Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

Similar documents
Uninterruptible Power System

General Precautions. Personnel Precautions

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Uninterruptible Power System

User Manual Rittal PMC UPS 6kVA

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Uninterruptible Power System

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Uninterruptible Power System

USER MANUAL MPS 1-5KW SERIES

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

AC CONVERTER / BATTERY CHARGER

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

OWNER S MANUAL POWER INVERTER

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

OutdoorXUPS-600AHV-8364

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

SCC-MPPT Solar Charge Controller

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

SCC-MPPT Solar Charge Controller

230VAC Power Inverter 400W Owner s Manual

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

SCC-MPPT Solar Charge Controller

Sinewave Inverters. SWING 150VA and 300VA. User s manual

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Pure Sine Wave Inverter 600W-24V User Manual

Power Inverter 400 MW Owner s Manual

GSL Electronics Modified Sine Wave Power Inverters

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

BRAVER UPS. (Uninterruptible Power System) User s Manual

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Solar Charge Controller

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

NEWTECH PRO X KVA DSP LCD 1/1 ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Pure sine wave charger inverter Product Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

User Manual. 6K/10K Online UPS with Isolation Transformer. Uninterruptible Power Supply System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Installation and Operation Back-UPS BX550CI-CN

RVS-AX Instruction Manual

MICROCARE 3 PHASE INVERTER MANUAL

PureSine 150/300 Pure Sine Wave Inverter User s Manual

User Manual. EGL - 6K/10K Online UPS. Uninterruptible Power Supply System

Low Frequency Pure Sine Wave Inverter. Operatinal Manual

User Manual. PF0.9 6K/10K Online UPS

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Sola/Hevi-Duty S3K Series Mini-Tower UPS

I. Safety precautions

User Manual. 3/1 10K~30K Online UPS

Transfer Switch GPTS 30

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

MM-AVR UPS Series User s Manual

400 Watt Backup Power System Owner s Manual

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

User s Manual. Automatic Switch-Mode Battery Charger

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Back-UPS CS Back-UPS CS 350

PI1500X Power Inverter User s Manual

c-go 24V/6A 24V/8A 24V/12A

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Solar Hybrid Inverter SP Brilliant Series

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

WARNINGS, CAUTIONS AND NOTES

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Microcare Inverter Manual

Uninterruptible Power Supply

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

User Manual. 6K/10K Online UPS with Isolation Transformer

The Power of Reliability INSTRUCTION MANUAL

Phoenix Inverter

Transfer Switch TS-50. Owner s Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

1200W INVERTER GENERATOR

Installation and Operation Manual Back-UPS BX1100CI-CN

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

K10. Technical Sheet

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

K50. Technical Sheet

CALTRAP INSTALLATION AND OPERATIONS MANUAL

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Transcription:

Contents 1 Introduction...1 2 Safety...4 3 Product Specifications...6 Outdoor UPS User Manual 4 Installation...8 4.1 Inspection...8 4.2 Installing the UPS Cabinet...8 4.3 Connecting the Power Supply...10 5 Operation...12 5.1 Turning-on...12 5.2 Switching-off...12 5.3 Panel Indications...12 6 Maintenance...13 7 Repair...14 8 Trouble Shooting...15 9 Adjusting the Charging Current...16 Please read carefully this manual before installing and using this product 1

1. INTRODUCTION 1.1 Acknowledgements Thank you for purchasing the outdoor UPS produced by OPTI-UPS. This product will provide the best protection for your equipment. This manual provides instructions on the installation and operation of this UPS. You will also find important safety instructions in this manual and we strongly recommend you to follow them carefully. If there are any problems, please refer to the trouble-shooting guide in Chapter 9 before contacting OPTI-UPS. 1.3 Features The advanced charging loop design helps to prolong the life of the batteries and ensures that the batteries are fully charged. Equipment overload can be detected by UPS while it is working in normal or battery mode. The fan will automatically start once the UPS internal temperature rises to maintain the cooling required by the vital circuits of the UPS. Automatic voltage regulator, surge protection, back-up power source, and noise filter. CAUTION: You need to carefully read this manual before ever using the UPS for the first time. You will need to install, operate, maintain, and store this UPS according to the instructions given in this manual. Keep this manual for future reference. Keep all of the packaging materials to protect the UPS in case you would need to transport it. Warranty will not cover UPS damaged from inadequate packaging. 1.2 Working Principle The UPS is designed to protect your equipment from power disturbances. The UPS filters power line noises and surges, while at the same time it charges the batteries. It regulates the voltage by automatically adjusting the output to a safe level when the incoming voltage is either too high or too low. In case of power outage, the UPS will derive power from the batteries allowing continuous operation of your equipment(s) and when the electricity returns, the UPS will automatically shift the load to the utility power and starts to recharge the batteries. 2 3

2. SAFETY 2.1 Manual DO NOT THROW AWAY. This manual contains important instructions and procedures on the installation and maintenance of the UPS and its batteries. 2.2 Protection The UPS is waterproof, but should not be used in areas where water could flood the unit. After installation or maintenance is completed, lock the cabinet to ensure that the UPS is properly sealed. 2.3 Handling The batteries and UPS should be packed separately during transportation. Avoid violent shaking and bumping. Handle it lightly. Keep the UPS and batteries in an upright position.. CAUTION DO NOT try to open the battery in any way. It contains harmful chemicals. To change the batteries, please contact the local seller or service center for a qualified technician. Only change with the same type of battery. Disposing of the battery: Please follow your local, state and federal laws. Battery contains lead and other chemicals that must be disposed of properly. 2.5 Installation and Usage Safety CAUTION: Input power source must be properly grounded. Please see the product specifications for rated load. Do not overload. This outdoor UPS should not be connected with other loads (especially inductive loads). For your personal safety do not open and repair the UPS by yourself. Seek a professional. The unit must be handled with care. 2.4 Battery CAUTION: Keep batteries away from any flame sources to avoid explosion. CAUTION: To prevent electric shock, use caution when disposing or handling batteries. Please follow these instructions. DO NOT wear a watch, ring, or any other metal article Use tools with insulated handles Wear rubber gloves and shoes DO NOT put any tools or metal objects on the battery MAKE SURE that the reset button is off before installing or disconnecting the battery terminal. 4 5

3. PRODUCT SPECIFICATIONS Input Output Protection & Filtering Battery Indicators Model Name OD330 OD330-AL OD500 OD1000 Capacity 330 VA / 200 W 500VA/300W 1000VA/600W Voltage 120V/220 Vac ± 30 % Frequency 50/60 Hz ± 10 % auto sensing Voltage (on battery mode) Square wave 220 Vac ± 5 % Frequency (on battery mode) Automatic voltage adjustment Transfer Time Surge protection Overload protection EMI RFI filter Short circuit Battery low voltage Too hot Higher or lower voltage Quantity Charging current Battery protection Mains electricity normal Battery mode Battery / UPS fault Working environment Environment Working noise Storage Weight kg (excluding the battery) Dimensions W D H Physical including installation support and handle Connections 50/60 Hz ± 1 Hz When the input voltage is 9 % to 15 % lower than the utility, the UPS automatically boosts the voltage by 15 % When the input voltage is 9 % to 15 % higher than the utility, the UPS automatically bucks the voltage by 13 % 4ms (typical) 250 J 2 m s When the load is more than 110%, the UPS will automatically shut down in 60 seconds When the load is more than 130%, the UPS will automatically shut down in 3 seconds 10 db at 0.15 MHz, 50 db at 30 MHz Immediately cut off the input or output circuit breaker protection Low voltage discharge protection, battery failure warning Automatically turn on the cooling fan Switch to battery mode 1 * 12V batter 2 * 12V batteries parallel connection 5A/10A/15A/20A 2 * 12V batteries Series connection Discharge low voltage protection, battery failure warning Green light is on Orange light is on Red light is on -20 60, highest 3500m, 0 95% (without condensation Net weight 16 Gross weight 18 535 310 580 mm < 40db 1 meter away from the UPS surface 0 to 15000m Net weight 23 Gross weight 25 Net weight 25 Gross weight 28 535 310 870 mm Wirable terminal blocks 4.1 Inspection Please inspect UPS immediately for missing parts or other problems. Should there be any damage, please notify the seller. 4.2 Installing the UPS Cabinet Electric pole installation: Anchor Ear Installation. Behind the UPS cabinet are 2 installation poles. Please pick the size of the installation poles that you will need. H-pole installation: Fastening Screw Installation. Below the UPS cabinet are 2 installation poles. The UPS is placed on the H-pole, and four fastening screws are used to fix the UPS cabinet. Wall installation: Expanding Screws plus A-Frame Installation. The expanding screws are fixed on the wall according to the distance of four installation holes. Then the A-frame will be installed and fastened on the 2 installation poles below the UPS cabinet. 6 7

Ground installation: Expanding Screws Installation. The expanding screws are fixed on the ground according to the distance of four installation holes. Then the UPS machine cabinet will be installed and fastened on it. 4.3 Connecting the Power Supply CAUTION Please operate strictly according to the following steps! This is to ensure personal safety and longevity of equipment. WARNING: The switch on UPS is used to control the battery supply, but not the utility supply and the UPS output. The utility input is controlled by an additional external air circuit breaker. If you want to do maintenance inside the equipment, you must first turn off the external air circuit breaker to disconnect the HIGHLY RECOMMEND No matter which installation method is used, keep the UPS cabinet horizontal. utility input power supply. Also, turn off the inverter and the battery connection inside the unit. 1. Inspect the external air circuit breaker connected to the UPS input terminal and the internal RESET switch to ensure that they are off. 2. Open the UPS cabinet door. Pull the utility AC input cables into the line hole on the bottom of the UPS cabinet, and connect it according to the marker on the terminal block; 3. Pull the AC output cables into the line hole on the bottom of the UPS cabinet, and connect it according to the marker on the terminal block. (The input and output cables need to be pulled through different line holes and connected separately). 4. Place the battery into the machine cabinet. Connect the red and black battery cables, to the positive and negative poles on the battery, respectively. Ensure that they are tightly fixed. The inverter of this UPS has two working voltages, 12VDC and 24VDC. Make sure that the voltage is correct before finalizing the connection. 8 9

5. Check each connection on the battery terminals to make sure that they are tight and correct. Also check to see whether the input and output cables are not interchanged, and last, check to see that the voltage is correct. 6. Turn on both the external air circuit breaker and internal reset switch to connect the UPS to the utility power. Then press the power on button longer than 1 second. After the UPS is on, check to see if the output voltage and frequency is correct. 7. To see if the output voltage, frequency and panel displays are all working correctly. Please turn on and off the utility input power several times. 8. To shut down the UPS, hold the power off button longer than 3 seconds. 9. Make sure to connect the load only after switching off the external input air circuit breaker to ensure that the UPS is isolated from the utility power. 9. Repeat step 6. 10. Turn on the load switch. 11. Repeat step 7. 12. Close and tightly lock the UPS cabinet door after making sure that the UPS and load are working normally; 5. OPERATION Neutral output cable Line output cable Neutral input cable Line input cable Ground wire 5.1 Start Press the power on button for more than 1 second and the UPS will start 5.2 Shut down Press the power off button for more than 3 seconds and the UPS will shut down. Input no-fuse switch Battery failure indicator light Battery mode indicator light Mains electricity supply indicator light On-off switch usage. RECOMMEND Please remember to keep the key for future 5.3 Panel Indications When the utility supply is normal-------------------------------------------green light is on When the utility power is off or abnormal--------------------------------orange light is on When there is a faulty on the UPS--------------------------------------------- red light is on 11 10

6. MAINTENANCE 6.1Maintenance Keep the UPS in an upright position. Inspect on a regular basis whether screws are loose. It is recommended that the UPS be installed in a ventilated area. It will help to prolong the life of the battery. When changing the batteries, it is recommended to use batteries that have the same specifications. A regular maintenance check is required when there is no power failure for a long time. The utility input power should be turned off purposely to discharge the batteries (the discharge period depends on the load and the batteries). Restore the utility input to charge the batteries for no fewer than 6 hours each time. When the temperature is lower than 30, discharge the batteries every 3 months; when the temperature is higher than 30, discharge every 2 months. 6.2 Storage Store the unit in a dry environment. The temperature should be lower than 50, and the humidity not more than 90. Charge the batteries for at least 6 hours before storage to keep it full. Disconnect the cables connecting the UPS circuit and the battery before storage. Batteries must be recharged after being stored for more than 3 months and every three months thereafter. 7. REPAIRING 7.1 Eliminating the Malfunctions In chapter 8 there are answers to some basic problems that may help you to trouble-shoot your UPS. Please read them before contacting OPTI-UPS service center. 7.2 Obtaining Repair Services Please provide the UPS model and serial number, date of purchase and the invoice. Also describe the problems that you have encountered on the UPS. Please ship back using the original box. 7.3 Warranty Within the warranty period the UPS will be repaired free of charge. The damages resulting from lack of packaging materials in sending the UPS back for repairing are excluded from the warranty. Attention: The following are some conditions that are not covered under warranty. Charges will be applied by the following formula. (charging standard repair charge parts charge shipping expenses): Handled improperly or not according to the product user manual Taking the UPS to a repair shop not authorized by OPTI-UPS after the failure occurs, Purposely damaging the UPS Failures due to unexpected events or accidents (such as fire, flood, earthquake, lightning strike, gas explosion, and war 13

8. TROUBLE-SHOOTING 9. Adjusting the Charging Current Problem Possible reasons Recommendation The pressing time is too short. Press the button continuously for more than 3 seconds. The UPS will not The battery voltage is low or the Check the battery connection and start after the power battery wires are loose or restart the UPS after charging the button is pressed disconnected. battery for 24 hours. The fuse on the main circuit board Call the service center. Can t shut down the UPS Even if the mains electricity is normal, the UPS keeps being powered by the battery is burned out. Internal UPS failure. The input power cables are loose or disconnected The input power circuit breaker switches off. No input power The input voltage is too high or too low, deformed or the frequency is unstable, or has surpassed the acceptable range of the UPS. Contact the agent or service center. Connect the power lead and restart the UPS Reduce the UPS load or solve the short circuit problem. Reset the circuit breaker and restart the UPS. Check the input power supply. Improve the power supply condition. The batteries are not fully charged. Continue charging for 24 hours, The battery back-up A power failure occurred recently. and test the discharge again. time is shorter than The battery has approached the end Contact the agent or repair had been expected of its useful life. center. The UPS is overloaded. Reduce the UPS load. 9.1 When there is no jumper in either JP1A or JP2A, the charging current is 10A. 9.2 When a jumper is inserted in either JP1A or JP2A, the charging current is 15A. 9.3 When a jumper is inserted in both JP1A and JP2A, the charging current is 20A. 14