Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display Units displayed Switching logic Ambient temperature min./max. Medium temperature min./max. Medium Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) CE declaration of conformity culus RoHS Conforms with REACH Free of substances that impair surface wetting in the coating process Relative pressure LCD display, 4 digits Color setting: green or red bar, psi, kpa, MPa, inhg NO/NC (adjustable) + C / +6 C + C / +6 C Compressed air (max. 4 μm) 4 mg/m³ 3 g 5 g ( - 5 Hz) Precision (% of full scale value) ±.5% in temperature range of - 3 C ± 2 % including temperature drift Repeatability (% of full scale value) ±,2 % Switching time < 5 ms Switching point adjustable -% Resetting point adjustable -% Hysteresis adjustable Delayed hysteresis adjustable Window function adjustable DC operating voltage min./max. 7 V DC - 3 V DC Analog output - V DC, 4-2 ma Quiescent current consumption <4 ma Analog output linearity <±.5% of the final value Maximum load (analog current output) 6 Ω Short circuit resistance Max. 6 ohms (current output) Min. 3K ohms (voltage output) Mounting types Directly on hat rail and wall mounting For panel installation using mounting kit via double nipple Protection class IP65 IP67 with connections assembled Weight.4 kg Materials: Housing Seals Blanking plug Electr. connection Polycarbonate Acrylonitrile butadiene rubber Polyoxymethylene Aluminum, black anodized Technical Remarks Alternative pressure connection (G/4) on the rear side (closed with plug) Display color selectable, red or green The IO-Link device description (IODD) for the PE5 pressure sensor is available for download in the Media Centre. Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
2 Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin Operating pressure range min./max. [bar] Protection against overpressure Analog - / 5 bar - Output signal digital Compressed air connection Fig. Part No. Internal thread, G /4 Fig. R4276 push-in fitting, Ø 4 Fig. 2 R4276 Internal thread, G /4 Fig. R42769 - / 5 bar output, - V DC, 4-2 ma output, PNP, push-in fitting, Ø 4 Fig. 2 R42768 - / - / - / - / / 6 5 bar 5 bar - output, - V DC, 4-2 ma output, PNP, x IO-Link output, PNP, x IO-Link output, PNP, Internal thread, G /4 Fig. R42775 push-in fitting, Ø 4 Fig. 2 R42774 Internal thread, G /4 Fig. R42763 push-in fitting, Ø 4 Fig. 2 R42762 Internal thread, G /4 Fig. R4277 push-in fitting, Ø 4 Fig. 2 R4277 / 6 5 bar - / 5 bar output, - V DC, 4-2 ma output, PNP, x IO-Link output, PNP, x IO-Link output, PNP, Internal thread, G /4 Fig. R42765 push-in fitting, Ø 4 Fig. 2 R42764 Internal thread, G /4 Fig. R42777 push-in fitting, Ø 4 Fig. 2 R42776 Internal thread, G /4 Fig. R42773 push-in fitting, Ø 4 Fig. 2 R42772 / 5 bar / 5 bar / 5 bar / 5 bar / 2 6 bar / 2 6 bar / 2 6 bar / 2 6 bar - output, PNP, x IO-Link output, PNP, x IO-Link output, PNP, x IO-Link output, PNP, x IO-Link Internal thread, G /4 Fig. R42767 push-in fitting, Ø 4 Fig. 2 R42766 Internal thread, G /4 Fig. R42779 push-in fitting, Ø 4 Fig. 2 R42778 Internal thread, G /4 Fig. R42782 push-in fitting, Ø 4 Fig. 2 R4278 Internal thread, G /4 Fig. R4286 push-in fitting, Ø 4 Fig. 2 R4285 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 3 Fig.,2 M2x ) 2) 62,8 5 G/4 7,3 3) 25,9 35 25,9 G/4 3,4 3,7 4) 4 2 3 ) M2x electrical connection 2) Mounting for hat rail and wall mounting 3) Alternative pressure connection (G/4) closed with plug 4) Pressure connection G/4 22838 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
4 Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin Fig. 2,6 M2x ) 2) 62,8 5 7,3 3) 25,9 4) 35 3,4,2 3,7 25,9 4 9,4 4 2 3 ) M2x electrical connection 2) Mounting for hat rail and wall mounting 3) Alternative pressure connection (G/4) closed with plug 4) Pressure connection, tubing Ø 4 mm 2284 Display and operation area Pin assignments, M2x 29833 2 ) LCD display 2) Control panel with 3 buttons 2337 Pin : operational voltage + UB Pin 2: switch output Out2, analog: A or V, digital: PNP, NPN, push-pull Pin 3: V Pin 4: switch output Out, digital: PNP, NPN, push-pull Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 5 Block diagram, x PNP and x analog +24 V Block diagram, x NPN and x analog 2 4 Out2, analog Out 3 R L2 R L V 5 NC RL = storable postion 29834 RL = storable postion 29836 Operating mode, PNP Operating mode, NPN U B U B Out Out V 2324 V 23242 Operating mode, Push-pull U B Out V 23243 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
6 Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin Hysteresis function: switching and resetting behavior dependent on pressure p and time t, In case of overpressure Hysteresis function: switching and resetting behavior dependent on pressure p and time t, In case of underpressure [+p] [ p] t RP SP SP rp H p NO NC 23238 Out (NO) Out (NC) H: Hysteresis SP = switching point RP = resetting point Out (NC): switch output, break contact Out (NO): switch output, make contact 2986 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 7 Delayed hysteresis function: switching and resetting behavior depending on pressure p and time t [+p] [ p] 2 3 SP H rp Out (NO) ds ds dr Out (NC) H: Hysteresis SP = switching point RP = resetting point Out (NC): switch output, break contact Out (NO): switch output, make contact ds: switching delay dr = reset delay ) period of pressure over the switching point < ds: pressure sensor does not switch 2) Period of pressure over the switching point > ds: pressure sensor switches 3) Period of pressure under the resetting point > dr: pressure sensor switches 2984 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change
8 Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin Window function: switching and resetting behavior depending on pressure p and time t [+p] [ p] FH FL F Out (NO) Out (NC) FH: pressure band, upper value FL: pressure band, lower value Out (NC): switch output, break contact Out (NO): switch output, make contact 2985 Pneumatics catalog, online PDF, as of 27-3-2, AVENTICS S.à r.l., subject to change