Executive Order G F

Similar documents
State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-204-U. Relating to Certification of Vapor Recovery Systems

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B

New Amendment to Executive Orders VR-203-N & VR-204-N

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-301-B

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-209-A

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer. Exhibit 2 System Specifications

Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements

4. No person shall install a coaxial Phase I vapor recovery system unless the system was certified by CARB after January 1, 1994.

State of New Jersey. Department of Environmental Protection Air Quality Permitting

State of California AIR RESOURCES BOARD EXECUTIVE ORDER NVR-1-C. Relating to Certification of Non-Vapor Recovery Hoses

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

REGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.

FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300 must accompany this application.

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

TRANSFER OF ORGANIC COMPOUNDS INTO MOBILE TRANSPORT TANKS (Effect: 5/6/77: Rev. Effect. 7/26/00)

The purpose of this rule is to limit emissions of gasoline vapors from the transfer of gasoline into motor vehicle fuel tanks.

UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks

State of New Jersey. Department of Environmental Protection Air Quality Permitting. General Permit (GP-004A) For FUEL DISPENSING FACILITIES

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

Executive Orders VR-203-F and VR-204-F VST Phase II EVR System. Exhibit 5 Liquid Removal Test Procedure

State of California AIR RESOURCES BOARD EXECUTIVE ORDER DE

APPENDIX B. DYNAMIC PRESSURE PERFORMANCE TEST (taken from BAAQMD test procedure ST-27)

TRANSFER OF GASOLINE FROM STATIONARY UNDERGROUND STORAGE TANKS INTO VEHICLE FUEL TANKS (Effect. 03/01/06: Rev. 03/26/08)

Ohio EPA. Division of Air Pollution Control. Engineering Guide #12

Executive Order VR-205-B VST Phase II EVR System with Hirt Thermal Oxidizer

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

San Joaquin Valley Unified Air Pollution Control District

Code Requirements on Aboveground Storage Tanks Dispensing Fuels At Motor Vehicle Fuel-Dispensing Stations

The purpose of this rule is to limit VOC emissions from the transfer of organic liquids.

State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-203-F

ORDINANCE NO WHEREAS, the City Council wishes to advance the use of electric vehicles; and

EVR Hose Configuration

San Joaquin Valley Unified Air Pollution Control District Permit Services Division

CITY COUNCIL OF THE CITY OF NOVATO ORDINANCE NO. 1620

San Joaquin Valley Unified Air Pollution Control District

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

Fire & Rescue District

INSTALLATION INSTRUCTIONS

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

Greater Vancouver Regional District Gasoline Distribution Emission Regulation Bylaw No. 1085, 2008

Chapter 17 TRAFFIC AND VEHICLES. Adoption of Uniform Rules of the Road. Temporary Traffic Regulations.

ERIC S. CASHER, CITY ATTORNEY WINSTON RHODES, AICP, PLANNING MANAGER

HOUSE BILL NO. HB0235. Sponsored by: Representative(s) Roscoe and Miller A BILL. for. AN ACT relating to motor vehicles; providing that the

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

Imperial County Air Pollution Control District Rule 415

Phase I Clean Fuel Vehicle Emission Standards for Light-Duty Trucks of up to 3,750 Lbs. LVW and up to 6,000 Lbs. GVWR and Light-Duty Vehicles

TOWN OF BRIDGTON TRAFFIC ORDINANCE

REGULATION II PROHIBITIONS

State of California ALIR RESOURCRS BOARD. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

City of San Juan Capistrano Agenda Report

ORDINANCE NO AN ORDINANCE REGULATING SPECIAL VEHICLES. The City Council of the City of Cokato, Minnesota hereby ordains as follows:

CHAPTER 1-7 ARTICLE V AN ORDINANCE PERMITTING AND REGULATING THE OPERATION OF GOLF CARTS ON PUBLIC STREETS

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

ADOPTION OF AN ORDINANCE ADDING SECTION TO THE NOVATO MUNICIPAL CODE PROHIBITING THE PARKING OF RV S ON PUBLIC STREETS WITHOUT A PERMIT

Testing Requirements for UST s and AST s. By Mark Lindsey June 27 th, 2013

CHAPTER 77: MOTORIZED GOLF CART AND MINI TRUCK USE ON ROADWAYS

2016 California Green Building Standards Code (CALGreen)

Grant Guidelines To States For Implementing The Secondary Containment Provision Of The Energy Policy Act Of 2005

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. New Jersey Fuel Dispensing Facilities Compliance Calendar

Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer

Title V. Model General Permit Template. SERIES 18 Tanks. Template # SJV-TK

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

CARL MOYER MEMORIAL AIR QUALITY STANDARDS ATTAINMENT PROGRAM OFF-ROAD COMPRESSION-IGNITION (CI) APPLICATION

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

E. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)

State of California AIR RESOURCES BOARD. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

SOLID WASTE MANAGEMENT ORDINANCE FOR THE TOWN OF HUDSON, MAINE

Fuels Safety Division. Propane Code Adoption Document Amendment

State of California AIR RESOURCES BOARD. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code

State of California AIR RESOURCES BOARQ. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code

CITY OF SALEM, ILLINOIS ALTERNATIVE TRANSPORTATION APPLICATION AND INSPECTION REPORT (GOLF CARS) Applicant Name:

Georgia Drycleaner Compliance Calendar

1) Activity Description: Management of Petroleum Storage Tanks and Containers

40 CFR 63, Subpart CCCCCC

RE: FINAL PERMIT TO INSTALL CERTIFIED MAIL BUTLER COUNTY Application No:

CITY OF ST. CLAIR ORDINANCE CODE. CHAPTER 77: ALL-TERRAIN VEHICLES (ATV s), MINI-TRUCKS, AND MOTORIZED GOLF CARTS

2019 Air Quality Compliance Calendar for Gasoline Dispensing Facilities General 5 - AQGP-022 Lane County, Oregon

VILLAGE OF PALESTINE, ILLINOIS ORDINANCE NO O- /O

State of California AIR RESQURCES BOARD. EXECUTIVE ORDER D Relating to Exemptions Under Section of the Vehicle Code

CITY OF ALTAMONT ALTAMONT, ILLINOIS ORDINANCE NO

TO BE RESCINDED. 1301: Motor fuel-dispensing facilities and repair garages.

TRANSFER FLOW INCORPORATED INSTRUCTION SHEET NUMBER 374 IS DEPARTMENT OF TRANSPORTATION SPECIAL PERMIT SP

These regulations are created pursuant to and of the Colorado Revised Statutes.

State of California AIR RESOURCES BOARD. EXECU1-IVE ORDER D Relating to Exerr~ptions under Section of the Vehicle Code

Pennsylvania DEP Aboveground Storage Tank Facility Visits NISTM PA CONFERENCE Washington, PA May 18, 2017

State of California AIR RESOURCES BOARD. EXECUTIVE ORDER D Relating to Exemptions under Section of the Vehicle Code

City of San Juan Capistrano Agenda Repo_rt

ORDINANCE This ordinance is adopted pursuant to Section Florida Statutes.

1 [Building Code - Electric Vehicle Charging Stations - Expedited Permit Process]

CHAPTER 403. HAZARDOUS MATERIAL TRANSPORTATION

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Franklin Fueling Systems

RESOLUTION NO. Date Passed: November 14, 2016 ESTABLISHING CITY OF ROCHELLE WATER RATES, EFFECTIVE JULY 1, 2017

Transcription:

State of California AIR RESOURCES BOARD Executive Order G-70-116-F Certification of ConVault, Inc. Aboveground Filling/Dispensing Vapor Recovery System WHEREAS, the Air Resources Board (the "Board") has established, pursuant to California Health and Safety Code Sections 39600, 39601 and 41954, certification procedures for systems designed to control gasoline vapor emissions displaced during the filling of service station storage tanks ("Phase I vapor recovery systems") and for systems designed to control gasoline vapor emissions from motor vehicle fueling operations ("Phase II vapor recovery systems") in its "Certification Procedures for Gasoline Vapor Recovery Systems at Service Stations", amended December 4,1981 (the "Certification Procedures"), and incorporated by reference in Title 17, California Code of Regulations, Section 94001; WHEREAS, the Board has established, pursuant to California Health and Safety Code Sections 39600, 39601, and 41954, test procedures to determine compliance of Phase I and Phase II vapor recovery systems with emission standards in its "Test Procedures for Determining the Efficiency of Gasoline Vapor Recovery Systems at Service Stations", amended September 1, 1982 (the "Test Procedures"), incorporated by reference in Title 17, California Code of Regulations, Section 94000; WHEREAS, ConVault, Inc. systems have been previously certified for Phase I and Phase II vapor recovery for single and split product tanks in sizes varying from 250 to 12,000 gallons and painted white. WHEREAS, ConVault, Inc. has requested certification for tanks with an exposed aggregate surface on the sides, a brushed concrete surface on the top and painted with a clearcoat finish. WHEREAS, the Con Vault, Inc. exposed aggregate tank vapor recovery system has been evaluated pursuant to the Certification Procedures and Test Procedures; WHEREAS, Section VIII-A of the Certification Procedures provides that the Executive Officer shall issue an order of certification if he or she determines that a vapor recovery system conforms to all of the requirements set forth in Certification Procedures Sections I through VII; and WHEREAS, on April 15, 1994 the Air Resources Board Executive Officer, pursuant to California Health and Safety Code sections 39515 and 39516, delegated to the Chief, Compliance Division full authority to approve and grant Executive Orders certifying integral Phase I and Phase II aboveground systems in accordance with California Health and Safety Code section 41954; and WHEREAS, I, James J. Morgester, Chief of the Compliance Division of the California Air Resources Board, have determined that the ConVault, Inc. aboveground storage vapor recovery systems, when used with ARB Certified Phase I two-point balance vapor recovery components and Phase II balance vapor recovery components, conforms with all the requirements set forth in Sections I through VII of the Certification Procedures;

Executive Order G-70-116-F Page 2 of 3 NOW, THEREFORE, IT IS HEREBY ORDERED that this certification applies to the ConVault, Inc. aboveground gasoline storage vapor recovery systems. The systems certified by this order may be used on single or split product rectangular tanks between 250 and 12,000 gallons total capacity which utilize the same geometric configuration and design as shown in Exhibits 1 and 2 (attached). IT IS FURTHER ORDERED that any emergency vent and manway installed on the tanks be leak free at the operating pressure of the tank when tested in accordance with ARB test methods, as specified in Title 17, California Code of Regulations. IT IS FURTHER ORDERED that the use of Air Resources Board certified Phase I two-point balance system vapor recovery components and Phase II balance system vapor recovery components shall be a condition of the certification. Air Resources Board certified Phase I components are listed in Exhibits 1 through 3 of Executive Order G-70-97-A, Exhibits 1 and 2 of Executive Order G-70-102-A, or Exhibits 1 and 2 of Executive Order G-70-142-A. Air Resources Board certified balance system Phase II components are listed in Executive Order G-70-52-AM and other G-70 series. IT IS FURTHER ORDERED that the Phase I two-point balance system components and piping configuration used to connect the cargo truck bulk delivery line and vapor return line to the storage tank fill line and vapor recovery line shall be consistent with Air Resources Board Executive Order G-70-97 series, G-70-102 series or Executive Order G-70-142 series and that any liquid leak upon disconnecting the delivery line shall be no more than 10 ml per disconnect computed from the average of three disconnect operations. IT IS FURTHER ORDERED that in order to prevent spitback or condensate from blocking the vapor path between the vehicle fill pipe and the storage tank headspace, the routing of the coaxial hose shall be consistent with the configurations shown in exhibits 4 through 11a in Air Resources Board Executive Order G-70-52-AM, with the exception that the highest point in the vapor return path must be above the top of the storage tank and there shall be no liquid trap in the vapor path between the highest point in the vapor return path and the storage tank vapor headspace during fuel dispensing. Furthermore, there shall be no liquid trap in the vapor path between the vehicle fill pipe and the highest point in the vapor return path during fuel dispensing unless the coaxial hose is equipped with a liquid removal system with the liquid pickup located at the liquid trap. IT IS FURTHER ORDERED that an Air Resources Board certified P/V valve shall be installed on the tank vent and that the valve have a rated pressure relief setting of no more than 2.5 inches of water column gage. The installed P/V valve shall extend to a minimum height of 12 feet above grade. IT IS FURTHER ORDERED that a minimum of 6 inches of concrete insulating material be installed between the interior holding tank and the exterior containment tank for all storage tanks as shown in Exhibits 1 and 2. IT IS FURTHER ORDERED that the general exterior of the storage tanks be painted white; or, constructed with an exposed aggregate surface on the sides, a brushed concrete top surface, and painted with a clear coat finish.

Executive Order G-70-116-F Page 3 of 3 IT IS FURTHER ORDERED that compliance with the rules and regulations of the local air pollution control district with jurisdiction over the location where the system is installed, shall be made a condition of this certification. IT IS FURTHER ORDERED that when bulk deliveries are being made by a cargo truck, rather than a bobtail truck, the truck pumping system be operated at a steady rate to limit the amount of vapor growth associated with a varied pumping rate. When clearing fuel from the pumping system, following fuel delivery, the operator shall likewise maintain a steady pumping rate. IT IS FURTHER ORDERED that prior to using any ConVault, Inc. aboveground system for storage of gasoline the complete vapor recovery system will be leak checked at 150 percent of the maximum working pressure of the tank (P/V valve setting), or 5 inches of water column pressure, whichever is greater, and verified to be vapor tight. Thereafter, the complete system shall be checked once a year to ensure a vapor tight system and proper operation of the vapor recovery system. Leak checks shall be conducted in accordance with ARB test methods, as specified in Title 17, California Code of Regulations. IT IS FURTHER ORDERED that the tank and associated piping and other equipment not specifically listed as approved Phase I equipment in Exhibits 1 through 3 of Executive Order G-70-97-A, Executive Order G-70-102 series or G-70-142 series nor specifically listed as approved Phase II equipment in Executive Order G-70 series shall comply with the rules and regulations of the local fire officials with jurisdiction over the location where the system is installed. IT IS FURTHER ORDERED that compliance with all applicable certification requirements and rules and regulations of the Division of Measurement Standards, the Office of the State Fire Marshal, and the Division of Occupational Safety and Health of the Department of Industrial Relations shall be made a condition of this certification. IT IS FURTHER ORDERED that any alteration of the equipment, parts, design, or operation of the configurations certified hereby, is prohibited, and deemed inconsistent with this certification, unless such alteration has been approved by the Executive Officer or his or her designee. IT IS FURTHER ORDERED that this Executive Order shall supersede EO G-70-116-E dated April 1, 1995. Executed this day of November 1995 at Sacramento, California. James J. Morgester, Chief Compliance Division

Exhibit 2 Executive Order G-70-116-F ConVault, Incorporated Aboveground Tank Filling/Dispensing Vapor Recovery System Tank Dimensions TOTAL CAPACITY (GAL.) LENGTH HEIGHT WIDTH 250 7 8 3 3 3 9 500 11 0 3 4 4 6 DOUBLE 500 11 0 4 4 5 8 1000 11 0 4 4 5 8 DOUBLE 1000 11 3 5 6 8 0 2000 11 3 5 6 8 0 4000 17 7 ½ 6 5 ¾ 8 0 5200 13 0 7 0 11 11 6000 17 7 ½ 8 9 ¾ 8 ½ 8000 23 1 ½ 8 9 ¾ 8 ½ 10000 28 7 ½ 8 9 ¾ 8 ½ 12000 34 1 ½ 8 9 ¾ 8 ½