MANUFACTURED IN THE UK

Similar documents
2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MANUFACTURED IN THE UK

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

LED Emergency Luminaires

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

LED emergency exit signage from Channel Safety Systems

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

UL AND CODE COMPLIANCE

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

Emergency lighting units EM series

Installation and Operation Instructions 10/04/13

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Emergency lighting units PC COMBO

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Emergency lighting units EM converterled

Emergency lighting units PC COMBO

Emergency lighting units EM converterled

Emergency lighting units EM powerled

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Specification Sheet for 2D LED Light

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Zone 1 Linear Range - Installation Guide

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Operating Instructions

PC T8 TEC, W PC TEC

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Central Battery Systems Loadstar AC/DC Systems

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Emergency lighting units EM INVERTER

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Emergency lighting units EM converterled

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Emergency lighting units EM LED Light Engines

LED.Commercial 12W LED DD

Emergency lighting units EM powerled

Norwich Hostry Norwich, UK. Downlight Lighting

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Operating Instructions

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Model: CF16MS / CF16CR / CF16WH CF28MS / CF28CR / CF28WH

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Emergency lighting units EM powerled

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements.

DTFA Elite. Optics. IP65/54 recessed luminaire with sealed twin frame construction. Prismatic Diffuser. Cam Jacking Bracket

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

TANEK INTRODUCTION APPLICATION PRODUCT SPECIFICATION

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Emergency lighting units EM Inverter

SURE-LITES FBP140XLP Instruction Manual

High Efficiency Lighting units

10W LED Die Cast Small Rectangle Bulkhead Light

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

7 Lighting Technology

GDS-133-REV1 08th November 2012 FIE. Making Perfect Sense

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Serial LED Curve. Product Specification

EM converterled BASIC Installation and wiring instructions

EMERGENCY ONE-LED TM OMNI-LED DST TM LED DALI EMERGENCY CONVERSION MODULE WITH SELF-TEST

FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact

Floodlight Range Installation Guide

EMERGENCY ONE-LED TM UNITY-LED TM LED MAINS/EMERGENCY DRIVER

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Emergency lighting units EM powerled

Existalite ZV 4-pole self-contained emergency lighting conversion module

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Transcription:

The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Trojan leads vandal-resistant IP65 technology. With a hinged gear tray, and Time-in-a-Box packaging, installation is swift and easy. G GE Lighting 2D lamps are fitted as standard. VERSIONS High Frequency 3hr Maintained (16W & 28W) Clear or Opal diffuser Black or White base OPTIONS Security Screws I65 A C MANUFACTURED IN THE UK Fittings are manufactured and tested in accordance with BS EN 60598. They are also RoHS compliant.

GASKETING - POURED TO PERFECTION Using a PC controlled contour robot, our FIPFG (Formed In Place Foam Gasket) sealing system creates a poured gasket seal. We use two chemically safe components which are combined and expand to form a poured two-part gasket which can blend any join and fill all uneven surfaces into a one piece seal. Whenever you cut and splice, the join will always be a weak point in your finished product. The distinct advantage of a formed in place foam gasket, compared to adding any other secondary sponge material, is that it is formed and adheres to the product as a one piece application, requiring no additional fixing. TIME-IN-A-BOX is a unique packaging method, which presents component parts to the installer in exactly the order required. All parts are kept safely in the box - in protective wrappings to avoid breakages - until required, an added advantage if there is a prolonged period between first and second fix. In independently controlled and observed tests, Time-in-a-Box has been found to halve the fitting time required over a comparable luminaire, thus significantly contributing to efficiency and cost savings. IN A BOX SAVES YOU TIME TIME SAVES YOU MONEY Open the box Take out the base moulding Attach to surface Take out gear tray Present to moulding Tighten screws Connect supply Close gear tray Remove lamp from protective wrapping Clip in place Take diffuser from box Screw in place Job done

POLYCARBONATE DIFFUSER WITH IP65 SEAL RETAINED SECURING SCREWS GE 2D LAMP GEAR TRAY RELEASE SCREW HINGED GEAR TRAY ALL APPROVED COMPONENTS POLYCARBONATE BODY

INSTALLATION AND OPERATING INSTRUCTIONS THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition of the IEE Electrical Regulations. Information regarding Part Number, Description, Voltage, Frequency, IP Rating and Lamp type is shown on the label affixed to the box containing the luminaire. Pre-installation ALWAYS TURN OFF THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION Make sure that the mains supply is compatible with the fitting. If IP rating has to be retained a cable gland of the correct IP rating must be used and any fixing holes must be filled with a proprietary silicon sealing compound. High voltage insulation test equipment MUST NOT be used on High Frequency, Emergency or Dimming luminaires. The luminaire is suitable for use within ambient temperature range of -10º C to +25º C ONLY. PIR and electronic time switches are not recommended for these luminaries. If used, ensure that there is no Leakage Current when in the Off position and an On time of not less than 20 minutes. Failure to ensure this could potentially impair the performance of the luminaire. Lamp Switching Cycles / Lamp Life CONSTANT SWITCHING REDUCES LAMP LIFE Typical switching cycles should achieve 100% of the manufacturers stated lamp life, however, switching every 5 minutes would reduce this to 20%. Installation Take out the base moulding. Drill out the cable entry and any other Cut Outs required. If cut outs are required for conduit fixing (Not BESA) make sure that the hole is drilled high enough in the side of the base to allow the inside nut to be fitted. Feed the incoming mains through the cable entry gland and secure the base to the mounting surface required using the mounting points provided (failure to do this will cause the fitting to distort) with fixings suitable to support the fitting and for the material to which the base is being attached Put the gear tray into the Hinge position, tighten the two screws and allow the Gear tray to hinge open. Make sure that the incoming mains cable is long enough to allow the Gear Tray to be completely opened. Connect the incoming mains to the terminal block. If using stranded cables, make sure that no stray wires are omitted from the terminal connection.

Flying lead or Direct Wiring Standard TB Wiring Incoming Supply Neutral Blue or Black Earth Line Brown or Red N L Blue Gn / Y Brown White Gn / Y White Luminaire Wiring Emergency TB Wiring Incoming Supply Neutral Earth Un-switched Line Switched Line Blue or Black Brown or Red Yellow N 1 2 Blue Gn / Y Brown White Luminaire Wiring To make the fitting Non Maintained leave out the Switched Line Close the Gear Tray (make sure that all cables are clear of the Gear Tray components) and secure with the screw provided. Fit the lamp making sure that it is securely clipped in. Screw on the diffuser making sure that it is correctly tightened to locate in the seal. ADDITIONAL NOTES FOR EMERGENCY LUMINAIRES THIS PRODUCT IS APPROVED FOR SURFACE MOUNTING ONLY These instructions are for non-maintained, maintained and sustained emergency light fittings, which incorporate a fluorescent lamp(s). The ballast is electronic, consisting of a high frequency inverter, battery charger, charge indicator, and battery deep discharge protection circuit. These fittings are self-contained without Rest Mode facility. All emergency versions are 3 hour duration. The Mains supply and the Battery connection must be disconnected before servicing or maintenance. VERY IMPORTANT The battery connections must be left disconnected during installation if the site supply is switched off at the end of the day. Failure to do this will damage the fitting.

Circuits The emergency mains supply must be connected to a direct source via a Key Switch (for test purposes only). The switched line must be wired so that it disconnects from the luminaire if the Key Switch is switched off (no power to the fitting). NOTE: The incoming supply earth MUST be connected. NOTE: - Both luminaire supplies must be broken simultaneously (switched and unswitched) when testing. Connections into the ballast must not exceed 2.5mm 2. After connecting the mains supply, check that the charge indicator lamp (LED) is illuminated. The fluorescent lamp should operate when the luminaire is switched on (maintained and sustained only). An initial uninterrupted minimum charge period of 36 hours should always be allowed before testing the module for its rated duration. The recommended maximum battery storage period of one year should not be exceeded. If batteries have been left in a discharged state, one or more full charge / discharge cycles may be necessary to restore them to their normal capacity. Stick the supplied rating label to the luminaire where it can be seen. i.e. On the base, if surface mounted. On the gear tray, if not practical to stick on the base. MUST not be fitted on the diffuser.

Routine maintenance Routine maintenance must be carried out in compliance with the requirements of the British Standards Institute Code of Practice BS5266: Part 1 - Emergency Lighting of Premises. The following tests assume a three-hour system Daily: Monthly: Six monthly: Three years: 1 Check that any recorded faults have been rectified. 2 Check that the emergency lamp is operative. 3 Check that the charge indicator light is illuminated. 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for three minutes. 2 After reverting back to mains supply check the charge indicator light is illuminated. 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least one hour. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 24 hours to recharge before becoming fully operational. 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least 3 hours. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 36 hours to recharge before becoming fully operational. It is recommended that battery packs and lamps are replaced every 4 years or sooner if the unit performance requirements fail to be met. To maintain optimum unit performance, only approved replacement battery packs and lamps must be used. All routine maintenance checks must be recorded on the unit Test Record / Installation sheet and must be made available for inspection at all times. INSTALLATION / COMMISSIONING AND TEST RECORD Model No Type Installed By Commissioned By Location Serial No (on gear tray) Date Date Routine Test Record First Year Second Year Third Year Fourth Year Fifth Year Monthly Test Signed Date Signed Date Signed Date Signed Date Signed Date 1 Hour Duration 1 Hour Duration Full Duration SAMPLE

GENERAL ROUTINE MAINTENANCE At commissioning and handing over of the installation, ensure that a copy of this data is presented to the authority responsible for the operation, maintenance and repair of Luminaires. Cleaning of the Luminaire or lamp replacement must only be carried out after the fitting has been isolated from the electrical supply. ALWAYS check before servicing. Cleaning should be carried out at regular intervals to ensure that contaminants do not accumulate to an extent that will impair the thermal safety of the Luminaire, or degrade the optical performance of the lamp. DO NOT use Spirit based cleaners. Failed lamps must be replaced immediately, with Lamps of the same type, if a Starter Switch is fitted, this should be changed at the same time. Undetected or unattended failed lamp replacement will result in the Ballast unit overheating and ultimately will cause its failure, rendering the fitting useless. Notes: This luminaire should not be modified or repaired by any persons other than those nominated by the manufacturer. Any unauthorised modification or repair may render the luminaire unsafe and will invalidate the warranty and conformance to any safety or safety standards that may apply. The company will accept no responsibility for any modified fittings or for any damage caused as a result of modifications. All details are given as guidance only and do not constitute a contract. We reserve the right to change or withdraw products without notice. Performance and Warranty This product is warranted for twelve months from the date of installation, provided that the installation is carried out within two months of purchase, subject to the following conditions. This warranty will only be valid if the fittings have remained unmodified and used as per this instruction leaflet and our literature. Fern - Howard Ltd. shall not be liable for any consequential loss or damage caused directly or indirectly by any defective or otherwise. Battery packs are guaranteed for 12 months but are expected to have a life of at least four years if used within the specified temperature limits. Disposal The disposal of any electrical equipment, including this fitting may be subject to Local Authority Regulations and therefore should be consulted for specific guidance. The batteries within this fitting are Nickel Cadmium and must be disposed of as per Local Authority Regulations for the disposal of toxic waste.

2 PIN LAMP SWITCH START 4 PIN LAMP SWITCH START HIGH FREQUENCY EMERGENCY MAINTAINED

Lamp Lumen Output (Mains- Mode) Approx Lamp Life (Hrs) Nominal Lamp Current A MAGNETIC HF EM Parallel Correction Capacitor Corrected Lamp Current A Circuit Watts Corrected HF Current A Circuit Watts BLF HF BLF Emergency Normal BLF Emergency EM Mode 16W 1050 10,000 0.195 2uf 0.09 27.83 0.121 18.0 0.960 0.950 0.180 28W 2250 15,000 0.320 4uf 0.15 34.5 0.130 28.7 0.960 0.750 0.120 38W 3000 15,000 0.430 4uf 0.200 46.0 0.180 39.7 0.960 Lamp Weight Weight HF Weight EM 16W 1.54 1.16 2.07 Lumen Output In Emergency Mode Lamp Mains EM 1Hr EM 2Hr EM 3Hr 28W 1.75 1.3 2.07 16W 1050 200 196 184 38W 1.9 1.37 28W 2250 248 248 216 150 o 180 o 150 o Size 254 x 254mm x 95 Deep Cable Entry Centre Rear BS Style Body Material Polycarbonate 120 o 120 o Diffuser Material Polycarbonate Gear Tray Material Polycarbonate Lamp GE 2D 3500K Wiring TB 2 x 2.5mm 2 90 o 90 o Diffuser Fixing 2 Steel Screws BZP Control Voltage 240V 50Hz 40 60 o 80 60 o 120 30 o C0 / C180 0 o cd / 1000 im 30 o C90 / C270 LOR = 0.65 SHR MAX = 1.63 SHR NOM = 1.50 Room Reflectances Room Index C W F 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0.20 0.32 0.37 0.41 0.45 0.49 0.53 0.55 0.58 0.60 0.30 0.26 0.31 0.36 0.39 0.45 0.48 0.51 0.55 0.57 0.10 0.22 0.27 0.32 0.35 0.41 0.45 0.48 0.52 0.55 0.50 0.50 0.20 0.29 0.34 0.38 0.41 0.46 0.49 0.51 0.54 0.56 0.30 0.25 0.29 0.34 0.37 0.42 0.45 0.47 0.51 0.53 0.10 0.22 0.26 0.30 0.34 0.38 0.42 0.45 0.48 0.51 0.30 0.50 0.20 0.28 0.32 0.36 0.38 0.42 0.45 0.47 0.50 0.51 0.30 0.24 0.28 0.32 0.35 0.39 0.42 0.44 0.47 0.49 0.10 0.21 0.25 0.29 0.32 0.36 0.39 0.42 0.45 0.48 0.00 0.00 0.00 0.18 0.22 0.26 0.28 0.32 0.35 0.37 0.40 0.42 FIGURES BASED ON 28W CORRECTED SWITCHSTART FITTING

High Frequency FHE54716-B-CL FHE54716-B-OP FHE54716-W-CL FHE54716-W-OP FHE54728-B-CL FHE54728-B-OP FHE54728-W-CL FHE54728-W-OP FHE54738-B-CL FHE54738-B-OP FHE54738-W-CL FHE54738-W-OP TROJAN SQUARE 2D 16W BLACK CLEAR HF TROJAN SQUARE 2D 16W BLACK OPAL HF TROJAN SQUARE 2D 16W WHITE CLEAR HF TROJAN SQUARE 2D 16W WHITE OPAL HF TROJAN SQUARE 2D 28W BLACK CLEAR HF TROJAN SQUARE 2D 28W BLACK OPAL HF TROJAN SQUARE 2D 28W WHITE CLEAR HF TROJAN SQUARE 2D 28W WHITE OPAL HF TROJAN SQUARE 2D 38W BLACK CLEAR HF TROJAN SQUARE 2D 38W BLACK OPAL HF TROJAN SQUARE 2D 38W WHITE CLEAR HF TROJAN SQUARE 2D 38W WHITE OPAL HF Emergency Maintained FHE54716-B-CL-EM FHE54716-B-OP-EM FHE54716-W-CL-EM FHE54716-W-OP-EM FHE54728-B-CL-EM FHE54728-B-OP-EM FHE54728-W-CL-EM FHE54728-W-OP-EM TROJAN SQUARE 2D 16W BLACK CLEAR EM TROJAN SQUARE 2D 16W BLACK OPAL EM TROJAN SQUARE 2D 16W WHITE CLEAR EM TROJAN SQUARE 2D 16W WHITE OPAL EM TROJAN SQUARE 2D 28W BLACK CLEAR EM TROJAN SQUARE 2D 28W BLACK OPAL EM TROJAN SQUARE 2D 28W WHITE CLEAR EM TROJAN SQUARE 2D 28W WHITE OPAL EM