IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

Similar documents
IEC Separable Connectors 17.5 kv/24 kv, 630A

INSTALLATION PRODUCTION TESTS

15 kv Class Fused Loadbreak Elbow Connector with Interchangeable Fuse Capability

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

600 A 35 kv class BT-TAP deadbreak connector

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

600 A 15 kv class T-OP II deadbreak connector

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

600 A 25 kv class BT-TAP deadbreak connector

600 A 35 kv class separable splices

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

600 A 35 kv class deadbreak accessories, tools, and replacement parts

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Product Description: Objective and Certification: Test Samples and Test Cable:

Loadbreak Apparatus Connectors

GROUP C. Apparatus Bushing.

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors


1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

25 kv Apparatus Bushings

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Molded Current-Limiting Fuse

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

25 kv class fused loadbreak elbow connector

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

Eaton s Cooper Power Systems

High Voltage Accessories up to 72.5 kv

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

Medium Voltage. Joints & Terminations

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Completing the picture

15 kv and 25 kv Thru-Bushings

AIR CORE REACTORS. Phoenix Electric Corporation

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

PRODUCT BROCHURE. Elastimold ComboT integral separable connectors

Wind Power Solutions. Make Energy Renewable and Reliable!

GROUP D. Switch & Protective device.

Separable Connectors and Kits

Branch Splice QS-2001B

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

High Voltage Joints and Terminations up to 72,5 kv 145 kv

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Extensible Unit - VCE2a

power cable accessories

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Low voltage bushings for pad-mounted distribution transformers Technical information guide

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Kuhlman Electric Corporation Volt Instrument Transformers

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

High Voltage Copper, Smooth Aluminum Shield/Sheath

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

600 A 15 and 25 kv class Cleer grounding elbow

Kuhlman Electric Corporation Volt Instrument Transformers

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

JOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations

DM Condenser bushings, kV DURESCA

Nexans Network Solutions Div. Euromold

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

A 1.2 kv class externally removable secondary bushing

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

600 A 15 kv class Cleer loadbreak connector system

600 A 28 kv class Cleer loadbreak connector system

Power cable accessories catalogue


High Voltage Aluminum, Smooth Aluminum Shield/Sheath

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

Zinc Oxide Surge Arrester PEXLIM Q

CERTIFIED TEST REPORT. Cooper Power Systems. 25 kv Class 200 Amp 15.2/26.3 kv SEPARABLE CONNECTOR SYSTEM

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Transcription:

www.chardongroup.com IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector Application Chardon Front T-Body / Coupling (Rear) T-Body connectors are fully screened and fully submersible when mated with proper bushings or plugs. The products are used to terminate polymeric cable to dead front apparatus such as transformers, switchgear, and other equipment. They can be used for 36kV and 42 kv applications. The Chardon T-body connectors are suitable for indoor or outdoor applications, and are able to be used for all polymeric cable types ( XLPE, ETP, etc.) with copper or aluminum conductors. The design is especially suited for the harsh off-shore or wind farm environment, where long runs and large cable sizes are needed. Key Features Provides a fully shielded and submersible connection when mated with the proper bushing or plug. Type C 1250A interface. Mounting can be vertical, horizontal, or any angle in between. No minimum phase clearance requirements. 100% electrical tested in production. Product Ratings Maximum Voltage Class (U ): AC 5 Minute Withstand: DC 15 Minute Voltage Withstand: Minimum Corona Voltage Level: BIL and Full Wave Crest (Impulse): Thermal Short Circuit (Conductor, 3 sec.) Dynamic Short Circuit Continuous Current Production Tests Tests conducted in accordance with IEC 60502-4 Minimum Corona Voltage Level 45 kv 10pC AC 5 Minute Withstand 117 kv m 42 kv 117 kv 125 kv 45 kv < 10 pc 200 kv 45 ka 100 ka 1250 A 42FDT1250-42RDT1250-060418 REV12

Detailed composition of the Chardon 36 kv and 42 kv Front T-body Connector STUD Zinc plated, threaded steel stud 185mm (7.28") INSULATING PLUG Molded epoxy insulating plug provides excellent electrical, thermal and mechanical reliability. Ф101mm (3.98") 391mm (15.39") CONDUCTING INSERT conducting insert provides coronafree electrostatic shielding of the compression connector. INSULATION LAYER High quality peroxide cured EPDM insulation is mixed and formulated in-house for complete control of rubber characteristics. CONDUCTING SHIELD conducting shield provides ground shield continuity. CABLE ADAPTER Molded cable adapter, sized to fit the cable insulation, provides stress relief for the terminated cable. RUBBER END CAP Molded EPDM conducting rubber end cap protects and grounds the insulating plug test point. COMPRESSION CONNECTOR/ SHEAR BOLT CONNECTOR Compression connector / shear bolt connector made of aluminum, copper, or bimetal(aluminum/copper). DRAIN WIRE TAB Drain wire table provide a convenient point to connect drain wire to ensure grounding of the connector shield. Ф116mm (4.57")

Detailed composition of the Chardon 36 kv and 42 kv Coupling (Rear) T-body Connector 315mm (12.40") STUD Zinc plated, threaded steel stud CONTACT ROD Copper made contact rod provides a consistent current transfer path. INSULATING PLUG Molded epoxy insulating plug provides excellent electrical, thermal and mechanical reliability. Ф101mm (3.98") 391mm (15.39") Ф116mm (4.57") 129mm (5.08") RUBBER END CAP Molded EPDM conducting rubber end cap protects and grounds the insulating plug test point. CONDUCTING INSERT conducting insert provides coronafree electrostatic shielding of the compression connector. COMPRESSION CONNECTOR /SHEAR BOLT CONNECTOR Compression connector / shear bolt connector made of aluminum, copper, or bi-metal(aluminum/copper). INSULATION LAYER High quality peroxide cured EPDM insulation is mixed and formulated in-house for complete control of rubber characteristics. CONDUCTING SHIELD conducting shield provides ground shield continuity. DRAIN WIRE TAB Drain wire table provide a convenient point to connect drain wire to ensure grounding of the connector shield. CABLE ADAPTER Molded cable adapter, sized to fit the cable insulation, provides stress relief for the terminated cable.

ORDERING INFORMATION STEP 1 Code 42 - STEP 1 STEP 2 STEP 3 Selection of Front / Rear T-body FDT RDT STEP 2 Selection of Cable Insulation Dimension D E F G H J K L M N P Q R S T U V Front T-body Coupling(Rear)T-body 19.10-25.00 23.60-26.40 24.90-28.30 26.40-29.90 27.80-31.50 29.50-33.20 31.00-34.90 32.60-35.40 34.40-38.60 37.70-40.50 38.90-41.70 40.00-42.80 42.30-45.30 44.60-47.60 46.90-49.90 49.20-52.20 51.40-54.50 1250 ORDERING EXAMPLE: For a CHARDON 42 kv Front T-body with cable insulation outer dimension of 26.4 mm and a conductor size of 185 mm2 with copper compression connector, the part number would be as follows. 42 - FDT 1250 E 185 C STEP 3 Selection of Conductor Size 25 35 50 70 95 120 150 185 240 300 400 500 630 STEP 4 Code www.chardongroup.com If a shear bolt connector is selected in this kit, the part number would be 42-FDT1250E-SBC-B-25-50/1 STEP 4 42 - FDT 1250 E SBC-B-25-50/1 Conductor Code Conductor Size(mm²) Selection of Compression Connector Material B Bi-metal ( Al & Cu ) C Copper 25 35 50 70 95 120 150 185 240 300 400 500 630

Chardon Shear Bolt Connector Example: ForaShear Bolt Connector with a conductor Range between 20-50 mm2, the part number would be : SBC-B-25-50/1 CATALOG NO. SBC-B-25-50/1 SBC-B-70-95/1 SBC-B-70-120/2 SBC-B-150-240/2 SBC-B-300-400/3 SBC-B-500-850/3 Conductor Range(mm2). 25-50 70-95 70-120 150-240 300-400 500-630 Chardon Taiwan Corporation No. 37 Min-Chie Road Tung Lo Industrial Park Miao Li, Taiwan 366 Phone: 886-3-798-4385 Fax: 886-3-798-4770