Lube Level Maintainer

Similar documents
Lube Level Maintainer

Lube Level Maintainer

Lube Level Maintainer

LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Sentry Battery Charger. Installation and Operations Manual Section 75

Guardian Battery Charger Series. Installation and Operations Manual Section 75

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

DF Series Hydrostatic Head Level Switches

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

Tachometers and Tach/Hourmeters

MODEL G300 BRAKE BLEEDER

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Solenoid Valve Installation Kit

120RMAM Marine Series Fuel Filter/Water Separators

400 Series Spin-on Fuel Filter/Water Separators

Tachometers and Tach/Hourmeters

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

2 Fluid Level Management

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

S&S. Instruction IMPORTANT NOTICE:

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Model RM-1 Riser Manifold Commercial and Residential General Description

Powers Controls Powertop Two-Way Valves Normally Open

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

KENCO ENGINEERING COMPANY P.O. BOX TULSA, OK PHONE(918) FAX: (918)

Moduflow. ILP and RFP Low Pressure Filters. Series

Thermo-Bob 1 Installation Manual: Kawasaki Concours

Back Pressure Regulator

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

TECHNICAL INSTRUCTIONS #11 REGULATOR Single Seat - Bronze Trim - Composition Disc

P10 Series Low Range Pressure Controls

Installation Notes for Caterpillar 3306/3456/C15 Gen Set Package. Caterpillar 3306/3456/C15 Generator Set Package. Puradyn Part # Description Qty

Laboratory Exhaust Air Terminal

Series 3900/M Pump Retrofit Kit

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

I-BFV.KIT Butterfly Valve Gear Operator Replacement

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

Combustion Technologies By-Pass Filtration Instructions

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

EP-2 Si Three-Piston Pump

15/40/80CN Series. Medium Pressure Filters

320R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev.

0-500 PSI Soft Seat Fluid Pressure Regulator

P70, P72, and P170 Controls for Low Pressure Applications

ARC GPM MAX WARNING BEFORE BEGINNING INSTALLATION OF THIS APSCO PRODUCT READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

MB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608)

0-800 psi Carbide Seat Fluid Pressure Regulator

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

DIMENSIONS. Oil Capacity = 14.6 oz Maximum Fluid Temperature = 140 F Inlet Thread = 1/2 F Discharge Thread = 3/8 F

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Soft Seat Fluid Pressure Regulator

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

P843NSATS For Models: NL843N2, NL843NW2, and NL843NW3 PARTS CATALOG. Marine Generators Marine Diesel Engines Land-Based Generators

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

INSTRUCTIONS. EZ-EFI FK In-Tank Fuel Kit

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Installation Components AirCare Air Preparation Systems

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

IL8 Series. Medium Pressure Filters

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Fisher 644 and 645 Differential Pressure Pump Governors

Model LA 4400 Time Delay OFF Controller

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Pneumatic Isolation Module

IL8 Series. Medium Pressure Filters

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Installation Instructions for Chevrolet C5 Corvette Lingenfelter High Flow Fuel Pump Module

Model LA 4300 Time Delay OFF Controller

EP-2 Three-Piston Pump

P70, P72, and P170 Series Controls for High Pressure Applications

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

IFOA Integral Flow Orifice Assembly

Operating Instructions

XMV 3400 RPM D VERSION 1 WITH GAS ENGINE FLANGE DIMENSIONS

15/40/80CN Series Coreless Medium Pressure Filters

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Model 116 DPI Switch Installation and Operating Instructions

Type 644 and 645 Differential Pressure Pump Governors

Service Guide. High-Pressure Grease Pump. 100 psi (6.8 bar) High-Pressure Pump Model 7785 Series Specifications

ANNUAL UST SYSTEM INSPECTION CHECKLIST

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

REPLACEMENT PARTS MANUAL HEAT KING HK300. Mobile Glycol Heating System

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Model LA 4100 Time Delay OFF Controller

KENCO ENGINEERING COMPANY P.O. BOX TULSA, OK PHONE(918) FAX: (918)

Installation, Operation and Maintenance Manual

Transcription:

Lube Level Maintainer Models LM2000/LM2000S Installation Instructions 00-02-0423 Revised 08-12-09 Section 15

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. The latest version of this manual can be found at www.fwmurphy.com. Warranty - A two year warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm. In the event of a fault or technical query, please contact your Murphy representative for technical support. Please read the following information before installing. BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT: A visual inspection of this product for damage during shipping is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product. Disconnect all electrical power to the machine. Make sure machine cannot operate during installation. Follow all safety warnings of the machine manufacturer. Read and follow all installation instructions. Please contact FW MURPHY immediately if you have any questions.

Table of Contents General Information........................................................ 1 Description... 1 Dimensions... 1 Operating Range of the Snap-Switch... 1 Thumb-Valve Operation... 2 Service Parts (Specify part number)... 2 Optional Hose Kit: 15000355... 2 Optional Vent Fittings Kit: 15000954... 2 Typical Installation......................................................... 3 Mounting the LM2000... 3 Pipe Bracket Mounting (15000238)... 3 Mounting with Universal Bracket (15000370)... 3 Connecting Fittings and Hoses... 4 Connecting the LM2000 to an Oil Supply Tank... 5 Switch Test... 5 LM2000 Typical Installation Shown with FSV Series Valves... 6 Specifications............................................................. 7

(THIS PAGE INTENTIONALLY LEFT BLANK)

General Information Description The Murphy LM2000 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running-oil-level, the LM2000 will replenish oil as it is used. An integral, low-level switch will alarm and/or shutdown the equipment if supply oil is lost and the equipment continues to use oil. Dimensions Operating Range of the Snap-Switch Figure 1 shows the LM2000 dial and the operating range of the switch. If level is within the designated zones the switch will activate. The switch activates approximately 1/4 in. (6 mm) from the bottom of the low zone. The dial in Figure 1 shows that if level continues to drop into the low-low zone, a shutdown will occur. Figure 1 NOTE: Color zones on dial face show approximate normal operating zones. Actual conditions may vary depending upon operating characteristics of the engine. Placement of the LM2000 according to the above instructions will compensate for these conditions. 08-12-09-1 -

General Information continued Thumb-Valve Operation As the equipment uses oil, the float falls, providing immediate level compensation. At FULL position, the float holds the valve closed. If the clean oil supply is depleted and oil level continues to fall, the low level switch will operate an alarm or equipment shutdown. Service Parts (Specify part number) Description Part Number Vent Fittings Kit 15000954 Hose Kit 15000355 1/2NPT x 1/2 in. Hose Barbed Fitting 89080801 3/4NPT x 1/2 in. Hose Barbed Fitting 89081001 3/8NPTF x 1/2 in. Hose Barbed Fitting 89080601 Pipe Bracket Kit 15000238 Universal Flange Kit 15010224 Optional Hose Kit: 15000355 Quantity Description 1 1/2 in. (13 mm) I.D. x 3 ft. (914 mm) long hose (89020202) 1 1 in. (25 mm) I.D. x 3 ft. (914 mm) long hose (89020203) 2 1/2 in. (13 mm) worm gear clamp (00003502) 2 1 in. (25 mm) worm gear clamp (00003503) 2 1/2 NPT x 1/2 in. (13 mm) barbed fitting (89080801) 2 3/4 NPT x 1 in. (25 mm) barbed fitting (89081001) Optional Vent Fittings Kit: 15000954 The 15000943 kit is sold separately. It includes the following items: Quantity 1 Tubing vent (15050202). 1 1/4 x 1/4 NPT Connector (85030447). Description 08-12-09-2 -

Typical Installation Mounting the LM2000 NOTE: Mount the LM2000 as close as possible to the crankcase. CAUTION: Excessive vibration can cause overfill. Be sure mounting brackets are supported. The following instructions are based on the usage of the pipe and universal mounting brackets shown on page 1. Pipe Bracket Mounting (15000238) 1. Mount a nominal 1/2 inch (13 mm) diameter pipe to the base of the engine. 2. Install the pipe bracket to the LM2000 using two 1/4-20 UNC x 1 inch bolts, nuts and lock washers supplied. See Figure 2A. 3. Slip the LM2000 onto the pipe and install the two adjustment bolts. Each bolt consists of a 1/4-20 UNC x 1 in. bolt, nuts and lock washers. See Figure 2B. DO NOT tighten the adjustment screws too tightly because you will have to adjust the LM2000 later in the installation process. Figure 2A Figure 2B Mounting with Universal Bracket (15000370) The universal bracket has two mounting methods: base mounting or pan mounting. Base Mounting 1. Install the universal bracket to the base as shown in Figure 3A using two flat washers and two 5/16 inch dia. bolts or others as necessary. 2. Mount the LM2000 to the universal bracket using two 1/4-20 UNC x 1-1/4 inch (32 mm) bolts, nuts and lock washers supplied (Figure 3B). DO NOT tighten the adjustment screws too tightly. You will have to adjust the LM2000 later in the installation process. Figure 3A Figure 3B 08-12-09-3 -

Typical Installation continued Mounting with Universal Bracket (15000370) continued Crankcase (Oil Pan) Mounting 1. Install the universal bracket to the crankcase using the existing crankcase bolts (Figure 4A). Crankcase bolt diameter must be no larger than 7/16 inch (11 mm). Figure 4A Figure 4B NOTE: Check clearance between crankcase and mounting bracket before installing the mounting bracket. If space between the crankcase and mounting bracket does not allow installation and access to the adjustment bolts advance to Step 3. 2. Mount the LM2000 to the universal bracket using two 1/4-20 UNC x 1-1/4 inch bolts, nuts and lock washers supplied. DO NOT tighten the adjustment bolts too tight. You will have to adjust the LM2000 later in the installation process. 3. If space between the crankcase and mounting bracket is narrow, install the universal mounting bracket to the LM2000 before installing to the crankcase oil pan. Connecting Fittings and Hoses The following instructions are based on the Murphy optional hose kit described on page 1. If you did not order the optional hose kit, use the list designation as a guide to the required materials. 1. Install the LM2000 fittings in their proper locations. NOTE: Apply a sealant such as Teflon, to all threaded connections. 2. Attach the 1 inch (25 mm) diameter, flexible monitoring hose to the crankcase and the monitoring port on the LM2000. See Figure 5. CAUTION: The hose must slope slightly downward from the LM2000 and MUST NOT have any droops or low spots. NOTE: If the drain plug on the crankcase is used for the connection, we recommend installation of a tee to allow draining of the crankcase for service. Figure 5 3. Install the 1/2 inch (13 mm) I.D. x 3 ft. (914 mm) hose to the vent connection on the LM2000 and to the vent connection on the crankcase. See Figure 5. The vent connection on the crankcase must be well above the regulated oil level. All hoses must be clear of obstructions, valleys, or dips that could create liquid traps, or gas/air pockets. The vent and crankcase connections should be as straight as possible. 08-12-09-4 -

Typical Installation continued Connecting Fittings and Hoses continued BEFORE CONTINUING, VERIFY THAT ALL HOSE CLAMPS ARE TIGHT. 4. Fill the crankcase to the proper oil level. With the engine running and warm, loosen the mounting bracket adjustment bolts and adjust the LM2000 so that the oil level in the sight gauge is aligned with the white index line on the dial (Figure 5). Tighten the adjustment bolts securely. Connecting the LM2000 to an Oil Supply Tank 1. Remove the plug from the oil inlet connection. Be sure the removable screen, inside the connection, is clear of debris. Install the oil inlet connection. 2. Connect a 1/2 inch I.D. (13 mm) or larger hose to the oil inlet fitting on the LM2000 and to the shutoff valve on the oil supply tank. See Figure 5. Recommended minimum height above the LM2000 is 2 ft. (0.6m); maximum 25 ft. (7.7m). The hose must maintain a downward slope and not have low spots or droops. Maximum head pressure rating is 9.50 psi or 25 ft oil (head pressure). 3. Before filling the supply tank with oil, be sure the tank is clean and dry and the shutoff valve is closed. Also, be sure all hoses and clamps are tight. Fill the tank with CLEAN oil. WARNING: Overfill condition can be caused by excessive inlet pressure and/or improper vent to crankcase installation. Figure 6 4. After oil supply tank is full, open the shutoff valve. Next, make the proper electrical connections for the application. (See Snap-switch ratings and schematic on page 1.) Switch Test To test the shutdown or alarm functions perform the following: NOTE: Installations with closed vent systems can only be tested with the engine off. 1. Unscrew the vent fittings. 2. Using a long narrow shank screw driver, gently insert until contact is felt with float arm. Gently push the float arm down. 3. Verify proper switch operation 08-12-09-5 -

Typical Installation continued LM2000 Typical Installation Shown with FSV Series Valves WARNING: Perform this installation using appropriate protection. Trapped air and hot oil may cause burns. 08-12-09-6 -

Specifications Crankcase Balance Vent Connection: 1/2 NPTF (top). Inlet Connection: 1/2 NPTF with removable screen (side). Outlet Connection: LM2000 3/4 NPTF (bottom). LM2000S 2 x 3/8 NPTF (side) 1 x 3/4 NPTF (bottom) Thumb-Valve Material: Viton. Snap-switch: SPDT rating 10 A, 125 VAC; 0.5 A, 125 VDC; 10 A, 30 VDC. Wire leads: 18 AWG x 14 in. ± 2 in. (355 mm) length. Conduit Connection: 1/2 inch conduit (female, top). Case: Die cast aluminum Lens: Clear Frog Eye non-staining, high impact, high temperature nylon; UV and heat stabilized. Dial: High visibility white background with green and white index lines for normal level indication. Maximum Inlet Pressure: 9.50 psi/25 ft. oil (head pressure). Maximum Case Pressure: 15 psi (103 kpa). Maximum Differential: 2 in. (51 mm) between running and stopped. Maximum Ambient Temperature: 250 F (121 C). Float: Brass Flow Rates: SAE 40 motor oil @ 32 F (0 C) with 2 ft. head pressure: 0.5 GPH (1.9 LPH). NOTE: Friction losses due to piping not considered. 08-12-09-7 -

(THIS PAGE INTENTIONALLY LEFT BLANK)

MURPHY, and the Murphy logo are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textural matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2007 Murphy Industries, Inc. Other third party product or trade names referenced herein are the property of their respective owners and are used for identification purposes only. 08-12-09-9 -