Installation Instructions

Similar documents
Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Wiring Diagrams DIAGRAM INDEX

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS DNLOWAMB015A00, DNLOWAMB016A00

Installation Instructions

Installation Instructions

Submersible Pumps Model ST4125D Model ST6125D

Installation Instructions

Installation Instructions

Wiring Diagrams (Including Accessories) (50/60 Hz)

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Installation Instructions Part Numbers: CRLOWAMB018A00 THROUGH CRLOWAMB026A00

Installation Instructions

Installation Instructions

Installation Instructions

Transformer Disconnects

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Installation Instructions

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Installation Instructions

Installation Instructions

Installing the PBX-PIT01 or PBX-PIT05 Pit Bar in the Ford Police Interceptor Utility

ELECTRICAL SYSTEM RP-7

ACCESSORY KIT INSTALLATION INSTRUCTIONS

IMPORTANT ATTENTION INSTALLERS:

Safety Message to Installers and Service Personnel of Emergency Vehicle Safety Equipment

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FORD SUPER DUTY NOTE: (Vehicle Retains Tow Hook) PART # P3064

Application Engineering

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER

CAUTION. SMALL ROOFTOP UNITS ACCESSORY ELECTRIC HEATER AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to15TONS TABLE OF CONTENTS !

Cleaning Flooded Gear

Installation Instructions

P80074 (150 amp connectors) P80071 (300 amp connectors)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

INSTALLATION INSTRUCTIONS PARTS LIST INSTALLATION INSTRUCTIONS AIR CONTROL KIT (800A0168 OR 800A0169)

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS

Installation Instructions for Replacement Mechanism Kit

Owner's/Installation Manual

GFK-210-C Blower System - Installation and Operating Instructions -

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

BL7000 SYSTEM OPERATING MANUAL

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR JET JLX SERIES LED LIGHT BARS

Installation Instructions

Application Engineering

Installing the PBX04 Push Bumper on the 2015 Chevrolet Suburban/Tahoe

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

INSTRUCTION, TRAIL CHARGER KIT P/N

Installation Instructions For Motor Control Center (MCC) Units

ACCESSORY KIT INSTALLATION INSTRUCTIONS

On-Board Battery Charger Kit

LED Downlight Ceiling Fixtures

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions for TLC79DCA Toyota Landcruiser VDJ79 Series 90lt Auxiliary Tank

Installation Instructions

Reproduction. Not for ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM

INSTALLATION INSTRUCTIONS Dodge Ram Crew / Mega 2500/3500 2/4WD NOTE: (tow hooks will not be re-attached) PART # P5056

SECTION PANELBOARDS

Cleaning Flooded Gear

Measurements are expressed in millimeters.

INSTALLATION INSTRUCTIONS

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

Model Parts Guide. CAUTION: Read the instructions before using the appliance!

LOADHOG BATTERY CHARGER

OWNER S MANUAL and TECHNICAL DOCUMENTATION

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

INSTALLATION INSTRUCTIONS

Pay For Water System DU 1A046A

Control Box Wiring For PRSstandard Tool

O & M Manual for the EATON Generator Ready Loadcenter

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

GENUINE PARTS INSTALLATION INSTRUCTIONS

Fog Light Bracket Assembly. Unpacking the Kit

MA-5200 Series MA-5300 Series

Installation Instructions

Installation Instructions

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Installation Instructions

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Transcription:

30RAP010-150, 38APS05-065, 38APD05-130 Ground-Fault Interrupter Convenience Outlet Accessory Installation Instructions Part No. 30RA-900---058, 30RA-900---059 SAFETY CONSIDERATIONS Installation of this accessory can be hazardous due to system pressures, electrical components, and equipment location (such as a roof or elevated structure). Only trained, qualified installers and service mechanics should install and service this equipment. When installing this accessory, observe precautions in the literature, labels attached to the equipment, and other safety precautions that apply. Follow all safety codes. Wear safety glasses and work gloves. Use care when handling and installing this accessory. WARNING Electrical shock can cause personal injury and death. Shut off all power to this equipment during installation. There may be more than one disconnect switch. Tag all disconnect locations to alert others not to restore power until work is completed. GENERAL The ground-fault circuit interrupter convenience outlet (GFI-CO) accessory provides two auxiliary 115 v, 60 Hz outlets for portable computers, lights, small hand tools and other devices. The current output is limited to 4 amps. See Table 1 for specific package applications. Table 1 Accessory Package Usage UNIT 30RAP010-150, 38APS05-065, 38APD05-130 (08/30, 30, 460 V) 30RAP010-150, 38APS05-065, 38APD05-130 (575 V) PACKAGE REQUIRED 30RA-900---058 30RA-900---059 Check each item for shipping damage. If any damage is found, file a claim with the shipping agent immediately. If any item is missing or if any part does not assemble properly, notify your Carrier representative. Table lists the contents of the accessory kits. Table Package Contents ACCESSORY PART NO. DESCRIPTION QTY Transformer/Convenience Outlet Assembly Assembly, 38APFSCLG--600 1 Screws, 1 / 4 -in. 1 / -in. long 4 30v: Primary fuse FNQ-R-3 1 / (FU5 and 30RA-900---058 FU6) 460v: Primary fuse FNQ-R- 1 / (FU5 and FU6) Secondary fuse FNM-6 (FU4) 1 Wire Ties 4 Transformer/Convenience Outlet Assembly Assembly, 38APFSCLG--100 1 30RA-900---059 Screws, 1 / 4 -in. 1 / -in. long 4 Primary fuse FNQ-R- 1 / (FU5 and FU6) Secondary fuse FNM-6 (FU4) 1 Wire Ties 4 INSTALLATION WARNING Before beginning installation of this equipment, be sure all power to the unit is disconnected, and that tags are properly placed to alert others. Electrical shock can cause personal injury and death. Sizes 30RAP010-030, 38APS,APD05-030 1. Open and tag all electrical disconnects.. Open the unit control box door. 3. Locate the bag of screws and fuses (30RA-900---058 only) supplied with the accessory. 4. Remove transformer box cover. Save screws. 5. Verify correct primary connections are made. NOTE: The 30RA-900---059 kits are shipped with correct wiring for 575 v. The 30RA-900---058 kits are shipped with correct wiring for 460 v. Operation at 08/ 30 v WILL require a wiring change and change of primary fuses to FNQ-R-3 1 /. See Table 3. Rejection type fuses are installed one way only. Make sure they are secure in the fuse holder clips. Table 3 Primary Connections VOLTAGE PRIMARY CONNECTIONS 575 V H1, H 460 V H1, H4 30 V H, H4 08 V H3, H4 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53300114-01 Printed in U.S.A. Form 30/38-13SI Pg 1 6-13 Replaces: 30RAP-4SI

6. Install the GFI-CO accessory box in the location shown in Fig. 1. Use the included sheet metal screws to fasten box to the basepan. 7. Using the screws removed in Step 4, reinstall the cover on the transformer box. 8. Route the power wire up and into the control box as shown in Fig.. Wire ties are supplied with the kit to secure the power wire. NOTE: For 30RAP010-030 units, more power wire is supplied than is needed. Excess wire length can be cut to length or bundled together and secured with wire ties. a30-5008 CONVENIENCE Fig. 1 Accessory Convenience Outlet Installation Location 30RAP010-030 (Shown), 38APS,APD05-030 Units a30-5009 CONVENIENCE Fig. Accessory Convenience Outlet Wire Routing 30RAP010-030 (Shown), 38APS,APD05-030 Units

9. In the control box, attach the black wire labeled 1 to the 11 connection on the A1 compressor contactor. Attach the black wire labeled to the 1 connection. Attach the green ground wire to the ground terminal in the control box. See Fig. 3. 10. Ensure that all electrical connections are tight and restore power to the unit. 11. Test the GFI-CO by pressing its Test button and checking for power at the outlet. If the accessory is incorrectly wired, the GFI-CO may not trip and power may be present at the outlet. If power is present, disconnect all power to the unit, correct the accessory wiring by reversing the power and neutral wires from the transformer to the outlet, reconnect the unit power and retest the outlet. See Fig. 4. 1. When the GFI-CO trips and no power is present at the outlet, restore the circuit by pressing the Reset button on the GFI-CO. 13. Remove tags from disconnects and close the control box door. NOTE: After the GFI-CO is installed, periodically test the ground fault feature as described in preceding Steps 11 and 1. NOTE: A knockout with protective bushing is supplied in the center post in order to run a power cord to the outside of the unit once the GFI-CO accessory is installed. When not in use, a plug button is supplied to plug the hole. Fig. 3 Accessory Convenience Outlet Control Box Wiring 30RAP010-030 (Shown), 38APS,APD05-030 Units ~ TRAN3 FU5 RED 1 H4 H3 H ~ FU5 BLK 1 HF H1 FU6 ~ FU4 X1 SECONDARY 115V X3 WHT XF BLK GFI-CO FIOP/ACCESSORY X1 LINE BRASS SCREW GRN-YEL RESET TEST LOAD SILVER SCREW VOLTAGE SERIES TERMINAL CONNECTIONS FOR PRIMARY SIDE TERMINAL CONNECTIONS FOR SECONDARY SIDE 575-3-60 100 H1-H XF-X 30-3-60 400,500 H-H4 XF-X 08-3-60 500 H3-H4 XF-X 460-3-60 600 H1-H4 XF-X Fig. 4 Accessory Convenience Outlet Wiring 3

Sizes 30RAP035-060, 38APS040,050, 38APD040-060 1. Open and tag all electrical disconnects.. Open the unit right control box door and remove inner cover. Remove lower right access panel and rear unit access panel. 3. Locate the bag of screws and fuses (30RA-900---058 only) supplied with the accessory. 4. Remove transformer box cover. Save screws. 5. Verify correct primary connections are made. NOTE: The 30RA-900---059 kits are shipped with correct wiring for 575 v. The 30RA-900---058 kits are shipped with correct wiring for 460 v. Operation at 08/ 30v WILL require a wiring change and change of primary fuses to FNQ-R-3 1 /. See Table 3. Rejection type fuses are installed one way only. Make sure they are secure in the fuse holder clips. 6. Install the GFI-CO accessory box in the location shown in Fig. 5. Use the included sheet metal screws to fasten box to the basepan. 7. Using the screws removed in Step 4, reinstall the cover on the transformer box. 8. Route the power wire up to the fan mounts and over and into the bottom of the right side of the control box as shown in Fig. 6. Wire ties are supplied with the kit to secure the power wire. 9. In the control box, attach the black wire labeled 1 to the 11 connection on the B1 compressor contactor. Attach the black wire labeled to the 1 connection. Attach the green ground wire to the ground terminal in the control box. See Fig. 7. 10. Ensure that all electrical connections are tight and restore power to the unit. 11. Test the GFI-CO by pressing its Test button and checking for power at the outlet. If the accessory is incorrectly wired, the GFI-CO may not trip and power may be present at the outlet. If power is present, disconnect all power to the unit, correct the accessory wiring by reversing the power and neutral wires from the transformer to the outlet, reconnect the unit power, and retest the outlet. See Fig. 4. 1. When the GFI-CO trips and no power is present at the outlet, restore the circuit by pressing the Reset button on the GFI-CO. 13. Remove tags from disconnects and close the control box door. NOTE: After the GFI-CO is installed, periodically test the ground fault feature as described in preceding Steps 11 and 1. NOTE: A knockout with protective bushing is supplied in the center post in order to run a power cord to the outside of the unit once the GFI-CO accessory is installed. When not in use, a plug button is supplied to plug the hole. CONVENIENCE a30-5011 Fig. 5 Accessory Convenience Outlet Installation Location 30RAP035-060 (Shown), 38APS040,050, 38APD040-060 Units 4

CONVENIENCE Fig. 6 Accessory Convenience Outlet Wire Routing 30RAP035-060 (Shown), 38APS040,050, 38APD040-060 Units Fig. 7 Accessory Convenience Outlet Control Box Wiring 30RAP035-060, 38APS040,050, 38APD040-060 Units 5

Sizes 30RAP070-150, 38APS065, 38APD070-130 9. In the control box, attach the black wire labeled 1 to the 11 connection on the B/B3 compressor contactor. Attach the black wire labeled to the 1 connection. Attach the green ground wire to the ground terminal in the control box. See Fig. 9. 10. Ensure that all electrical connections are tight and restore power to the unit. 11. Test the GFI-CO by pressing its Test button and checking for power at the outlet. If the accessory is incorrectly wired, the GFI-CO may not trip and power may be present at the outlet. If power is present, disconnect all power to the unit, correct the accessory wiring by reversing the power and neutral wires from the transformer to the outlet, reconnect the unit power, and retest the outlet. See Fig. 4. 1. When the GFI-CO trips and no power is present at the outlet, restore the circuit by pressing the Reset button on the GFI-CO. 13. Remove tags from disconnects and close the control box door. NOTE: After the GFI-CO is installed, periodically test the ground fault feature as described in preceding Steps 11 and 1. 1. Open and tag all electrical disconnects.. Open the unit middle control box door and remove inner cover. 3. Locate the bag of screws and fuses (30RA-900---058 only) supplied with the accessory. 4. Remove transformer box cover. Save screws. 5. Verify correct primary connections are made. NOTE: The 30RA-900---059 kits are shipped with correct wiring for 575 v. The 30RA-900---058 kits are shipped with correct wiring for 460 v. Operation at 08/ 30v WILL require a wiring change and change of primary fuses to FNQ-R-31/. See Table 3. Rejection type fuses are installed one way only. Make sure they are secure in the fuse holder clips. 6. Install the GFI-CO accessory box in the location shown in Fig. 8. Use the included sheet metal screws to fasten box to the base rail. 7. Using the screws removed in Step 4, reinstall the cover on the transformer box. 8. Route the power wire up and into the bottom of the right side of the control box as shown in Fig. 7. Wire ties are supplied with the kit to secure the power wire. CONVENIENCE Fig. 8 Accessory Convenience Outlet Installation Location/Wire Routing 30RAP070-150 (Shown), 38APS065, 38APD070-130 Units 6

B OR B3 Fig. 9 Accessory Convenience Outlet Control Box Wiring 30RAP070-150, 38APS065, 38APD070-130 Units 7

Carrier Corporation 013 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53300114-01 Printed in U.S.A. Form 30/38-13SI Pg 8 6-13 Replaces: 30RAP-4SI