MM-AVR UPS Series User s Manual

Similar documents
XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

CP900EPFCLCD User s Manual K

BATTERY PACK. User's Manual

PR1000ELCD / PR1500ELCD User s Manual

Xtreme Value Tower Series (XVT) User s & Installation Manual. Xtreme Power Conversion (XPC) Corporation

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

BRAVER UPS. (Uninterruptible Power System) User s Manual

User s Manual Legend SB825 UPS K

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

User s Manual Lineage LI3000 UPS K

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User s Manual for: UP625 UPS UP825 UPS. ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

CTFRP Series Power Supplies

User's Manual. Rack/Tower Extended Runtime Battery Packs

Uninterruptible Power Supply

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Installation and Operation Back-UPS BX550CI-CN

BroadBand PowerShield. 20 AHr Battery. User Manual

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Installation and Operation Manual Back-UPS BX1100CI-CN

V80 Value Series Pure Sine Wave Line Interactive UPS

USER MANUAL. Uninterruptible power supply MODEL: 53965,

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Back-UPS CS Back-UPS CS 350

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Limousin II User Manual

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BR1000-CH

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Uninterruptible Power System

Broadband PowerShield. CP27U Models. User Manual

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

POWERWARE User s Guide VA.

ALLIANCE SERIES OWNER'S MANUAL

3000VA 120/208/230VAC

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Liebert PSA VA. Installer/User Guide

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Installation Power Management Unit Battery Cables and Battery Harness

Installation and Operation

BATTERY REPLACEMENT GUIDE

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

02/15/01. Powerware User s Guide VA.

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Informer Compact Series

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Uninterruptible Power System

Power Distribution Units

Powerware Vdc Extended Battery Cabinet User s Guide.

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

WARNINGS, CAUTIONS AND NOTES

Retrofit Kit 1 OM.qxd 12/7/ :06 AM Page 1. Owner s Manual. Medical-Grade Mobile Power Retrofit Kit Model #: HCRK-1

400 Watt Backup Power System Owner s Manual

UTILITY INPUT MAINS OUTLET

Uninterruptible Power System

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

USER MANUAL English / Español

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

Power. On Your Terms.

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

10 Year Limited Warranty

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

General Precautions. Personnel Precautions

DC to AC Power Inverters

DC to AC Power Inverters

BRAVO Inverter/Battery Charger. Table of Contents

ADI-125/750 ADI-125/1500 ADI-125/2500

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

JUMP STARTER OPERATOR S MANUAL RA1900

Item no Smart AC 200 USB. User s Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

Operating Instructions for PAC800 Battery Charger

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

OWNERS MANUAL JANUARY 2007 ISO

Adjustable Base. CONTENTS Advisory Setup and Installation Innova Wired Hand Control year Warranty 1-10

Users Guide for Ac-sync

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

APC Smart-UPS RT UXI/UXICH

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

BPRTXL Series Battery Packs. User's Manual

900 PEAK AMP PORTABLE JUMP STARTER

INSTALLATION & OWNER'S MANUAL

Transcription:

MM-AVR UPS Series User s Manual

TABLE OF CONTENTS Safety Instructions... 2 Description... 2 Determining Power Requirements... 3 Hardware Installation Guide... 3 Battery Replacement Instructions... 4 LED Indicators... 6 Troubleshooting Guide... 6 Specifications... 7 Obtaining Service... 9 Limited Product Warranty... 10 Thank you for purchasing a MINUTEMAN UPS Product. To enjoy all the features and benefits of this Uninterruptible Power Supply (UPS), please read and follow all installation and operation instructions completely. This UPS is designed to provide power protection for connected electronic equipment. Please read this manual before installing your MM-AVR Series UPS, models MM- AVR600, MM-AVR800, MM-AVR1200 as it provides important information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and performance. Included is information on customer support and factory service if it is required. If you experience a problem with the UPS please refer to the Troubleshooting guide in this manual to correct the problem or collect enough information so that the Technical Support Department can rapidly assist you. CAUTION: Any changes or modifications not expressly approved by the guarantee of this device could void the user s authority to operate the equipment. 1

MM-AVR600, MM-AVR800, MM-AVR1200 User s Manual Uninterruptible Power Supply (UPS) IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of UPS. Read this manual thoroughly before attempting to unpack, install, or operate. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range). CAUTION! To reduce the risk of electric shock, do not remove the cover. Qualified Service Personnel must perform repairs and maintenance. No user serviceable parts inside. CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. CAUTION! UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an AC wall outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS. CAUTION! To avoid electrical shock, turn off the UPS and unplug it from the AC power source before servicing the battery or installing a computer component. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! MINUTEMAN UPS does not sell products for life support or medical applications. DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical applications or patient care. DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the UPS to short out. DESCRIPTION Battery/Surge Outlets Provides battery-powered/surge outlets for the connected equipment and insures uninterrupted operation of your equipment during a power failure. Power Switch Can be used as a master on/off switch for equipment connected to the battery-powered outlets. Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing power, free of surges and spikes. Fuse The fuse provides overload and fault protection. RJ 11 Phone Jacks Protects any standard modem, fax or single line telephone. 2

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor and peripheral equipment does not exceed the maximum VA rating for the MM-AVR600, MM-AVR800 and MM-AVR1200. The maximum VA values would be 600VA, 800VA and 1200VA, respectively. 2. Ensure that the equipment plugged into the battery-powered outlets does not exceed the UPS s rated capacity. If UPS s rated capacities are exceeded, an overload condition may occur and cause the UPS to shut down and trip the circuit breaker. 3. If the power requirements of your equipment are listed in values other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by doing the calculations below. Note: The equation below only calculates the maximum amount of VA that the equipment can use, not what is typically used by the equipment at any given time. Users should expect usage requirements to be approximately 60% of below value to estimate power requirements: Watts (W) x 1.82 = VA or Amps (A) x 120 = VA Add the totals for all of the equipment and multiply this total by 0.65 to calculate actual requirements. Note: Many factors can affect the amount of power that your computer system will require. The total load that you will be placing on the battery-powered outlets should not exceed 90% of the UPS s capacity. Hardware Installation Guide 1. Your new UPS may be used immediately upon receipt. However, charging the battery for at least 4-hours is recommended to ensure that the battery s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, plug the power cord into the AC wall outlet and turn the power switch on. Note: MM-AVR units will charge the battery with the power switch on or off. 2. With the UPS off and unplugged, connect your computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive, etc ) into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum or other large electrical device into the UPS. The power demands of these devices will overload and possibly damage the UPS. 3. To protect a fax, single line phone or modem, connect a telephone cable from the wall jack outlet to the IN jack of the UPS. Connect a telephone cable from the OUT jack to the modem port on your computer. The OUT jack can be used to protect a single line telephone or fax machine. 4. Plug the UPS into a 2 pole, 3 wire grounding receptacle (AC wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc ). Note: DO NOT use extension cords, power or surge strips on the input or the output of the UPS. 5. Depress the power switch to turn the UPS on. The power on LED indicator will illuminate and the UPS will beep once. 6. If an overload is detected, an audible alarm will sound and the UPS will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the batterypowered outlets. Wait 10-seconds. Make sure the circuit breaker is depressed and then turn the UPS on. 7. Your UPS is equipped with an auto-charge feature (all units). When the UPS is plugged into an AC wall outlet and there is an acceptable AC voltage present, the battery will automatically recharge. 8. To maintain optimal battery charge, leave the UPS plugged into an AC wall outlet with the power switch turned on at all times. 9. To store your UPS for an extended period, cover and store it with the battery fully charged. Recharge the battery every three months to ensure battery life. 3

MM-AVR600, MM-AVR800, MM-AVR1200 User s Manual Uninterruptible Power Supply (UPS) REPLACING THE BATTERY (QUALIFIED SERVICE PERSONNEL ONLY) CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of Qualified Service Personnel knowledgeable of batteries and their precautions. CAUTION! Use only the specified type of battery. See your dealer for replacement batteries. CAUTION! The battery may present risk of electrical shock. Do not dispose of battery in a fire, as it may explode. Follow all local ordinances regarding proper disposal of batteries. CAUTION! Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic. CAUTION! Although the battery system voltage is only 12VDC and 24VDC, the battery can present a high risk of short circuit current and electrical shock. The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal. Observe these precautions when replacing the battery: 1. Remove all watches, rings or other metal objects. 2. Only use tools with insulated handles. 3. Do not lay tools or metal parts on top of battery or any terminals. 4. Wear protective eye gear (goggles), rubber gloves and boots. 5. Disconnect the charging source before connecting or disconnecting the battery terminals. 6. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove the source of ground. Contact with a grounded battery can result in electrical shock! The likelihood of such shock will be reduced if; such grounds are removed during installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit). BATTERY REPLACEMENT PROCEDURE (QUALIFIED SERVICE PERSONNEL ONLY) Note: The MM-AVR600 and the MM-AVR800 have user replaceable batteries. The MM-AVR1200 does not allow for user replacement of the batteries. 1. Turn off and unplug all connected equipment. 2. Turn the UPS off and unplug the UPS s power cord from the AC wall outlet. 3. Turn the UPS upside down. 4. Remove the retaining screws from the battery compartment door. 5. Remove the battery compartment door. Retaining Screws 4

6. Remove the defective battery from the battery compartment. 7. Disconnect the battery positive (red) wire from the battery positive (+) terminal. 8. Turn the power switch on, to discharge the UPS. 9. Disconnect the battery negative (black) wire from the battery negative (-) terminal. 10. Set the defective battery aside. 11. Connect the battery negative (black) wire to the battery negative (-) terminal on the new battery. 12. Connect the battery positive (red) wire to the battery positive (+) terminal on the new battery. Note: Some sparking may occur, this is normal. 13. Install the new battery into the battery compartment. DO NOT pinch the battery wires in between the battery and the case. 14. Reinstall the battery compartment door and the retaining screws. 15. Properly dispose of the old batteries at an appropriate recycling facility or return them to the supplier in the packing material for the new batteries. 16. The UPS is now ready for normal operation. Note: Batteries are consider HAZARDOUS WASTE and must be disposed of properly at an appropriate recycling facility or return them to the supplier. Contact your local government for more information about proper disposal and recycling of batteries. Note: Replace the batteries with the same number and type as originally installed in the UPS. These batteries have pressure-operated vents. These UPS contain sealed non-spillable lead-acid batteries. Model # MM-AVR600 MM-AVR800 MM-AVR1200 Battery QTY/Rating 1 x 12V 7AH 1 x 12V 9AH 2 x 12V 7AH 5

MM-AVR600, MM-AVR800, MM-AVR1200 User s Manual Uninterruptible Power Supply (UPS) DEFINITIONS FOR LED INDICATORS Indicator Sound/Alarm Situation LED 1 (Green) Illuminated LED 2 (Yellow) Illuminated LED 3 (Red) Illuminated LED 3 (Red) Illuminated LED 3 (Red) Illuminated No LED's Illuminated No sound No sound Beeps every two seconds Beeps every one second Continuous beeping No sound Mains normal, Input power source is supplying the load Mains normal, Battery is charging Mains abnormal, Battery is supplying the load Mains abnormal, Battery is low Battery exhausted, UPS will protect itself and switch off UPS shutdown, In sleep mode TROUBLESHOOTING Problem Possible Cause Solution Full-time surge protection outlets stop providing power to equipment. The UPS does not perform expected runtime. The UPS will not turn on. The UPS shuts down when there is a loss of AC power. Fuse has tripped due to an overload. Turn the UPS off and unplug at least one piece of equipment. Wait 10- seconds, replace the fuse with a fuse of like size and rating, and then turn the UPS on. Battery not fully charged. Recharge the battery for at least 4- hours. The Battery is defective. The on/off switch is designed to prevent damage by rapidly turning it off and on. The UPS is not plugged into an AC wall outlet. The battery is defective. Mechanical problem. The UPS is not providing battery power. Contact MINUTEMAN UPS about replacement batteries at mmsupport@minutemanups.com Turn the UPS off. Wait 10-seconds and then turn the UPS on. Connect the UPS to an 110/120V 60Hz AC wall outlet. Contact MINUTEMAN UPS about replacement batteries at mmsupport@minutemanups.com Contact MINUTEMAN UPS at mmsupport@minutemanups.com Shutdown your computer and turn the UPS off. Wait 10-seconds and turn the UPS back on. This should reset the UPS. 6

SPECIFICATIONS Model MM-AVR 600 MM-AVR 800 MM-AVR 1200 Capacity 600VA/300W 800VA/480W 1200VA/600W Phase Single phase Voltage Range 95V-145V ±3V Input Frequency 60HZ ±5HZ Voltage (battery mode) 120V ±10% Waveform AC mode - follow utility Battery mode - Step Sine Wave Frequency Frequency AC mode - follow utility, Battery mode - 60Hz ±5Hz <0.5HZ (battery operation) Output Transfer Time Typical 4ms, max 10ms Surge Protection 320 Joules Input Protection Compliance with IEEE 587 Protection Short Circuit Fuse Type Recharge Backup Time (full load) 12V Sealed non-spillable lead acid, maintenance free After full discharge, 8 hours to 90% capacity 3 min Battery Charge Current 350mA~1A Battery Configuration 1x12V/7AH 1x12V/9AH 2x12V/7AH Green and Orange LED on, Red LED off, AC Mode No Alarm Indication Charging Battery Battery Mode Battery Low Audible Noise at 1 m (3 ft) Temperature Orange LED on Green and Orange LED off, Red LED flash, Alarm slow beep Green and Orange LED off, Red LED flash, Alarm fast beep <45dB 0 to 40 C (+32 to +104 F) Environment Humidity 0% - 90% Non- Condensing 7

MM-AVR600, MM-AVR800, MM-AVR1200 User s Manual Uninterruptible Power Supply (UPS) Physical Net Weight Net Dimension (W D H) Shipping Weight Shipping Dimension (W D H) 15.4Lbs (7.0 Kgs) 3.7x12.6x6.4 94 320 162mm 17Lbs (7.5 Kgs) 5.7x14.8x9.6 145 375 245mm 16.5Lbs (7.5 Kgs) 3.7x12.6x6.4 94 320 162mm 18Lbs (8.0 Kgs) 5.7x14.8x9.6 145 375 245mm 28.7Lbs (13 Kgs) 4.9x15.0x8.9 124 382 225mm 31Lbs (13.7 Kgs) 7.5x18.1x11.8 190 460 300mm Outlets 3: NEMA 5-15R 4: NEMA 5-15R 8

OBTAINING SERVICE If the UPS requires Service: 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax Minuteman Technical Support at the following numbers; Voice phone (972) 446-7363, Fax line (972) 446-9011 or Contact Minuteman UPS at mmsupport@minutemanups.com. Please have the following information available BEFORE calling the Technical Support Department: A. Your name and address. B. Where and when the unit was purchased. C. All of the model information about your UPS. D. Any information on the failure, including LEDs that may not be illuminated. E. A description of the protected equipment, including model numbers if possible. F. A technician will ask you for the above information and, if possible, help solve your problem over the phone. In the event that the unit requires factory service, the technician will issue you a Return Material Authorization Number (RMA #). G. If the UPS is under warranty, the repairs will be done at no charge. If not, there will be a charge for repair. 4. Pack the UPS in its original packaging. If the original packaging is no longer available, ask the Technical Support Technician about obtaining a new set. It is important to pack the UPS properly in order to avoid damage in transit. Never use Styrofoam beads for a packing material. A. Include a letter with your name, address, daytime phone number, RMA number, a copy of your original sales receipt, and a brief description of the problem. 5. Mark the RMA # on the outside of all packages. The factory cannot accept any package without the RMA # marked on the outside. 6. Return the UPS by insured, prepaid carrier to: Para Systems Inc. MINUTEMAN UPS 1455 LeMay Drive Carrollton, TX 75007 ATTN: RMA # 9

MM-AVR600, MM-AVR800, MM-AVR1200 User s Manual Uninterruptible Power Supply (UPS) LIMITED PRODUCT WARRANTY Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials (excluding the Batteries) or workmanship for a period of two years from the date of purchase. Para Systems Inc. (Para Systems) warrants the Batteries for a period of one year from the date of purchase. For equipment sites within the United States and Canada, this warranty covers repair or replacement of defective equipment at the discretion of Para Systems. Repair will be from the nearest authorized service center. Replacement parts and warranty labor will be borne by Para Systems. For equipment located outside of the United States and Canada, Para Systems only covers faulty parts. Para Systems products repaired or replaced pursuant to this warranty shall be warranted for the unexpired portion of the warranty applying to the original product. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. The warranty shall be void if (a) the equipment is damaged by the customer, is improperly used, is subjected to an adverse operating environment, or is operated outside the limits of its electrical specifications; (b) the equipment is repaired or modified by anyone other than Para Systems or Para Systems-approved personnel; or (c) has been used in a manner contrary to the product s User's Manual or other written instructions. Any technical advice furnished before or after delivery in regard to use or application of Para Systems s equipment is furnished without charge and on the basis that it represents Para Systems s best judgment under the circumstances, but it is used at the recipient s sole risk. Except as provided herein, Para Systems makes no warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose. Some states do not permit limitation of implied warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Para Systems is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost of substitutes, claims by third parties, or otherwise. The sole and exclusive remedy for breach of any warranty, expressed or implied, concerning Para Systems s products and the only obligation of Para Systems hereunder, shall be the repair or replacement of defective equipment, components, or parts; or, at Para Systems s option, refund of the purchase price or substitution with an equivalent replacement product. This warranty gives you specific legal rights and you may have other rights, which vary from state to state. Longer-term warranties are available at an extra cost. Contact Para Systems (1-972-446-7363) for details. 10

For more information, contact us at: MINUTEMAN UPS / Para Systems, Inc. 1455 LeMay Drive Carrollton, Texas 75007 Tel: (972) 446-7363 Fax: (972) 446-9011 Email: mminfo@minutemanups.com Web: www.minutemanups.com UPS Sizing: www.sizemyups.com Entire contents copyright 2006 MINUTEMAN UPS / Para Systems, Inc. All rights reserved. Reproduction in whole or in part without permission is prohibited. PN: 34000302