNETIC PUMP

Single-acting pneumatic cylinder type ECS

MICRO DIAPHRAGM GAS PUMPS NMP 830, NMP 850 and NMP

Sealless Magnetic Coupled Multistage Centrifugal Pumps with Priming Stage Type HZSM / HZSMB / HZSMR / HZSMA / HZSMAR

IWAKI Pneumatic Drive Bellows Pump FA Instruction Manual

PREVIEW. Fieldbus System for Distributed I/O NEW PRODUCTS

Installation instructions

FEDERAL RESERVE statistical release

Options for the Ball Screw QZ Lubricator Wiper Ring W

replacement parts 6.1 General 6.2 Ordering

STEEL INDUSTRY ELECTRIC ARC FURNACES REFRACTORY CONCEPT SOLUTIONS

STEEL INDUSTRY STEEL LADLES REFRACTORY CONCEPT SOLUTIONS

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

NI PS-15/16/17 Side Mount Brackets

HELICOPTERS Service. Helicopter Maintenance Upgrades

Knife gate valve MP. Data is only for informational purpose. All specifications are subject to change without notice issue 5

CRES. RoD Actuator. Low-cost and handy actuator Dustproof and waterproof design compliant with IP55 standard Compliant with the RoHS Directives

N 2400 SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

FG Series, 230V ac Toroidal Single Primary Transformers

PSF 250, PSF 305, PSF 405, PSF 505, PSF 405 RS3 PSF 410W, PSF 510W, PSF 410W RS3, PSF 510W RS3,

Knife gate valve WB. Data is only for informational purpose. All specifications are subject to change without notice issue 12

Tapflo - your reliable pumpchoice

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

Roll Up WireFree IR. Installation instructions

DIAPHRAGM LIQUID PUMPS

Infographics on Electromobility (January 2019)

CTV VERTICAL PUMPS. All about your flow. edition 2017 rev 1

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS TO ATEX

PARTS MANUAL EMP 285ic 1ph & EMP 285ic 3ph

1. General company data

Wear Resistant Tubing

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

BOLL Automatic Filter TYPE The Compact Design Two-Chamber Filter. BOLL & KIRCH Filterbau GmbH

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

Transcription:

SMX-F series Self-priming magnetic drive pumps Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation Self-priming magnetic drive pumps Main material CFRETFE The SMX-F is a horizontal self-priming magnetic drive pump made from fluororesin. Our original self-radiation structure enhances resistance to abnormal operations. Patent JAPAN / U.S.A. / EU / CHINA / TAIWAN

Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation The SMX-F is a horizontal self-priming magnetic drive pump made from fluororesin. Our original self-radiation structure enhances resistance to dry running, cavitation, and closed-discharge operation. In addition, the use of standard motors extends the range of application. 3 SMX-F441 SMX-F221 1

SMX-F series Excellent corrosion resistance The casings, impeller assembly and magnet capsule are made of fluororesin(cfretfe). Other wet-end parts are made of highly corrosion resistant materials such as carbon, ceramic and the like. The pumps can handle almost type of chemicals including strong acid/alkali. Expanded versatility The SMX-F has a modular structure to handle liquids with high specific gravities. Use of standard motors extends the range of liquid application. Easy maintenance The pump wet end can be removed from the motor as a complete assembly without dismantling, thanks to an additional rear casing support. The pump wet end comprises the minimum number of parts for easy maintenance. Enhanced durability under abnormal operation Our original self-radiation structure (Patented) efficiently disperses bearing friction heat to protect the pump under abnormal operating conditions. In addition, our noncontact structure prevents contact between rear thrust face and bearing, to eliminate heat buildup during dry running. Spindle Rear thrust Bearing Heat-Dispersion hales Rear casing support Magnet capsule Impeller Rear casing Fast self-priming The SMX-F requires no external self-priming chambers or valves. The gas-liquid separation design ensures fast selfpriming. An exceptional self-priming duration of up to 4m in only 9 seconds is now possible. Rear casing support The pump wet end is easily removed from the motor by removal of 4 mounting bolts on the motor bracket. The rear casing support performs easy maintenance and draining of any residual liquid at other place. Examples of application Pumping up from underground tank Underground tank at chemical plant. Underground tank or pit of waste plant. Pumping up and out from top of tank and tanker truck Transferring etching and plating chemical from chemical bath. Sucking up chemical from truck. Pumping up from top of tank. Transferring chemical from tank to tank Transferring from main tank to daily tank. Refilling chemical from drum to tank. 2

Reliability and performance are enhanced by our unique design 6 Plate 2 Rear case 4 Volute spacer Impeller 16 Lock pin 7 Magnet capsule 1 Spindle 3 Rear casing 13 Rear thrust ring 12 Rear thrust 1 Front case 8 O ring 9 Gasket 11 Liner ring 1 Mouth ring 8 O ring Bearing Wet-end materials 1 2 3 4 6 7 8 9 1 11 12 13 Name of part Front case Rear case Rear casing Volute spacer Impeller Plate Magnet capsule O ring Gasket Spindle Liner ring Bearing Model SMX-F22,44 Rear thrust Note:2 Rear thrust ring 1 Mouth ring 16 Lock pin Note:1 Note1: type only Note2: Exclusive for SMX-F22RF, 44RF CF RF CFRETFE FKM/EPDM High purity alumina ceramic CFRETFE High purity alumina ceramic - High purity alumina ceramic High density carbon PTFE (With filler) PTFE (With filler) CFRETFE KK SiC SiC - SiC 3

SMX-F series Principles of Self-Priming: 1 2 F A E D 3 C B 1 2 Prime the pump with liquid. On starting, the pump will suck both gas and liquid into its inlet. This mixture moves through front case A to the front casing, where it is agitated by the impeller. The mixture is discharged through pump chamber B to rear case C, where gas and liquid separation then occurs. Gas is bled from the discharge port D while some liquid is retained. Liquid in the rear case C is fed back through circulation hole E to the front casing, where it is again mixed with entrained gas by the impeller. This recirculation & bleeding process continues until gas from the suction side F is completely expelled. 3 Once all gas is expelled, normal centrifugal pump operation is resumed. Sufficient liquid remains in the casing for subsequent self-priming once the pump is stopped. 4

Specifications Model Connection Suction X Discharge (mm) Impeller Cycle (Hz) Min. capacity (L/min) Temperature range of handled liquid: to 8 C (The self-priming height limit decreases at high temperatures.) Standard specification (L/min-m) Max. capacity (L/min) Motor (kw 2p) Resisting pressure limit (MPa) SMX-F22 2 X 2 V 8-7. 9.37.28 SMX-F221 SMX-F222 SMX-F441 SMX-F442 2 3 T 1-12. 1 2 X 2.7.28 V 8-7. 12 1 2 X 2 T 1-12. 1 1..28 17. 4 X 4 T 1-11.8 19.7.33 1. 4 X 4 T 1-11.8 28 1..33 19 X 4 V 2-16. 23 1. X 4 X 4 T 2-16. 44 2.2 V 2 2-16. 41 2.2.4 T 2-16. 44 4. V 2-16. 41 4. Mass Less motor (kg) 28 36 Pump identification SMX-F 22 CF V V C Series symbol SMX-F : CFRETFE type Pump size 22 : 2(Suction) X 2(Discharge) 44 : 4(Suction) X 4(Discharge) 4 : (Suction) X 4(Discharge) Material of O-ring V : FKM E : EPDM Motor specifications E : IEC motor Motor output :.37kW 1 :.7kW 2 : 1.kW 3 : 2.2kW : 4.kW Materials of Bearing/Spindle/Liner ring CF : High density carbon/high purity alumina ceramic/high purity alumina ceramic RF : PTFE (with filler)/high purity alumina ceramic/high purity alumina ceramic KK : SiC/SiC/SiC Impeller T : Hz V : Hz Note: All combination of impeller and motor size are not available. Please contact Iwaki for detail. Dimensions in mm SMX-F22, 221, 222 -F441, 442 -F42, 43 OUT i e a b OUT i e a b IN d c g f H IN 1 11 d c g f H 3.2 13 2 L h 36 28 26 (26) L h 36 23 (26) Model H L a b c d e f g h i SMX-F22 (329) (39) ø12 ø2 ø12 ø2 (162) (74) 2 (24) (38) SMX-F221 (329) (3) ø12 ø2 ø12 ø2 (162) (74) 2 (24) (32) SMX-F222 (329) (67) ø12 ø2 ø12 ø2 (162) (74) 2 (24) (332) SMX-F441 (364) (99) ø ø4 ø ø4 (188) (93) 271 (28) (366) SMX-F442 (364) (62) ø ø4 ø ø4 (188) (93) 271 (28) (378) 2 (389) (663) ø ø4 ø1 ø (24) (1) 289 (31) (388) 3 (389) (663) ø ø4 ø1 ø (24) (1) 289 (31) (388) (389) (731) ø ø4 ø1 ø (24) (1) 289 (31) (48) Note: The dimensions may differ with the type of motor installed.

SMX-F series Performance curves Head (m) 3 2 2 1 1 SMX-F22 Sp H Q SMX-F22 V Hz SMX-F22V SMX-F221V 1 1 2 Capacity (L/min) 3 2 2 SMX-F44 SMX-F22 T SMX-F22 V SMX-F22 T Sp SMX-F44 T H Q Hz.8.6.4.2 1.6 1.2.8.4 SP (kw) SP (kw) Head (m) 1 SMX-F44 T 1 SMX-F441T SMX-F442T 1 2 3 4 Capacity (L/min) 4 3 Sp Hz 4. 3. 3 2 T V 2. 1. SP (kw) Head (m) 2 1 H Q SMX-42V T 1 V SMX-43V, 4V 1 2 3 4 6 Capacity (L/min) 6

Precautions on the selection of pumps Self-priming considerations 1.The performance curves on this catalogue are based on the operation with 2ºC clean water in flooded suction. Keep a margin (3% of the curves) when selecting the pump. 2.The magnetic pump cannot run continuously with a closed-discharge. Be sure to observe the minimum flow rate. The minimum flow rate SMX-F22 : 1L/min SMX-F44 : 1L/min : 2L/min 3.Select a pump model according to liquid specific gravity. Keep a margin (% or more) for motor output. Pump shaft power Sp x Specific gravity x 1. or more (margin) Motor output 1.The diameter of the piping on the suction side should be the same as that of the pumps inlet port (22 : 2mm, 44 : 4mm, 4 : mm), and the length of the piping should be limited to less than 4.7m. A larger pipe diameter or longer piping could adversely affect the self-priming performance, or could even hinder the self-priming process itself. 2.In cases where the liquid level fluctuates, take the height from the lowest liquid level as the maximum self-priming height. 3.Always perform priming before first operation, and start the pump only after the pump chamber has been filled with the handled liquid. 4.7m 4.m 4.The self-priming performance (4m in 9 seconds) is based on the operation with 2ºC clean water on the right piping condition. Self-priming performance varies with liquid temperature, characteristics and piping conditions. Obtain a rough guide of the highest possible self-priming height at each liquid specific gravity by the following formula. The highest possible self-priming height[m] = Self-priming height with clean[m] / Liquid specific gravity 4.To prevent early deterioration, avoid frequent start/stop of the pump..if a foot valve is installed on the suction pipe. pipe resistance may increase so that the pump cannot suck liquid enough. Dia. of suction pipe SMX-F22 : 2mm SMX-F44 : 4mm : mm Optional accessories Iwaki dry running protector DR series Model DR is electric current sensing type dry running protector. It detects the decreased load current (lower limit) to stop the pump when it runs dry or runs with air sucking in. It can detect over-load, too. DR-2 Current figure to be set is indicated on LCD. Both top/bottom figures can be set. Top:Over-load Bottom:Dry running, air sucking-in operation, operation with suction side closed Built-in current transformer DIN rail mounting It is unable to use DR when inverter is employed in the system. Specification Model Motor power Applied motor Power control V Power Input Detective current Current transformar(ct) Outer dimension DR-2 38 to 44V three phase.7 to 1kW 1 to 24V single phase 2 to 24V ±1%single phase 3.W. to 32.A Built-in D8 X W13 X H122 /6Hz www.iwakipumps.jp EUROPE / U.S.A. European office: IWAKI Europe GmbH Holland : IWAKI Europe (NL Branch) Austria : IWAKI (Austria) GmbH Belgium : IWAKI Belgium N.V. Denmark : IWAKI Nordic A/S Finland : IWAKI Suomi Oy France : IWAKI France S.A. Germany : IWAKI Europe GmbH Italy : IWAKI Italia S.R.L. Norway : IWAKI Norge AS Spain : IWAKI Iberica Pumps, S.A. Sweden : IWAKI Sverige AB Switzerland : IWAKI (Schweiz) AG U.K. : IWAKI Pumps (UK) Ltd. U.S.A. : IWAKI America Inc. TEL: (49)2 924 TEL: (31)47 293 16 TEL: (41)26 674 93 TEL: (32)13 67 2 TEL: (4)48 24 234 TEL: (38)9 27481 TEL: (33)1 69 63 33 7 TEL: (49)2 924 TEL: (39)2 99 3931 TEL: (47)66 81 16 6 TEL: (34)943 633 TEL: (46)8 11 729 TEL: (41)26 674 93 TEL: (44)1743 231363 TEL: (1)8 429 4 FAX: 2 924 48 FAX: 47 292 332 FAX: 26 674 93 2 FAX: 13 67 2 3 FAX: 48 24 2346 FAX: 9 274271 FAX: 1 64 49 92 73 FAX: 2 924 FAX: 2 99 42888 FAX: 66 81 16 61 FAX: 943 628799 FAX: 8 11 72922 FAX: 26 674 93 2 FAX: 1743 3667 FAX: 8 429 1386 IWAKI CO.,LTD. 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 11-88 Japan TEL : (81)3 324 293 FAX : 3 322 8892 ASIA / OCEANIA Australia : IWAKI Pumps Australia Pty Ltd. China Hong Kong: IWAKI Pumps Co., Ltd. Shanghai : IWAKI Pumps (Shanghai) Co., Ltd. Guangzhou: GFTZ IWAKI Engineering & Trading Co., Ltd. Beijing : GFTZ Iwaki Engineering & Trading Co., Ltd. (Beijing office) Korea : IWAKI Korea Co.,Ltd. Malaysia : IWAKIm Sdn. Bhd. Singapore Indonesia Taiwan Thailand Vietnam : IWAKI Singapore Pte Ltd. : IWAKI Singapore (Indonesia Branch) : IWAKI Pumps Taiwan Co., Ltd. : IWAKI (Thailand) Co.,Ltd. : IWAKI Pumps Vietnam Co., Ltd. TEL: (61)2 9899 2411 TEL: (82)267 1168 TEL: (86)21 6272 72 TEL: (86)2 843 63 TEL: (86)1 6442 7713 TEL: (82)2 263 48 TEL: (6)3 783 887 TEL: (6)6316 228 TEL: (62)21 69666 TEL: (886)2 8227 69 TEL: (66)2 322 2471 TEL: (84)613 93346 ( )Country codes FAX : 2 9899 2421 FAX: 267 1 FAX: 21 6272 6929 FAX: 2 843 9181 FAX: 1 6442 7712 FAX: 2 263 481 FAX: 3 783 48 FAX: 6316 3221 FAX: 21 696612 FAX: 2 8227 6818 FAX: 2 322 2477 FAX: 613 933399 Caution for safety use: Before use of pump, read instruction manual carefully to use the product correctly. Actual pumps may differ from the photos. Specifications and dimensions are subject to change without prior notice. For further details please contact us. Legal attention related to export. Our products and/or parts of products fall in the category of goods contained in control list of international regime for export control. Please be reminded that export license could be required when products are exported due to export control regulations of countries. CAT-E7-2 21.9.2.KPN