team master medium voltage solid state starters

Similar documents
Features and Benefits. Control Features

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

CTi Automation - Phone: Fax: Web:

RVS-DN Digital Reduced Voltage Motor Starter

Intelligent Low Voltage Solid State Motor Control Products. with next generation MX 2 /MX 3 technology. Low Voltage Solid State Starters

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

RVS-DX Digital Reduced Voltage Motor Starter

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Motorpact Medium Voltage Motor Controller. Innovative solutions that deliver high performance and reliability

Solid State Starters. Standard and Combination Packages. NEMA 4/ 12 Units are Designed for Crusher Applications

Intelligent Medium & High Voltage Motor Control Solutions

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

825-P Modular Protection System for motors Specification Guide

MaxPak Plus Analog DC V S Drive

Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

PRODUCTS OVERVIEW MOTORS CONTROLS GEARBOXES SERVICE

SECTION MOTOR CONTROL

Application Description

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd

HVW701 HVAC Drive with By-Pass

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

AuCom - Soft Starters

C1000 Series Automatic Cap Bank

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.


Product Overview. Soft Starters Motor Protection Control and Measurement. Solcon Industries Ltd.

MVC4MEDIUM VOLTAGESOLIDSTATESOFTSTARTER

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

CWM_N NEMA Rated Contactors

Diesel generator set QSK95 series engine

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Sensorless Vector Drives

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

Complete Range of Soft Start / Motor Control, Motor Protection & Control Solutions

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Rental Power QSL9 series engine

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

SINAMICS GM150 IGCT version

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Softstarters. Softstarters Power electronic brakes Type PEB

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

SOLSTART Instruction Manual

BAC Custom Engineered Controls

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

SECTION 16349X MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

EPS-ECONOMY PUMP STARTER

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

HVAC-R Drive Products

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Intelligent Medium & High Voltage Motor Control Solutions with next generation MX 3 technology

Diesel Generator set QSK95 series engine

Diesel Generator set QSK95 series engine

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Design Standard. Purpose: Design Standard:

Motor Basics AGSM 325 Motors vs Engines

MCD 200 Series Soft Starters

Table of Contents. Chapter 1: Introduction 1.1 General Description 1. Chapter 2 - Installation 2.1 Receiving and Unpacking.. 5

Product Description. Application Description

RVS-AX Instruction Manual

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

MOTOR CONTROL IS OUR NATURE PRODUCT GUIDE

SECTION MOTOR CONTROLLERS

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Hp V AC Current Rating [A] 230V AC 60 Hz

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

AUCOM NORTH AMERICA. Complete range of motor starting solutions

Dimensions WxHxD [mm] Weight [kg]

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Designed for ease of integration with automation systems

Diesel generator set QSK60 series engine

Electric Motor Controls BOMA Pre-Quiz

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Diesel generator set QSK60 series engine

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Tier4 certified diesel generator set QSK78 series engine

MOTOR TERMINAL CONNECTIONS

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Size for Size Best Value in the Industry

Transcription:

team master medium voltage solid state starters

The Today s global economy is in many ways driven by the AC Induction Motor. Industrial facilities worldwide depend on these motors to drive the machinery that enhances their efficiency and increases their production output. However, many industrial operations unknowingly subject their machinery to severe stress during motor start-up. When motor operation is activated, high inrush currents flow into the motor s windings, producing very Advantage TEAMmaster medium voltage soft starters provide several advantages including: Protection of machinery from failure and excessive maintenance caused by mechanical shock during starting or stopping. The TEAMmaster provides smooth, stepless acceleration and controlled deceleration. Control of the current ramp during start-up. The TEAMmaster protects electrical systems from disruptive voltage drops and power outages caused by motor locked rotor inrush current. Complete line monitoring, motor control and protection. These functions protect mission-critical motors from failure or unscheduled outages caused by machine or electrical system faults. high levels of torque. This torque at the motor s shaft can result in a substantial shock to the driven equipment. The result may be belts slipping or breaking, couplings disengaging, and gears or other components failing completely. Programming capabilities. The TEAMmaster includes control and power electronics, as well as bypass and isolation contactors that reduce maintenance and operating costs. A UL listing and a CSA approval. Therefore, it is often a cost-effective decision to protect your machinery investment with a TEAMmaster medium voltage soft starter. Available only from TECO- Westinghouse Motor Company, the TEAMmaster protects your machinery by controlling motor torque. The TEAMmaster also reduces current demand and creates a more stable line voltage, which benefits facilities that have weak electrical systems.

The TECO Westinghouse Integrated Protection Plan When a TEAMmaster starter is purchased and installed with a new TECO Westinghouse Motor Company motor, we will offer a three-year warranty on both the motor and the TEAMmaster starter. Precision-Engineered Products TECO Westinghouse Motor Company can offer custom TEAMmaster starters to match your specific requirements, including: Specified enclosures Control and protective devices Surge and lightning protection Power factor correction capacitors Integrated machine or process controls TEAMmaster Applications Stand Alone Solid State Across Programmable Synchronous Reduced the Electronic Excitation MOTOR TYPE Voltage Line Reversing Braking Package INDUCTION SYNCHRONOUS 2 SPEED 1-WINDING 2 SPEED 2-WINDING WOUND ROTOR TEAMmaster Specifications and Ratings KV MAX. HP 5 8,000 OPTIONAL OPTIONAL 400 60 7.2 10,000 N/A 600 75 15 20,000 * * N/A N/A SIZED TO 95 SYSTEM * Vacuum breaker.

The TEAMmaster is Rugged and Dependable TEAMmaster enclosures are manufactured from welded heavy-gauge steel that is coated with industrial-grade paint. Lifting brackets and sidewall panels for linking adjacent units are conveniently removable. TECO Westinghouse Motor Company will provide the proper enclosure for your environment, with an optional incoming line tophat or low-voltage control/ RTD wireway, including: Chassis NEMA 1 NEMA 12 NEMA 12V NEMA 3R NEMA 4 Marine duty Each enclosure is divided into separate compartments: 1. The medium-voltage power section (5 KV-15 KV) is located in the main body of the enclosure. A mechanical interlock prevents entry until the power is off and the isolating switch is grounded. This section houses the medium-voltage fuses, power stacks, isolation and bypass contactors and other MV components. 2. The low-voltage control section is an isolated compartment. The control signals are fiber-optically isolated from the medium voltage signals. Low-voltage power is transformerisolated from medium-voltage on 5 KV units and fiber-optically isolated on 7.3 KV and 15 KV units. 3. The disconnect section houses the lockable rotary operated fault make/load break disconnect switch and includes a window for disconnect verification. 4. Horizontal power bus is braced for a short circuit rating of 400 MVA on 5 KV units and matched to the electrical system requirements for 7.2 KV and 15 KV units. 5. Specified bus configurations. TEAMmaster starters will be provided with the exact bus configuration, ratings and protection you specify: Copper or aluminum 800/1200/2000 amp Top or center mount Environmentally or electrically insulated Custom retrofit arrangements Higher BIL ratings (45/60 KV standard) Front access copper ground bus 2 1 4 3 6. Specified control and protective devices. In addition to the array of standard features included with every TEAMmaster starter, TECO Westinghouse Motor Company can engineer and integrate the control and protective devices you specify, including : Protective relays RTD monitors Third-party motor protection packages Pilot devices/plcs 7. Specified surge capacitors and lightning arrestors. TECO Westinghouse Motor Company can design, mount, and test (as an integrated unit) surge capacitors and lightning arrestors to match your electrical system and lightning protection requirements. 8. Load engineered power factor capacitors and controls. TECO Westinghouse Motor Company can engineer and integrate the proper PF correction capacitors to match your specific motor requirements, including single or multiple units with integrated controls for: Start/run sequencing Load matching 7 5 8 6

TEAMmaster Dimensions 2300 VOLT TYPICAL STANDARD STANDARD W/DISCONNECT HORSEPOWER unit: inch unit: inch @ 2300V FLA H W D H W D 150 36 92 36 32 92 36 32 500 120 92 36 32 92 36 32 750 180 92 36 32 92 36 32 1250 300 92 36 32 92 36 32 1500 360 92 36 32 92 45 32 1750 420 92 45 32 92 45 32 2250 540 92 60 32 92 126 32 2750 660 92 60 32 92 126 32 4160 VOLT TYPICAL STANDARD STANDARD W/DISCONNECT HORSEPOWER unit: inch unit: inch @ 4160V FLA H W D H W D 300 40 92 36 32 92 36 32 1000 133 92 36 32 92 36 32 1500 200 92 36 32 92 36 32 2500 333 92 36 32 92 36 32 3000 400 92 36 32 92 45 32 3500 467 92 45 32 92 90 32 4500 600 92 60 32 92 126 32 5000 666 92 60 32 92 126 32 5500 734 92 60 32 92 126 32 6000 800 CF CF CF CF CF CF >6000 CF CF CF CF CF CF CF CF = Consult Factory. Consult Factory to obtain product dimensions for ratings above 4160V.

TEAMmaster Programmable Controller Unlike other forms of reduced-voltage starting, the TEAMmaster control and power hardware, software, and sensors are designed to perform as an integrated control system. This eliminates the uncoordinated performance problems inherent with multiple, dissimilar components. TEAMmaster starters are equipped with a built-in, self-test (BIST) standard. This enables the user to completely test the mechanical and electrical sequencing of the starter at low voltage, prior to applying medium voltage power. The unit is easily programmable from its display keypad using simple, intuitive commands. Parameters, ranges, settings, fault messages, and metering functions are instantly shown on a two-line, 16-character, backlit display. The entire hardware set is controlled and protected by a realtime clock and battery-backed memory. I. TEAMmaster modular hardware The following modules are configurable to match your motor control requirements: Standard Hardware Modules Voltage divider Microprocessor control Power supply and I/O Display/programming Optional Hardware Modules Expanded aux. Relays Communications Reversing and synchronization RTD monitor Predictive maintenance II. Over 100 Selectable Functions The TEAMmaster provides over 100 programmable, selectable functions, standard integrated control and protection software that allows the user to select from the broadest range of functions available anywhere. Features include: Programmable Motor Protection Electronic overload Selectable class 5/10/15/20/25/30 Overload warning Electronic shear pin Motor short circuit/ioc Zero speed switch input Under/over voltage protection Machine ground fault protection Single/reverse phase protection Undercurrent/unbalance protection Programmable Motor Control Programmable torque or current ramp Programmable ramp to current limit Initial current limit Maximum current limit Start/ramp time Selectable motor service factor Fully programmable linear of S curve deceleration Auxiliary motor/feeder control Current limited jog Restart block-backspin timer Embedded Diagnostics and Self-Protection Pre-start Built-In Self Test (BIST) System fault diagnostics and display Self diagnostics and display Date-and-time stamped fault logging Revolving 99 event data recorder Power loss fault memory retention/lockout Start/stop recorder Pass code protected Embedded Digital Metering and Monitoring Selectable view-all keypad display Volts/amps/frequency KW/KWHR Elapsed time KVAR/power factor Motor thermal capacity utilization Communications/Supervisory Control Options RS232/485 Supervisory control and data logging PLC interface Real time clock Year 2000 compliant Remote OL/CPU reset

III. 15 KV Rated, Fiber Optically Controlled Power Stacks * 1. Fiber-optic firing control isolates low and high voltage. TEAMmaster starters have a precision fiber optic firing control system that completely isolates low and high voltage signals. This ensures electrical reliability providing: Complete noise immunity Control signal isolation and integrity Precision firing of series SCRs 1 2 2. Draw-out integral plenum power stacks provide maximum reliability. TEAMmaster starters are provided with a unique draw-out/integral plenum power stack design, which completely isolates phase to phase and interphase power electronic devices. This design also provides a positive flow plenum insuring power module reliability: Power module isolation Integral positive cooling Modular power-pole replacement * Standard on 7.2 KV and 15 KV units and optional on 5 KV units.

TEAMmaster Starters are designed for use with medium voltage motors such as TECO Westinghouse Motor Company s World Series and Synchronous motors. Ask about our 3-Year Integrated Protection Plan. WORLD SERIES MOTORS Rugged thru-bolt copper or copper alloy rotor bar construction and end rings Form wound windings with minimum of two complete VPI cycles Anti-friction or spherically seated Renk split sleeve bearings High efficiency designs reduce life-cycle costs Thermalastic epoxy insulation stator insulation system API 541 design available Available up to 30,000HP SYNCHRONOUS MOTORS Renk split-sleeve bearings Brush excitation or brushless excitation Thermalastic epoxy insulation stator insulation system Available in high speed and slow speed designs Available for adjustable frequency AFAC applications Available up to 100,000HP D I S T R I B U T E D B Y : www.tecowestinghouse.com PO Box 277 (78680-0277) 5100 N. IH 35 Round Rock, Texas 78681 1-800-451-8798 http://www.teco-wmc.com 12/98