Butterfly valves PN6, PN10, PN16

Similar documents
Butterfly valves PN 16

Butterfly valves PN 16

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Butterfly valves, PN6, PN10, PN16

2-port seat valves PN16 with flanged connection

3-port seat valves PN16 with flanged connection

3-port seat valves PN16 with flanged connection

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

3-port seat valves PN6 with flanged connection

3-port seat valves PN10 with flanged connection

2-port ball valves with flanged connection, PN25

3-port seat valves PN40 with flanged connection

3-port seat valves, external thread, PN16

Three-port slipper valves PN10, female-threaded

2-port seat valves PN25 with flanged connection

Butterfly valves PN6, PN10, PN16

3-Port Seat Valves with Flange, PN 10

3-Port Seat Valves with Flange, PN 6

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

2-port and 3-port ball valves PN 40

2-Port Seat Valves with Flange, PN 25

2-port and 3-port valves with T-bypass PN 16

2-Port Seat Valves with Flange, PN 25

Electromotoric Actuators

Electromotoric actuators

3-Port Seat Valves with Male Thread, PN 16

3-Port Seat Valves with Male Thread, PN 16

2-Port and 3-Port Zone Valves PN 16

Combi valves PN 16 with flanged connections

2- and 3-port valves with flanged connections, PN 16

CONTROL EQUIPMENT STAZ-16, STBZ-16

2- and 3-port valves with flanged connections, PN 16

2-Port and 3-Port Zone Valves, PN 16 / 20

3-port valves vxf42..

Electromotoric Actuators

2- and 3-port valves with flanged connections, PN 25

2-Port and 3-Port Zone Valves PN 16

Electromotoric Actuators

2-Port and 3-Port Zone Valves & Actuators, PN16

2- and 3-port valves with flanged connections, PN 6

Electromotoric actuators

Electromotoric Actuators

2- and 3-port valves with flanged connections, PN 16

2-port and 3-port terminal unit valves PN16

Electromotoric Actuators

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45..Q with pressure test points. Combi valves, PN 25

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

2- and 3-port valves with flanged connections, PN 25

Modulating control valves with magnetic actuator PN 16

Modulating control valves with magnetic actuators, PN 16

ACVATIX MiniCombiValves (MCV)

2-Port and 3-Port Zone Valves, PN16

Two-port seat valves with male thread, PN16

2-port shutoff valves and 3-port changeover ball valves, PN 40, with internally threaded connection

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

VPI45..Q with pressure test points. Combi valves, PN 25

Electro-hydraulic actuators for valves

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

ACVATIX MiniCombiValves (MCV)

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

SQL35.00 SQL85.00 SQK angle of rotation

Modulating Control Valve PN 16 with Magnetic Actuator

Electromotoric Actuators

Modulating control valves with magnetic actuator PN 16

MXG461.. MXG461..P MXF461.. MXF461..P

2- and 3- port valves with flanged connections, PN 16

Acvatix Valves VVF..,VXF.., VVG41.., VXG41.., VVI41.., VXI41.. Basic Documentation - Version changes

Electro-hydraulic actuators for valves

Electrical Actuators

Modulating control valve with magnetic actuator PN16

Operating instruction Refrigerant Valves PS45

Modulating control valve PN16 with magnetic actuator

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

Modulating control valves with magnetic actuators, PN 16

VPP46.. Combi valves, PN 25 VPP46..Q VPI46.. VPI46..Q ACVATIX. for rooms, zones, ventilation and air-conditioning systems

2-position electric actuators with Ball valves VBZ ½...11/4

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Modulating refrigerant valves, PN40

VXF53.. VVF53.. Acvatix Valves VVF..,VXF.. Basic Documentation. CE1P4030en Building Technologies

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

Rotary actuators for ball valves

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Two-port and three-port small valves PN16, ANSI Class 250

In district heating, heating, ventilating, and air conditioning systems as DFRQWUROYDOYH

Modulating control valve PN16 with magnetic actuator

Electric actuators for small valves

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

Characterized Control Valves Actuators. Technical Databook Ver. 2

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Motorized Butterfly Valve

BOAX-B Mat E. Type Series Booklet

BQE: 3-way flanged valve, PN 16

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Type overview. R B2 en-gb subject to changes 1

Transcription:

4 131 ACVATIX Butterfly valves PN6, PN10, PN16 VKF41.. Grey cast iron housing EN-GJL-2 DN 40 200 k vs 4000 m 3 /h For fitting between PN 6, PN 10, PN 16 counter-flanges to ISO 7005 Metallic tight-closing Angle of rotation 90 No maintenance required Can be fitted with type SQK33.00 or SAL..T10 electromotoric actuators Use For use as a control or shut-off valve in heating, ventilation and air conditioning systems, e.g.: In closed circuits For 2-position controls (open/closed) For boiler and chiller sequencing circuits To open or close the flow to a heat exchanger or to complete plant sections In applications where minimal leakage through the fully closed valve is allowable CM1N4131en 27.07.2011 Building Technologies

Type summary Product number DN k vs Leakage rate Velocity of water flow 1) SAL31..T10 [m 3 /h] in % of k vs -value SQK33.. SAL81..T10 SAL61..T10 VKF41.40 40 0.22 4 VKF41. 0.14 VKF41.65 65 200 0.09 VKF41. 400 0.06 4 2.5 VKF41.100 100 760 0.04 VKF41.125 125 1000 0.04 VKF41.1 1 2100 0.02 VKF41.200 200 4000 0.01 2.5 1.5 1) Recommended maximum velocity of flow and the butterfly valve fully open k vs Nominal flow rate of cold water (5 30 C) through the fully open butterfly valve by a differential pressure of 100 kpa (1 bar) Accessories Designation Product Stock number number Description Mounting set ASK33N S55845-Z101 For mounting SAL..T10 actuators on VKF41.., DN 40 200 Mounting set ASK33 ASK33 For mounting SQK33.00 actuators on VKF41.., DN 40 Ordering Example: Product number Stock number Designation Quantity VVF41. VVF41. Butterfly valve VKF41.40 including centering sleeves 1 SAL31.03 S55162-A109 Actuator SAL31.03 1 ASK33N S55845-Z101 Mounting set ASK33N 1 Delivery Spare parts, Rev. no. Butterfly valve, actuator and mounting set are packed separately. 4 centering sleeves are supplied with each butterfly valve, for fitting the valve between PN 10 and PN 16 flanges. See overview, page 8. 2/8

Equipment combinations Mounting set Electromotoric actuator SQK33.00 SAL..T10 SQK33.00 SAL..T10 Butterfly valve Δp s [kpa] VKF41.40 ASK33 200 VKF41. VKF41.65 0 VKF41. VKF41.100 ASK33N VKF41.125 300 VKF41.1 2 VKF41.200 125 Actuator overview Δp s Product number Maximum permissible differential pressure at which the motorized butterfly valve will close securely against the pressure (close off pressure) Actuator type Operating voltage Positioning signal Spring return Positioning time Positioning force Data sheet SQK33.00 AC 230 V 125 s 5 Nm N46 SAL31.00T10 120 s AC 230 V SAL31.03T10 3-position 30 s SAL81.00T10 Electromotoric 30 s 10 Nm N42 120 s Nein SAL81.03T10 SAL61.00T10 AC/DC 24 V DC 0 10 V 120 s SAL61.03T10 DC 4 20 ma 30 s 0 1000 Ω Mechanical design Butterfly valve Mounting set Stainless steel disk and shaft. The valve disk closes against an end-stop. The position of the valve disc is indicated by a notch on the front of the shaft. In all cases, a mounting set is required to assemble the actuators on a VKF41.. valve. 3/8

Flow diagram 10000 00 6000 00 4000 3000 2000 10 1000 0 600 0 400 300 200 1 100 60 40 30 20 10 8 6 5 4 3 2 1 0,01 1 0,02 2 0,03 0,04 0,05 0,06 0,08 0,1 3 4 5 6 DN 200 1 125 100 65 40 8 10 k VS 4000 2100 1000 760 400 200 0,2 20 0,3 0,4 0,5 0,6 0,8 1 30 40 60 100 0 600 0 400 300 2 200 1 100 60 40 30 25 20 15 10 8 6 5 4 3 2,5 2 1,5 1 0,8 0,6 0,5 0,4 0,3 0,25 Δp v100 = Differential pressure across the fully open butterfly valve by a volume flow V 100 V 100 = Volume flow through the fully open butterfly valve 100 kpa = 1 bar 10 mwc 1 m 3 / h = 0.278 l/s water at 20 C Engineering notes The VKF41.. butterfly valves can accommodate flow in either direction. In heating systems, the valve should preferably be installed in the return, where the seal will be exposed to lower temperatures, so extending its service life. Warning To avoid pressure shocks on the butterfly valve, the VKF41.. must be driven to its fully open position (either manually or via positioning signal Y1) prior to activating the pump(s). 4/8

Mounting notes The Mounting Instructions 4 319 8927 0 are enclosed in the product packaging. VKF41.. butterfly valves can be mounted in PN 6, PN 10, PN 16 applications. Orientation 90 90 Upright to horizontal 4716Z16 The valve, actuator and mounting set are easily assembled directly on site. There is no need for special tools or calibration. Commissioning notes The butterfly valve must be commissioned only with the mounting set and actuator correctly assembled. Disk rotated clockwise: Increasing flow Disk rotated anti-clockwise: Decreasing flow Maintenance The VKF41.. butterfly valves require no maintenance. Caution Before performing any service work on the valve, actuator or mounting set: Switch off the pump and power supply Close the main shut-off valves in the pipework Release pressure in the pipes and allow them to cool down completely If necessary, disconnect electrical connections from terminals. The valve must be re-commissioned only with the correctly mounted actuator. Disposal Before disposal the valve must be dismantled and separated into its various constituent materials. Legislation may demand special handling of certain components, or it may be sensible from a ecological point of view. Current local legislation must be observed. Warranty The technical data given for these applications is valid only in conjunction with the Siemens actuators as detailed under "Equipment combinations", page 3. All terms of the warranty will be invalidated by the use of actuators from other manufacturers. 5/8

Technical data Operating data PN class PN 16 to EN1333 Permissible operating pressure 1600 kpa (16 bar) Leakage rate refer to "Type summary", page 2 Permissible media chilled water, low temperature hot water, high temperature hot water, brine, softened water, water with anti-freeze; recommendation: water treatment to VDI2035 Medium temperature -10 120 C Flanged connection for pipes PN 6, PN 10, PN 16 to ISO7005 Angle of rotation 90 (to end stop) Standards Pressure Equipment Directive PED 97/23/EC Pressure Accessories as per article 1, section 2.1.4 Fluid group 2: DN 40 without CE-marking as per article 3, section 3 (sound engineering practice) DN 65 200 category I, with CE-marking Environmental compatibility ISO 14001 (Environment) ISO 9001 (Quality) SN 363 (Environmentally compatible products) RL 2002/95/EG (RoHS) Materials Housing grey cast iron EN-GJL-2 Shaft stainless steel 1.4104 Valve disc stainless steel 1.4016 Shaft seal EPDM O-rings Dimensions refer to "Dimensions" Weight refer to "Dimensions" Dimensions VKF41.. with SQK33.00 and ASK33 Dimensions in mm 6/8

VKF41.. with SAL..T10 and ASK33N > 100 mm: minimum clearance from the wall or ceiling > 200 mm: minimum clearance for mounting, connection, operation, maintenance etc 7/8

Type DN A B C E F E F H kg ø ø PN 6 PN 10, PN 16 SQK33.00 SAL..T10 [kg] VKF41.40 40 30 130 87 100 M12 (4x) 110 M16 (4x) 249 275 1.72 VKF41. 30 140 97 110 M12 (4x) 125 M16 (4x) 2 1.94 VKF41.65 65 30 160 117 130 M12 (4x) 145 M16 (4x) 287.5 2.37 VKF41. 30 175 133 1 M16 (4x) 160 M16 (8x) 295 2.63 VKF41.100 100 30 195 153 170 M16 (4x) 1 M16 (8x) 305 2.92 VKF41.125 125 40 225 183 200 M16 (8x) 210 M16 (8x) 325.5 5.25 VKF41.1 1 40 255 208 225 M16 (8x) 240 M20 (8x) 338 6.29 VKF41.200 200 40 310 263 2 M16 (8x) 295 M20 (8x) for PN 10 M20 (12x) for PN 16 363 8.44 Spare parts DN = Nominal size H = Total actuator height plus minimum distance to the wall or the ceiling for mounting, connection, operation, maintenance etc. Order number for spare parts Centering sleeves O-ring service kit Product number VKF41.40 4 676 8877 0 4 679 8814 0 VKF41. 4 676 8878 0 4 679 8814 0 VKF41.65 4 676 8878 0 4 679 8814 0 VKF41. 4 676 8878 0 4 679 8814 0 VKF41.100 4 676 8878 0 4 679 8814 0 VKF41.125 4 676 8879 0 4 679 8815 0 VKF41.1 4 676 88 0 4 679 8815 0 VKF41.200 4 676 88 0 4 679 8815 0 Revision numbers Type Valid from rev. no. Type Valid from rev. no. Type Valid from rev. no. VKF41.40 /01 VKF41. /01 VKF41.1 /01 VKF41. /01 VKF41.100 /01 VKF41.200 /01 VKF41.65 /01 VKF41.125 /01 8/8 2000-2011 Siemens Switzerland Ltd Subject to alteration