Owners Manual. Features

Similar documents
Owners Manual. Features

Owner s Manual. Features

Installation and Operating Instructions

Installation and Operating Instructions

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

MODEL 233P/111P/233P-1.5

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

MODEL 422 Submersible Pump Controller

HP Volts Stages Discharge Head Length Brand S10P4HS /2 6 S10P4HS / " Sta-Rite S10P4HS Stainless Steel

CONSTANT PRESSURE CONTROLLERS

Electronic Products ELECTRONIC MAINTENANCE

ADVANCED PID TROUBLESHOOTING

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

REVISION HISTORY REVISION HISTORY

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

3 Phase Smart Controller

4" Motors and Controls

Commander Pro Variable Speed Controller System Instructions

Application Engineering

SOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual

CONSTANT PRESSURE CONTROLLERS

Commander Pro Variable Speed Controller System Instructions

Submersible Pumps. 5'' CS Series Pumps

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control

FHOTON Drive. Installation Guide

franklinwater.com 50 Hz 6" STS SERIES Submersible Turbine Pumps

4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP. "GS" series. "ST" series. "SL" series. ST Series (stainless steel) SL Series (thermoplastic)

Application Engineering

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

PPC3 & PPC5. State-of-the-art pump protection and controllers

E Series CE Approved Intermittent Pilot Ignition Control

Product Guide: Series III Pump Control Board Set (RoHS)

Easy touch Pump Control

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Franklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service

KD LV Motor Protection Relay

Flow-Thru Expansion Tanks

SOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

BrAC Audit Lock-1 Instruction User Manual

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

INSTRUCTION MANUAL IM260 AQUAVAR SOLO 2 CONSTANT PRESSURE CONTROLLER INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

CONTROLLER DIAGNOSTIC GUIDE

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

TRIPS AND FAULT FINDING

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR!

AL-KO ESC USER MANUAL

TDX - Taco Duplex Starter with

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

User Manual Solar Charge Controller 3KW

316 Stainless Steel Submersible Pumps 8" 10" 12"

ACCESSORY KIT INSTALLATION INSTRUCTIONS

SubDrive75/100/150/300 MonoDrive, MonoDriveXT

Application Engineering Europe

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation

Submittal Data Information

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Boston Gear Ratiotrol

Table of Contents. 4 Submersible Pumps

Trouble Shooting Guide EWA, 3-phase (D2422)

franklinwater.com 50 Hz 4 SUBMERSIBLE PUMPS

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Pump controller and protection for one pump Multicontrol. +info: INSTALLATION AND OPERATION. Mod. Vigilec mini (V1N)

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

PHOENIX Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

COPYRIGHT INFORMATION

R & D SPECIALTIES ROTROL I USER'S MANUAL

Fusesaver specification form

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

PHOENIX Features of the Phoenix-10 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Installation and Operating Instructions. Solar System Controller ISC3020

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

AeroVironment Universal Solar Pump Controllers

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual



User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

User Manual. Solar Charge Controller 3KW

Transcription:

Owners Manual Pumptec is a microcomputer based pump protection device that continuously monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Indicator lights provide complete system status, which can be easily viewed without removing the cover. Pumptec interrupts power to the motor whenever the motor load drops below a preset level or the load drops quickly. Pumptec is optimized to work with Franklin 2 & 3-wire single phase motors from 0.37 1/3 to - 1.1kW. 1-1/2 HP. An An underload (dry (dry well) adjustment is provided to address unusual situations. Features Protection Features Dry Well (Underload) Over & Under Voltage Rapid Cycle Bound Pump Indicator Lights Load Voltage Status Remote Control Features Over & Under Load Settings Over & Under Voltage Settings Reset Time Settings Fault History (Last 15 Faults) System Status Monitor Other Features Heavy Duty Relay 115V/230V 50/60Hz Operation Alarm Circuit Contacts

Technical Specifications: Model Number 5800020600 kw Horsepower Rating Rating 0.37 1/3 to - 1.1 1.5 Voltage Rating 115V/230V Frequency 50/60Hz Power Consumption 4W Response Time 3 Seconds Reset Time 2 to 120. (240. w/remote) Type Single Phase Induction Run Alarm Contact Rating 1 Amp 115V/230V Over/Under Voltage Time-out 2 utes Operating Temperature Range -15ºF to 130ºF Note: Pumptec is not designed for use on permanent split capacitor (PSC) motors. Dry well protection occurs when pump suction is broken. Deadhead conditions may not always be detected due to variation in pump load characteristics Installation Instructions 1. Remove the cover from the Pumptec. 2. If you will be running a 1.5HP 1.1kW motor, move the circuit board jumper to the 1.1kW 1.5HP position as shown in Figure 1. More 70% Sensitive 80% 60% 90% 40% Underload Trip %SFL 30 60 15 120 2 Timeout 1/3HP 1HP 1 HP (0.37 Setting - 1.1kW) Setting (Factory (Factory default) default) 1.5HP HP(1.1kW) Setting Figure 1: Circuit board jumper for 1.5HP motors (1.1kW) motors 2

3. Mount the unit in a location convenient for wiring. 4. Turn off power at the AC source. 5. Pumptec may be wired upstream or downstream of the control switch for 2-wire and 3-wire motors. Select an installation option from figures 2A and 2B. Pumptec Control Switch Pump Control Switch Pumptec Pump Figure 2A: 2-Wire Installation Options Pumptec Control Switch Control Box Pump Control Switch Pumptec Control Box Pump Figure 2B: 3-Wire Installation Options 3

6. Connect wires to the Pumptec as shown in Figure 3. Power is connected the same way regardless of the line voltage. Alarm Contacts Alarm Alarm (1 A Max.) 115V or 230V From power source or control switch Figure 3: Wiring Connections To 2-wire or 3-wire control box 7. Set the time-out adjustment to the desired position. The factory setting is 30 utes, see Figure 4*. More 60% 40% Sensitive 70% 80% 90% Underload Trip %SFL Underload sensitivity (Full clockwise for remote) Factory setting = 70% 15 2 30 Timeout 60 120 Reset time adjustment (Full clockwise for remote) Factory setting = 30 utes Figure 4: Timeout and Trip Sensitivity Settings 8. The factory underload setting of 70% should not require any adjustment. 4

9. Wire in alarm circuit, if desired. 10. Replace cover and secure cover screw. 11. Turn AC power back on. *Note: If you will be using IR remote control to set the underload and the time-out settings, set the appropriate adjustment knobs to the Remote position (fully clockwise position). See Figure 4. The initial remote settings are the same as the factory presets - 70% for underload and 30 utes for the underload timeout. The underload adjustment is preset at the factory to detect underload (dry well) conditions on most systems. In general, there is no need to adjust this setting. For more precise Control and Data Logging features, request the free software for your Palm/Pocket PC. 5

Operation Pumptec has three indicator lights labeled POWER, LOAD and VOLTAGE. If the Pumptec is connected upstream of the pressure switch, the system status can be detered from these indicator lights at any time. When wired down stream of the control switch, no status will be displayed when the control switch is open. Power Indicator Light If solid, the Pumptec has power and the system is idle. In this state, the motor is not running and the Pumptec is waiting for the control device (i.e. pressure switch) to close and turn on the motor. When flashing, the system is pumping water and running normally. Load Indicator Light When the load light is solid, a dry well (underload) condition has occurred. The Pumptec will wait the duration of the reset time-out period before attempting to restart the motor. A flashing load light t* indicates an an overload condition has occurred. The unit must be manually reset by by removing power for 10 10 seconds. An overload condition occurs when the motor current has become excessively high. Voltage Indicator Light When the voltage light is solid, an under voltage condition has been detected. The under voltage trip is factory preset to 203 volts. The remote control feature may be used to alter the under voltage trip point. When the voltage light is flashing, an over voltage fault has been detected. The over voltage trip is factory preset to 253 volts. The remote control feature may be used to alter the over voltage trip point. After a voltage fault has occurred, Pumptec will check the line voltage every two utes and will reset when the line voltage returns to the normal range. Load & Voltage Indicator Lights Flashing When both the load and voltage indicator lights are flashing together a Rapid Cycle condition has occurred. The Pumptec will reset after x utes. * (1/2 second on, 1/2 second off) 6

Troubleshooting Remote Control A Pocket PC with an infrared port may be used to monitor the motor/ pump system performance and adjust the Pumptec trip points. When dealing with unusual installations, the system monitor and underload adjustment remote control features allow quick diagnosis of system problems. No Lights No power is applied to the Pumptec. Check for voltage at the and connections. If Pumptec is wired downstream of the control switch, the control switch may be open. Solid Load Light Pumptec has detected a dry well or underload condition. A. Make sure the pump and motor are matched correctly. B. Check for a blocked pump intake or stuck check valve. C. The coupling between the motor & pump may be stripped. D. Blocked plumbing or stuck check valve may be causing a deadhead condition. E. The underload sensitivity knob may be adjusted in cases where the unit is too sensitive. After adjustment, check to insure the unit still is able to detect a dry well condition. Flashing Load Light* The system is drawing excessive current. A. The motor is stalled or there is a ground fault. Solid or Flashing Voltage Light The line voltage is too high or too low. A. An unloaded generator can cause a high line condition. B. Low line conditions can be caused by loose connections. C. Report persistent high or low line voltages to the power company. Flashing Voltage & Load Lights Rapid Cycle condition has occurred. A. Check for a waterlogged pressure tank. B. A bobbing float switch may cause rapid cycling. 7

Franklin Electric (Aust) Pty Ltd 106-110 Micro Circuit Dandenong South, Vic 3175 Tel: +61 3 9799 5000 Toll Free: 1300 FRANKLIN franklin-electric.com.au TOLL FREE HELP FROM A FRIEND Phone Franklin s toll-free Submersible SERVICE HOTLINE for answers to your installation questions. When you call, a Franklin expert will offer assistance in troubleshooting your pump protection system and provide immediate answers to your motor application questions. FE211 02/08