COMBUSTION AND ENERGY

Similar documents
ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

INSTRUCTION MANUAL (ATEX / IECEx)

CCAI, CCAIF, CCAIF..H

INSTRUCTION MANUAL (ATEX / IECEx)

Floodlight LED Series 6125

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Solenoid coils VACF Type codes

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Emergency Light Fitting for Fluorescent Lamps Series 6009

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Floodlight LED Series 6525

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Linear luminaire with LED Series EXLUX 6002

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Terminal Boxes Series 8125

Terminal Boxes in Stainless Steel SLS**.T

New products Ex Equipment 2015

ABG Cable Glands Installation Procedure

Compact Sheet-Steel Light Fittings Series 6114/1

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Linear Luminaire with LED Series EXLUX 6002

Floodlight LED Series 6525

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Load disconnect switch Series 8146/5-V11

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

EX-D ENCLOSURES AND DISTRIBUTIONS

Control Stations CP.../EFDCN

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Sensor boxes SRBE Key features and product range overview

Control Buttons / Switches for Panel Mounting Series 8003

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

PY, SPY; FSQC, FP; EPC; AP

Position Switches Series 8074/2

Floodlight Series 6121

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Modular Explosion Proof Brakes. IECLine rev 0

Motors and drives for applications in explosive atmospheres

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Linear Luminaire with LED Series EXLUX 6402/2

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Integrated Control modules

VALIADIS S.A. HELLENIC MOTORS

ILED Dorado. User Manual

M-0. M-0... series control, monitoring and signalling devices. Ex e

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Linear fluorescent luminaire LED V-CG-S

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

YFC. Limit switch. Ex d. 24 operating head types

Leading the way in hazardous areas Features EATON

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Flameproof Enclosures

Flameproof Alternators

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Position Switches Series 8060/2

Explosion proof electric motor For Fuel dispensing application. Main characteristic

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

EWE. Ex de. Cooling fins

LED Linear Luminaire Series EXLUX 6402

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Operating Instructions

MECAIR PXA/PEX HAZARDOUS PILOTS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Emergency Luminaire with LED Series EXLUX 6409/1

Terminal Boxes TNCN. Explosion protection Marking

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Thermocouple For additional thermowell Model TC10-B

The safety you rely on.

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Floodlight Series 6521/4

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Position Switches Series 8070/2

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Explosion and flame-proof single phase electric motors

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Spring loaded resistance thermometer

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

8150 Series Terminal Boxes

Transcription:

CATALOGUE 2015 COMBUSTION AND ENERGY COMBUSTION AND ENERGY SRL VIA PER DOLZAGO, 21-23848 OGGIONO (LC) - ITALY - PH. +39 0 341.260926 - FAX +39 0 341.577747

INTERNATIONAL STANDARDS The ATEX directive consists of two EU directives describing what equipment and work environment is allowed in an environment with an explosive atmosphere. The Federal Aviation Administration (FAA) is the national aviation authority of the United States. An agency of the United States Department of Transportation, it has authority to regulate and oversee all aspects of American civil aviation. The International Civil Aviation Organization, is a specialized agency of the United Nations. It codifies the principles and techniques of international air navigation and fosters the planning and development of international air transport to ensure safe and orderly growth. Competency in Ex atmospheres is a global certification scheme for electrical and mechanical craftspersons and designers working in potentially explosive atmospheres. Safety Integrity Level is defined as a relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction. International Electrotechnical Commission system for certification to standards relating to equipment for use in EXplosive atmospheres (IECEX system).

TECHNICAL EJB SPECIFICATIONS Material: SS316 or aluminium Degree of protection: IP66 Temperature: -50 C to +60 C Standards: EN 60079-0 : 2009 / 60079-1 : 2007 / 60079-31 : 2009 IEC 60079-0 : 2011 / 60079-1 : 2007 / 60079-31 :2008 Ex Code: II 2 GD Ex d IIB T6/T5/T4 Gb Ex tb IIIC T85 C / T100 C / T135 C Db IP66 In accordance with the European Directive 94/9/EC (ATEX) for Zone1 / Zone2 / Zone 21 / Zone 22 Threaded Holes: Metric thread 1.5 / NPT Certificate Number: INERIS 14ATEX0002X IEC.Ex INE 14.0017X STRONG POINTS Laminated lid: more operative surface and flexibility Primary melting alloy Hinges available on long/short side Windows available on all boxes dimensions RFID/NFC tracking (Radio-frequency identification tag)

ALUMINIUM EJB DIMENSIONS TYPE EJB-A EJB-B EJB-C EJB-D EJB-E EJB-F EJB-G HEIGHT (H) EXTERNAL DIMENSIONS WIDTH (W) DEPTH (D) HEIGHT (H1) INTERNAL DIMENSIONS WIDTH (W1) DEPTH (D1) INTERNAL PLATE A FIXING HOLES WEIGHT FEET FIXING BOLTS B U T kg ØZ 314 250 172,5 227,5 163,5 127 215 150 241 180 10,9 M8 423 247 229 341 167 187 321 150 249 290 16,1 M8 488 413 259 382 307 202 335 275 413,5 336 35,6 M8 530 490 259 420,5 380,5 202 394 358 479,5 360 43,7 M8 593,5 539 314 474 419 233 446 391 559 400 80,2 M10 833 450 311 713 329 233 670 294 449 630 92,8 M10 833 613 314 714 493 233 670 450 604 630 123,1 M10 EJB-H 833 613 412 714 494 334 670 450 604 630 133,9 M10 All dimension are in mm. Dimensions and weight subject to change without any notice.

ALUMINIUM Ex ENCLOSURES BOTTOM VIEW INTERNAL PLATE A W1 D1 H1 H T B ø Z U FRONT VIEW SIDE VIEW D W COMBUSTION AND ENERGY - info@ce2k.com - www.ce2k.com - Ph. +39.0341.260926 Document is subject to change without any notice

STAINLESS STEEL 316L EJBS DIMENSIONS EXTERNAL DIMENSIONS INTERNAL DIMENSIONS INTERNAL PLATE FIXING HOLES WEIGHT FEET FIXING BOLTS TYPE HEIGHT (H) WIDTH (W) DEPTH (D) HEIGHT (H1) WIDTH (W1) DEPTH (D1) A B U T kg ØZ EJBS-A 319 254 171 235 170 141 225 160 252 175 32 M10 EJBS-B 429 254 231 245 170 196 335 160 252 290 42 M10 EJBS-C 491 416 252 390 315 217 380 305 397 336 80 M10 EJBS-D 536 496 251 430 390 216 420 380 472 360 99 M10 EJBS-E 601 546 266 495 440 221 475 420 531 400 144 M16 EJBS-F 846 461 311 735 350 266 715 330 441 630 180 M16 EJBS-G 836 616 308 725 505 253 715 495 612 630 281 M16 EJBS-H 836 616 403 725 505 348 715 495 612 630 309 M16 All dimension are in mm. Dimensions and weight subject to change without any notice.

STAINLESS STEEL 316L ENCLOSURES BOTTOM VIEW INTERNAL PLATE A W1 ø Z B U FRONT VIEW SIDE VIEW D1 T H H1 W D COMBUSTION AND ENERGY - info@ce2k.com - www.ce2k.com - Ph. +39.0341.260926 Document is subject to change without any notice

SPECIFIC EJB FEATURES S.NO. INERIS 14ATEX0002X CE 0080 Ex d IIB T...Gb II2GD Ex tb IIIC T... Db IP66 Via per Dolzago, 21 23848 Oggiono (LC) Italy EJB(*) U N =... V AC... HZ/DC T. amb. (**) P. dis.max.(***) W T. cable (****) Year of construction: Cable entries: See instructions S.NO. IECEx INE 14.0017X Ex d IIB T... Gb Via per Dolzago, 21 23848 Oggiono (LC) Italy EJB.. U N =... V AC... HZ/DC T. amb. (*) P. dis.max.(**)w Ex tb IIIC T... Db IP66 T. cable (**) Cable entries: See instructions Warnings: DO NOT OPEN WHEN ENERGIZED DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT. TYPE OF ENCLOSURES (*) EJB-A EJBS-A EJB-B EJBS-B EJB-C EJBS-C EJB-D EJBS-D EJB-E EJBS-E EJB-F EJBS-F EJB-G EJBS-G EJB-H EJBS-H MAX. AMBIENT TEMPERATURE (**) Gas T6 Dust T85 C MAXIMUM POWER DISSIPATED(***) 40 C 50 C 60 C CABLE TEMPERATURE (****) 80 W 60 W 35 W NC T5 T100 C 120 W 95 W 75 W 95 C T4 T135 C 205 W 180 W 155 W 135 C T6 T85 C 125 W 90 W 55 W 85 C T5 T100 C 180 W 145 W 110 W 100 C T4 T135 C 305 W 270 W 235 W 135 C T6 T85 C 210 W 150 W 95 W 85 C T5 T100 C 295 W 235 W 180 W 100 C T4 T135 C 500 W 440 W 380 W 135 C T6 T85 C 255 W 185 W 115 W 85 C T5 T100 C 360 W 290 W 220 W 100 C T4 T135 C 610 W 535 W 465 W 135 C T6 T85 C 275 W 200 W 125 W 95 C T5 T100 C 390 W 315 W 240 W 115 C T4 T135 C 655 W 580 W 505 W 160 C T6 T85 C 365 W 265 W 165 W 95 C T5 T100 C 515 W 415 W 315 W 115 C T4 T135 C 850 W 755 W 660 W 160 C T6 T85 C 430 W 315 W 195 W 95 C T5 T100 C 610 W 495 W 375 W 115 C T4 T135 C 1020 W 905 W 790 W 160 C T6 T85 C 535 W 390 W 245 W 95 C T5 T100 C 610 W 460 W 320 W 115 C T4 T135 C 1260 W 1120 W 975 W 160 C

TABLES NUMBER OF THREADED HOLES AND OPERATORS ON FRONT EJB Type A B C D E F G H Nr. of threaded holes and operators (M32 and M25) 12 15 24 25 30 42 42 42 NUMBER OF HOLES ON LONG/SHORT SIDE FOR EACH EJB ENTRY A B C BOX TYPE D E F G H M20 1/2 8/6 12/6 20/16 24/22 30/24 55/26 55/32 60/38 M25 3/4 8/4 6/2 12/9 22/16 25/20 38/18 40/22 44/24 M32 1 3/2 3/2 10/8 11/9 13/11 30/15 34/18 36/20 M50 1.1/2 2/1 2/1 4/3 8/8 8/8 14/6 16/12 17/13 M63 2 3/2 3/3 4/4 10/4 11/5 12/6 M75 2.1/2 2/2 2/2 3/2 4/2 6/4 6/4 M80 3 1/1 2/2 3/1 5/3 5/3 COMBUSTION AND ENERGY - info@ce2k.com - www.ce2k.com - Ph. +39.0341.260926 Document is subject to change without any notice

ATEX CERTIFICATE

IEC.Ex BODY CERTIFICATE COMBUSTION AND ENERGY - info@ce2k.com - www.ce2k.com - Ph. +39.0341.260926 Document is subject to change without any notice

Ex d IIC GUB ENCLOSURES FEATURES TECHNICAL SPECIFICATIONS Material: Aluminium Degree of protection: IP65 Temperature: -20 C to + 40 C or -20 C to + 70 C Standards: EN60079-0 / 60079-1 IEC 60079-0 / 60079-1 Ex Code: Ex II 2G Ex d IIC T6/T4 Compliant with the European Directive 94/9/EC (ATEX) for Zone 1 / Zone 2 Threaded Holes: Metric thread 1.5, ANSI B1.20.1 NPT, UNI 6125 Windows (option): Borosilicate Tempered Glass Certificate Number: INERIS 03ATEX0174X MANUFACTURER Combustion and Energy Srl Part number: Gub.. Gub..W

Ex d IIC GUB ENCLOSURES DIMENSIONS EXTERNAL DIMENSIONS INTERNAL DIMENSIONS WEIGHT GLASS WINDOW (Option) TYPE HEIGHT (H) WIDTH (W) LENGHT (L) HEIGHT (H1) WIDTH (W1) LENGHT (L1) kg mm GUB 1 GUB 2 GUB 3 150 170 170 108 142 142 5 105 180 198 198 132 170 170 7 135 190 220 258 142 192 230 9 135 L W W1 H1 H L1 COMBUSTION AND ENERGY - info@ce2k.com - www.ce2k.com - Ph. +39.0341.260926 Document is subject to change without any notice

ATEX CERTIFICATE

COMBUSTION AND ENERGY SRL Address: Via Per Dolzago, 21-23848 Oggiono (LC) - ITALY Legal office: Via Ponchielli, 7-20129 - Milano (MI) - ITALY Ph. +390 341.260926 E-Mail: info@ce2k.com info@luxsolar.com Web: www.ce2k.com www.luxsolar.com are trademarks of COMBUSTION AND ENERGY