Installation and Operation Manual

Similar documents
Airflow Controller. Installation and Operation Manual Installation, Operation, Service and Replacement Parts Information. IOM AD Revision 1

Ambient Collection System AT-3000

Replacement Parts List

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

Torit PowerCore TGP. Installation and Operation Manual Installation, Operation, and Service Information TG4 TG12

Torit Easy-Trunk. Installation and Operation Manual Installation, Operation, and Service Information. English Master Language

Torit PowerCore TG 2, 4, 6, 8, and 12

Installation and Operation Manual

Installation and Operation Manual

Torit PowerCore CPV-1, -2, -3, -4, -6, -8, and -12 After November 2008

Replacement Parts List

Installation and Operation Manual

Empire Abrasive Equipment Company

Torit PowerCore CPV-After November 2008

Installation and Operation Manual

Downflo Oval DFO 1-1, 2-2 and 3-3

Owner s manual for installation, usage and maintenance

Torit PowerCore CPC-3, -4, -6, -8, -12, -16, -24, -32, -40 and -48 Hopper Inlet After November 2008

SUPERIOR PERFORMANCE

Downdraft Bench DB-2000 and DB-3000

Installation & Service Manual for Horizontal Cartridge Filtration Systems

Torit Weld Bench WB-2000 and WB-3000

Dalamatic Cased Dust Collectors Series DLM 15

Installation and Operation Manual

IOM AK (ENG) Revision 3

MODEL MC1500 Installation and Operation Manual Important:

Torit PowerCore TG 2, 4, 6, 8, and 12

Installation & Service Manual for Portable Fume Collector. Model PFC-800


TD Collector TD-162 and TD-573

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Packaged Downflo Evolution

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Injection/Sample Quills

Unimaster Dust Collector UMA 40, 70, 100, 150 and 250 Built After August 2005 UMA 450 and 750 Built After March 2006

DOWNFLO OVAL DUST COLLECTORS HIGH VACUUM DFO2-4

INSTALLATION AND OPERATION MANUAL

Positive Displacement Pump

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Easytork Solenoid Valve IOM

WSO Mist Collector WSO 20, 25-1, 25-2 and 25-3

Owner s manual for installation, usage and maintenance

HALLMARK INDUSTRIES INC

SUPER PUMP OUT SYSTEM

FJS Continuous Cleaning Cartridge Series Installation and Operation Manual

Dryflo Machine Mountable Mist Collectors MMA and MMB

Downflo II DFT 2-4 and 3-6 (Units Built After July 2003)

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

SELF PRIMING CHEMICAL SERVICE PUMPS

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

G8 Portable Fuel Transfer Pump Owner s Manual

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Air Boss CA3000C & CA6000C. Installation Operation Maintenance Manual. Cartridge Air Cleaners

Modular Baghouse Top Access MBT and MBTH

Installation and Operation Manual

Power Float Manifold. Installation and Operations Manual Module 11A

QUALITY MISTING PUMPS

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Mini-Mist Air Filter MM 500 and MM 1200

Downflo Oval DFO 2-8, 2-12, 2-16, 2-24, , 3-12, 3-18, 3-24, 3-36, 3-48, 3-60, 3-72, 4-16, 4-32, 4-48, 4-64, 4-80, 4-96, 4-112, and 4-128

Installation and Operation Manual

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Model SD23, SD34, SD46, SD48 Operator s Manual INSPECTION: The Superior table is shipped on one skid. This skid should be inspected for any visible

QUALITY MISTING PUMPS

User s Manual and Operating Instructions

Downflo DFO 2-4 and 3-6

Vibra-Shake VS-550, VS-1200, VS-1500, VS-2400 and VS-3000

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

WELDING FUME EXHAUSTERS & ARMS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

Torit PowerCore VH 1-4, 1-6, 2-8, 2-12, 2-16, 2-20, 3-18, 3-24, 3-30 VL 1-4, 1-6, 2-8, 2-12, 2-16, 2-20, 3-18, 3-24, 3-30

Bin Vent TBV-2, TBV-4 and TBV-6

D-Series Blowers and Exhausters

Low Profile Service Jack

MODEL 1100 TURBINE FLOW METER

FAN POWERED HEPA FILTER UNIT

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Downflo Workstation DWS 4-1, 4-2, 4-3, 4-4 and DWS 6-1, 6-2, 6-3 and 6-4

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

Portable Oil Free Silent Series Compressor Operating Instructions

Air Actuated Hydraulic Bottle Jack on Wheels

DIRECT-DRIVE PRESSURE WASHERS

Installation and Maintenance Manual

User s Manual D-Series Blowers and Exhausters

NECO Pumping Systems

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Cabinet Collector Series Models 54, 64, 66, 75, 81, 84, 90

INSTALLATION AND OPERATING MANUAL

This manual covers the following model:

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Oil Pump Models L 5016, L 5116 & L 5132

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Transcription:

Installation and Operation Manual Installation, Operation and Maintenance Manual HV150, HV300, HV600, HV1000 HV150/300 HV600 HV1000 Throughout this manual statements indicating precautions necessary to avoid equipment failure are referenced in a Note. Statements indicating potential hazards that could result in personal injury or property damage are referenced in a CAUTION! box. Donaldson Company reserves the right to change design and specifications without prior notice. Illustrations are for reference only as actual product may vary. IOM AK0303201 Revision 0

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. CAUTION! Application of Dust Control Equipment Combustible materials such as buffing lint, paper, wood, aluminum or steel dust, weld fume, or flammable solvents represent fire or explosion hazards. Use special care when selecting and operating all dust or fume collection equipment when combustible materials are present to protect workers and property from damage due to fire and/or explosion. Consult and comply with National and Local Codes relating to fire or explosion and all other appropriate codes when determining the location and operation of dust or fume collection equipment. When combustible materials are present, consult with an installer of fire extinguishing systems familiar with these types of fire hazards and local fire codes for recommendations and installation of fire extinguishing and explosion protection systems. Donaldson Torit dust collection equipment is not equipped with fire extinguishing or explosion protection systems. DO NOT allow sparks, cigarettes or other burning objects to enter the hood or duct of any dust or fume control equipment as these may initiate a fire or explosion. For optimum collector performance, use only Donaldson Torit replacement parts. Warning Improper operation of a dust control system may contribute to conditions in the work area or facility that could result in severe personal injury and product or property damage. Check that all collection equipment is properly selected and sized for the intended use. 2

HV150,300,600,1000 Table of contents List of figures 1.0 Product Introduction 6 Figure 1: Schematic 2.0 Installation. 6 Figure 2: Operational Schematic 3.0 Start up and Operation 7 Figure 3: Inlet Schematic 4.0 Service...8 Figure 4: Fan Rotation Check Schematic 5.0 Optional equipment...9 Figure 5: Dust Disposal System 6.0 Trouble Shooting..9 Figure 6: Exchanging Filter Element 7.0 Control Panel 12 Figure 7: BIBO Module 8.0 Spare Parts 22 Figure 8: HV150/300 Control Panel Figure 9: HV150/300 Wiring Diagram Figure 10: HV150/300 BIBO Control Panel Figure 11: HV150/300 BIBO Electrical Terminal Block Figure 12: HV150/300 BIBO Wiring Diagram Figure 13: HV600/1000(BIBO) Control Panel Figure 14: HV1000 BIBO Electrical Terminal Block Figure 15: HV1000 BIBO Wiring Diagram This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss the use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures. Data Sheet Model Number Serial Number Ship Date Installation Date Customer Name Address Filter Type Accessories Other 3

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. 1. Lift lug 2. Filter with access cover 3. Dust bin 4. Control panel 5. Inlet 6. Pressure gauge 7. Pushing button 8. Fan outlet 9. Power supply cable inlet 10. Compressed air inlet 11. Sprinkler coupling Figure 1 Schematic 4

HV150,300,600,1000 HV600/1000 HV150/300 Operation Filter element cleaning 1. Dirty air inlet 2. Filter element 3. Hopper 4. Clean air outlet 5. Manifold 6. Diaphragm valve 7. Tube sheet 8. Air pulse 9. Dust (falling) Figure 2 Operational Schematic 5

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. 1.0 Product Introduction The dust collector is used for the collection of airborne dust and particulate. Whether in answer to the problem of air pollution, or as part of a manufacturing process, the dust collector provides highly efficient and continuous on-line dust collection. The filter elements are the heart of the dust collector. These filter elements help ensure the only cleaned air is returned to the plant environment. During operation, contaminated air enters the dust collector through the dirty air inlet area and passes through the filter elements. Dust is collected on the surface of the filter elements. The filtered air flows through the centre of the filter elements into the clean air chamber, where it exhausts through the clean air outlet re-circulated into the environment. To ensure the optimal performance of your dust collector it is necessary that the filter elements are cleaned automatically sequentially (HV600 and HV1000), and the filter is cleaned manually by pressing the push button (HV150 and HV300), During the filter sequence, the corresponding diaphragm valve will send a pulse of compressed air through the filter elements (from the inside outwards), removing the collected dust from the outside surface of the filter elements. The dust falls through the hopper into the dust disposal system. 2.0 Installation Ensure all persons carrying out work on the supplied equipment follow any relevant recognized standards or codes and are competent to do so. 2.1 Compressed Air Connection Compressed air pressure must be at 6 bar. Be sure that all compressed air components are adequately sized to meet the maximum system requirements of 5 Nliters per pulse at 6 bar supply pressure (= design pressure). Compressed air supply has to be both oil and moisture free. Connect the compressed air supply line to the compressed air connection of the dust collector.and also for pneumatic butterfly Valve if dust collector is equipped with hopper BIBO Module. A compressed air shut-off valve, a filter/water separator with automatic condense drain, a pressure regulator with gage must be installed on the compressed air supply line. 2.2 Electrical Connection Enter the cable through the cable gland locate at the lower right corner (HV150 and HV300) or top right corner (HV600 and HV1000) of the collector. And enter the cable to the control box through the cable gland locate at the top of the enclosure. Please follow the electrical diagram provided for connection. Do not install in classified hazardous atmospheres without an enclosure rated for the application. 6

HV150,300,600,1000 2.3 Inlet Duct Connection The inlet collar is shown on figure 3. 3.0 Start-up and Operation Check that the outlet of the fan is free of debris before starting. Make sure the dust disposal system is properly installed under the hopper. Check if the access doors are closed. Switch main power on and press switch start. Turn on the compressed air supply. Adjust to 6 bar of pressure with the compressed air regular. Motor and fan should be wired for right rotation, see below Figure 4 High temperature air, Please don t touch! To reverse rotation, three-phase power supply: Turn electrical power OFF at source and switch any two leads on the control box. Inlet Blowing air when Operating correctly Hot surface, Please don t Touch! Sucking air when Operating correctly Figure 3 Inlet Schematic Figure 4 Fan Rotation Check Schematic 7

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. 4.0 Service 4.1 Dust Removal Caution Disconnect electrical power before servicing. Shut off and bleed compressed air supply before servicing any compressed air components. The filter elements are cleaned automatically and sequentially. Don t move out the filter elements and clean. Do not let the dustbin overfill. It can cause poor dust collector performance. Turn off the dust collector and empty the dustbin on a regular base (recommend to empty the dustbin when 2/3 full). 4.2 Replacing of Filter Elements Caution: When the airflow is low or the differential pressure is too high and alarm, must change the filter elements. All filters elements should be changed at the same time. Do not drop the new filter element on the floor or any other hard surface. It is necessary to clean the dust of the tube sheet all around the opening to ensure a positive seal of the gasket. Slide the new filter element along the yoke with the gasket end facing inward towards the clean air chamber. Screw the wing nut clockwise onto the yoke. Tighten securely, to prevent leakage. Move out From this side Figure 5 Dust Disposal System Figure 6 Replacing of Filter Elements 8

HV150,300,600,1000 5.0 Optional equipment HEPA BIBO for Filter BIBO for Hopper Figure 7 BIBO Module(Option) 6.0 Trouble shooting WARNING Disconnect all power before servicing to prevent injury or extensive damage. Direct compressed air supply towards human body or equipment will cause serious injury, shut off and bleed compressed air supply before servicing any compressed air components. Automatically cut off of system power indicates abnormal function of electrical components. Requires a qualified electrician according to local codes to check all electrical work. 9

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. Problem Probable Cause Remedy Fan does not start Not wired correctly. Check and correct internal motor wiring for proper connections for your voltage (see Wiring Diagram) Proper wire size not used for motor Rewire per national and local electric codes for proper wire size. Fan set starts, but does not keep running Incorrect overload protection is installed Dust collector doors are open or not closed tight Check for proper motor overload protection. Reset or replace if needed for proper value. Tighten doors securely. Hopper open to atmosphere Electrical circuit fuses Install dust bin under hopper and seal the access door securely. Check if the supply circuit has sufficient power to run all equipment. Excessive noise/vibration of the fan If this happens, it should be rectified at once Dust deposit on the blades Worn blades Worn bearings Clean the blades. The fan wheel has to be replaced. The bearings have to be replaced. Dust emission Filter elements installed improperly Filter element damage, dents in the end caps, gasket damage or holes in pleated media Check that gaskets on the filter element(s) are firmly pressed to the tube sheet (the wing nuts of the filter elements should be fully tightened by hand). Replace the filter elements. Doors not airtight Tighten doors securely and check sealing. 10

HV150,300,600,1000 Problem Probable Cause Remedy Insufficient airflow Fan wheel rotating wrong way Openings not properly sealed Outlet is restricted Check fan rotation. Refer to 3.0 Check doors, that they are closed and tightened securely. Also check hopper area that openings are closed off and that the hopper dust disposal is installed. Check outlet for blockage. Remove material or debris that is blocking the outlet. Filter elements plugged : a. Lack of compressed air b. Pulse cleaning not energized c. Dust disposal system is too full or plugged d. Hopper full of dust or plugged e. Filter elements need to be replaced Check compressed air supply for under 6 bar. Refer to the trouble shooting guide from the Control manual. Clean out dust disposal system.. Clean out the hopper. Replace the filter elements Solenoid valves/diaphragm valves are not functioning: a. Solenoid valves/diaphragm valves are leaking compressed air b. Pulse control printed circuit board has failed or is out of adjustment Check for debris, obstruction, and valve wear or diaphragm failure by removing the diaphragm cover on the solenoid valves. Also check for solenoid leakage damage. If diaphragm valves or solenoid valves are damaged replace it or replace damaged part(s). Refer to Operating manual of the Controls. Excessive noise of a diaphragm valve Failure on the diaphragm valve Check for debris, obstruction, valve wear or failure by removing the diaphragm cover. If the diaphragm valve is damaged, replace it or replace damaged part(s). 11

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. 7.0 Control Panel Figure 8 HV150/300 Control Panel (Standard) 7.1 Control panel functions The Start/Stop button is for fan motor on/off. And these 2 buttons also provides lights for indication of fan motor run/stop status. Fan motor overload protection and overload indication (Alarm). When press the Start button, the fan motor will be powered up. When the start button is started the Start green indication light will light up; When press the "Stop". The fan motor will be turn off. When push the "Stop" button, the Stop red indication light will light up and the fan motor dis-energized. 7.2 Operation Ensure that the control panel is correctly installed onto the dust collector before starting up (check main power supply connections, all electrical cable connections, fan starter/fan motor connections, solenoid/diaphragm valve connections, compressed air tubing connections, etc.) For safety of personnel and equipment, ensure that the control panel is properly grounded. Turn the main power supply switch to "ON" position. There is overload protection for the fan motor, the setting of AMPs according to the nameplate of the fan motor. When the "Stop" indication light lights up it signifies that the fan motor is overloaded and has stopped. To terminate electrical power supply to the pulsing control, please ensure that the fan motor is shut down before turning the main power supply switch to the "OFF" position. 12

HV150,300,600,1000 Figure 9 HV150/300 Wiring Diagram 13

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. Figure 10 HV150/300 BIBO Control Panel (Option) 14

HV150,300,600,1000 7.3 HV150/300 BI/BO Control panel functions (Option) The Auto/Manual selection switch for AUTO or MANUAL cleaning control model selecting. When the selection switch is at the "Manual" position, the valve 1 and 2 can be open manually. When the selection switch is at the "Auto" position, the valve 1 and 2 will be controlled by the timer. Fan motor overload protection and overload indication (Alarm). When press the Valve closed button the valves will be closed and the red indication light will light up; When press the "Manual SV1/SV2" and the mode selection switch is set at "Manual position, the valve 1 and valve 2 can be open buttons respectively. When push the Manual SV1/SV2 button, the green indication light will light up When press the "Auto SV1/SV2" button and the "Auto/Manual" selection switch is set at "Auto" position, the valve 1 and 2 will be controlled by the timer, And the valve 1 and valve 2 will be opened by turns. 7.4 HV150/300 BI/BO Operation (Option) Ensure that the control panel is correctly installed onto the dust collector before starting up (check main power supply connections, all electrical cable connections, fan starter/fan motor connections, solenoid/diaphragm valve connections, compressed air tubing connections, etc.) For safety of personnel and equipment, ensure that the control panel is properly grounded. Turn the main power supply switch to "ON" position. There is overload protection for the fan motor, the setting of AMPs according to the nameplate of the fan motor. When the "Alarm" indication light lights up it signifies that the fan motor is overloaded and has stopped. To terminate electrical power supply to the pulsing control, please ensure that the fan motor is shut down before turning the main power supply switch to the "OFF" position. We use the OMRON H5CZ-L8 Bidirectional timer to control the valve 1 and valve 2 alternately, and we can set the alternating time from 9.999s to 9999h freely. 15

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. Figure 11 HV150/300 BIBO Electrical Terminal Block (Option) 16

HV150,300,600,1000 Figure 12 HV150/300 BIBO Wiring Diagram (Option) 17

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. Figure 13 HV600/1000 (BIBO) Control panel 18

HV150,300,600,1000 7.5 HV600/1000 (BIBO for option) Control panel functions The Local/Remote selection switch is for LOCAL or REMOTE fan motor on/off control selecting. And the control panel also provides one voltage free contact output for indication of fan motor run/stop status. The Auto/Manual selection switch for AUTO or MANUAL cleaning control model selecting. When the selection switch is at the "Manual" position, the collector will clean continually. When the selection switch is at the "Auto" position, the collector cleaning will controlled by the Torit Delta P-C01 controller on the panel, and the control panel can also provide down-time cleaning. Fan motor overload protection and overload When the Local/Remote selection switch is set at Remote position, the start/stop of the fan motor can be controlled remotely. When the remote control switch is closed the Running green indication light will light up and the fan motor will be powered up; when the remote control switch is opened the Running green indication light will go off, and the fan motor dis-energized. When the "Local/Remote" selection switch is set at "Local" position all control operations need to be carried out locally at the control panel. The fan motor can be turn on and off by pushing the "Fan Start" and "Fan Stop" buttons respectively. When push the Fan Start button, the Running green indication light will light up and the fan motor will be powered up; when push the Fan Stop button the Running green indication light will go off and the fan motor dis-energized. 7.6 HV600/1000 (BIBO for option) Operation Ensure that the control panel is correctly installed onto the dust collector before starting up (check main power supply connections, all electrical cable connections, fan starter/fan motor connections, solenoid/diaphragm valve connections, compressed air tubing connections, etc.) For safety of personnel and equipment, ensure that the control panel is properly grounded. Turn the main power supply switch to "ON" position. The Torit Delta P-C01 controller will power up. All operating instructions for the Torit Delta P-C01 controller are mentioned in a separate manual of Delta P-C01. There is overload protection for the fan motor, the setting of AMPs according to the nameplate of the fan motor. When the "Error" indication light lights up it signifies that the fan motor is overloaded and has stopped. To terminate electrical power supply to the pulsing control, please ensure that the fan motor is shut down before turning the main power supply switch to the "OFF" position. For HV 600/1000 BIBO model will add 2 valves to discharge the dust and particles, and these 2 valves will working alternately and the alternating time can be setting in the Logo controller. When the "Auto/Manual" selection switch is set at "Manual" position, the cleaning will process continually. When the "Auto/Manual" selection switch is set at "Auto" position the cleaning will be controlled by the Torit Delta P-C01 controller on the panel. At any time the cleaning pulse is activated, the Cleaning indication light on the Delta P-C01 controller will light up. 19

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. Figure 14 HV1000 BIBO Electrical Terminal Block 20

HV150,300,600,1000 Figure 15 HV1000 BIBO Wiring Diagram shown (option) 21

Donaldson 唐纳森 ( 无锡 (Wuxi) ) 过滤器有限公司 Filters Co.,Ltd. 8.0 Spare Parts Item Description Part number 1 Filter Assembly-Ultra Web FR P191115 2 Filter Assembly-Ultra Web SB P031851 3 Filter Assembly-Ultra Web AS P034080 4 Diaphragm valve 8PP-19307-00 5 Solenoid Valve(HV600) 8PP-48948-10 6 Solenoid Valve(HV1000) 8PP-48948-09 7 Relief valve 8PP-AK00099-50 8 Delta P-C01 115V/230V 8PP-AK01004-00 9 High temperature HEPA P280617 Note: When ordering parts, give model number and serial number of dust collector, description and quantity of parts desired. 22

Service Notes Date Service Performed Notes 28

The Donaldson Torit Warranty Donaldson does not warrant against damages due to corrosion, abrasion, normal wear and tear, product modification, or product misapplication. Donaldson also makes no warranty whatsoever as to any goods manufactured or supplied by others including electric motors, fans and control components. After Donaldson has been given adequate opportunity to remedy any defects in material or workmanship, Donaldson retains the sole option to accept return of the goods, with freight paid by the purchaser, and to refund the purchase price for the goods after confirming the goods are returned undamaged and in usable condition. Such a refund will be in the full extent of Donaldson s liability. Donaldson shall not be liable for any other costs, expenses or damages whether direct, indirect, special, incidental, consequential or otherwise. The terms of this warranty may be modified only by a special warranty document signed by a Director, General Manager or Vice President of Donaldson. Failure to use genuine Donaldson replacement parts may void this warranty. THERE EXIST NO OTHER REPRESENTATIONS, WARRANTIES OR GUARANTEES EXCEPT AS STATED IN THIS PARAGRAPH AND ALL OTHER WARRANTIES INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHETHER EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED. Parts and Service For genuine Donaldson replacement filters and parts, call the Parts Express Line. For faster service, have unit s model and serial number, quantity, part number, and description available. Donaldson Australasia Website: www.donaldson ilters.com.au Donaldson Japan Tel: +81 42 540 4114 Website: www.donaldson.co.jp Donaldson Southeast Asia Tel: +65 6349 8168 Website: www.asia.donaldson.com Donaldson Tel: 00 820 1038 Website: www.donaldson.cn Donaldson South Asia Tel: +91 124 480 7536 Website: www.india.donaldson.com Donaldson Korea Tel: +82 251 733 33 Website: www.donaldson.co.kr Donaldson Europe Tel: +32 16 383 811 Website: www.donaldson.com Donaldson USA Tel: +1 800 365 1331 Website: www.donaldsontorit.com Donaldson Company, Inc. is the leading designer and manufacturer of dust, mist, and fume collection equipment used to control industrial-air pollutants. Our equipment is designed to help reduce occupational hazards, lengthen machine life, reduce in-plant maintenance requirements, and improve product quality. 201 Donaldson Company, Inc. Printed in APAC IOM AK030 01, Revision