Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Similar documents
Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

4 Port Solenoid Valve

4 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Series VQ Port Solenoid Valve

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve Direct Operated Poppet Type

Specifications. Fluid Ambient and fluid temperature ( C)

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air

3 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

Series VP3145/3165/3185

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Vacuum / Release Unit

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

Series VP3145/3165/3185

3 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Rubber Seal VP300/500/700

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series SYJ300/500/700

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Air Operated Valve

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

Compact Proportional Solenoid Valve

5 Port Solenoid Valve

Vacuum Equipment. Application. Series

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

SYA3000/5000/7000. How to Order SYA3000 SYA5000. Bracket One-touch fitting for ø8 G 1 4 With foot bracket. F1 One-touch fitting for ø8 SYA7000 G 1 8

3 Port Solenoid Valve

HN B G1/US B G2/US B G3

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series SYA3000/5000/7000

3 Port Solenoid Valve

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

3 Port Air Operated Valve VTA. Indicate VO for manifold. Port size. Nil 02 1/4. Specifications Fluid. Option Description Bracket (With screw)

Series SYA3000/5000/7000

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Series SYA3000/5000/7000

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

5 Port Air Operated Valve. Specifications. Flow characteristics 1 4/2(P A/B) Cv

Series SYA3000/5000/7000

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Series SV1000/2000/3000/4000

0.35 W (Without light)

3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS

Series VQZ1000/2000/3000 Single Unit

ISO Interface Solenoid Valve/SIZEq Metal Seal. Standard Specifications. Fluid Operating pressure. Ambient and fluid temperature

4/5 Port Solenoid Valve

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

New Concept Connector Type Manifold

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

SOLENOID VALVES, SERIES

S Y 3 A F NFZD

Transcription:

4 Port Direct Operated Poppet Solenoid Valve Series D1000 High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.MPa, subject to clean, dry air) Vacuum applications possible (up to 100kPa) S (Valve leakage: 0.0cm / He or less) Can be used for vacuum and vacuum release circuits. When used as a port valve, conversion from N.O. to N.C. and vice versa is possible by plugging either port 4(A) or 2(B). Compact and lightweight (4g) with large flow capacity Body width of 10mm, Cv0.0 2W (Standard) Cv0.08 4W (U type: Large flow) Clean room specifications available as special. Main valve has no sliding seals or grease and air is not exhausted to the atmosphere. 4 Z D S Body ported Copper free specifications standard Components of the valve that are in contact with fluid are all copper free. S Cylinder Speed Port size Effective area mm 2 (Cv) Cylinder speed (mm/s) Cylinder bore size (mm) Series CJ2 Pressure: 0.MPa Load ratio: 0% Cylinder stroke: 60mm Series CM2 Pressure: 0.MPa Load ratio: 0% Cylinder stroke: 00mm ø6 ø10 ø16 ø20 ø2 ø2 ø40 Note 1) Cylinder speed varies depending on piping and air component equipment used. Use the table as a guideline for selection. Note 2) Cylinder speed of CJ2 and CM2 is limited by the fixed orifice built-in. Note ) Cylinder speed: when the cylinder is extended. 10 D111U M X 0.8 (Large flow 1. capacity) (0.08) 00 40 600 70 Characteristic values mentioned in the catalog are typical values and are not to be guaranteed. 1.1-1

Precautions Be sure to read before handling. Refer to p.0- to 0-6 for Safety Instructions and common precautions. Warning Connected actuator is started by manual operation. Use the manual override after confirming that there is no danger. ø Wiring Specifications Caution Standard: 2W specification Lead wire Timer circuit For the 4W specification (power saver), power consumption at holding is reduced with the above circuit. Refer to the power wave form below. <Power saver style power wave form> (Rated voltage: 24V DC) 24V 0V 4W 2W 0W LED Applied voltage 10ms Manual Operation Non-locking push style (Flush) Diode ZNR In order to turn it ON, push down the manual override button in the direction the arrow ( ) indicates until it stops ( mm), and release it to turn it OFF. Coil Large flow capacity: 4W specification Coil LED Power saver Connector (+, ) Red A (+, ) Black C Lead wire Connector (+) Red A i1 i2 ( ) Black C i1: Inrush current i2: Holding current How to Use Plug Connector Caution Installation and removal of connector For installation of the connector, insert the connector straight on the pins of the solenoid, making sure that the lip of the lever is securely positioned in the groove of the cover and locked. To remove the connector, press the lever against the connector and pull connector away from the solenoid. Note: To avoid contact failure and broken wires, do not pull out the lead wire with excessive force. How to order connector assembly AXT661-14A- Lead wire length of plug connector valve with lead wire is 00mm. When lead wire length of 600mm or longer is required, order a valve without connector and order connector assembly separately. Caution Cover Groove Pin Connector Lead wire length of plug connector Lever Lead wire length 6 10 20 0 Lever Connector 00mm 600mm 1000mm 2000mm 000mm How to Use the Valve for Vacuum Applications (When used as a port valve) Application example of D111 V/W (Symbols used are typical.) Vacuum valve 4 Z D S S (R) 4(A) Vacuum pad Caution How to Mount Valve After confirming that the gasket is sung, tighten the mounting screws securely with the clamping torque shown in the table below. Appropriate clamping torque (Nm) 0.18 to 0.2 1(P) 2(B) Air for vacuum release atmosphere or air pressure Use a D111V/W valve for vacuum applications. Connect the vacuum source to the (R) port. Air pressure cannot be applied to the (R) port. When used as a port valve, conversion from N.O. to N.C. and vice versa is possible by plugging either port 4(A) or 2(B). Cannot be used as 2 port valve. 1.1-

4 Port Direct Operated Poppet Solenoid Valve Series D1000 How to Order D11 1 L 2 Body Body ported (Single unit) Body ported (Manifold) Sub-plate port size Body ported M M thread Without sub-plate (Manifold) M M thread V U W (1) (1) Valve option Standard (2W) Vacuum (2W) Large flow (4W) Large flow, Vacuum (4W) Note 1) Power saver type 6 Rated voltage 24V DC 12V DC Note) Consult SMC for other voltages. Electrical entry L: Plug lead L plug connector, With lead wire and light and surge suppressor LO: Plug lead L plug connector, Without lead wire and light and surge suppressor M: Plug lead M plug connector, With lead wire and light and surge suppressor MO: Plug lead M plug connector, Without lead wire and light and surge suppressor L plug connector M plug connector JIS Symbol 1.1-4 (A) (B) 4 2 1 (R) (P) L plug connector Body ported M plug connector Body ported Standard Specifications Item Valve specifications Solenoid specifications Model Valve structure Fluid Max. operating pressure Min. operating pressure/vacuum Effective area (Cv) Response time (1) Ambient and fluid temperature Lubrication Manual override Shock/Vibration resistance Mounting orientation Enclosure Weight Coil rated voltage DC Allowable voltage Type of coil insulation Power consumption DC Electrical entry Standard Large flow capacity (2W) (4W, Power Saver) 4 port direct operated poppet valve Air, lnert gas 0.7MPa 0MPa/ 100kPa 0.9mm 2 (Cv0.0) 1.mm 2 (Cv0.08) ON: 4ms, OFF: 2ms 10 to 0 C (2) Not required Non-locking push style 10/0m/s 2 () Free Dust proof 4g (Without sub-plate) 24V, 12V ±10% of rated voltage Class B or equivalent 4W (Power saving) 2W (Inrush: 4W, Holding: 2W) L plug connector, M plug connector (With light and surge voltage suppressor) Note 1) According to JISB87-1981. Factor: With light and surge suppressor (Subject to clean air). Dispersion accuracy: ±1ms Note 2) Operating the valve at low temperatures may cause condensate to form, therefore dry air must be used. Note ) Shock resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. Vibration resistance: No malfunction occurred in a one-sweep test between 8. and 2000Hz. Test was performed at both energized and de-energized states to the axis and right angle direction of the main valve and armature. (Value in the initial stage.)

Construction JIS Symbol (A) (B) 4 2 1 (R) (P) q u e!0 t r y i o w Component Parts No. q w e r t y u i o!0 Part name Solenoid coil assembly Sub-plate Body Spool valve Poppet Guide ring Return spring Manual override Gasket Round head screw Material Aluminum ZDC Aluminum NBR Resin Stainless steel Aluminum NBR Steel Note) Body cannot be disassembled. Note D1000-S-M( only) D1000-9-1 AXT62-7-1(M1.7 X 18) (R) 4(A) 1(P) 2(B) 1(P) Valve Single Unit Option Piping plate assembly D1000-20A Manifold style (D111) can be changed to single unit style (D1121) by mounting plate assembly. Note) Plate should be mounted with manifold mounting screws (M1.7 X 20). Tightening torque: 0.18 to 0.2Nm 4 Z D S S 1.1-

Dimensions L plug connector: D1121 - L-M M plug connector: D1121 - M-M Lead wire length: 00mm Light 2-M X 0.8 (A, B port) Direct manual override 4 0.6 0.6 1.. 1 6. (11) 4 0. 0. 2. 2 11 29 21. 4 28. 2-ø. Mounting hole 49 0. 2-M X 0.7 (P, R port) (R) 1 (P) 7.4 (1) 1.1-6

SMC Series D1000 Dimenisons L plug connector: D111 - L-M M plug connector: D111 - M-M 4(A) 2(B). Lead wire length: 00mm Light 27 Direct manual override 9 (R). 2-ø. Mounting hole 10.9 9.1 11.2 17.6 1(P) 12 28.. 7 1(P) 8 4 Z 4-M X 0.8 (P, A, B, R port) 1 49 0. M plug connector (M). L plug connector (L) D S S 1.1-7

How to Order Manifold How to Order Valve Plug lead unit manifold D11 1 L M VV4QD1 2 Manifold Body ported 20 20 stations (Max.) Cylinder ports ( only) M C4 02 Stations 2 stations M thread ø4 One-touch fitting 1(P), (R) port: Rc(PT)1/8 Body Body ported type type V U W Valve option Standard (2W) Vacuum (2W) Large flow (4W) Large flow, Vacuum (4W) Power saver Rated voltage 24V DC 6 12V DC Note) Consult SMC for other voltages. How to Order Manifold Assembly Specify the model numbers of valve and option together with the manifold base part number. <Example> Plug lead unit manifold VV4QD1-0M 1 set VD1000-10A- 1 set D111-L 4 sets Manifold base part number Blank plate part number (1st station) Valve part number (2 to th station) Put the mark at the beginning of the part number of valves, etc. to be mounted on the manifold. D side U side Station 1 2 4 Specify part numbers in order from the first station starting from the D side of the manifold. D111-L L: Plug lead L plug connector, With lead wire and light and surge voltage suppressor LO: Plug lead L plug connector, Without lead wire and light and surge voltage suppressor M: Plug lead M plug connector, With lead wire and light and surge voltage suppressor MO: Plug lead M plug connector, Without lead wire and light and surge voltage suppressor Electrical entry Port size (Body ported only) M M thread D1000-10A- R 1P 2B 4A 2B 4A VV4QD1-0M 1.1-8

Manifold Option Blank Plate Assembly/Body Ported VD1000-10A-2 Blank plate assembly includes 2 screws and 1 gasket. Blank Plate Assembly/Base Mounted VD1000-10A- Blank plate assembly includes 2 screws and 1 gasket. 4 Z D S S 1.1-9

Dimensions Plug lead unit manifold(vv4qd12- ) 4-Rc(PT)1/8 (P, R port) Lead wire length: 00mm Light 2-ø4. (Mounting hole). 2 0. 0 17 7 1 1 R P 6. 1 P R 0.6. 7 8 0. 0. P=11 L2 L1 10 4 2n-M (A, B port) M: M thread 42 M plug connector (M) D side Station 1 2 4 n U side Direct manual override (Non-locking) 1 24 4 L plug connector (L) Dimensions n: Station L n 1 2 4 6 7 8 9 10 11 12 1 14 1 16 17 18 19 20 L1 L2 28 20 9 1 0 42 61 72 64 8 7 94 86 10 97 116 108 127 119 18 10 149 141 160 12 171 16 182 174 19 18 204 196 21 207 226 218 27 229 1.1-10

Dimensions Plug lead manifold unit(vv4qd1- ) Lead wire length: 00mm 4-Rc(PT)1/8 (P, R port) ACB ACB ACB ACB ACB Light 2. 1 2 9 16 7. 17 (R) 1(P) (R) 1(P) 2-ø4. (Mounting hole) 10 6. 41. 4 4 P=11 L2 L1 10 4 M plug connector (M) 46 27. 20 1 D side U side Stations 1 2 4 n Direct manual override (Non-locking) 2(B) 4(A) P=11 2(B) 4(A) 12. 2n-C4, M (A, B port) C4: ø4 One-touch fitting M: M thread 4 Z D S S L plug connector (L) Dimensions L n 2 L1 L2 9 1 0 42 4 61 72 64 6 8 7 7 94 86 8 10 97 9 116 108 10 127 119 11 18 10 12 149 141 1 160 12 14 171 16 1 182 174 16 19 18 17 204 196 18 21 207 19 226 218 n: Station 20 27 229 1.1-11