Similar documents
LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

G3 (D) 3-way Globe Valve, Bronze Trim

B2 Series Characterized Control Valve, Non-Spring Return Actuator

G7150D, 3-Way, Diverting Flanged Globe Valve

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve

G6 C(S)(LCS) 2-way Pressure Compensated Flanged Globe Valve

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

G780, 3-Way, Mixing Flanged Globe Valve

G7100S, 3-Way, Mixing Flanged Globe Valve

G765, 3-Way, Mixing Flanged Globe Valve

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

G765, 3-Way, Mixing Flanged Globe Valve

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Versatile and Powerful

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6 Series 2-Way, Victaulic Butterfly Valve

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Versatile and Powerful

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Minimum 27 in-lb Torque

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Minimum 27 in-lb torque

High temperature characterized control valves

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

pressure independent characterized control tm

AF Series Spring Return Direct Coupled Actuator

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

AM Series Direct Coupled Actuator

LF Series At A Glance

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Torque min. 35 in-lb, for control of air dampers

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Minimum 18 in-lb Torque

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

VA9203-AGx / VA9203-Bxx / VA9203-GGx

TRF.. series spring return rotary actuators for CCV

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

AF24-MFT95 US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for Use with Honeywell Electronic Series 90, or a 0 to 135Ω input

Pressure Independent Characterized Control Valves (PICCV)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

FSAF24(-S) US, FSAF120(-S) US

Mounting Installation Instructions LM, NM, AM, GM

Installation Instructions

Pressure Independent Characterized Control Valves (PICCV)

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LF Series Spring Return Direct Coupled Actuator

ZG106 or ZG 107 bracket

Product Cross Reference

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Electronic Globe Valve Guide Specifications

Z2 050 Q -J +CQB 24 -SR -L

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies

2006 Product Range Overview. Belimo Project: One Bellevue Center, Seattle, Washington

NV Direct Coupled Globe Valve Actuator

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

GM Series Direct Coupled Actuator

PRESSURE INDEPENDENT CONTROL VALVES (PICCV& epiv)

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Installation Instructions

PRESSURE INDEPENDENT CONTROL VALVES (epiv & PICCV )

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

VB-7000 Series 1/2 to 2 Globe Valves

Belimo is the Worldwide Leader in Fire and Smoke Actuation

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Installation Instructions

LF Series Spring Return Direct Coupled Actuator

Features Globe Valve 2-Way & 3-Way Assembly Features:

MS Application. Features. Proportional Valve Actuator General Instructions

Pressure Independent Characterized Control Valves (PICCV)

Electronic Globe Valves

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

Electronic Pressure Independent Valves (epiv)

VB-9313 Series. Application. Features. Applicable Literature

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Butterfly Valves (BFV)

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

Electronic Ball Valve Guide Specifications

Zone Valves and Parts (Honeywell)

Erie VT/VS PopTop Series Two Position Spring Return Valves

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Accessories. UP timer. Timer control. Approvals. UP Series

VB-9213 Series. Application. Features. Applicable Literature

Commercial Actuator Selection Chart Non-Spring Return

Mounting Installation Instructions NKQ, GK

Transcription:

Technical Documentation all Valves Effective October 2008 elimo Project: ssisi Heights in ochester, Minnesota

all Valves all Valve Features and enefits 2...VS/VSS, 3...VS, 6...VS K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 2-way and 3-ay configuration ronze with stainless steel trim educed and full port capacities Two piece construction Electronic actuation NPT and Flanged connections ide C v range ir gap for use with hot water and steam systems Live load low maintenance stem packing 2 Year arranty 1

Flow Pattern, Operation and Installation all Valves Flow Pattern Closed CC Flow Direction Open C C to Flow Direction CC to Note: 3 VS are piped differently than 3 CCV Valves. VS Series all Valve Piping Diagrams Piping/Mounting Orientation ssembly can be mounted horizontally or vertically. Do not install with actuator below pipe. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 2

Piping Sizing Geometry all Valves Pipe Valve Valve Part 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 6.00 8.00 10.00 C Size v Type Number FpCv FpCv FpCv FpCv FpCv FpCv FpCv FpCv FpCv FpCv FpCv FpCv ½ 1 2 NPT 2VS 1.00 1.00 ½ 2 2 NPT 3VS 2.00 1.90 ½ 4 2 NPT 4VS 3.80 3.60 ½ 15 2 NPT 5VS 8.90 7.20 ¾ 30 2 NPT 9VS 30.00.60 17.40 15.60 ¾ 51 2 NPT 220VS 51.00 26.50 19.90 17.30 1 43 2 NPT 224VS 43.00 36.10 30.50 25.80 1 68 2 NPT 225VS 68.00 48.30 36.70 29.20 1¼ 48 2 NPT 2VS 48.00 44.60 37.90 35.00 1½ 84 2 NPT 9VS 84.00 69.70 59.60 55.40 1½ 177 2 NPT 240VS 177.00 102.70 77.90 67.30 2 108 2 NPT 249VS 108.00 100.40 91.80 83.20 2 389 2 NPT 250VS 389.00 2.70 159.50 124.50 2½ 503 2 NPT 265VS 503.00 352.10 2.30 186.10 3 370 2 NPT 280VS 370.00 296.00 251.60 229.40 ½ 5 3 NPT 315VS 4.40 4.10 ¾ 11 3 NPT 320VS 11.00 10.30 1 3 NPT 325VS.00 20.20 18.90 17.60 1¼ 33 3 NPT 332VS 33.00 32.00 29.00 27.70 1½ 49 3 NPT 340VS 49.00 45.60 42.60 40.70 2 91 3 NPT 350VS 91.00 86.50 81.00 74.60 2 330 2 FLG 650VS 330.00 207.90 155.10 122.10 2½ 420 2 FLG 665VS 420.00 319.20 4.20 184.80 3 600 2 FLG 680VS 600.00 384.00 300.00 264.00 4 1200 2 FLG 6100VS 1200.00 804.00 600.00 480.00 6 3300 2 FLG 6150VS 3300.00 1716.00 1254.00 8 9000 2 FLG 6200VS 9000.00 3870.00 10 12400 2 FLG 6250VS 12400.00 Fp Cv also apply to VSS where applicable. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 3

iring Instructions all Valves General iring Instructions NING The wiring technician must be trained and experienced with electronic circuits. Disconnect power supply before attempting any wiring connections or changes. Make all connections in accordance with wiring diagrams and follow all applicable local and national codes. Provide disconnect and overload protection as required. Use copper, twisted pair, conductors only. If using electrical conduit, the attachment to the actuator must be made with flexible conduit. lways read the controller manufacturer s installation literature carefully before making any connections. Follow all instructions in this literature. If you have any questions, contact the controller manufacturer and/or elimo. Transformer(s) Typically actuators require a 24 VC class 2 transformer and draw a maximum of 10 V per actuator. The actuator enclosure cannot be opened in the field, there are no parts or components to be replaced or repaired. EMC directive: 89/336/EEC Software class : Mode of operation type 1 Low voltage directive: 73//EEC Typical transformer sizing ctuator Series Voltage Max. V Per ctuator F 24 10 NF 24 10 LF 24 6 GM 24 7 M 24 6 NM 24 4 LM 24 3 CUTION It is good practice to power electronic or digital controllers from a separate power transformer than that used for actuators or other end devices. The power supply design in our actuators and other end devices use half wave rectification. Some controllers use full wave rectification. hen these two different types of power supplies are connected to the same power transformer and the DC commons are connected together, a short circuit is created across one of the diodes in the full wave power supply, damaging the controller. Only use a single power transformer to power the controller and actuator if you know the controller power supply uses half wave rectification. Multiple actuators, one transformer Multiple actuators may be powered from one transformer provided the following rules are followed: 1. The TOTL current draw of the actuators (V rating) is less than or equal to the rating of the transformer. 2. Polarity on the secondary of the transformer is strictly followed. This means that all No. 1 wires from all actuators are connected to the common leg on the transformer and all No. 2 wires from all actuators are connected to the hotleg. Mixing wire No. 1 & 2 on one leg of the transformer will result in erratic operation or failure of the actuator and/or controls. Multiple actuators, multiple transformers Multiple actuators positioned by the same control signal may be powered from multiple transformers provided the following rules are followed: 1. The transformers are properly sized. 2. ll No. 1 wires from all actuators are tied together and tied to the negative leg of the control signal. See wiring diagram. ire Type and ire Installation Tips For most installations, 18 or 16 Ga. cable works well with elimo actuators. Use code-approved wire nuts, terminal strips or solderless connectors where wires are joined. It is good practice to run control wires unspliced from the actuator to the controller. If splices are unavoidable, make sure the splice can be reached for possible maintenance. Tape and/or wire-tie the splice to reduce the possibility of the splice being inadvertently pulled apart. ire length for actuator installation Keep power wire runs below the lengths listed in the following tables. If more than one actuator is powered from the same wire run, divide the allowable wire length by the number of actuators to determine the maximum run to any single actuator. See section 1 for specific transformer sizing information for the actuator selected. Example: 3 actuators, 16 Ga wire 350 Ft 3 ctuators = 117 Ft. Maximum wire run K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 4

Nomenclature all Valves 2 24 VS MX 24 -MFTX1 Valve 2 = 2-way 3 = 3-way 6 = 2-way Flanged Valve Size 12-80 = 1/2 3 50-250 = 2 10 (Flanged) Trim Material VS = ronze or Cast Iron ody, Stainless Steel all and Stem VSS = Stainless Steel ody, all and Stem ctuator Type Non-Spring eturn LM NM M GM SY SY P Spring eturn LF NF F SY Power Supply 24 = 24 VC/DC 120 = 120 VC 0 = 0 VC Control -3X1 = On/Off, Floating Point -MFTX1 = Multi-Function Technology -MFT95 = 0-135 Ω -S = uilt-in uxiliary Switch Ordering Example K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 1 Choose the valve actuator combination. 224VS+MX24-MFTX1 +NO +Tagging (if needed) 2 Specify preference or configuration. Non-Spring Models NO = Normally Open NC = Normally Closed Spring eturn Models NO/FO = Normally Open/Fail Open NO/FC = Normally Open/Fail Closed NC/FO = Normally Closed/Fail Open NC/FC = Normally Closed/Fail Closed efers to valve ports to. 3 Set-Up For MFT orders only - select programming code P-10001 (01) P-100xx (xx) Control voltage applications P-200xx (xx) Pulse width modulation applications P-300xx (Fxx) P-400xx (Jxx) X-XXXXX X-XXXXX Floating Point applications On/Off applications Create custom MFT configuration code Create custom MFT configuration in the field with MFT-actuator PC software Does order require tagging? Tagging: Valves may be tagged per customer specification. Example: HU-1 FCU-2 4 5 Complete Ordering Example: 224VS+MX24-MFTX1+NO+01 5

2...VS Series, 2-ay, all Valve ronze ody, Stainless Steel all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design Technical Data Media Chilled or hot water, glycol, 35# steam Flow Characteristic Modified equal percentage ction 90 rotation valve open C, valve closed CC Sizes ½, ¾, 1, 1¼, 1½, 2, 2½, 3 Type of end fitting SE NPT (Female Connections) Materials: 1 Stem Packing einforced PTFE 2 Stem earing einforced PTFE 3 all 316 Stainless Steel 4 Seat (x2) einforced PTFE w/ Durafill 5 etainer 16 (¾ - 1 ) rass 584 (1¼ - 3 ) rass 6 Gland 16 rass 7 Stem 316 Stainless Steel 8 Jam Nut Stainless Steel 9 ody Seal PTFE (1-1/4 to 3 ) 10 ody 584-C84400 ronze pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV ox re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. Up to 35 psi steam 1/2-600 PSIG OG, Cold Non-Shock. Federal Specification: -V-35C,Type II Composition: Z Style: 3 Valve Nominal Size Type Suitable eturn ctuators C v Inches DN [mm] 2-way NPT Spring Non-Spring 1 ½ 15 2VS 2 ½ 15 3VS 4 ½ 15 4VS 15 ½ 15 5VS 30 ¾ 20 9VS 51 ¾ 20 220VS 43 1 25 224VS 68 1 25 225VS 48 1¼ 32 2VS 84 1½ 40 9VS 177 1½ 40 240VS 108 2 50 249VS 389 2 50 250VS 503 2½ 65 265VS 370 3 80 280VS LF Series NF F Series LM Series NM M Series GM Series SY Series Pressure rating 600 psig OG Media temp. range -22 F to 280 F (-30 C to 138 C) Close-off pressure 600 psig @ 100 F Maximum differential <600 psig pressure ( P) Flow Patterns K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 6

2...VSS Series, 2-ay, all Valve Stainless Steel ody, all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design pplication These threaded valves are designed to provide modulating or two position control of hot or chilled water and saturated steam systems under 50 psi. Typical applications include reheat coils, vav terminal control, unit ventilators, and air handlers, especially in areas which have minimum profile requirements. Up to 50 psi steam 1/2-2000 PSIG OG, Cold Non-Shock. Federal Specification: -V-35C,Type II, Composition: SS Style: 3 Technical Data Media Chilled or hot water, glycol, 50# steam Flow Characteristic Modified equal percentage ction 90 rotation valve open C, valve closed CC Sizes ½, ¾, 1, 1¼, 1½, 2, 2½ Type of end fitting SE NPT (Female Connections) Materials: 1 Stem Packing einforced PTFE 2 Stem earing einforced PTFE 3 all 316 Stainless Steel 4 Seat (x2) einforced PTFE w/ Durafill 5 etainer 16 (¾ - 1 ) rass 584 (1¼ - 3 ) rass 6 Gland 276-316 7 Stem 316 Stainless Steel 8 Jam Nut Stainless Steel 9 ody Seal PTFE (1¼ to 3 ) 10 ody 351-CF8M 316 Stainless Steel Valve Nominal Size Type Suitable eturn ctuators C v Inches DN [mm] 2-way NPT Spring Non- Spring 15 ½ 15 5VSS 30 ¾ 20 9VSS 43 1 25 224VSS 48 1¼ 32 2VSS 84 1½ 40 9VSS 108 2 50 249VSS 503 2½ 65 265VSS LF Series F Series NM Series M Series GM Series SY Series K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Pressure rating 2000 psig OG (½ - 1 ) Media temp. range -22 F to 298 F (-30 C to 148 C) Close-off pressure 600 psig @ 100 F Maximum differential <600 psig pressure ( P) Flow Patterns 7

3...VS Series, 3-ay, all Valve ronze ody, Stainless Steel all and Stem 316 Stainless all and Stem einforced PTFE seats and stuffing box low-out proof stem design djustable packing gland pplication These threaded valves are designed to provide modulating or two position control of hot or chilled water. Typical applications include reheat coils, vav terminal control, unit ventilators, and air handlers, especially in areas which have minimum profile requirements. 400 PSIG OG, Cold Non-Shock Technical Data Media Chilled or hot water, glycol Flow Characteristic Modified equal percentage ction 90 rotation to open CC, to open C Sizes ½, ¾, 1, 1¼, 1½, 2 Type of end fitting SE NPT (Female Connection) Materials: 1 Stem Packing PTFE 2 Stem earing PTFE 3 all 316 Stainless Steel 4 Seat (x2) PTFE w/ Durafill 5 etainer 16 (½ - 1 ) rass 584 (1¼ - 2 ) rass 6 Gland STM 16 rass 7 Stem 316 Stainless steel 8 Jam Nut PTFE (1¼ - 2 ) 9 ody Seal 584-C84400 ronze Valve Nominal Size Type Suitable eturn ctuators C v Inches DN [mm] 3-way NPT Spring Non-Spring 4.8 ½ 15 315VS 11 ¾ 20 320VS 1 25 325VS 33 1¼ 32 332VS 49 1½ 40 340VS 91 2 50 350VS LF NF F Series NF LM NM Series M GM Series Pressure rating 400 psig OG Media temp. range -22 F to 250 F (-30 C to 120 C) Close-off pressure 400 psig @ 100 F Maximum differential <75 psig pressure ( P) Flow Patterns K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 8

6...VS Series, 2-ay, all Valve Cast Iron ody, Stainless Steel all and Stem Same end to end dimension as conventional flanged iron gate valve Fast quarter turn open or closed operation Stainless steel ball and stem Positive shut-off Two-piece body construction Technical Data Media Chilled or hot water, glycol, 50# steam Flow Characteristic Modified equal percentage ction 90% rotation valve open C, valve closed CC Sizes 2, 2½, 3, 4, 6, 8, 10 Type of end fittings Flanged 125# NSI olt Pattern Materials: 1 ody Cast Iron - STM 126 Class 2 End Cap Cast Iron - STM 126 Class 3 all 304 Stainless Steel - STM 351 4 Seats PTFE 5 Stem 304 Stainless Steel - ISI 304 6 Packing PTFE 7 Gland Cast Iron - STM 126 Class 8 Gasket PTFE 9 Nut Steel - STM 6 pplication Ideal for water service where a non-corrosive, clean cosmetic appearance is required. Optional FD approval, suitable for potable water and food contact. Sizes: 2-10 (50-250mm) 200 psi CP (cold water pressure) (non-shock) pproved valves shall comply with the merican Standard for face-to-face dimensions (NSI 16.10) for Class 125 cast iron flanged gate valves. The dimensions and drilling of end flanges conform to the merican cast iron flange standard, Class 125 (NSI 16.1). Suitable eturn Valve Nominal Size Type ctuators C v Inches DN [mm] 2-way NPT Non-Spring 330 2 50 650VS 420 2½ 65 665VS 600 3 80 680VS 1200 4 100 6100VS 3300 6 150 6150VS 9000 8 203 6200VS 12400 10 254 6250VS SY Series K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Pressure rating 200 psig OG Media temp. range -22 F to 298 F (-30 C to 148 C) Close-off pressure 200 psig @ 140 F Maximum differential <200 psi pressure ( P) 9

K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 10

all Valve Product ange Overview VS/VSS all Valve Product ange 2...VS/VSS, 3...VS, 6...VS K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Valve Nominal Size Type Suitable ctuators C v Inches DN [mm] 2-way NPT 1 ½ 15 2VS 2 ½ 15 3VS 4 ½ 15 4VS 15 ½ 15 5VS 30 ¾ 20 9VS 51 ¾ 20 220VS 43 1 25 224VS 68 1 25 225VS 48 1¼ 32 2VS 84 1½ 40 9VS 177 1½ 40 240VS 108 2 50 249VS 389 2 50 250VS 503 2½ 65 265VS 370 3 80 280VS 15 ½ 15 5VSS 30 ¾ 20 9VSS 43 1 25 224VSS 48 1¼ 32 2VSS 84 1½ 40 9VSS 108 2 50 249VSS 503 2½ 65 265VSS 3-way NPT 4.8 ½ 15 315VS 11 ¾ 20 320VS 1 25 325VS 33 1¼ 32 332VS 49 1½ 40 340VS 91 2 50 350VS 2-ay Flanged 330 2 50 650VS 420 2½ 65 665VS 600 3 80 680VS 1200 4 100 6100VS 3300 6 150 6150VS 9000 8 203 6200VS 12400 10 254 6250VS LF Spring eturn LF Series NF Series F Series LF Series F Series NF F Series NF Non-Spring eturn LM Series NM Series M Series GM Series NM Series M Series GM Series LM NM Series M GM Series SY Series SY Series pplications ater-side control of air handling apparatus in ventilation and air-conditioning systems ater/steam control in heating systems Mode of Operation The control valve is operated by an electronic actuator that responds to a standard voltage for on/off control, by a proportional VDC/4 20 m, or 3-point control system. The actuator will then move the ball to the valve to the position dictated by the contol signal thus change the flow. Product Features Modified equal percentage of flow for 2, 3 and 6. Modified linear flow for 3. ctuator Specifications Control type M Manual override Electrical connection Valve Specifications Service Flow characteristic On/Off, Floating Point, Proportional, 2-10 VDC multi-function Technology (MFT) LM, NM, GM, M, SY, F 3 ft [1m] cable with ½ conduit fitting chilled or hot water, 60% glycol or steam modified equal percentage (2-way), modified linear (3-way) Sizes 1 to 10 Type of end fitting NPT (2 & 3 VS) flanged (6VS) Materials ody bronze (2 & 3VS), stainless steel (2VSS), cast iron (6VS) Stem stainless steel Seats PTFe Packing PTFE Pressure rating 600 psi Media temp range 2, 3VS -22 F to 280 F [-30 C to 138 C] 2VSS -22 F to 298 F [-30 C to 148 C] Maximum inlet pressure Steam 35 psi 2VS 50 psi 2VSS, 6VS 11

LF ctuators, On/Off Dimensions with 2-ay Valve Models LF24 US LF24-S US LF120 US LF120-S US w/built-in ux. Switch w/built-in ux. Switch Technical Data Control On/Off, Floating Power supply LF24(-S) US 24 VC ± 20% 50/60 Hz 24 VDC ± 10% LF120(-S) US 120 VC ± 10% 50/60 Hz Power consumption LF24(-S) US running 5 holding 2.5 LF120(-S) US running 5.5 holding 3.5 Transformer sizing LF24(-S) US 7 V, class 2 power source LF120(-S) US Electrical connection (-S models have 2 cables) ½ conduit connector 3 ft [1m], 18 G appliance cable Electrical protection 120V actuators double insulated Overload protection electronic throughout rotation ngle of rotation 95 Spring return direction reversible with C/CC mounting Position indication visual indicator 0 to 90 unning time <40 to 75 sec. (on-off) spring <25 sec. @-4 F to 122 F [-20 C to 50 C] <60 sec. @-22 F [-30 C] mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 gency listings UL 873, CS C22.2 No. 24 certified, CE Quality standard ISO 9001 Noise level max. 62 d() LF...-S US uxiliary switch 1 x SPDT, 6 (1.5) @ 250 VC, UL Listed, adjustable 0 to 95 (double insulated) ated impulse voltage 800V (4kV for 120V model), Control pollution degree 3, Type of action 1. (1.. for -S models) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 2VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 3VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 4VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 5VS 50 ½ 15 6.70 2.00 8.00 2.25 6.25 5VSS 1000 ½ 15 6.70 2.00 8.00 2.25 6.25 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 315VS 75 ½ 15 6.50 2.00 8.00 2.30 1.25 3.86 PGE11 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 12

LF ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuator may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., LF24-S US and LF120-S US incorporates a built-in auxiliary switch: 1 x SPDT, 6 (1.5) @ 250 VC, UL listed, adjustable 0 to 95. 1 Common 2 + Hot 3 LF24 US 2 On/Off wiring for 24 VC/DC 047 049-LF-08 Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off wiring for 120 VC 048-UX uxiliary Switch K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 13

LF24-MFT US ctuators, Multi-Function Technology Dimensions with 2-ay Valve Models LF24-MFT US LF24-MFT-S US w/built-in ux. Switch Technical Data Control MFT Control signal 2 to 10 VDC (4-20m with 500 Ω resistor) Power consumption running 2.5 holding 1 Transformer sizing 5 V (class 2 power source) Electrical connection (-S models have 2 cables) ½ conduit connector 3 ft [1m], 18 G appliance cable Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20m 750 Ω for PM 500 Ω for on/off and floating point Feedback 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of rotation spring reversible with C/CC mounting motor reversible with built-in switch Position indication visual indicator unning time <40 to 75 sec. (on-off) 150 sec. independent of load (proportional) spring <25 sec. @-4 F to 122 F [-20 C to 50 C] <60 sec. @-22 F [-30 C] mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 gency listings UL 873, CS C22.2 No. 24 certified, CE Noise level max. 62 d() Quality standard ISO 9001 LF24-MFT-S US uxiliary switch 1 x SPDT, 6 (1.5) @ 250 VC, UL Listed, adjustable 0 to 95 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 2VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 3VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 4VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 5VS 50 ½ 15 6.70 2.00 8.00 2.25 6.25 5VSS 1000 ½ 15 6.70 2.00 8.00 2.25 6.25 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 315VS 75 ½ 15 6.50 2.00 8.00 2.30 1.25 3.86 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 14

LF24-MFT US ctuators, Multi-Function Technology iring Diagrams 24 VC/DC Transformer 043 2 CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position ( ) Feedback VDC (+) a (1) Common (2) Hot (3) y input (5) u output 3 ctuators may also be powered by 24 VDC. CC C MFT 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. On/Off control (C only) 7 Position Feedback VDC ( ) (+) 6 (1) Common (2) + Hot (3) y input (5) u output 041 The ZG-01 500 Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. CC C MFT NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PM, triac source and sink 302 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Floating Point control Propotional 2 to 10 or 4 to 20 m control signal 303 15

NF ctuators, On/Off Dimensions with 2-ay Valve Models NF24 US NF24-S US NF120 US NF120-S US w/built-in ux. Switch w/built-in ux. Switch Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 9VS 400 ¾ 20 7.00 2.00 8.00 3.37 6.25 220VS 200 ¾ 20 7.00 2.00 8.00 3.37 6.25 Technical Data Control On/Off Power consumption NF24(-S) US running 5 holding 2.6 NF120(-S) US running 6 holding 3.5 Transformer sizing 10 V, class 2 power Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft [1m], 18 G appliance cables Electrical protection 120 V actuators double insulated Overload protection electronic throughout 0 to 95 rotation ngle of rotation 95 Position indication visual indicator unning time control <75 sec. spring <60 sec. mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C22.2 No. 24 certified, CE Noise level max. 45 d() NF...-S US uxiliary switch 1 x SPDT, 7 (2.5) @ 250 VC, UL listed, adjustable 5 to 85 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 320VS 75 ¾ 20 7.00 2.00 8.00 3.56 1.88 3.86 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 16

NF ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuators may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., NF24-S US incorporates a built-in auxiliary switch: 1 x SPDT, 7 (2.5) @ 250 VC, UL listed, adjustable 5 to 85. 1 Common 2 + Hot 3 NF24 US 2 On/Off iring for 24 VC/DC 194_NF 003-NF-08 Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off iring for 120 VC S1 NF120 US 1 224 S2 S3 NC NO 5 to 85 NF -S US uxiliary Switch K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 17

NF ctuators, Multi-Function Technology Dimensions with 2-ay Valve Models NF24-MFT US Technical Data Control MFT Control signal 2 to 10 VDC, (4 to 20 m with 500 Ω resistor) Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 6 holding 1.8 Transformer sizing 10 V, class 2 power Electrical connection ½ conduit connector 3 ft [1m], 18 G appliance cable Overload protection electronic throughout rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 1500 Ω for on/off and floating point Feedback output 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of otation spring reversible with C/CC mounting motor reversible with built-in switch Position indication visual indicator, 0 to 95 unning time control 150 sec. constant spring <60 sec. mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 / IP54 gency listings UL 873 listed, CS C22.2 No. 24 certified, CE Noise level less than 45 d() Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 9VS 400 ¾ 20 7.00 2.00 8.00 3.37 6.25 220VS 200 ¾ 20 7.00 2.00 8.00 3.37 6.25 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 320VS 75 ¾ 20 7.00 2.00 8.00 3.56 1.88 3.86 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 18

NF ctuators, Multi-Function Technology iring Diagrams to live electrical components could result in death or serious injury. 24 VC/DC Transformer 043 2 CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position ( ) Feedback VDC (+) a (1) Common (2) Hot (3) y input (5) u output 3 ctuators may also be powered by 24 VDC. 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). On/Off control CC C MFT 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. (C only) 7 Position Feedback VDC ( ) (+) 6 (1) Common (2) + Hot (3) y input (5) u output 041 The ZG-01 500 Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PM, triac source and sink CC C MFT 302 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Floating Point control Propotional 2 to 10 or 4 to 20 m control signal 303 19

F ctuators, On/Off Dimensions with 2-ay Valve Models F24 US F24-S US F120 US F120-S US w/built-in ux. Switches w/built-in ux. Switches Technical Data Control On/Off Power consumption F24(-S) US running 5 holding 1.5 F120(-S) US running 6 holding 2.3 Transformer sizing 10 V, class 2 power Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft [1m], 18 G appliance cables Electrical protection 120 V actuators double insulated Overload protection electronic throughout 0 to 95 rotation ngle of rotation 95 Position indication visual indicator Manual override hex crank unning time control 150 sec. independent of load spring <20 sec. mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C22.2 No. 24 certified, CE Noise level max. 45 d() F...-S US uxiliary switches * Dual Mounted ctuators 2 x SPDT, 7 (2.5) @ 250 VC, UL listed, one switch is fixed at +5, one is adjustable 25 to 85 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 224VS 400 1 25 7.00 2.00 8.00 3.37 6.25 225VS 50 1 25 7.00 2.00 8.00 3.62 6.25 2VS 200 1¼ 32 7.25 2.00 8.00 3.97 6.25 *9VS 400 1½ 40 7.50 3.00 8.00 4.37 6.25 *240VS 50 1½ 40 7.50 3.00 8.00 4.75 6.25 *249VS 200 2 50 8.00 3.00 8.00 4.68 6.25 9VSS 1000 ¾ 20 6.70 2.00 8.00 2.25 6.25 224VSS 1000 1 25 7.00 2.00 8.00 3.37 6.25 2VSS 400 1¼ 32 7.25 2.00 8.00 3.97 6.25 *2VSS 1000 1¼ 32 7.25 2.00 8.00 3.97 6.25 *9VSS 1000 1½ 40 6.70 3.00 8.00 4.37 6.25 *249VSS 400 2 50 8.00 3.00 8.00 4.68 6.25 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 325VS 75 1 25 7.00 2.00 8.00 3.56 1.88 3.86 332VS 75 1¼ 32 7.00 2.00 8.00 4.13 2.07 6.25 325VSS 200 1 25 7.00 2.00 8.00 3.56 1.88 3.86 332VSS 200 1¼ 32 7.00 2.00 8.00 4.13 2.07 6.25 *340VS 75 1½ 40 7.00 3.00 8.00 4.44 2.25 6.25 *350VS 75 2 50 7.00 3.00 8.00 5.38 2.75 6.25 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 20

F ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuators may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., F24-S US incorporates two built-in auxiliary switches: 2 x SPDT, 7 (2.5) @ 250 VC, UL listed, one switch is fixed at +5, one is adjustable 25 to 85. to live electrical components could result in death or serious injury. 1 Common 2 + Hot 3 F24 US 2 On/Off iring for 24 VC/DC 194 003-F-08 Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off iring for 120 VC 195-UX uxiliary Switches K20951-10/08 - Subject to change. elimo ircontrols (US), Inc.

F ctuators, Multi-Function Technology Dimensions with 2-ay Valve Models F24-MFT US F24-MFT-S US F24 w/built-in ux. Switches Technical Data Control MFT Control signal 2 to 10 VDC, (4 to 20 m with 500 Ω resistor) 0-135 Ω (MFT95) Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 6 holding 2.5 Transformer sizing 10 V, class 2 power Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft [1m], 18 G appliance cable Overload protection electronic throughout rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for on/off and floating point Feedback output 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of otation spring reversible with C/CC mounting motor reversible with built-in switch Position indication visual indicator Manual override hex crank unning time control 150 sec. independent of load spring <20 sec. mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C22.2 No. 24 certified, CE Noise level max. 45 d() F24-MFT-S US uxiliary switches * Dual Mounted ctuators 2 x SPDT, 7 (2.5) @ 250 VC, UL listed, one switch is fixed at +5, one is adjustable 25 to 85 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 224VS 400 1 25 7.00 2.00 8.00 3.37 6.25 225VS 50 1 25 7.00 2.00 8.00 3.62 6.25 2VS 200 1¼ 32 7.25 2.00 8.00 3.97 6.25 *9VS 400 1½ 40 7.50 2.00 8.00 4.37 6.25 *240VS 50 1½ 40 7.50 2.00 8.00 4.75 6.25 *249VS 200 2 50 8.00 2.00 8.00 4.68 6.25 9VSS 1000 ¾ 20 6.70 2.00 8.00 2.25 6.25 224VSS 1000 1 25 7.00 2.00 8.00 3.37 6.25 2VSS 1000 1¼ 32 7.25 2.00 8.00 3.97 6.25 *2VSS 1000 1¼ 32 7.25 2.00 8.00 3.97 6.25 *9VSS 1000 1½ 40 6.70 2.00 8.00 4.37 6.25 *249VSS 400 2 50 8.00 2.00 8.00 4.68 6.25 Dimensions with 3-ay Valve Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F 325VS 75 1 25 7.00 2.00 8.00 3.56 1.88 3.86 332VS 75 1¼ 32 7.00 2.00 8.00 4.13 2.07 6.25 *325VS 200 1 25 7.00 2.00 8.00 3.56 1.88 3.86 *332VS 200 1¼ 32 7.00 2.00 8.00 4.13 2.07 6.25 *340VS 75 1½ 40 7.00 2.00 8.00 4.44 2.25 6.25 *350VS 75 2 50 7.00 2.00 8.00 5.38 2.75 6.25 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 22

F ctuators, Multi-Function Technology iring Diagrams to live electrical components could result in death or serious injury. 24 VC/DC Transformer 043 2 CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position ( ) Feedback VDC (+) a (1) Common (2) Hot (3) y input (5) u output 3 ctuators may also be powered by 24 VDC. 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). On/Off control CC C MFT 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. (C only) 7 Position Feedback VDC ( ) (+) 6 (1) Common (2) + Hot (3) y input (5) u output 041 The ZG-01 500 Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PM, triac source and sink CC C MFT 302 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Floating Point control Propotional 2 to 10 or 4 to 20 m control signal 303 195-UXMFT uxiliary Switches

F ctuators, Multi-Function Technology 22 24 25 Override INSTLLTION NOTES Provide overload protection and disconnect as required. ctuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. Switch Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. 22 Low Limit Control 22 Series 90 Controller 135 Controller Series 90 low limit control 135 for 0 to 50% control 280 for 0 to 100% control lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) 015 016 High Limit Control 22 Series 90 Controller iring Multiple ctuators to a Series 90 Controller lk (1) Common ed (2) + Hot Series 90 high limit control - 280 Shunting esistor 24 Series 90 Controller No. of actuators esistance 2 140 3 71.5 4 47.5 5 37.5 6 28 esistor Kit No. ZG-03 To other actuators lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) ht (3) 25 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) iring Multiple ctuators to a Series 90 Controller using a Minimum Position Potentiometer Series 90 Controller 22 Shunting esistor 24 22 H205 Changeover Controller Occupied Contact To other actuators S963 Minimum Position Potentiometer lk (1) Common ed (2) + Hot 25 ht (3) ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) 017 018 019 Typical wiring diagrams for multiple actuators used with the 973, 7100 and T775 controllers 24 22 H205 Changeover Controller 22 Shunting esistor 973, 7100 Controller No. of actuators esistance 2 1300 3 910 4 768 esistor Kit No. ZG-06 22 24 Shunting esistor 22 Y 973, 7100 T775 Q209 Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) Occupied Contact Honeywell T675 Morning armup lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) Used with the 973 and 7100 controllers Honeywell T675 Morning armup Honeywell Q209 Minimum Position Potentiometer lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) lk (1) Common ed (2) + Hot 020 ht (3) 25 ht (4) ht (5) K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 24

LM()X24-3X1 ctuators, On/Off, Floating Point Dimensions with 2-ay Valve PGE7 H2 H1 C F K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Models LM24-3X1 LMX24-3X1 Technical Data Control On/Off, Floating Point Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 1.5 holding 0.2 Transformer sizing 3 V (class 2 power source) Electrical connection LM24-3X1 ½ conduit connector 3 ft, 18 G plenum rated cables Overload protection electronic throughout 0 to 95 rotation Input Impedance 600 Ω ngle of rotation 95 Torque 45 in-lb [5 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button unning time 95 seconds, constant independent of load Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS C22.2 No. 24 certified, CE acc. to 73//EEC Noise level <35 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F H1 H2 2VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 3VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 4VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 5VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size DN Valve ody COP Inches C D E F H1 H2 [mm] 315VS 75 ½ 15 6.50 1.50 4.70 2.30 1.25 3.19 9.75 8.50 H1 H2 E F PGE11 25

LM()X24-3X1 ctuators, On/Off, Floating Point iring Diagrams 266-08 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off control 267-08 Floating Point or On/Off control Piping The valve should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow sufficient room for valve with actuator and for service. llow 6 for cover removal and 12 for complete actuator removal. The assembly can be mounted with the actuator vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 26

LMX24-MFTX1 ctuators, Multi-Function Technology Dimensions with 2-ay Valve PGE7 H2 H1 C F K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Models LMX24-MFTX1 Technical Data Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 2 Transformer sizing 3.5 V (class 2 power source) Electrical connection 3 ft [1m] 10 ft [3m] 16 ft [5m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input Impedance 100k Ω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for On/Off and Floating Point Feedback 2 to 10 VDC, 0.5 m max VDC variable ngle of rotation 95 Torque 45 in-lb [5 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button unning time 150 seconds (default) Variable (35 to 150 secs) Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS E60730-1, CS C22.2 No. 24-93, CE acc. to 89/336/EEC Noise level <35 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 2VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 3VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 4VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 5VS 50 ½ 15 6.75 2.00 6.75 2.25 4.00 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D E F H1 H2 315VS 75 ½ 15 6.50 1.50 4.70 2.30 1.25 3.19 9.75 8.50 H1 H2 E F PGE11 27

LMX24-MFTX1 ctuators, Multi-Function Technology iring Diagrams 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. 4 5 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VC line. 6 ZG-01 may be used. 7 8 Contact closures & also can be triacs. & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. On/Off control 1 24 VC/DC Transformer 1 3 a Position ( ) Feedback VDC (+) 2 2 lk (1) Common red (2) Hot wht (3) y input org (5) u output MFT lk (1) Common red (2) Hot + 399 399 3 5 2 to 10 VDC Feedback Signal a 7 4 wht (3) y 1 input 8 Pnk (4) y 2 input org (5) u output 2 to 10V MFT Floating Point 1 3 Ω 500Ω 1/4 watt Control Signal 4 to 20 m or 2 to 10 VDC ( ) (+) 6 2 lk (1) Common red (2) + Hot wht (3) y 1 input, 2 to 10V org (5) u output, 2 to 10V 399 MFT VDC/4-20 m PM 1 (C only) 2 Position Feedback VDC ( ) (+) 5 lk (1) Common red (2) + Hot wht (3) y input org (5) u output MFT 399 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 28

NM()X24-3X1 ctuators, On/Off, Floating Point Dimensions with 2-ay Valve PGE7 H2 H1 C F K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Models NM24-3X1 NMX24-3X1 Technical Data Control On/Off, Floating Point Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 2.0 holding 0.2 Transformer sizing 4 V (class 2 power source) Electrical connection NM24-3X1 3 ft, 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input Impedance 600 Ω ngle of rotation max 95, adjustable with mechanical stop Torque 90 in-lb [10 Nm] Direction of rotation reversible with switch =CC with decreasing control signal (10-2V) =C with decreasing control signal (10-2V) Position indication reflective visual indicator (snap-on) Manual override external push button unning time 95 seconds, constant independent of load Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS C22.2 No. 24 certified, CE acc. to 73//EEC Noise level <45 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 9VS 400 ¾ 20 6.70 2.00 8.00 3.00 6.25 9.75 8.50 220VS 400 ¾ 20 6.70 2.00 8.00 3.12 6.25 9.75 8.50 5VSS 1000 ½ 15 6.70 2.00 8.00 2.25 6.25 9.75 8.50 9VSS 1000 ¾ 20 6.70 2.00 8.00 3.00 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 320VS 75 ¾ 20 6.70 1.50 6.88 2.82 1.62 3.15 9.75 8.50 325VS 75 1 25 7.00 1.50 6.88 3.56 1.88 3.15 9.75 8.50 H1 H2 E F PGE11 29

NM()X24-3X1 ctuators, On/Off, Floating Point iring Diagrams 266-08 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off control 267-08 Floating Point or On/Off control Piping The valve should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow sufficient room for valve with actuator and for service. llow 6 for cover removal and 12 for complete actuator removal. The assembly can be mounted with the actuator vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 30

NMX24-MFTX1 ctuators, Multi-Function Technology Dimensions with 2-ay Valve PGE7 H2 H1 C F Models NMX24-MFTX1 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Technical Data Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 3.5 (1.25 ) Transformer sizing 5.5 V (class 2 power source) Electrical connection 3 ft [1m] 10 ft [3m] 16 ft [5m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input Impedance 100k Ω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for On/Off and Floating Point Feedback 2 to 10 VDC, 0.5 m max VDC variable ngle of rotation max 95, adjust. with mechanical stop electronically variable Torque 90 in-lb [10 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button unning time 150 seconds (default) Variable (45 to 170 secs) Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS E60730-1, CS C22.2 No. 24-93, CE acc. to 89/336/EEC Noise level <45 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 9VS 400 ¾ 20 6.70 2.00 8.00 3.00 6.25 9.75 8.50 220VS 400 ¾ 20 6.70 2.00 8.00 3.12 6.25 9.75 8.50 5VSS 1000 ½ 15 6.70 2.00 8.00 2.25 6.25 9.75 8.50 9VSS 1000 ¾ 20 6.70 2.00 8.00 3.00 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 320VS 75 ¾ 20 6.70 1.50 6.88 2.82 1.62 3.15 9.75 8.50 325VS 75 1 25 7.00 1.50 6.88 3.56 1.88 3.15 9.75 8.50 H1 H2 E F PGE11 31

NMX24-MFTX1 ctuators, Multi-Function Technology iring Diagrams 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. 4 5 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VC line. 6 ZG-01 may be used. 7 8 Contact closures & also can be triacs. & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. On/Off control 1 24 VC/DC Transformer 1 3 a Position ( ) Feedback VDC (+) 2 2 lk (1) Common red (2) Hot wht (3) y input org (5) u output MFT lk (1) Common red (2) Hot + 399 399 3 5 2 to 10 VDC Feedback Signal a 7 4 wht (3) y 1 input 8 Pnk (4) y 2 input org (5) u output 2 to 10V MFT Floating Point 1 3 Ω 500Ω 1/4 watt Control Signal 4 to 20 m or 2 to 10 VDC ( ) (+) 6 2 lk (1) Common red (2) + Hot wht (3) y 1 input, 2 to 10V org (5) u output, 2 to 10V 399 MFT VDC/4-20 m PM 1 (C only) 2 Position Feedback VDC ( ) (+) 5 lk (1) Common red (2) + Hot wht (3) y input org (5) u output MFT 399 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 32

M()X24-3X1 ctuators, On/Off, Floating Point Dimensions with 2-ay Valve PGE7 H2 H1 C F K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Models M24-3X1 MX24-3X1 Technical Data Control On/Off, Floating Point Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 2.5 holding 0.2 Transformer sizing 5.5 V (class 2 power source) Electrical connection M24-3X1 ½ conduit connector 3 ft, 18 G plenum rated cable Overload protection electronic throughout 0 to 95 rotation Input Impedance 600 Ω ngle of rotation max 95, adjustable with mechanical stop Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button unning time 95 seconds, constant independent of load Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS C22.2 No. 24 certified, CE acc. to 73//EEC Noise level <45 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 224VS 400 1 25 7.00 2.00 8.00 3.37 6.25 9.75 8.50 225VS 200 1 25 7.00 2.00 8.00 3.62 6.25 9.75 8.50 2VS 400 1¼ 32 7.25 2.00 8.00 3.97 6.25 9.75 8.50 224VSS 1000 1 25 7.00 2.00 8.00 3.37 6.25 9.75 8.50 2VSS 1000 1¼ 32 7.25 2.00 8.00 3.97 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 320VS 75 ¾ 20 6.70 1.50 6.88 2.82 1.62 3.15 9.75 8.50 325VS 75 1 25 7.00 1.50 6.88 3.56 1.88 3.15 9.75 8.50 332VS 75 1¼ 32 7.00 2.00 7.48 4.13 2.07 3.46 9.75 8.50 H1 H2 E F PGE11 33

M()X24-3X1 ctuators, On/Off, Floating Point iring Diagrams 259-08 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 24 VDC. 5 Only connect common to neg. ( ) leg of control circuits. On/Off control Meets culus or UL and CS requirements without the need of an electrical ground connection. 260-08 NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Floating Point or On/Off control Piping The valve should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow sufficient room for valve with actuator and for service. llow 6 for cover removal and 12 for complete actuator removal. The assembly can be mounted with the actuator vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 34

MX24-MFTX1 ctuators, Multi-Function Technology Dimensions with 2-ay Valve PGE7 H2 H1 C F K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. Models MX24-MFT MX24-MFT95 Technical Data Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 4 (1.25 ) Transformer sizing 6 V (class 2 power source) Electrical connection 3 ft [1m] 10 ft [3m] 16 ft [5m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input Impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for On/Off and Floating Point Feedback 2 to 10 VDC, 0.5 m max VDC variable ngle of rotation max 95, adjust. with mechanical stop electronically variable Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button unning time 150 seconds (default) Variable (90 to 350 secs) Humidity 5 to 95% H non-condensing (EN 60730-1) mbient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL 60730-1/-2-14, CN/CS E60730-1, CS C22.2 No. 24-93, CE acc. to 89/336/EEC Noise level <45 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 224VS 400 1 25 7.00 2.00 8.00 3.37 6.25 9.75 8.50 225VS 200 1 25 7.00 2.00 8.00 3.62 6.25 9.75 8.50 2VS 400 1¼ 32 7.25 2.00 8.00 3.97 6.25 9.75 8.50 224VSS 1000 1 25 7.00 2.00 8.00 3.37 6.25 9.75 8.50 2VSS 1000 1¼ 32 7.25 2.00 8.00 3.97 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 320VS 75 ¾ 20 6.70 1.50 6.88 2.82 1.62 3.15 9.75 8.50 325VS 75 1 25 7.00 1.50 6.88 3.56 1.88 3.15 9.75 8.50 332VS 75 1¼ 32 7.00 2.00 7.48 4.13 2.07 3.46 9.75 8.50 H1 H2 E F PGE11 35

MX24-MFTX1 ctuators, Multi-Function Technology iring Diagrams 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. 4 5 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VC line. 6 ZG-01 may be used. 7 8 Contact closures & also can be triacs. & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. On/Off control 1 24 VC/DC Transformer 1 3 a Position ( ) Feedback VDC (+) 2 2 lk (1) Common red (2) Hot wht (3) y input org (5) u output MFT lk (1) Common red (2) Hot + 399 399 3 5 2 to 10 VDC Feedback Signal a 7 4 wht (3) y 1 input 8 Pnk (4) y 2 input org (5) u output 2 to 10V MFT Floating Point 1 3 Ω 500Ω 1/4 watt Control Signal 4 to 20 m or 2 to 10 VDC ( ) (+) 6 2 lk (1) Common red (2) + Hot wht (3) y 1 input, 2 to 10V org (5) u output, 2 to 10V 399 MFT VDC/4-20 m PM 1 (C only) 2 Position Feedback VDC ( ) (+) 5 lk (1) Common red (2) + Hot wht (3) y input org (5) u output MFT 399 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 36

MX24-MFTX1 ctuators, Multi-Function Technology K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 22 24 25 Override INSTLLTION NOTES Provide overload protection and disconnect as required. ctuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. Switch Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. 22 Low Limit Control 22 Series 90 Controller 135 Controller Series 90 low limit control 135 for 0 to 50% control 280 for 0 to 100% control lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) 015 016 High Limit Control 22 Series 90 Controller iring Multiple ctuators to a Series 90 Controller lk (1) Common ed (2) + Hot Series 90 high limit control - 280 Shunting esistor 24 Series 90 Controller No. of actuators esistance 2 140 3 71.5 4 47.5 5 37.5 6 28 esistor Kit No. ZG-03 To other actuators lk (1) Common ed (2) + Hot ht (3) 24 ht (4) ht (5) ht (3) 25 ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) iring Multiple ctuators to a Series 90 Controller using a Minimum Position Potentiometer Series 90 Controller 22 Shunting esistor 24 22 H205 Changeover Controller Occupied Contact To other actuators S963 Minimum Position Potentiometer lk (1) Common ed (2) + Hot 25 ht (3) ht (4) ht (5) lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) 017 018 019 Typical wiring diagrams for multiple actuators used with the 973, 7100 and T775 controllers 24 22 H205 Changeover Controller 22 Shunting esistor 973, 7100 Controller No. of actuators esistance 2 1300 3 910 4 768 esistor Kit No. ZG-06 22 24 Shunting esistor 22 Y 973, 7100 T775 Q209 Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) Occupied Contact Honeywell T675 Morning armup lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) Used with the 973 and 7100 controllers Honeywell T675 Morning armup Honeywell Q209 Minimum Position Potentiometer lk (1) Common ed (2) + Hot ht (3) 25 ht (4) ht (5) lk (1) Common ed (2) + Hot 020 ht (3) 25 ht (4) ht (5) 37

GM24-3X1 ctuators, On/Off, Floating Point Dimensions with 2-ay Valve PGE7 H2 H1 C F Models GM24-3X1 2xGM24-3X1 Technical Data Control On/Off, Floating Point Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 4 holding 2 Transformer sizing 6 V (Class 2 power source) Electrical connection 3 ft [1m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout stroke ngle of rotation 95 Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) unning time 150 seconds, constant independent of load Humidity 5 to 95% H non-condensing mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2/IP54 with cable entry down Housing material UL94-5V (flammability rating) gency listings culus acc. to UL 60730-1/-2-14, CN/CS E60730-1, CS C22.2 No. 24-93, CE acc. to 89/336/EEC Noise level <45 d() Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 9VS 400 1½ 40 7.50 3.00 8.00 4.37 6.25 9.75 8.50 249VS 200 2 50 7.50 3.00 8.00 4.68 6.25 9.75 8.50 9VSS 1000 1½ 40 7.50 3.00 8.00 4.37 6.25 9.75 8.50 249VSS 400 2 50 7.50 3.00 8.00 4.68 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 340VS 75 1½ 40 7.00 2.00 8.00 4.44 2.25 6.25 9.75 8.50 350VS 75 2 50 15.00 8.00 8.00 5.38 2.75 6.25 9.25 8.50 H1 H2 E F PGE11 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 38

GM24-3X1 ctuators, On/Off, Floating Point Dimensions with 2xGM... and 2-ay Valve iring Diagrams H2 PGE7 1 Provide overload protection and disconnect as required. 2 ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 24 VDC. H1 C F 4 5 7 8 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VC line. Contact closures & also can be triacs. & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1* H2* 240VS 400 1½ 40 7.50 3.00 8.00 4.75 6.25 9.75 8.50 250VS 200 2 50 15.00 3.00 8.00 5.37 6.25 9.75 8.50 265VS 100 2½ 65 15.00 3.00 8.00 6.25 6.25 9.75 8.50 280VS 50 3 80 15.00 3.00 8.00 6.75 6.25 9.75 8.50 249VSS 1000 2 50 7.50 3.00 8.00 4.68 6.25 9.75 8.50 265VSS 200 2½ 65 15.00 3.00 8.00 6.25 6.25 9.75 8.50 *Handles not available on spring return series or dual mounted actuators Dimensions with 2xGM... and 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1* H2* 350VS 200 2 50 15.00 8.00 8.00 5.38 2.75 6.25 9.75 8.50 *Handles not available on spring return series or dual mounted actuators H1 H2 E F PGE11 On/Off control 1 Floating Point Piping 3 24 VC/DC Transformer 1 3 a Position ( ) Feedback VDC (+) 5 2 to 10 VDC Feedback Signal a 7 4 2 2 lk (1) Common red (2) Hot wht (3) y input org (5) u output MFT lk (1) Common red (2) Hot + wht (3) y 1 input Pnk (4) y 2 input org (5) u output 2 to 10V MFT The valve should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow sufficient room for valve with actuator and for service. llow 6 for cover removal and 12 for complete actuator removal. The assembly can be mounted with the actuator vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. 8 399 399 39

GMX24-MFTX1 ctuators, Multi-Function Technology Dimensions with 2-ay Valve PGE7 H2 H1 C F Models GMX24-MFTX1 *2xGMX24-MFTX1 GMX24-MFT95 Technical Data Control On/Off, Floating Point, 2 to 10 VDC Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 4.5 holding 3 Transformer sizing 7 V (Class 2 power source) Electrical connection 3 ft [1m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout stroke Input impedance 100k Ω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for On/Off and Floating Point Feedback 2 to 10 VDC, 0.5 m max VDC variable ngle of rotation 95 Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) unning time 150 seconds, constant independent of load Humidity 5 to 95% H non-condensing mbient temperature -22 F to 122 F [-30 C to 50 C] Housing NEM 2/IP54 with cable entry down Housing material UL94-5V (flammability rating) gency listings culus acc. to UL 60730-1/-2-14, CN/CS E60730-1, CS C22.2 No. 24-93, CE acc. to 89/336/EEC Noise level <45 d() Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 9VS 400 1½ 40 7.50 3.00 8.00 4.37 6.25 9.75 8.50 249VS 200 2 50 7.50 3.00 8.00 4.68 6.25 9.75 8.50 9VSS 1000 1½ 40 7.50 3.00 8.00 4.37 6.25 9.75 8.50 249VSS 400 2 50 7.50 3.00 8.00 4.68 6.25 9.75 8.50 Dimensions with 3-ay Valve C D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D E F H1 H2 340VS 75 1½ 40 7.00 2.00 8.00 4.44 2.25 6.25 9.75 8.50 350VS 75 2 50 15.00 8.00 8.00 5.38 2.75 6.25 9.25 8.50 H1 H2 E F PGE11 K20951-10/08 - Subject to change. elimo ircontrols (US), Inc. 40