SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker

Similar documents
SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker

Electrical network protection VIP30, VIP35. User s manual 12/2008

RM6. instructions for use. MV distribution factory built assemblies at your service ENGLISH

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Freedom egen System End-of- Line Functional Checklist

Protection and control VIP30, VIP35. Relays technical manual

Installation Instructions & Users Manual

Galaxy VM. Battery Breaker Box Installation 09/

Quick Start Guide TS 910 & TS 920

CALTRAP INSTALLATION AND OPERATIONS MANUAL

SM6. instructions for use. DMVL cubicle. MV distribution factory built assemblies at your service. Anglais

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

4.2 Component Identification

SM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

SM6. instructions for use. IMB cubicle without earthing switch. MV distribution factory built assemblies at your service. Anglais

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Operators Guide: RoboSign Stop/Go Traffic Control System

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Installation and Operating Instructions. Solar System Controller ISC3030

User Manual Solar Charge Controller 3KW

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

Quick Start Guide TS 910

Pulsar EXtreme CLA 1500C

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Operators Guide: RoboSign Stop/Go Traffic Control System

Installation and Operating Instructions. Solar System Controller ISC3020

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

TIMER INTERFACE USER MANUAL

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

User Guide for Viridian EV Charging Stations

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Electromagnetic Industries LLP

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

3 Phase Smart Controller

COUNTIS E22 Three-phase energy meter Direct - 80 A

WF-5110R True Sine Wave Inverter

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

AVOIDING ELECTROCUTION HAZARDS

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

User Manual. Solar Charge Controller 3KW

TX³ RCCBs 2P up to 100 A

Eclipse Solar Suitcase

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

OmniScan MX2. Getting Started Guide. Intended Use. Instruction Manual. Safety Signal Words

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

SM6. instructions for use. QMB cubicles. MV distribution factory built assemblies at your service. Anglais

INSTALLATION GUIDE AND USER MANUAL

Isolation Transformer for Medical Applications

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

Installation Instructions for Load Management Kit A051C329

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Extended Battery Cabinet for Nfinity

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

825-P Modular Protection System for motors Specification Guide

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

S&C Vista Underground Distribution Switchgear

Installation instruction

KD LV Motor Protection Relay

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Installing Power Components

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

The Traveler Series: Adventurer

MCset kv Medium voltage equipment

CBGS-0. Medium voltage distribution

Industrial Controls. Load Feeders and Motor Starters. SIRIUS MCU Motor Starters. Gerätehandbuch. Answers for industry.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Electrical Safety. Introduction

Medium Voltage Metal-Enclosed Switches

MASS COMBI 12/ (120V), 12/ (120V), 24/ (120V), 24/ (120V)

Installation Operation Parts

SM6. instructions for use. DM1 S cubicle. MV distribution factory built assemblies at your service. Anglais

AutoLink Frequently Asked Questions

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Medium Voltage Metal-Enclosed Switches

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Elmdene International Ltd

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

SM6. instructions for use. SM cubicle. MV distribution factory built assemblies at your service. Anglais

PBA Series Prelube Controls

MCset 4-24 kv Withdrawable SF6 circuit breaker

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Transcription:

SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker Instructions for use 11/2017 18 0 2 ing A r p s e l b a l i va

SFset- Instructions for use Table of contents Presentation Presentation... 2 General description... 2 RI control SFset circuit breaker... 2 RI control... 2 Control unit... 2 Identification... 3 Handling and storage... 3 Storage... 3 Handling... 3 Instructions for Putting into Operation the Protection Relay for Circuit- breaker... 4 VIP400 / VIP410... 4 Maintenance... 12 Preventive maintenance... 12 Location of prevention... 12 Maintenance of current sensors... 12 Maintenance of relays... 12 Corrective maintenance... 13 Spare units... 13 Changing a 24 kv CSa4 or CSb4 current sensor... 13 1

Presentation SFset - Instructions for use Presentation General description A: Circuit breaker B: Control unit C: Sensors DE31001a RI control SFset circuit breaker 24 kv A B C Position A1 and B1: Lateral Position C1: Frontal DE31002 RI control position A1 position B1 position C1 DE31003 Control unit circuit breaker (3) (2) (1) control unit The control unit consists of: (1) VIP type protective electronic relay, (2) Mitop trip, (3) Current sensors. 2

SFset- Instructions for use Presentation Handling and storage Identification Of the circuit breaker, the control and the auxiliaries Note: Consult the manual for circuit breaker SF1 no. 889146. Storage DE31007 The circuit breakers are shipped in position "O" (open) and with the control disabled. Store the devices in a dry, ventilated place, sheltered from rain, splashes of water and chemical agents. Cover the equipment with a tarpaulin or cover to effectively protect it against dust, debris, paint, etc. -40 C +70 C Handling Note: Consult the instructions for circuit breaker SF1 no. 889146. 3

Instructions for putting into operation the protection relay for circuit- breaker SFset - Instructions for use Instructions for Putting into Operation the Protection Relay for Circuit- breaker VIP400 / VIP410 Presentation The User-Machine Interface (UMI) on the front panel of VIP relays consists of a display, LEDs and keys. A sealable pivoting flap can prevent access to the setting keys by unauthorized persons. CAUTION The VIP parameters must be set correctly in order for the circuit-breaker function well. 1: display 2: status LEDs 3: fault indication LEDs 4: zone for a user-customizable label with pictograms of the fault indication LEDs 5: acknowledgement key 6: identification label 7: sealing ring 8: selection keys 9: key for selecting menus and testing LEDs. When the VIP is not supplied with power, this key can also be used to start the VIP from the battery in order to enter settings 10: menu pictograms 11: menu selection pointer 12: battery compartment and socket for connecting the pocket battery module 13: settings protective flap 14: confirm entry key 15: abort entry key 16: setting keys flap closed flap open 4

SFset- Instructions for use Instructions for putting into operation the protection relay for circuit-breaker Identification Zone The identification zone on the front panel enables a VIP to be identified. VIP400 1: identification code 2: reference 3: supply voltage 4: serial number VIP410 Precautions VIP installed in a cubicle Phase Current Sensors bbtransport VIP relays can be transported by all suitable means of transport in the usual conditions for cubicles. Storage conditions should be taken into consideration for a long period of transport. bbhandling If the cubicle is dropped, check the VIP s condition by visual inspection and energizing. bbstorage We recommend keeping the cubicle protective packaging for as long as possible. VIP relays, like all electronic units, should not be stored in a damp environment for more than one month. They should be energized as quickly as possible. If this is not possible, the cubicle reheating system should be activated. VIPs operate exclusively with dual core CSa4 (200 A primary) and CSb4 (630 A primary) current sensors. These sensors provide: bbthe VIP power supply, bbmetering of all 3 phase currents and the earth fault current. The use of dedicated sensors means the complete protection chain performance (sensor, VIP, Mitop trip unit) can be guaranteed. It is very easy to connect VIP relays to the CSa4 or CSb4 sensors by means of 2 prewired connectors from the sensors: : bb1 x 9-pin SUBD connector for metering the phase and earth fault currents, bb1 x 6-pin lockable connector for the VIP power supply. The CSa4 and CSb4 current sensors consist of 2 windings per phase : bbone winding providing the VIP power supply, bbthe other winding enabling the VIP to measure the phase currents. The earth fault current is measured by taking the sum of the 3 phase currents inside the sensor. 5

Instructions for putting into operation the protection relay for circuit- breaker SFset - Instructions for use Current sensor connection block diagram 1 : metering windings 2 : VIP power supply windings 3 : dual core CSa4 or CSb4 sensor Connection precautions DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS bbnever leave the current sensor secondary in open circuit. The high voltage that would result from opening the circuit is dangerous for the operator and for the equipment. bbnever disconnect the VIP protection relay current sensor connectors unless the MV circuit-breaker bbis in the open position and completely isolated. bbwear insulating gloves to avoid any contact with a conductor that has accidentally been energized. bbwear personal protective equipment in compliance with current regulations. Failure to follow these instructions will result in death or serious injury. 1 - Check that the MV circuit-breaker is in the open position or is not connected to the electrical network. 2 - Connect the 9-pin SUBD connector to connector E on the VIP and tighten the 2 mounting screws. 3 - Connect the 6-pin lockable connector to connector B on the VIP. 6

SFset- Instructions for use Instructions for putting into operation the protection relay for circuit-breaker Connecting the VIP to the Mitop Trip Unit The VIP protection relay is connected to the Mitop trip unit with a 2-pin prewired connector from the Mitop trip unit. Connect the lockable 2-pin connector to the VIP. Earthing DANGER HAZARD OF ELECTRIC SHOCK Connect the VIP to earth. Failure to follow these instructions can result in death, serious injury, or equipment damage. Status LEDs ref. wiring type of terminal screwdriver tightening torque bbgreen-yellow wire 6 mm² (AWG 10) bblug with internal diameter 4 mm (0.16 in.) maximum bblength < 0.5 m (20 in.) The status LEDs provide information about the VIP general status: M4 screw Pozidriv n 2 1,2...1,5 N.m (10.6...13 lbin.) pictogram function VIP400 VIP410 Green LED: auxiliary power supply present - Red LED permanently on: VIP unavailable (VIP in the fail- safe position). Red LED flashing: a failure has been detected but does not involve the VIP going into the fail-safe position. Yellow LED flashing: communication active - Fault Indication LEDs VIP relays have fault indication LEDs. They flash to indicate a fault, as shown in the table below. pictogram fault VIP400 VIP410 Detection of a fault by the phase overcurrent protection or in the event of tripping by the temporary test mode Detection of a fault by the earth fault protection Detection of a fault by the thermal overload protection Ext. Tripping by a volt- free contact connected to the external trip input - 7

Instructions for putting into operation the protection relay for circuit- breaker SFset - Instructions for use After a trip, the fault indication LEDs are powered by the battery embedded in the VIP or by the VIP410 auxiliary power supply. Fault indication by the LEDs can be stopped: bbby pressing the Reset key, bbautomatically by the reappearance of a current in the network higher than the pick- up current, bbautomatically after 24 hours, bbby remote control order via the communication (VIP410). For the first 3 LEDs, faster flashing may occur before the protection trips, to indicate the following information : pictogram overshoot Overshoot of the instantaneous set point for phase overcurrent protection (I> or I>> or I>>> pickup outputs) Overshoot of the instantaneous set point for earth fault protection (Io> or Io>> pick- up outputs) Overshoot of the alarm set point for thermal overload protection Note Display Menu Organization Selecting a Screen in a Menu In custom mode, the protection set points may not be assigned to the Mitop trip unit output. In this case, the fault indication LED may be active, without being associated with the circuit-breaker trip. Depending on the application, this can indicate the presence of a fault without tripping the circuit-breaker. The fault indication LED pictograms can be customized by sticking a label to the right of the LEDs. The display is an LCD unit. It is only back- lit on the VIP410, when the auxiliary power supply is present. Each VIP function is presented in a screen consisting of the following items: bb1 st line: symbols for electrical values or function name bb2 nd line: displays the values of measurements or parameters associated with the function bba menu pointer, on the left, it is pointing to the pictogram for the selected menu. All the data available in the VIP relay is divided between 3 menus: bbthe metering menu contains the current measurements, peak demand currents, load history, event records, fault trip counter and the breaking current history; bbthe protection menu contains the essential settings for setting up the protection functions; bbthe parameters menu contains the parameters that are used to adapt VIP operation to particular applications. When a VIP is new, all the parameters in this menu have a default value. The protection functions are operational even with the parameters menu default values. step 1 2 action Press the key to select one of the 3 menus. The menu pointer indicates the selected menu : : Metering menu : Protection menu : Parameters menu Press the or keys to scroll through the screens in the select menu, until the desired screen displayed. 8

SFset- Instructions for use Instructions for putting into operation the protection relay for circuit-breaker Default Screen Operation according to the Power Supply Mode (VIP400) Operation according to the Power Supply Mode (VIP410) Integral Battery A default screen is displayed automatically 3 minutes after the last keystroke. This default screen is the screen displaying the phase currents. The VIP400 is a stand- alone protection relay powered by its current sensors. When current is present in the medium- voltage (MV) network, the protections and the display work and it is possible to enter settings and view measurements. The current in the MV network on which the VIP operates is called the pick- up current. When no current is flowing through the circuit-breaker (for example circuit breaker open), or when the current in the MV network is too low, the VIP is off and nothing appears on its display. If current appears, the protection functions are activated and trip the circuit-breaker - or not - according to their settings. The additional time taken by the VIP to start when current appears is called the pickup time. More information on the value of the pick- up current and the pickup time are available in the VIP Function Characteristics Please consult the reference NRJED311206EN. The VIP410 is a relay with a dual power supply. It is powered both autonomously by its sensors and by the auxiliary power supply. Like for the VIP400, the self- powered supply allow the protection functions to work even if the auxiliary power supply fails. The auxiliary power supply is used to power functions that do not depend on the current being present in the MV network. These functions are marked in the function table (Please consult the reference NRJED311206EN). The auxiliary power supply must be present for the relay and the communication to work. The VIP has an integral battery. It is used to: b activate the user- machine interface in order to enter settings when the VIP is not supplied with power; b illuminate the fault indication LEDs when the VIP is no longer supplied with power after giving theopening order to the circuit-breaker; b power the internal calendar. When the VIP is not supplied with power: Pressing and holding down the key will activate battery- powered operation of the user- machine interface. It is then possible to access the menus in order to enter settings. In this case, the display turns off automatically after 3 minutes of inactivity on the keypad. b The protection functions are activated automatically if the current reappears. The integral battery plays no part in operating the protection functions. The protection functions work even when there is no battery. NOTE : b in battery operation mode, the VIP processor runs with a reduced clock frequency to ensure the battery life is maintained. As a result, the user-machine interface may be slower to react. b during a setting operation with the VIP powered by its internal battery alone, the clock display is not refreshed on screen. However the internal clock increments normally. 9

Instructions for putting into operation the protection relay for circuit- breaker SFset - Instructions for use Replacing the VIP Battery The battery should be removed when depleted and at the end of life of the VIP relay. It can be removed with the VIP energized. 1 : Open the settings protective flap. 2 : Lift the removable cover shielding the battery compartment using a flat blade screwdriver. 3 : Pull the battery compartment forward with the screwdriver. 4 : Remove the battery. Battery Recycling WARNING HAZARD OF EXPLOSION bbdo not recharge the battery. bbdo not short circuit the battery. bbdo not crush the battery. bbdo not disassemble the battery. bbdo not heat the battery above 100 C (212 F). bbdo not throw the battery into fire or water. Failure to follow these instructions can result in death, serious injury, or equipment damage. Battery Characteristics bb1/2 AA 3.6 V lithium battery bbmodel: LS14250 from SAFT bbstorage conditions: as defined in EN 60086-4 bbdo not use rechargeable batteries or other types of battery Replacement Procedure When depleted, the battery is replaced as follows: bb1 : Insert a battery with the above characteristics, respecting the polarity (+ facing up). bb2 : Re-close the battery compartment. bb3 : Replace the cover shielding the battery compartment. bb4 : Test the battery by pressing the Reset key for 2 to 3 seconds: the LEDs should remain on clearly without fading for the whole time the key is pressed. bb5 : Reset the VIP time if necessary. bb6 : Close the settings protective flap. Cleaning Product To clean the product (especially when dusting), simply use a damp cloth. 10

SFset- Instructions for use Instructions for putting into operation the protection relay for circuit-breaker Pocket Battery Module The pocket battery module is an accessory that can be connected to the front panel of VIP relays. It contains a battery that can be used to power the VIP in order to: b enter settings if the integral battery is missing and if the VIP is not powered by the current sensors; b test the VIP, please consult the reference NRJED311206EN; b display the cause of the last trip by the VIP please consult the reference NRJED311206EN; b more information on connecting the pocket battery module to the VIP is available in the Connection to the VIP please consult the reference NRJED311206EN. Battery Module The pocket battery module should only be used during maintenance or commissioning by qualified personnel and must never be left permanently connected to a running VIP. LV434206 NOTICE NRJED311206EN : Reference manual available on http://mt.schneider-electric.be or contact the service unit Schneider Electric for diagnostic and advice. 11

Maintenance Maintenance SFset - Instructions for use Preventive maintenance Location of prevention DE31015a. 24 kv 8 C B VIP relay Description Operations Supplies Tools B - VIP 400/410 Inspection test - Pocket battery Sensor 24 kv Dust removal Cloth - C - CSa4 - CSb4 type sensor Checking of connections - - Maintenance of current sensors DE31016a 24 kv bbyou are reminded of the dangers of high pressure cleaning processes. bbclean with a dry cloth. Maintenance of relays DE31017 bbyou are reminded of the dangers of high pressure cleaning processes bbclean with a dry cloth. 12

SFset- Instructions for use Corrective maintenance Maintenance Spare units Location and identification DE31018a. 8 C B VIP relay Changing a 24 kv CSa4 or CSb4 current sensor Description Necessary tools Observations B - VIP 400/410 Pozidriv n 1 Setting to be implemented by the operator screwdriver (2 N.m) Sensor 24 kv C - CSa4 - CSb4 type sensor BTR wrench 5 - Wrench 13 DE31045 DE31044 Mark and disconnect the wires underneath the cover. Unscrew and remove the 2 CHc M8 securing screws. Remove the sensor. Refitting DE31024 Ø 36 2 Ø 9 DE31045 20 b Input feeder or output feeder. b Two holes Ø9 for 2 CHc M8 screws. Torque that must be applied: 28 N.m. Reconnect the wires in line with the marking. Note: the protection will only function properly if the wires are correctly reconnected. 13

Schneider Electric SA Dieweg 3 1180 Bruxelles - Belgique Tel. : +33 (0)2 373 75 01 mt.schneider-electric.be As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. 2017 Schneider Electric. All rights reserved 07897543EN01 - Rev.04