Operating instructions Flow monitors SI / / 2010

Similar documents
Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Operating instructions Flow monitor SI / / 2013

Operating instructions Flow monitor SI / / 2014

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

Operating instructions Binary level sensor. LI214x /00 04/2016

Operating instructions Mechatronic flow sensor SBY /00 03/2011

Operating instructions Binary level sensor LMT /00 06/2011

Electronic pressure switch with integrated analogue output

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

Electronic pressure switch with two switching outputs

Installation instructions BasicRelay CR / / 2012

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

ZB0050 / ZB0051 ZB0070 / ZB0071

DEVICE STATE/BYPASSED FAILURE OVERLOAD

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

MINI MCR-SL-UI-UI(-SP)

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Technical Documentation

BODAS Pressure sensor PR3 series 10

Electronic Circuit Breaker ESS20-0..

Electronic Pressure Switch EDS 3000

MINI MCR-SL-UI-UI(-SP)(-NC)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

JUMO MIDAS S05 Pressure transmitter Type

SG-B1 SERIES / SG-A1 SERIES

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Surface mounting, flush mounting, and DIN track mounting

DC/DC converters - MINI-PS DC/ 5-15DC/

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Innovation in pressure sensing Simple-to-set compact electronic pressure switches. Pressure switches

SA1W: Water Detection Sensors

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Electronic Circuit Breaker ESS20

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

FPT Applications. Features

G72x Series Direct Spark Ignition Controls

Bulletin 825 SMM Smart Motor Manager

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Thermal flow sensor TFS-35

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal-Magnetic Circuit Breaker M1-...

KD LV Motor Protection Relay

SIRIUS 3RU2 Thermal Overload Relays

For air dampers and control valves of oil or gas burners

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Electronic timers CT-E range Selection and ordering details

Differential Pressure Sensors

Thermal flow sensor TFS-35

Operation Instructions

Electronic Pressure Switches

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Thermal Overcurrent Circuit Breaker 3120-F...

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Angle sensor AN2 series 30

Thermal Overcurrent Circuit Breaker 3120-F...

Temperature Controller (Heat Pumps)

Pressure Sensors. for liquid and gaseous media

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Type A-10 General Purpose Pressure Transmitters

Magnetic and Hydraulic-Magnetic Circuit Breaker

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

TURBOTRONIK NT 151/361

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

Pressure regulators E/P pressure regulators Series ED02. Brochure

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Thermal Overcurrent Circuit Breaker 3120-F...

Technical Datasheet P-30/P-31. Standard transmitter.

better measurement Simply a question of

c-go 24V/6A 24V/8A 24V/12A

Differential Pressure Sensors

BODAS Pressure sensor PR3 series 10

Transcription:

Operating instructions Flow monitors SI5004 UK 704339 / 02 08 / 2010

Contents 1 Safety instructions 3 2 Functions and features 4 2.1 Application area 4 2.2 Operating principle flow monitoring 4 3 Installation 5 3.1 Installation location 5 3.2 Sources of interference in the pipe system 6 3.3. Mounting operation 6 4 Electrical connection 7 5 Operating and display elements 7 6 Set-up and settings for water 8 6.1 High flow adjustment (optional) 8 7 Additional settings (optional) 9 7.1 Low flow adjustment 9 7.2 Restore the factory setting (reset) 9 7.3 Lock / unlock the unit 9 8 Error during adjustment 10 9 Operation 10 10 Maintenance 11 11 Scale drawing 11 12 Technical data 12 2

Preliminary note An instruction is indicated by : Example: Check whether the unit operates correctly. A reaction to the action is indicated by ">": Example: > LED 9 lights. 1 Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. The unit conforms to the relevant regulations and EC directives. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. For the scope of validity culus: The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the following table. UK Overcurrent protection Control-circuit wire size Maximum protective device rating AWG (mm 2 ) Ampere 26 (0.13) 1 24 (0.20) 2 22 (0.32) 3 20 (0.52) 5 18 (0.82) 7 16 (1.3) 10 3

2 Functions and features 2.1 Application area The unit monitors the flow of liquid media. 2.2 Operating principle flow monitoring The unit detects the flow speed to the calorimetric measuring principle and converts it into an analog output signal (4...20 ma). The output signal corresponds to the characteristic curve of the sensor. Like the row of LEDs it indicates the relative flow velocity within the detection range set. In case of excess flow (flow velocity exceeds the detection range) the output signal increases to 20...22 ma. B C A: operation display (row of LEDs) B: flow velocity C: characteristic curve D: sensor signal E: output signal in ma A 0 D E 22,0 20,0 18,4 16,8 15,2 13,6 12,0 10,4 8,8 7,2 5,6 4,0 The unit is delivered with the following factory setting: monitoring range = 5...100 cm/s in water. The typical response time of the unit is 1...10 s. 4

3 Installation Using process adapters the unit can be adapted to different process connections. Adapters have to be ordered separately as accessories. A correct fit of the unit and ingress resistance of the connection are only ensured using ifm adapters. For small flow rates ifm adapter blocks are available. 3.1 Installation location General The sensor tip is to be completely surrounded by the medium. Insertion depth of the sensor: minimum 12 mm. 12mm UK Recommended For horizontal pipes: mounting from the side. For vertical pipes: mounting in the rising pipe. Conditional Horizontal pipe /mounting from the bottom: if the pipe is free from build-up. Horizontal pipe /mounting from the top: if the pipe is completely filled with medium. To avoid The sensor tip must not be in contact with the pipe wall. Do not mount in downpipes that are open at the bottom! 5

Low Flow Setpoint High Low Flow Setpoint High 3.2 Sources of interference in the pipe system Components integrated in the pipes, bends, valves, reductions, etc. lead to turbulence of the medium. This affects the function of the unit. Recommendation: Adhere to the distances between sensor and sources of interference: 5...10 x D 3...5 x D S S D = pipe diameter; S = sources of interference 3.3. Mounting operation Ensure that the system is free of pressure during installation. Ensure that no media can leak at the mounting location during installation. 1 2 3 A í ì î Grease the threads of the process connection (1), adapter (2) and nut (3). Note: The sensor tip (A) must not be in contact with grease. Screw the suitable adapter into the process connection. Place the flow monitor onto the adapter and tighten the nut. Tightening torque 25 Nm. Ensure that the unit is correctly oriented. 6

4 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: 2 3 1 1 BN 4 2 WH L+ n.c. UK 4 3 BU L Core colours of ifm sockets: 1 = BN (brown), 2 = WH (white), 3 = BU (blue) n.c. = not connected 5 Operating and display elements 1 Low Flow Scale High 2 3 1: Operation display The green LEDs indicate the current flow (the LEDs 0 to 9 represent the range between no flow and maximum flow). 2, 3: Setting buttons for adjustment 7

6 Set-up and settings for water (For media other than water 7.1: Low flow adjustment). Switch on the supply voltage. > > All LEDs light and go out again step by step. The unit is in the operating mode. Let the normal flow circulate in the installation. Check the display and determine further actions. 1 2 3 Low Flow High Low Flow High Low Flow High The factory setting is suitable for the application. No further settings are required. Your normal flow is below the representation range of the display. Carry out high flow adjustment ( 6.1). Your normal flow exceeds the representation range of the display (LED 9 flashes). Carry out high flow adjustment ( 6.1). You can restore the factory setting any time. ( 7.2). 6.1 High flow adjustment (optional) The unit determines the existing flow as normal flow and adapts the display representation (all LEDs light green). Proceed as follows: Let the normal flow circulate in the installation. Press the pushbutton and keep it pressed. > > LED 9 lights, after approx. 5 s it flashes. Release the pushbutton. The unit is now adapted to your flow conditions. It passes into the operating mode, the display should now show example 1. 8

7 Additional settings (optional) 7.1 Low flow adjustment If the unit is used in media other than water, you should additionally adapt the unit to the minimum flow. Note: The following adjustment must only be carried out after the high flow adjustment. Proceed as follows: Let the minimum flow circulate in the installation or ensure flow standstill. Press the pushbutton and keep it pressed. > > LED 0 lights, after approx. 5 s it flashes. Release the pushbutton. The unit adopts the new value and passes into the operating mode. 7.2 Restore the factory setting (reset) Press the pushbutton for at least 15 s. > > LED 9 lights, after approx. 5 s it flashes. > > After approx. 15 s LEDs 0...9 flash orange. Release the pushbutton. All settings are reset to the factory setting: -- operating area: 5...100 cm/s for water -- unlocked. 7.3 Lock / unlock the unit The unit can be locked electronically to prevent unintentional settings. Press both setting pushbuttons simultaneously for at least 10 s in the operating mode. > > The indication goes out, the unit locks or unlocks. On delivery: unlocked. UK 9

8 Error during adjustment If no adjustment is possible, all LEDs flash red. The unit then passes into the operating mode with unchanged values. Possible cause /aid: Error during installation. The difference between maximum flow and minimum flow is too small. The sequence high flow /low flow adjustment was not adhered to. Read chapter 3 Installation. Check whether all requirements have been met. Increase the flow difference and carry out the adjustment once again. Carry out the two adjustment operations again in the right sequence. 9 Operation After every power on all LEDs light and go out again step by step (during this time the output signal is 20 ma). The unit is then ready for operation. In case of power failure or interruption all settings remain. Operating indicators Green LED bar: current flow within the representation range. LED 9 flashes: current flow above the representation range. LED 0 flashes: current flow far below the representation range. Interference indicators Display OFF (no LED lights): Operating voltage too low (< 19 V) or failed. Ensure a correct voltage supply. 10

10 Maintenance Recommended maintenance: Check the sensor tip for build-up from time to time. Clean it using a soft cloth. Stubborn build-up (e.g. lime) can be removed using a common vinegar cleaning agent. 11 Scale drawing 1 2 50 63 UK 14 113 M12 x1 27 22 3 45 60 65 8,2 1: LED bar display 2: set button 3: tightening torque 25 Nm 11

12 Technical data Application area... liquids Operating voltage [V]...19...36 DC 1) Analog output [ma]...4...20, max.22 Max. load [Ω]...500 Current consumption [ma]...< 60 Power-on delay time [s]... 10, optically indicated Liquids Medium temperature [ C]... -25... +80 Setting range [cm/s]...3... 300 Greatest sensitivity [cm/s]...3...100 Repeatability [cm/s]...1...5 2) Temperature drift [cm/s x 1/K]...0.1 3) Response time [s]...1... 10 Pressure resistance [bar]...300 Operating temperature [ C]... -25... 80 Protection rating... IP 67 Protection class...iii Shock resistance [g]... 50 (DIN / IEC 68-2-27, 11 ms) Vibration resistance [g]... 20 (DIN / IEC 68-2-6, 55-2000 Hz) Housing materials...stainless steel 316L / 1.4404; stainless steel 304 / 1.4301; PC (Makrolon); PBT-GF 20; EPDM/X (Santoprene) Materials (wetted parts)... stainless steel 316L / 1.4404 O-ring: FPM 8x1.5 gr 80 Shore A EMC EN 61000-4-2 ESD:... 4 kv CD / 8 kv AD EN 61000-4-3 HF radiated:... 10 V/m EN 61000-4-4 Burst:... 2 kv EN 61000-4-6 HF conducted:... 10 V 1) to EN50178, SELV, PELV; 2) for water; 5...100 cm/s; 25 C (factory setting) 3) for water; 5...100 cm/s; 10...70 C The sensor conforms to the standard EN 61000-6-2 More information at www.ifm.com 12