TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS

Similar documents
TOUCH-ACTIVATED URINAL FLUSHING SYSTEM SLIM STYLE PANEL - LARGE (FRONT ACCESS)

flushing systems SMART CHOICES FOR HYGIENE AND WATER EFFICIENCY BUILT IN VANDAL RESISTANCE Toilet Flushing Systems Urinal Flushing Systems

HANDS FREE FOOT & KNEE OPERATED TAPWARE

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

ANTI VANDAL TAPWARE. Installation Instructions CONCEALED SPINDLE (CS) SERIES SCHOOL PATTERN (VP) SERIES TRADITIONAL/INSTITUTIONAL (IN) SERIES

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

ENWARE-ORAS SINGLE LEVER MIXER Installation and Maintenance Instructions

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

WC-Unit. Assembly instructions I00128_NOV 16

ENWARE-ORAS ELECTRONIC TAPWARE Installation and Maintenance Instructions

G SERIES - E TOUCH MIXER / TAP

Installation must be in Accordance with AS/NZS

Flush Valve Systems. By SCHELL.

Key Installation Points. Table of Contents

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

HIDEAWAY ACTIVE SENSOR-FLUSH URINAL

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Dolphin Blue Infrared Taps

INSTRS30709 rev 1 02/10/09 Page 1

INFRARED TAPS. Important: Electronic taps saving water, saving power, promoting hygiene DB100 DB125 DB150 DB175 DBL200 DBL225 DBL250 DBL275

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Bianco Rainsaver MK3 Installation and Operating Instructions. The no brainer. Bianco Rainsaver MK3 & MK3E Installation and Operating Instructions

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Bianco RainsaverMK4E Installation and Operating Instructions

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Damage caused by any improper treatment is not covered by the product warranty. Refer to Warranty Conditions.

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

Zip FlushMaster Surface mounted sensor

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

ROCA THE GAP BACK TO WALL TOILET SUITE

anti-vandal tapware ROBUST, EASY TO CLEAN VANDAL RESISTANCE FOR COMMERCIAL, INSTITUTIONAL AND PUBLIC USE

INSTALLATION & MAINTENANCE MODEL mm

CIRCLE SEAL CONTROLS

LAWN SPRINKLER, IRRIGATION PUMP

SHORTENING FILTER. Operating Instructions INSPECT CARTON SPECIFICATIONS PARTS. MODEL NO'S 102 & 107 CE Series

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

Zenith Aqua Sense Taps

Installation & Operation Manual

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation and Operation Instructions

485 - NC NO/DA DN

Installation & Operating Manual

INSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

Operation and Maintenance Instructions

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

APT10-2 Automatic Pump Trap

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

OPTIMUS SE-1200 SE-1250 SE-1255

Inverted High Pressure Fluid Filters

Automatic (Air Release) Air Valve

CIRCLE SEAL CONTROLS

Breezair TBA 550 Installation Manual

CHALLENGER Propane to Natural Gas Instructions

PNEUMATICALLY ACTUATED 2-WAY

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Operating Instructions & Parts Manual

POSITIVE DISPLACEMENT FLOWMETERS

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

PRODUCT OPERATING MANUAL

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

Easytork Solenoid Valve IOM

Basic Parts Description Size Page Stock No.

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

Installation Instructions

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

OWNER S TECHNICAL MANUAL

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

IOM IR-110-X. Solenoid Control Valve

Troubleshooting The Transmission Hydraulic System

DELUXE TELESCOPING LANCE ASSEMBLY

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

SERIES G3DB/AG3DB ELEVATOR

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

Troubleshooting the Transmission Hydraulic System

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Service Information System

Maintenance Information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Transcription:

TOUCH-ACTIVATED DUAL FLUSH WC FLUSHING SYSTEM - FRONT ACCESS Installation and Maintenance Instructions EMF411M I00004_Dec 17 Call 1300 369 273 www.enware.com.au Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph: +61 2 8556 4000 Fax: +61 2 8556 4055

Touch-Activated Dual Flush WC Flushing System - Front Access Enware s WC flushing systems provide a neat and reliable flushing solution using piezoelectric technology particularly suited for public access applications. Uses a WaterMarked solenoid that when combined with an appropriate pan delivers either a 3/6L or 3/4.5L flush. Larger style face plate allows for front access where remote access is not available. Stylish and strong electronic piezo operation using mains power. Designed to allow for full access to flushing components located behind the stainless panel. Stainless steel panel is secured with torx screws. Shut off valve, filter and airbreak included. EMF411M FEATURES Suitable for AS1428.1 applications Piezo touch button control 3 or 4 Star WELS rating* Mains power 24V Large face plate Vandal resistant torx screws 1-year warranty Product Codes EMF411M-3 EMF411M-4 WELS 3 Star rated* WELS 4 Star rated* Technical Information Water Supply 300 kpa Connection Inlet - 1 BSP (25mm) Minimum Water Supply Line Size Outlet - 1 ½ BSP (40mm) 1 (25mm) copper pipe 60 Mains Powered 24V AC transformer 41 85 70 4.5 m TRANSFORMER EXTENSION CABLE 1" BSP (MALE) 370 60 Kv Factor 8.3m³/h Flush Pipe 1½ (40mm) flush pipe is required below the air break. (Note: use a maximum of 1x90º bend in flush pipe. If an offset is required 2 x 45º bends must be used. Maximum of 1 offset per flush pipe. Air break must be installed in a vertical position at 700mm +/- 100 mm above the pan inlet. Pan 5.5L (6L) Capacity (1 star) Enware products must be installed in accordance with the provisions of AS/NZS3500 and any relevant local regulations. Installations not complying with AS/NZS3500 may void the product and performance warranty provisions. As Enware s product development is ongoing, product specifications may vary over time. * WELS volume is only achieved at 300kPa. Use a pressure limiting valve to achieve WELS rating when required. 330 95 The more stars the more water efficient WATER RATING www.waterrating.gov.au The more stars the more water efficient WATER RATING www.waterrating.gov.au 3.8 litres average flush 6 L per full flush / 3 L per half flush 3.1 litres average flush 4.5 L per full flush / 3 L per half flush 250 145 STAILNLESS STEEL SOLENOID DN40 FLUSH PIPE WMTS-020 C of C 40116 Global-Mark Version: Dec17 2 Call 1300 369 273 www.enware.com.au

installation instructions Before proceeding with installation ensure all operating & dimensional specifications are suitable for the intended installation. IMPORTANT TECHNICAL REQUIREMENTS To ensure that the unit works correctly, it is important to ensure that the site and location of installation meets the hydraulic requirements of AS/NZS 3500.1. Also there must be: Minimum 25mm copper supply line Minimum 200kPa for valve to operate. NOTE: WELS Volume only achieved at 300kPa 40mm flush pipe must be used (PVC adaptors to be supplied by the client if required) (See FIGURE 1.1) Only 1 x 90 bend in flush pipe (any other bends are required to be 45 - maximum of 2) 700mm ± 100mm Air break must be installed in a vertical position. Pipe work to the valve fixture must be sized according to water service rule calculations and simultaneous demand requirements. To ensure that the pipeline reticulation system for the valve is designed correctly for the satisfactory performance of the valve a Hydraulic services Consultant and/or Engineer (or other personnel appropriately qualified in hydraulic services design) must be engaged. DIMENSION SUPPLIED BY PAN MANUFACTURER 1.2 INSTALLATION INSTRUCTIONS 1. Separate all parts from packaging & check each part with contents section (refer Fig 2.1). Pay attention to the different models variations. Make sure all parts are accounted for before discarding any packaging material If any parts are missing, do not attempt to install your flushing system until missing parts are obtained. 2. Flush water supply lines thoroughly before installing the flush valve. Do not allow dirt, thread sealant or metal particles enter the unit. 3. Fit the flush valve in the required position (take note of installation guidelines). If using PVC flush pipe, a 40mm cap and lining must be fitted to the air break. (cap and lining not supplied) 4. Fix noggins in the correct position for facia plate bracket mounting. 5. Run conduit from solenoid valve to power supply and thread transformer wire through ( 2m extension lead available from Enware part No. EMDS801) 6. Turn water supply on and check for leaks. (note Ball Valve still in off position.) 7. Turn inlet ball valve on and check for leaks (make sure the solenoid is not connected to power) FIGURE 1.1 FIGURE 1.2 350-355 230-232 FIGURE 1.3 www.enware.com.au Call 1300 369 273 3

8. When the wall is fitted, allow 230mmx350mm cut out for facia plate fixing. 9. Fit the piezo button to the stainless steel cover plate. Ensure red fibre washer is used. Take note of the half flush tag and full flush tag at the back of the piezo. (FIGURE 1.5) FIGURE 1.4 2 10. Piezo cable connection Locate the positive wire from each piezo (indicated by the black strip on the wire). Plug both positive spade connectors into one side of the solenoid. Locate the two remaining negative wires and plug into the other side of the solenoid. (FIGURE 1.6) 11. Connect power Plug the transformer lead in to the female socket connection on the Full Flush button cable. This will leave one male connector on the Full Flush cable. Plug this male connector in to the female connector on the Half Flush button cable.(2m extension available if required - EMDS801) (FIGURE 1.7) FIGURE 1.5 FIGURE 1.6 1 FIGURE 1.7 12. Fit mounting bracket with in wall cavity. 13. Fit stainless steel face plate with piezo to the mounting bracket in wall (FIGURE 1.8) 14. Turn on shut off valve and transformer. Test system. FIGURE 1.8 4 Call 1300 369 273 www.enware.com.au

product components Securing Screws Stainless Steel Face Plate Mounting Bracket 1-3/4 connection nipple Y Body Shut Off Valve and Strainer Connection Nipple Union Red Fibre Washer Piezo Double Adaptors Solenoid Air Break Piezo Button Trap Nut with Rubber Olive 24V Transformer - 1.8M Lead spare parts SPARE PARTS EMDS800 24V Transformer - 1.8M Lead EMFS301 Swith Piezo 22mm Fixed Half Flush EMFS302 Swith Piezo 22mm Fixed Full Flush EMFS303 Solenoid 3/4 24V AC EMFS307 Spade Connector Piezo Dual Flush EMFS306 Rubber Olive EMFS308 Y Body - Shut off valve and strainer OPTIONAL PART EMDS801 2m Power to piezo extension lead www.enware.com.au Call 1300 369 273 5

service and maintenance FILTER CLEANING This flush valve is provided with a stainless steel filter preventing foreign particles from entering the lines. If the water flow has decreased, this may be because the filter is clogged. They can be cleaned as follows: 1. Turn-off the water shut off valve 2. Open the filter cap on the Y body, directly below shut off valve 3. Remove the filter and wash it under running water. It may be necessary to replace the filter (spare parts can be ordered from Enware) 4. Reinsert the filter and refit the filter cap 6. Turn on the water shut off valve 7. Make sure that there is no leakage SERVICE INSTRUCTIONS Refer to trouble shooting chart to help determine specific problems. Complete service instructions are supplied with each spare part kit and these should always be referred to before disassembling any fitting. Spare part kits should be on hand before any complete service of the tap is undertaken. 6 Call 1300 369 273 www.enware.com.au

trouble shooting Refer to the following trouble shooting chart for specific problems and solutions. Service instructions are supplied with spare part kits PROBLEM CAUSE RECTIFICATION Button pressed - water does not flow Loose connection on leads Reconnect electrical connections Piezo switch is not working Piezo switch or transformer faulty Dirty Filter Refer to 3.1 Filter Cleaning on page 6. Supply pressure issue Ensure pressure delivered to unit is above 200kpa and below 500kPa (dynamic) Water does not stop flowing Debris or scale in the solenoid Remove solenoid, pull out plunger and spring & clean them. Use scale remover if required. When replacing plunger, ensure spring is in vertical position Dirty Filter Refer to 3.1 Filter Cleaning on page 6. Supply pressure issue Ensure pressure delivered to unit is above 200kpa and below 500kPa (dynamic) Flush pattern not fully covering bowl Supply pressure issue Ensure pressure delivered to unit is above 200kpa and below 500kPa (dynamic) Supply pipe inadequate size Pan water requirements not met by flushing mechanism Ensure supply is 25mm (minimum) Refer to pan manufacturers instructions. If pan is 6/3L style,look at supply pressure issues. Otherwise replace pans with 6/3L style Too little water delivered Supply pressure issue Ensure pressure delivered to unit is above 200kpa and below 500kPa (dynamic) Supply pipe inadequate size Pan water requirements not met by flushing mechanism Ensure supply is 25mm (minimum) Refer to pan manufacturers instructions. If pan is 6/3L style,look at supply pressure issues. Otherwise replace pans with 6/3L style www.enware.com.au Call 1300 369 273 7