Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Similar documents
& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

& PumpRight for PWM Control. Maximum Pump Flow and Application Rates. Max Flow GPM

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller

Y1 Tower Electric Pump Fertilizer System for John Deere Rate Controller 2000 (JDRC 2000)

Maximum Application Rates with Two 5.3 GPM Electric Pumps

Field-IQ & PumpRight for PWM Control. Pump Models & Flow Capability. Max Flow GPM

& PumpRight for PWM Control. Pump Models & Flow Capability. Max Flow GPM

*Please Note* All Instructions, Manuals, Extra Orifices, Adjustment Tools, Setting Charts, Etc. MUST BE GIVEN TO END USER!

Y1. SureFire Catalyst Electric Pump System for NutriSphere-N NH3 & John Deere

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Free-Standing Bulk Storage Tanks (Hoops Required)

Liquid Ready System T-Band / In-Furrow

CDS-JOHN BLUE COMPANY

Y1. Troubleshooting / Service Guide for SureFire PWM Liquid Application Systems. SureFire Commander II Controller

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

DeltaForce System Operation

G 5. AgXcel GX5 Hydraulic Fertilizer System Guide for: AgLeader, JD, & Trimble

ROW PRO DOWN PRESSURE

Reference Manual /12

INSTALLATION AND USER MANUAL

Clutch Control. PN: November 2013 Rev E 1

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

Start Here. From Flowmeter F L O W

Technical Training GEN I

S.I. Distributing Inc.

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Installation Instructions ISOBUS Liquid ECU

C40008 & C40009 EXHAUST BRAKES

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

PFadvantage JD 3300/4400/6600/7700; 4420

Owner's Manual. (20 Gallon Lawn & Garden Trailer Sprayer) Technical Specifications. Assembly. General Information. Warranty/Parts/Service

RECON ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL. Document revision: 1.2 Last revised: October 25, 2017

Owner's Manual. Model: LG-40-3PT-12V ( ) (40 Gallon, 12 Volt, 3 Point Sprayer w/7-nozzle Boom Assembly) Technical Specifications.

MONITORS AND CONTROLS. Liquid filled 100 PSI pressure gauge.

Owner's Manual. Model: ATVBK-710 ( ) (7-Nozzle Deluxe Boom Assembly w/brackets & Connecting Fittings) Technical Specifications.

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

Owner's Manual. Model: ATV ( ) (25 Gallon Lawn & Garden/ATV Sprayer w/standard 7-Nozzle Boom Assembly) Technical Specifications.

Owner's Manual. Model: ATVBK-710 ( ) (7-Nozzle Deluxe Boom Assembly w/connecting Fittings) Technical Specifications.

Quick Setup Guide for IntelliAg Model YP Air Pro

ELECTRIC SPRAYER CONTROL SYSTEM OWNERS MANUAL

OWNER S MANUAL. Model GALLON SPRAYER REVISION 11/11

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

TABLE OF CONTENTS GEMINI DUAL PUMP KIT

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Instructions for Micro-Trak Seed Rate Control Systems Used with AgLeader INSIGHT, INTEGRA One, Two and Three Section

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

General Information. NOTE: Be sure you have the correct instructions for the monitor system you are using. Installation Instructions

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

Owner's Manual. Model: UTL-60-12V ( ) (60 Gallon Utility Sprayer w/ 5-Nozzle Boom Assembly) Technical Specifications.

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System

Owner's Manual. Model: UTL-60-7-TSC ( ) (60 Gallon Utility Sprayer w/ 7-Nozzle Boom Assembly) Technical Specifications.

TR 300 ECONOMY TRAILER SPRAYER HAMILTON # 20, BOOMJET #10, BOOM XT & 8 ROW BOOM HYPRO 8 ROLLER PUMP

AutoSteer Installation Guide

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

See Any Application Accurately

844-E Sprayer Control. Installation, Programming and Operating

Yamaha Apex Moto-R Kill w/jacobson Roll-over valve Installation Instructions

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Cut zip ties and remove 2 plastic wiring harness brackets.

MF 9520 / 9540 / 9560, Challenger 540C / 560C

John Deere AutoTrac Control ler- Reichhardt PFP11784

Rostselmash Torum 740

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

OWNER S MANUAL. Model: LG-25-BL-QR ( ) (25 Gallon ATV Dual Nozzle Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

PowerFlo 50 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

Seed Rate Charts for the YP1225 or YP1625 Planters

ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

ADJUSTMENTS BEFORE GOING TO THE FIELD

AutoSteer Installation Guide

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

FREEDOM 2 Quick Start Guide

ONBOARD AIR HOOKUP KIT

744A SprAyer Control U S e r M A n U A l

Installation Manual v1.0: Twin CP3 Fuel Injection Kit Dodge 5.9L

MODEL NO. UTL-60-7

Assembly Instructions for A, A, A, & A

CAN Sidekick Pro Injection for Case IH 3/4XXX Installation and Operation Manual. P/N Rev. C 6/16 E27599

Diagnostic Trouble Code (DTC) List

Owner's Manual. Model: ATVBK-3025 ( ) (Boomless Nozzle Kit for ATV Mounting) Technical Specifications. Assembly. General Information

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Lexion 570R/575R, 580R/585R, 590R/595R

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Ser ving Agriculture Innovation

2013 SP Sprayer Clinic

SAC Liquid Manure Flow Meter

116 E 6TH ST KEARNEY NE Variable Rate Technology (Swath & Non Swath) Installation Guide V

OWNER S MANUAL Model: LG ( ) (25 Gallon Lawn & Garden Trailer Sprayer)

General Information. Assembly Instructions for A. Base Update 2005 Kit. Update Instructions Yield-Pro 1625 Planter

PowerFlo Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

ITEM QTY CHECK PART NUMBER DESCRIPTION

OWNER S MANUAL. Model: FS-ATV-15 ( ) (15 Gallon Lawn & Garden/ATV Sprayer) Technical Specifications. Assembly Instructions. General Information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

SCS 340 INSTALLATION AND SERVICE MANUAL

Transcription:

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS with Servo Control We Can Also Interface with These Popular Third Party Controllers: Trimble - EZ Boom & Field IQ Ag Leader - Insight Case - Pro 600/700 Raven - 0/0 Controller Manufacturer: MicroTrak Users Follow Steps through 7 of This Manual Then Refer to Microtrak Manual for Wiring Installation The John Deere GS Controller can directly control volt pumps applying liquid Fertilizer. This can be a single section where the fertilizer flow is turned on or off for the entire machine. It can also use the John Deere Swath Pro feature to automatically turn off fertilizer flow for -6 sections using electric ball valves. Application Ranges: The Endeavor system with one. electric pump can deliver. GPM of 0--0 fertilizer. Larger pumps available for higher rates. NO AGITATION flow is possible at the maximum rate. John Deere Components required: GS 600 Display GS 600 Rate Controller with 7 Pin Connector. Please consult your GS operators manual for GS operating instructions. System Components: Operations Manual The Endeavor electric pump system can be controlled from the John Deere GS display. A John Deere rate controller is required to do this. The rate controller is a black box which will be mounted outside the cab, usually on the implement. The John Deere GS will have a speed signal and the Endeavor system will use an implement height switch to turn off fertilizer flow. The speed and height inputs are part of the GS system and not included in the Endeavor kit. The rate controller has a large round 7 pin connector for application equipment. The Endeavor system will plug straight into the 7 pin connector on the Deere rate controller used on application systems. Extension harnesses may be needed depending on equipment size. The components the harness attaches to are the flow meter, the on/off connection on Electric Pump Driver (EPD) and the servo connection on the EPD.

The Electric Pump Driver (EPD) has connections:. Servo Increases and Decreases pump speed. On/Off Turns pumps on and off (also called enable). Power volt wires carrying up to 0 amps wired directly to battery. Pump Connection to pump or pumps via a Y cable The power connection is very important. If too many connectors or a light gauge wire is used, the system will not deliver the maximum application rates. How the Pump System Works: The Electric Pump Driver (EPD) sends a Servo modulated signal to the pump(s). This causes the pumps to operate from 0% to 00% of their full speed. Varying pumpspeed causes a change in pump flow. The pump flow is sent to the manifold system. Most commonly floating ball flow indicator manifolds are used. These divide the flowfrom a common inlet at the bottom to each individual column which sends flow to each row. At the top of each flow indicator is an orifice. Each row has an equal sized orifice to provide the same flow to each row. As pump speed increases, more flow is sent through each orifice. This increases the pressure drop across each orifice. A small orifice will cause a higher pressure. Electric pumps operate most efficiently at pressures under 0 psi. An orifice must be chosen to keep pump pressure low enough to supply the desired application rate. Cold fertilizer increases pressure at each orifice and must be considered when sizing orifices. Multiple Section Liquid Fertilizer Systems: Endeavor systems can optionally include electric ball valves that will divide an implement into sections. Working with the John Deere GS Swath Pro feature, these ball valves will automatically open and close to minimize overlapping application. Endeavor system will work with -6 sections. With the GS, these sections can be of varying widths. System Setup & Calibration: From the Rate Controller Screen, push the up arrow button on the right hand side. This will take you to the system setup screens. The tabs on the top of the screen will guide you to each section listed below. Implement Setup: Make the necessary settings for you implement width and each section width if using multiple sections. Initial System Operation Procedure: Thorough testing of the system at installation will prevent delays when field operation begins. All initial testing should be conducted with water. Enter all setup and calibration information prior to beginning testing.. From GS Rate Controller screen, choose the wrench on the right hand side.. Choose Tests tab at top of screen.. Choose Section Test from the drop down list. Turn the Master switch on. Push Start button with or more section boxes checked 6. Pump(s) should begin running and dispensing water once primed. If pump is not running,push the (+)Open button to increase flow. A. Check for volts (measured to ground) at the Pump On/Off connector plugged into the electric pump driver (EPD). volts will turn the pump on (0volts is off). B. While a person is holding the (+)Open and (-)Close buttons, check for volts at the servo valve connection. One direction should have volts and the other volts. C. Check for volts at the EPD power connection (large wires going to tractor battery) 7. If pump is running but no water is being dispensed, check the pump inlet for obstructions or closed valves. 8. With water being dispensed, push the Rate Controller icon in top right corner. (Do NOT stop the test) 9. Read the flow in gallons / minute. If no flow is reported, check the flow meter wiring. 0. Push the wrench icon, then push the (-) close button 0- times.. Go back to the rate controller screen, did the pump flow in gallons / minute decrease.. Try the same with the (+) increase button. (When operating at low speed and or low rates, opening the throttling valve will allow for higher pump speed and will produce a more stable flow rate to the units.). When you can read an increasing and decreasing flow using the (+) and (-) buttons,the pump system is working correctly.. Finally, check and uncheck section boxes to test each section valve. Verify the valve is working properly by looking the on/off indicator on the valve and the floating ball flow indicators for each section. When the system passes the above tests, you re ready to go to the field. To select an Indicator Ball please use graph below. System Setup: Section Valve Type: Wire Control Valve Type: Standard Flow Return Box: NOT checked Control Valve Cal: 99 The GS Control Valve Calibration can be changed to optimize performance on your specific equipment. The digit number is formatted XXYZ. Increase XX to make the system respond quicker. If set to high, the actual rate will oscillate around the target. Y is the output deadband and Z is the control deadband. Generally leave these two digits low. Read your GS Operators Manual for more information. For example, to slow your response speed, move the number from 99 to 80, changing the valve response from 99 to 80. The Endeavor system will work best with 99. Alarms Setup: OVA recommends you use the default alarm settings. Change according to operators preference. Rates Setup: Up to rates can be entered for quick changes between these rates. Check the Rate Smoothing box on this screen for best performance.

System Components:. Volt Pumps. Pump Y Adapter Harness. To Pump Y Adapter Harness. Pump Driver. Lift Switch 6. Control Valve 7. Raven Pressure 8. 787 9. Flow Meter 0. Flow Meter 9 0 6 7 8 Manifold Models Multiple flow indicators are fed by a single line and lock to the adjacent Indicator with a U-clip. Flow Indicators only need to be bolted to the mount at alternate mounting holes. Nominal distance between holes* -9/6" Hole size to drill 9/" Bolt size to use (+) (+ mount thickness) /" x "+ * When mounting multiple units measure the actual hole spacing to ensure correct hole placement. Bolt Functions of System Status LED:. On steadily if switch is on and controller is operating normally.. Flashes steadily when in HOLD.. If there is a problem with he wiring or motor, the light will flash to indicate the system status. If the console shuts down due to thermal overload due to a shorted motor or motor leads, the lamp will flash twice, pause, flash twice, pause, etc. If other system problems occur requiring a call to Ohio Valley Ag, please count the number of flashes to help with troubleshooting.. To Pump Y Adapter. Control Valve. Pump Driver. Led Indicator. Electric Pump Driver 6. EPD Power To Harness U-Clips Lock Flow Indicators Together 6

Installation Instructions Step Mouting Pump Stand Mount pump stand on tongue of planter with pumps facing the front of the planter. Install the supplied U-bolt using the flat washer and nut. Tighten U-bolt evenly until lock washer is compressed. Do not over tighten, this will cause the U-bolt to break. Step Mounting Valve Tower Step Check Valve Installation Install check valve closest to row unit as possible. The preffered method for installing check valve to row unit is by using two #0 self drilling screws to secure the check valve. They can also be installed with zip ties. meter, control valve, pressure switch and ball valves. Ball valves are labled Boom through 6. Use zip ties to secure harness to planter avoiding situations where harness could possibly become pinched or cut. Install valve tower immediately behind pump tower with valves facing the back of the planter. Install U-bolt as described in step one. Note: Mounting locations will vary from planter to planter, make sure there is adequate clearance between the pump and valve stands and any moving parts of planter before installing.. JD Rate Controller. JD Controller Harness. PEPD Power. 7 Pin Connector. JD Planter Module. Boom -6. Shut Off Valve. 787. OVA06K 6. OVA 7 Pin 7. JD 7 Pin 8. EPD Power 9. JD Rate Controller 6 7 8 9 Step Mounting the Flow Indicator Stands Mounting stands are supplied to mount flow indicators to the planter for optimal view. Mount the flow indicator stands on the planter so that you have a good view and can be easily seen from the cab of the tractor. Most common installation locations are on the wings of the planter or right behind the pump and valve stands. Mounting locations will vary from planter to planter. Step Mounting Flow Indicators Flow indicators can be arranged in clusters by clipping together individual flow indicators. Depending on how many rows each shutoff valve is feeding. Examples valve system on row planter will have clusters of 6 6 valve system on row planter will have 6 clusters of Each cluster will have one /" 90 hose barb fitting on one end and one end cap fitting on the opposite end, with 90 pushlock connectors and orfice on the top of the flow indicators. Assemble flow indicator clusters before mounting to stands. Drill two holes in the horizontal square tubing on the stands per cluster. Use the /" x " bolts supplied to mount the clusters to the stand. OVA recomends using the green ball for rates to gallons. For rates above gallons the red ball works best. Step 6 Plumbing System Using the /" rubber hose supplied, connect product tank to the pump stand inlet located on the top of the pump stand. Next connect the output hose barb on the pump stand to the flowmeter hose barb on the valve stand. Next connect each ball valve to each corresponding flow indicator cluster. It is very important to route each hose suppling the system carefully avoiding any sharp bends or kinks. Make sure there is adequate length for any hose supplying flow indicators out on the wings. Next connect the bypass/agitation hose barb located on the backside of the pump stand back to the supply tank. Connect each hose to barb fittings using the hose clamps supplied. Step 7 Plumbing Row Units Plumb the row units using the /8" black tubing supplied in kit. Route the tubing from each flow indicator back to the check valve installed on the row units. Check to make sure the tubing is not smashed or kinked. Secure tubing using zip ties. Insert end of tubing into pushlock fitting on flow indicator and check valve. Note: The /8" tubing does NOT have to be all the same length. Next install /" black tubing from the check valve down to the row unit. Connect the other end of the /" tubing to whatever method to used to apply liquid. For in furrow applications options include seed firmers, total tubular or the /" tubing can be zip tied directly to seed tube allowing the liquid to dribble into furrow. Another option is to T-band (spray) liquid into furrow using spray arms. Step 8 Main Harness Installation Note: Microtrack Controller Sytems owners refer to microtrack manual for wiring installation. John Deere systems using 600 and 60 continue with step 8. Locate gray power harness (part #787 or #89). Next locate power Acc. port on the planter harness, remove terminator from power port and connect power harness connector (end with fuse holder) to planter power port. Connect opposite end of power harness to the epd located on the pump tower. Next locate main Endeavor harness (part #OVA06K). Next locate the round 7 pin connector on the JD Liquid Rate Controller, connect the female 7 pin connector to the male 7 pin connector on the Endeavor harness. Next identify labled connectors on Endeavor harness, connect to appropriate component on pump and valve stand, pump driver, flow Step 9 Installing Lift Switch Install lift switch by bolting magnets to lift switch body. Next position lift switch to planter wheel linkage so when the planter is down there is tension on lift switch spring and no tension when planter is up. Next plug lift switch into the short leg of Y-cable supplied. Plug the long leg of the Y-cable into the lift switch plug on the JD rate controller. Last plug the remaining connector plug into the main wiring harness labled lift switch. Step 0 System Setup and Testing Refer to System Setup and Calibration on page of this booklet. Continue on the Implement Setup, System Setup, Alarms Setup, Rates Setup and Initial System Operation Procedure to complete system Installation. If any additional information is required please feel free to contact OVA for further assistance. End of Season Cleaning and Winterization OVA recommends flushing your fertilizer pump and complete system with adequate amounts of water. Next, use RV antifreeze to winterize your your system by pumping an adequate amount through all components. At the beginning of the next season, begin with water to verify the system is in working order with no leaks. 6 7

Control Unit On/Off Agitation Valve Banjo T Strainer 0 Mesh Throttle Valve Pump Single. gpm (Standard) Single 7 gpm (Option) Twin. gpm (Option) Twin. gpm (Option) Ohio Valley Ag Visit Us Online @ www.ohiovalleyag.com sales@ohiovalleyag.com Owensboro, KY 60 W. nd Street 866.6.777 Russellville, KY 0 N. Thurston Drive 866.90.08 Greensburg, IN 8 North Liberty Circle W. 8.0.0 Decatur, IL 909 N Brush College Rd. 800..7