Directional Seat Valve Series D4S (Denison)

Similar documents
Chapter 6: Check Valves

Chapter 6: Check Valves

Chapter 10: Valves for Pipe Mounting

Chapter 5: Flow Valves

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Pilot-Operated Directional Control Valves Series D3 - D11

Directional Control Valve Series 4D01 (DENISON)

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Directional Control Valve Series D3W Soft Shift

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Proportional Pressure Relief Valve Series RE*T

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Control Valves. General Description. Specifications. Ordering Information

Throttle Check Valve Series FM

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Directional Control Valve Series D1VW

ZRV. Direct Operated Check Valve Series ZRV (Denison)

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Chapter 2: Directional Control Valves

Directional Control Valve

Pilot-Operated Proportional DC Valve Series D*1FH

Chapter 5: Flow Valves

Chapter 8: Slip-In Cartridge Valves

Chapter 7: Sandwich Valves

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

NG06. General Size NG6 NG10 Design

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

Safety valves direct, pilot operated and cartridge execution

3/2 Solenoid Cartridge Valve, Size 6

DIRECTIONAL CONTROL VALVES CETOP3

ADH /3 AND 4/2

Directional Controls

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

General Specifications DRV DRV-Exm DRV-Exd

Type of operation Depending on requirement either one or two dry DC-solenoid,

DIRECTIONAL CONTROL VALVES CETOP3

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania

Proportional Throttle Valves Series TDL

SOLENOID VALVES AND PNEUMATIC VALVES

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

Proportional Pressure Reducing Valve PDM08130

Directional cartridge valve tight on both sides type 2URED6 3

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional pressure relief valve, pilot operated

2/2 Solenoid Cartridge Valve, Size 6

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Check-Q-meter type FD

ADH /3 AND 4/2

2/2 Solenoid Cartridge Valve, Size 10

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

Direct solenoid and solenoid pilot operated valves

Compact Proportional Solenoid Valve

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

6 to14/2 ways/positions bankable flow diverters flangeable

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Available manual, pneumatic, and hydraulic spool control kits.

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

6/2 ways/positions flow diverters

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Subplates (AP) and multi-station subplates

Axial Piston Variable Pump AA4VG

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Size 10 to 32 up to 35 MPa up to 1100 L/min

SOLENOID VALVES AND PNEUMATIC VALVES

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Pressure Control Valves

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

3/2-way Solenoid Valve for pneumatics

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Axial Piston Variable Pump A4VG

Q max (see specifications table)

Solenoid valve VDHT standard BSP (British Standard Pipe)

Transcription:

Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01) and position control - allow to design individual hydraulic solutions for nominal flow up to 00 l/min. A complete program is offered under the Denison brand: subplate mounted valves (D4S - chapter ), SAE flange valves (D5S - chapter 9), pipe mounted valves (D4S - chapter 10), slip-in cartridges (CAR - on request). Features Leak-free seat valve design Numerous pilot options poppet types 3 sizes, NG10, 25, 32 D4S10-21

Ordering Code D4S 9 B Seat valve Nominal size Subplate mounting ISO 24 Y1 port G¼" Pilot connection Cap version Sleeve Spool type Spring Switching type Solenoid voltage Design series Seals Options Code Nominal size 03 NG10 0 NG25 10 NG32 Code omit 013 Options Standard Cover for end position control Code Pilot oil line in body A-X B-Y 1 internal from A 2 internal from X A 1) internal from A B 1) external from X C internal from A + B D internal from B G external from Y 1) With VV01 only Code Ports X Y Z X-Y Y1 VV01 Standard 1 Pilot oil = pilot drain C Pilot oil = pilot drain With solenoid valve (VV01) 2 Ext. PD from cap Internal pilot drain With stroke limiter (not for D4S03) 3 Pilot oil = pilot drain 4 Pilot oil = pilot drain Code Sleeve 1 AA=95%, AB=5% 3 AA=0%, AB=40% Code Size Poppet type Sleeve 1 03, 0,10 With closed bottom and 15 chamfer (pz max. = pa +20bar 1 2 03 With 0.8 dia. orifice at the bottom and 15 chamfer 1 0, 10 With 1.2 dia. orifice at the bottom and 15 chamfer 1 4 03, 0,10 With closed bottom and 45 chamfer 1, 3 A 2) 0, 10 Safety spool (for position control only) 3 B 2) 0, 10 Throttle spool, 10 chamfer 3 C 2) 0, 10 Throttle spool, 3 chamfer 3 2) Springs 2, 3, 4 and only open bore closed bore orifice Ø 1.2-22 Code Solenoid voltage omit Standard G0R 12V= G0Q 24V= GAR 98V= GAG 205V= W0 115V / 50Hz W07 230V / 50Hz Code Switching type omit Standard 09 VV01 with manual override de-energized: power 10 VV01 without manual override comp. open 11 VV01 with manual override de-energized: power 12 VV01 without manual override comp. closed CA DA CB CD DB DD BH BK BN BQ BC BE BA BF BL Shuttle valve Shuttle valve Code Seals 1 NBR 5 FPM VV01 code 09 and shuttle valve code CA VV01 code 11 and shuttle valve code CA VV01 code 09 and shuttle valve code DA VV01 code 11 and shuttle valve code DA VV01 code 10 and shuttle valve code CA and position control 3) with amplifier VV01 code 12 and shuttle valve code CA and position control 3) with amplifier VV01 code 10 and shuttle valve code DA and position control 3) with amplifier VV01 code 12 and shuttle valve code DA and position control 3) with amplifier VV01 code 10 and position control 3) with amplifier VV01 code 12 and position control 3) with amplifier Position control 3) with amplifier Position control 3) with amplifier and shuttle valve code CA Position control 3) with amplifier and shuttle valve code DA 3) Position control for D4S0/10 only. Spring 2 or 4. Spool A and sleeve 3. Valve open: proximity switch damped. Spring (approx. cracking pressure [bar]) Code Sleeve Code 1 Sleeve Code 3 A -> B A -> B B -> A D5S03 D5S0/10 D5S03 D5S0/10 D5S03 D5S0/10 1 2.8 3.5.5.5 9.5 11.0 2 0.5 0.5 1.0 1.0 1.5 1.7 3 0.3 0.3 0. 0. 0.9 1.0 4 2.2 2.2 4.0 3.5 5.5.0 5 9.0 1.0 28.0 1.2 1.2 2.0 2.2 3.0 3.8 7 3.0 8.0 12.0

Technical Data General Size 03 0 10 Mounting Subplate mounting acc. to ISO 24 Mounting position unrestricted Ambient temperature [ C] -20...+50 Weight [kg] 2.7 4.5.0 Hydraulic Operating pressure [bar] Ports A, B up to 350; Port Y 140 (with VV01) Nominal flow [l/min] 180 30 00 Fluid Hydraulic oil as per DIN 51524...525 Fluid temperature [ C] -20...+80 Viscosity permitted [cst]/[mm 2 /s] 10...50 Viscosity recommended [cst]/[mm 2 /s] 30 Filtration ISO 440 (1999) 18/1/13 (acc. NAS 138: 7) Electrical (solenoid) Duty ratio [%] 100 Response time [ms] Energized / de-energized AC: 20/18, DC: 4/27 Code G0R G0Q GAR GAG W0 W07 Supply voltage [V] 12V = 24V = 98V = 205V = 150 at 50Hz 230 at 50Hz Tolerance supply voltage [%] +5...-10 +5...-10 +5...-10 +5...-10 +5...-10 +5...-10 Power consumption, hold [W] 31 31 31 31 78 78 Power consumption, in rush [W] 31 31 31 31 24 24 Max. switching frequency [1/h] AC: up to 7.200, DC: up to 1.000 Solenoid connection Connector as per EN175301-803 Protection class IP5 in accordance with EN 0529 (plugged and mounted) Coil insulation class H (180 C) D4S pilot configuration Subplate mounting -23

Characteristics p/q performance curves Selection of Cartridges Sleeve 1, poppet 1 Sleeve 1, poppet 2 Sleeve 1, poppet 4 Sleeve 3, poppet 4 Sleeve 3, poppet A Sleeve 3, poppet B/C 1 : 1.05 1 : 1.05 1 : 1.05 1 : 1.7 1 : 1.7 1 : 1.7 = 0.95 A C = 0.95 A C = 0.95 A C = 0. A C = 0. A C = 0. A C = 0.05 A C = 0.05 A C = 0.05 A C = 0.4 A C = 0.4 A C = 0.4 A C 15 chamfer 15 chamfer 45 chamfer 45 chamfer 45 chamfer 45 chamfer orifice safety spool throttle spool -24

Dimensions NG ISO-code X1 X2 X3 X4 X5 X X7 Y1 Y2 Y3 Y4 10 24-0-09-*-97 42.9 35.8 21.5-7.2 21.5 31.8.7 58.8 33.4 7.9 25 24-08-13-*-97 0.3 49.2 39.7-11.1 20. 44.5 79.4 73 39.7.4 32 24-10-17-*-97 84.2 7.5 59.5 42.1 1.7 24. 2.7 9.8 92.8 48.4 3.8 NG ISO-code B1 B2 H1 H2 H3 L1 L2 D1 D2 D3 t1 D4 t2 D5 D 10 24-0-09-*-97 87.3 33.35 83 21 45 29 94.8 15 7 7.1 8 M10 1 10.8 17 25 24-08-13-*-97 105 39.7 109.5 29 71.5 34.7 12.8 23.4 7.1 7.1 8 M10 18 10.8 17 32 24-10-17-*-97 120 48.4 120 29 82 30. 144.3 32 7.1 7.1 8 M10 20 10.8 17 NG ISO-code Bolt kit - DIN912 12.9 Surface finish NBR FPM 10 24-0-07-*-97 BK-M10 x 35-4pcs 3 Nm ±15% SK-R10MN50 SK-R10MV50 25 24-08-11-*-97 BK-M10 x 45-4pcs 3 Nm ±15% SK-R25MN50 SK-R25MV50 32 24-10-15-*-97 BK-M10 x 45-pcs 3 Nm ±15% SK-R32MN50 SK-R32MV50-25

Ordering Code Explanation (Examples) D4S direct operated D4S with VV01-2

Ordering Code Explanation (Examples) D4S with VV01 D4S with shuttle valve -27

Ordering Code Explanation (Examples) D4S with position control D4S with stroke limiter -28

Dimensions Dimensions D4S with VV01 Dimensions D4S with shuttle valve () Dimensions in brackets are for version VV01with shuttle valve code DB or DD. Note: Shuttle valves only use in connection with vent valve VV01. -29

Dimensions Dimensions D4S position control Technical data (proximity switch) Function PNP, contact Supply voltage (Us) [VDC] 10...30 Supply voltage ripple [%] 10 Current consumption [ma] max. 8 Residual voltage L-signal [V] Us - 2.2 at l max Output current (I) [ma] 200 Protection class IP7 Ambient temperature [C ] -25...+70 Wire cross section [mm 2 ] 3 x 0.5 Position control by proximity switch (incl. amplifier) Valve open: proximity switch activated. This proximity switch is pressure proof and has no wearing parts. Note Position control for D4S0 and D4S10 only. Dimensions D4S stroke limiter Note: Stroke limiter not for use with D4S03, vent valve VV01, shuttle valve and positon control. -30