CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Similar documents
AXIAL FANS Catalogue CN0050C01 May 2008

Short casing. Long casing (L version) Commercial premises

Unobox units with backward curved centrifugal impellers

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Size and Configurations

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS

AND AXIAL FLOW FANS ECOFIT

Axial fans. What s more, non-stock models are normally available within two weeks.

MAJAX-2 GENERAL SPECIFICATION

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

JM Aerofoil Multi-Stage 50 Hz

REVOLUTION SLCX Product Brochure

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Max. airflow m 3 /s Diam. min. Diam. max

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Sabre Plate Mounted Sickle Fans (VSP)

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

DUCT-M HT F400/2h. Smoke exhaust ducted axial fan APPLICATIONS TECHNICAL SPECIFICATIONS VERSIONS ACCESSORIES ON REQUEST. May 2018 Catalog N 000 Rev.

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

NEW GENERATION SERIES

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

TGT Series Adjustable Pitch Fans

NOVENCO FAN CATALOGUE

BIFLOW SB CON Product Brochure

Sabre Sickle Fan Assisted Roof Cowls (VSR)

BIFURCATED AXIAL FANS

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

TGT Series Adjustable Pitch Fans

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

JM Aerofoil Bifurcated Fans

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Novenco axial flow fans. ZerAx - Standard January 2010

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Section 4. Axial Fans - Section 4

CGT Series Adjustable Pitch Fans

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

FAN & BLOWER CENTRIFUGAL FANS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Bifurcated Case Axial Fans (BIFA)

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CGT Series Adjustable Pitch Fans

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

CENTRIFUGAL IN-LINE FANS VENT Series

JM Aerofoil Bifurcated 50Hz

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

Hison Axial Flow Fans

ExpressBuild STANDARD FAN RANGE

Hison Axial Flow Fans

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

NEW WINDER. Impellers with higher efficiency and less sound level

Vent-Axia Sabre Sickle Roof Fans (VSR)

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BACKWARD CURVED HIGH PRESSURE FANS

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

DIrect drive exhaust & supply panel fans

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Cross-flow Fans. TFD/FFD Series

Airscrew 105 to 170 Vmax Vaneaxial Fans

Airscrew 200+ Vmax Vaneaxial Fans

TURNING AIR INTO SOLUTIONS. HIGH EFFICIENCY INDUSTRIAL BACKWARD CURVED FANS MODEL HIB

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

HIGH-POWERED VENTILATORS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

Cross-Flow Fans. TF/FF Series

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

COMPACT Series type HCFB / HCFT (Plastic impellers)

Filtered Kitchen Supply Packaged Ventilator

Powerful centrifugal fans for universal use: The product ranges TEM and REM

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

ACOUSTIC CABINET FANS CVAB / CVAT Series

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Mixed Flow Roof Fans (RMH)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

KV sileo 100 M. Circular duct fans. Circular duct fans

Medium Pressure Centrifugal Fans


Transcription:

CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound Performance 10 2

ADJUSTABLE PITCH AXIAL FLOW FANS FEATURES The AP Series of duct mounted adjustable pitch axial flow fans is available in the following variants : AP series : direct drive APV series : direct-drive vertical mounted Construction The casings are of mild steel and are hot-dip galvanised after manufacture. Impeller blades shall have an aerofoil section and be pressure die-cast aluminium, injection-moulded glass-reinforced plastic or nylon. Anti-static blades for hazardous applications up to 1400mm diameter, are also available. Motors Type-squirrel cage induction motor which can be selected to suit virtually any specification. Electricity supply single or three-phase to suit a wide range of voltages and frequencies. Bearings ball. Motors to meet Australian Ex e, Ex d, Ex n or D.I.P Standards can be fitted. Internal Thermal Protection Can be provided as an optional extra. Testing Air flow testing to AMCA Standard 210-07 Sound testing to AMCA Standard 300-08 Fan ranges described by this catalogue have been tested in the AMCA International Accredited Laboratory, in accordance with AMCA Standard 210-07 (figure 12, Installation Type D, Standard air density of 1.2Kg/m 3 ). 3

DIMENSIONS J Figure 1 General Dimensions Note Dimensions apply to Axial Fan code AP, APV Weights are approximate and may vary with motor brand Fan Code ØA ID ØB OD C ØD ØE PCD F G H J K L Wgt. kg..056 560 645 12 12 620 15 400 355 510 330 345 57..063 630 715 12 12 690 15 450 400 580 375 395 75..071 710 795 16 12 770 11.25 450 450 660 425 395 94 4

PERFORMANCE CURVES AXIAL FAN AP0564HA6/10/15/20/25/30/35/40 Diameter : 560mm Hz: 50 Outlet area: 0.2463m 2 Rated Power : 1.5kW Speed: 1440 rpm FEG Grade: FEG63 250 200 0564/6 251 Hub Static Pressure - Pa 150 100 50 Absorbed Power - kw 0 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Blade angle 10 15 20 25 30 35 40 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 10 15 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 20 25 30 35 40 Performance certified is for Installation Type D: Ducted Inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances (accessories). 5

Fan Model : AP0564HA6/10 SOUND PERFORMANCE 83 76 73 76 74 74 73 64 0 1.69 1497 83 75 73 76 75 75 73 65 40 1.5 1490 83 77 78 83 84 81 74 66 100 1.22 1489 87 90 90 85 81 77 72 64 148 0.85 1487 3 / Fan Model : AP0564HA6/25 86 84 79 78 77 77 75 68 0 2.98 1477 88 84 78 78 76 76 74 67 89 2.55 1472 88 85 81 79 77 76 74 67 129 2.34 1472 88 85 83 83 79 79 75 69 171 2.03 1471 3 / Fan Model : AP0564HA6/40 93 89 83 85 81 79 76 71 0 3.87 1446 94 89 82 85 80 79 76 71 48 3.58 1445 95 89 82 84 81 80 76 72 116 3.18 1445 97 89 82 84 83 81 77 72 187 2.52 1449 3 / The Sound Power Level ratings shown are in decibels referred to 10-12 watts calculated per AMCA International Standard 301. Values shown are for inlet Lwi sound power levels for Installation type D: Ducted Inlet, Ducted Outlet. Ratings include the effect of duct end correction. 6

PERFORMANCE CURVES AXIAL FAN AP0634HA6/10/15/20/25/30/35/40 Diameter : 630mm Hz : 50 Outlet area: 0.3117m 2 Rated Power : 2.2kW Speed: 1440 rpm FEG Grade: FEG67 250 200 0634/6 251 Hub Static Pressure - Pa 150 100 50 Absorbed Power - kw 0 2.20 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 Blade angle 10 15 20 25 30 35 40 0 1 2 3 4 5 6 40 35 30 25 20 15 10 0 1 2 3 4 5 6 Performance certified is for Installation Type D: Ducted Inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances (accessories). 7

Fan Model : AP0634HA6/10 SOUND PERFORMANCE 81 75 76 78 78 76 78 69 17 2.3 1491 81 75 75 78 78 78 78 70 35 2.13 1492 83 79 83 89 88 84 78 70 102 1.67 1491 87 95 90 88 84 80 75 67 164 1.13 1492 3 / Fan Model : AP0634HA6/25 85 83 80 81 81 79 78 72 0 4.16 1483 87 84 80 81 80 78 77 72 105 3.51 1479 87 85 81 82 81 80 78 72 155 3.16 1477 89 86 86 88 86 83 79 74 196 2.6 1475 3 / Fan Model : AP0634HA6/40 93 89 84 85 83 81 79 75 0 5.49 1452 92 89 83 85 83 82 79 76 80 4.95 1450 93 91 83 84 84 84 80 76 132 4.58 1451 95 90 84 85 86 85 80 76 213 3.86 1457 3 / The Sound Power Level ratings shown are in decibels referred to 10-12 watts calculated per AMCA International Standard 301. Values shown are for Inlet Lwi sound power levels for Installation type D: Ducted Inlet, Ducted Outlet. Ratings include the effect of duct end correction. 8

PERFORMANCE CURVES AXIAL FAN AP0714HA6/10/15/20/25/30/35/40 Diameter : 710mm Hz: 50 Outlet area: 0.3959m 2 Rated Power : 4.0 kw Speed: 1440 rpm FEG Grade: FEG67 300 250 0714/6 251 Hub Static presuure - Pa 200 150 100 50 Absorved power -kw 0 3.6 3.2 2.8 2.4 2.0 1.6 1.2 0.8 0.4 0.0 Blade angle 10 15 20 25 30 35 40 0 10 15 0 20 25 30 35 40 Performance certified is for Installation Type D: Ducted Inlet, Ducted Outlet. Performance ratings do not include the effects of appurtenances (accessories). 9

Fan Model : AP0714HA6/10 SOUND PERFORMANCE 82 81 80 82 82 79 82 74 0 3.1 1500 83 81 80 84 88 86 83 75 72 2.55 1496 85 84 91 92 90 85 80 73 146 1.93 1497 86 89 85 84 82 81 78 71 221 1.1 1497 3 / Fan Model : AP0714HA6/25 88 88 84 86 84 82 81 76 0 5.77 1487 87 88 83 85 83 82 80 76 115 4.89 1484 89 89 87 89 87 85 82 77 178 4.32 1485 91 90 96 96 91 88 83 78 232 3.46 1484 3 / Fan Model : AP0714HA6/40 95 93 88 90 88 85 83 80 0 7.58 1467 94 92 87 89 88 86 84 80 84 6.86 1464 94 93 86 88 89 88 85 80 157 6.2 1468 97 94 89 90 89 88 84 80 228 5.32 1464 3 / The Sound Power Level ratings shown are in decibels referred to 10-12 watts calculated per AMCA International Standard 301. Values shown are for Inlet Lwi sound power levels for Installation type D: Ducted Inlet, Ducted Outlet. Ratings include the effect of duct end correction. 10