SILENCERS. Contents. Page No. Features, Description, Sizes and Options. Performance Data. Submittal Data Request Sheet

Similar documents
Quiet-Duct Conic-Flow Silencers Section Specifications

to obtain the specified voids due

[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

SILENCER SELECTION INSTRUCTIONS

SINGLE DUCT TERMINAL UNITS

FAN POWERED TERMINAL UNITS

Content - Silencers. Silencers for spiral systems. Silencers for rectangular systems

SILENCER SELECTION INSTRUCTIONS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

SINGLE DUCT TERMINAL UNITS 3000 SERIES

RPD ROUND PLAQUE DIFFUSER

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Model ND-2 Specification

FAN POWERED TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

series Silencers

VAV TERMINAL BOXES TYPE: BA BT

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Variable Air Volume (VAV) Pressure Independent Control

VAV Terminal Units SDS

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

I Fan Powered Terminal Unit

AL-Maraj Central A/C Systems Accessories Mfg Co.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Variable Air Volume Dampers

High Performance Fan Coils FCHG Genesis Series Horizontal

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

VARYCONTROL VAV Dual Duct Terminal Boxes

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

IAC Duct Silencer Catalogue

forward curved inline duct blowers

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Requires Ductwork and Blower

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

SINGLE DUCT AIR TERMINAL UNITS

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

SINGLE DUCT AIR TERMINAL UNITS

Volume Flow Limiters Type VFL

TBV - Terminal Unit. Halton TBV. Terminal Unit

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

IAC Duct Silencer Catalogue

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

SECTION DUST COLLECTOR

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

SECTION DUCTWORK ACCESSORIES

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

Good, Better, & Best Duct Design. An Overview for ASHRAE Bi State Chapter March 14, 2012

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

VAV/CAV BOXES COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

MOTORIZED VOLUME DAMPER

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Direct Gas-Fired Heating

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

SERENO

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm


EGG CRATE RETURN GRILLE

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

& 12" 96" / TABD CATALOG

Thermal Isolation. Break

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

SPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT

Sound is created by a source, is transmitted by come path, and is received by the occupants of the space.

VENT SILENCER PRODUCT GUIDE

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

Blower Specifications

FLEXMASTER HVAC Solutions

Transcription:

Contents Page No. Features, Description, izes and Options Rectangular Dissipative ilencers RBB-LP Rectangular Broad Band - Low Pressure Insertion Loss RBB-MP Rectangular Broad Band - Medium Pressure Insertion Loss RBB-HP Rectangular Broad Band - High Pressure Insertion Loss 1 B Performance Data Rectangular Dissipative ilencers RBB-LP Rectangular Broad Band - Low Pressure Insertion Loss 2 RBB-MP Rectangular Broad Band - Medium Pressure Insertion Loss 3 RBB-HP Rectangular Broad Band - High Pressure Insertion Loss 4 ubmittal Data Request heet Rectangular Dissipative ilencers RBB-LP, MP and HP Rectangular Broad Band 5 7-12-16

Models: Rectangular Dissipative ilencer RBB-LP Low Pressure RBB-MP Medium Pressure RBB-HP High Pressure Rectangular Dissipative ilencer FEATURE AND BENEFIT OF ENGINEERED ACOUTIC: Engineered Acoustics rectangular dissipative silencers are designed to offer superior acoustic and aerodynamic performance. Rectangular models utilize acoustical splitters, sometimes called baffles, for broad-band attenuation. Perforated metal protects the glass fiber from erosion by the airflow. imilarly circular models have acoustical center-bodies, sometimes referred to as pods. They also incorporate glass fiber external to the duct connection size. plitters in rectangular models vary in quantity and thickness, and air passages also vary in size. The splitters and center bodies are aerodynamically shaped to minimize pressure drop. The latest in control components and options provide maximum flexibility with a wide scope for cost effective innovation. DECRIPTION: Engineered Acoustics rectangular dissipative silencers are designed to offer superior acoustic and aerodynamic performance. All performance data is independently tested using a 24" x 24" (610 x 610) rectangular sample. Engineered Acoustics designs and manufactures silencers for virtually any application, as well as custom designs to meet any special need. Applications include return, supply, and exhaust ductwork, in addition to, fan plenums and air handling units. Constructed with a standard outer casing of 22 gauge (0.85) galvanized steel, all external seams are lock formed and sealed to withstand up to 10" w.g. (2.5 kpa) pressure differential. Each internal "pod" includes a solid 22 gauge (0.85) elliptical nosepiece, transparent perforated metal, and is exceptionally tapered to minimize dynamic pressure loss and maximize static pressure regain. The inorganic, odorless, vermin and moisture proof, absorption media is compressed a minimum of 5% to eliminate voids and prevent settling. The incombustible filler material does not exceed the fire hazard classifications in accordance with NFPA 90A and UL 181. ilencer models include: Rectangular Broadband Low Pressure, Medium Pressure, and High Pressure. IZE: Rectangular Dissipative ilencer lengths available in 36", 60" and 84" TANDARD FEATURE: Constructed with a standard outer casing of 22 gauge (0.85 mm) galvanized steel All external seams are lock formed and sealed to withstand up 10" w.g. (2.5 kpa) pressure differential. Each internal "pod" includes a solid 22 gauge (0.85) elliptical nosepiece, transparent perforated metal, and is exceptionally tapered to minimize dynamic pressure loss and maximize static pressure regain. Baffles are filled with inorganic, odorless, vermin, and moisture proof, absorption media is compressed a minimum of 5% to eliminate voids and prevent settling. Galvanized aerodynamically shaped nose at inlet Centerbody pods are centered in air stream and supported by steel brackets Perforated galvanized baffles are complete with perforated diffuser tail Options: High temperature sealant Field or Factory assembled multiple modules TDF Flange one or both ends 2" flange one or both ends 18 gauge (1.31 mm) outer casing construction 7-12-16 1

Performance Data Insertion Loss Model: RBB-LP Rectangular Broad Band - Low Pressure Insertion Loss Length tatic Pressure Drop 63 125 250 500 1000 2000 4000 8000-2000 0.20 1 5 10 18 25 19 13 9-1000 0.07 1 5 9 19 25 19 13 10 36 0 0 2 4 9 18 25 19 14 10 +2000 0.19 2 4 8 16 24 19 15 10 +2500 0.30 1 4 8 16 24 19 15 10-2000 0.30 1 9 15 31 41 30 17 8-1000 0.10 2 9 14 31 42 31 17 9 60 0 0 2 7 13 30 45 33 19 12 +2000 0.27 2 6 12 27 42 34 21 12 +2500 0.42 1 6 12 26 41 33 20 12-2000 0.40 4 13 23 40 44 38 21 11-1000 0.12 4 11 20 42 47 40 23 11 84 0 0 4 10 19 41 49 42 26 15 +1000 0.10 3 9 18 40 49 42 27 15 +2000 0.38 3 9 17 39 47 40 27 16 elf Generated Noise (fpm) 63 125 250 500 1000 2000 4000 8000-2000 66 61 57 61 63 67 59 52-1000 55 51 48 52 56 49 42 32 +1000 58 49 40 39 34 27 24 22 +2000 62 59 52 50 51 54 53 48 Area Correction Factors Area 0.5 1 2 4 8 16 32 64 128 256 PWL (db) -8-6 -3 0 +3 +6 +9 +12 +15 +18 2 12-15-05

Performance Data Insertion Loss Model: RBB-MP Rectangular Broad Band - Medium Pressure Insertion Loss Length tatic Pressure Drop 63 125 250 500 1000 2000 4000 8000-1500 0.18 2 6 12 21 29 23 13 7-1000 0.09 2 6 11 21 29 23 13 7 36 0 0 2 5 10 21 28 23 16 10 +1000 0.07 2 4 10 20 28 23 16 10 +2000 0.28 1 4 9 18 27 23 15 10-1500 0.26 3 10 17 35 45 36 20 11-1000 0.12 4 9 16 35 46 38 22 11 60 0 0 5 9 16 35 47 41 25 14 +1000 0.10 5 8 15 34 47 41 26 14 +2000 0.41 4 7 15 33 46 39 26 14-1500 0.30 8 12 24 40 46 40 26 15-1000 0.15 8 12 23 42 47 41 27 15 84 0 0 6 11 21 43 49 45 29 16 +1000 0.13 7 10 20 42 49 46 29 16 +1500 0.28 6 9 19 41 46 44 30 17 elf Generated Noise (fpm) 63 125 250 500 1000 2000 4000 8000-1500 61 55 54 58 60 62 56 48-1000 54 50 49 52 55 55 47 37 +1000 54 50 42 42 39 36 34 29 +2000 60 59 59 52 52 55 56 52 Area Correction Factors Area 0.5 1 2 4 8 16 32 64 128 256 PWL (db) -8-6 -3 0 +3 +6 +9 +12 +15 +18 12-15-05 3

Performance Data Insertion Loss Model: RBB-HP Rectangular Broad Band - High Pressure Insertion Loss Length tatic Pressure Drop 63 125 250 500 1000 2000 4000 8000-1500 0.50 3 9 16 26 30 27 18 11-1000 0.23 3 8 15 26 31 28 19 12 36 0 0 3 6 14 27 36 31 21 13 +1000 0.21 3 6 13 25 35 31 21 13 +2000 0.83 2 6 12 23 32 30 19 11-1000 0.39 9 14 22 40 44 45 31 15-500 0.11 10 13 21 42 46 48 33 17 60 0 0 8 12 21 42 49 50 35 20 +1000 0.37 8 11 19 40 48 50 36 20 +1500 0.84 6 10 18 39 47 49 35 19-1000 0.40 9 18 31 39 43 45 33 19-500 0.21 10 17 30 42 46 48 37 22 84 0 0 10 16 26 45 49 51 38 23 +1000 0.38 9 14 25 44 47 48 37 22 +1500 0.86 7 14 25 44 45 46 35 20 elf Generated Noise (fpm) 63 125 250 500 1000 2000 4000 8000-1500 63 58 57 62 66 71 68 61-1000 55 51 51 56 61 63 57 49 +1000 50 49 43 44 41 40 42 38 +2000 66 62 58 56 56 60 55 62 Area Correction Factors Area 0.5 1 2 4 8 16 32 64 128 256 PWL (db) -8-6 -3 0 +3 +6 +9 +12 +15 +18 4 12-15-05

ubmittal Data Request Models: RBB-LP, MP and HP Rectangular Broad Band PECIFICATION: Outer casing is constructed of 22 gauge galvanized steel. All external seams are lockformed and filled with a suitable joint compound and air tight up to 10.0" water gauge pressure differential. tiffners prevent audible vibration during normal operation of air systems. Interior partitions are minimum 22 gauge galvanized steel perforated to remove no more than 15% of the area. Inorganic fiberglass acoustically absorptive filler material is compressed a minimum of 5% to eliminate voids and prevent setting and is vermin proof, moisture proof and odorless. H Incombustible filler material does not exceed the following fire and smoke hazard classification values when used in accordance with NFPA 90A and UL 181. W L TAG QTY W H L REMARK OPTION: High temperature sealant Field or factory assembled multiple modules TDF Flange one or both ends 1.5" (38) flange one or both ends 18 gauge (1.31) outer casing construction 12-15-05 1-20-06 5