for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D

Similar documents
EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

LINEAR DIFFUSERS AND BAR GRILLES

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

INDEX. Chapter3. air master. Linear Bar Grilles

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

RPD ROUND PLAQUE DIFFUSER

INDEX. Chapter2. air master. Grilles and Registers

LINEAR DIFFUSERS AND BAR GRILLES

EGG CRATE RETURN GRILLE

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

LOUVERED FACE GRILLES AND REGISTERS

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.

MODULAR CORE CEILING DIFFUSERS

Application Guidelines

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

LINEAR SLOT DIFFUSERS PLENUMS

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

SPD SQUARE PLAQUE DIFFUSER

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

OVERVIEW Combination Supply/Return Diffuser (SARM)

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

HIGH CAPACITY LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

GRILLES AND REGISTERS

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

GRILLES AND REGISTERS

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Total comfort control

MOTORIZED VOLUME DAMPER

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Application Guidelines

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

GRILLES AND REGISTERS

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

SPD/SPDV SPD SPDV. High Velocity/High Aspiration Air Outlet. Construction

GRILLES AND REGISTERS

Ventilation grilles for installation into walls, sills or rectangular

INDEX. Chapter1 1. A. Jet diffusers 1. Jet diffuser...: AJD-P

GRILLES AND REGISTERS

J1-2. Table of Contents RETURN GRILLES

Ventilation grilles for installation into walls, sills or rectangular

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Series DD & SD-20 Supply Grilles & Registers

series Linear grilles

LINEAR DIFFUSERS AND BAR GRILLES

CONCENTRIC Product Information & Applications

DCG Adjustable Aluminum Round Diffusers

Wall and Ceiling Grille

A1GRILLES & REGISTERS

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

CEILING DIFFUSERS D12 CEILING DIFFUSERS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof

Redefine your comfort zone. chilled beams. energy solutions

CEILING DIFFUSERS CEILING DIFFUSERS

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

PC-125x Counter-Balanced Backdraft Damper

Air Handling Reference Catalogue

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

WE GUIDE AIR LOUVERS

FlowBar High Capacity Slot Diffuser

PATTERN CEILING DIFFUSERS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

GRILLES AND REGISTERS

makes sure products are delivered Products are offered in steel,

Linear Slot Diffusers Model Slot 20 & Model Slot 25

VANEAXIAL & TUBEAXIAL FANS

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

GRILLES AND REGISTERS

LINEAR SLOT DUFFUSERS

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Airline Linear Grilles

Linear Slot Diffusers Model Slot 20 and Model Slot 25

KLIMA Active Chilled Beams

M1-2. Table of Contents INDUSTRIAL GRILLES. 680, 5680, 6880, 56880, 680MP, 5680MP Introduction... M1-3 Dimensional Data... M1-4

CEILING DIFFUSERS CEILING DIFFUSERS

Price O.R. Systems AIR CURTAIN SYSTEM

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

GRILLES AND REGISTERS

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

Premium Correctional Air Distribution. The First Name in Air Diffusion.

PERFORATED CEILING DIFFUSERS

GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS

Transcription:

for Pleasant & Healthy Air-Distribution ISO 90012000 Product Bulletin 135-D Linear Bar & Floor Grilles

Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health

INTRODUCTION DASCO Linear Bar Grilles and Registers covers a wide range for supply and return air distribution of HVAC systems and are suitable for ceiling, floor, sill and sidewall applications. They are selected for their pleasing continuous, line architectural appearance and are designed for fan tops, grilles of swimming pools, ventilation outlets and many other applications. 1 Introduction

LINEAR BAR GRILLES & REGISTERS GENERAL DASCO Linear Bar Grilles and Registers DLB (G,R) covers a wide range for supply and return air distribution of HVAC systems and are suitable for ceiling, floor, sill and sidewall applications. They are selected for their pleasing continuous line architectural appearance and are designed for fan tops, grilles of swimming pools, ventilation outlets and many other applications. Bar Grille DLBG - 30-2W DESCRIPTION DASCO Linear Bar Grilles & Registers are multiparallel fixed bar type in continuous modular section up to 5 meters long to form linear type grilles. They are available in one way airflow pattern for zero degree bar deflection and in one or two way air flow pattern for (15 ) & (30 ) bar deflection. DLB (G,R) standard widths ranges from 3 to 12 (76mm-305mm). For quiet airflow, bars are equally spaced at 12.5mm (1/2 ) distance Flat frames are standard but curved frames on request can be supplied for all models. Mullion bars across the blades provide additional strength. Mitered corners available in various arrangements to suit different installations. Mitered Corner (90 angle) Mitered Corner (135 angle) 2 Linear Bar Grilles

MATERIAL & FINISH High quality extruded aluminium sections in matt silver anodized finish. White colour in electrostatic polyester powder coating finish available as standard. Other colours as per RAL standards are also available upon request. PRODUCT CODE (ORDERING KEY) DASCO LINEAR BAR GRILLES & REGISTERS DLBX D A W L X G R D O Oy 15 30 A 1W 2W TYPE Grille Grille with V.C.D. (Register) Deflection Angle Zero degree deflection Zero degree deflection (Special blade) 15 degree deflection 30 degree deflection Air pattern One-way deflection Two-way deflection W L Width of neck (inch or mm) Length (inch or mm) 3 Linear Bar Grilles

Complete dimensional details for DASCO Linear Bar Grille DLBG-15-1W. LISTED WIDTHS Table No (1) Listed Widths Note Sizes other than listed are also available upon request. AREA FACTORS Below is the area factor per foot for DASCO Linear Bar Grilles (Ak) Table No (2) Area Factor (AK) Note For use with alnor velometer with Tip No.2220 or 2220A CFM Ak L Vk = = = = Ak x L x Vk, where Area Factor in Ft 2 /Ft Run Active Length of Linear Bar Grille in feet. Average velocity as measured by Alnor Velometer with Tip No.2220 or 2220A. 4 Linear Bar Grilles

DIMENSIONAL DATA (Linear Bar Grilles) LISTED WIDTH + 58 mm 12.5 mm(1/2 ) 32 mm LISTED + 58 mm 6mm 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) LISTED WIDTH DLBG 0 DASCO Linear Bar Grille with fixed bar 0 deflection 51.5 mm 3 mm(1/8 ) DLBG 0 Y DASCO Linear Bar Grille with fixed bar (special blade) 0 deflection LISTED WIDTH + 58 mm LISTED WIDTH + 58 mm 15 12.5mm(1/2 ) 32 mm 15 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) 51.5 mm 3 mm(1/8 ) LISTED WIDTH LISTED WIDTH DLBG 15 W DASCO Linear Bar Grille with fixed bar 15 one-way deflection DLBG 15-2W DASCO Linear Bar Grille with fixed bar 15 two-way deflection LISTED WIDTH + 58 mm LISTED WIDTH + 58 mm 30 12.5mm(1/2 ) 32 mm 30 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) 51.5 mm 3 mm(1/8 ) LISTED WIDTH LISTED WIDTH DLBG 30-1W DASCO Linear Bar Grille with fixed bar 30 one-way deflection DLBG 30-2W DASCO Linear Bar Grille with fixed bar 30 two-way deflection 5 Dimensional Data

DIMENSIONAL DATA (Linear Bar Registers) LISTED WIDTH + 58 mm 12.5 mm(1/2 ) 32 mm LISTED + 58 mm 6mm 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) 51.5 mm 3 mm(1/8 ) LISTED WIDTH DLBR 0 DASCO Linear Bar Register with fixed bar 0 deflection with opposed blade lever operated damper DLBR 0 Y DASCO Linear Bar Register with fixed bar (special blade) 0 deflection with opposed blade lever operated damper LISTED WIDTH + 58 mm LISTED WIDTH + 58 mm 15 12.5mm(1/2 ) 32 mm 15 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) 51.5 mm 3 mm(1/8 ) LISTED WIDTH LISTED WIDTH DLBR-15-1W DASCO Linear Bar Register with fixed bar 15 one way deflection with opposed blade lever operated damper DLBR-15-2W DASCO Linear Bar Register with fixed bar 15 two-way deflection with opposed blade lever operated damper LISTED WIDTH + 58 mm LISTED WIDTH + 58 mm 30 12.5mm(1/2 ) 32 mm 30 12.5mm(1/2 ) 32 mm 51.5 mm 3 mm(1/8 ) 51.5 mm 3 mm(1/8 ) LISTED WIDTH LISTED WIDTH DLBR-30-1W DASCO Linear Bar Register with fixed bar 30 one way deflection with opposed blade lever operated damper DLBR-30-2W DASCO Linear Bar Register with fixed bar 30 two-way deflection with opposed blade lever operated damper 6 Dimensional Data

ACCESSORIES A complete variety of accessories and options are available for DLB (G,R) series liner Bar Grilles and Registers. 1. Opposed blade Volume Control Damper for supply grilles. 2. Equalized grid. 3. Lining strips for continuous sections. 4. Mitered corner sections. (Available in both horizontal and vertical settings ) Opposed Blade volume control damper. DIFFERENT SETTINGS OF MITERED CORNERS 1. STANDARD 90 HORIZONTAL MITERED CORNER SECTION Suitable for floor, sill or ceiling application. This standard corner section is available in 0, 15º and 30º deflection settings with angle of 90º. When specifying a corner section with 15º or 30º deflection settings, it is important to specify the direction of its throw either towards the insideor outside of the corner. Corner sections are not provided with dampers. 2. SPECIAL HORIZONTAL MITERED CORNER SECTION Suitable for floor, sill or ceiling applications. This special corner section includes an angle greater than 90º and less than 180º and is available in 0º, 15º and 30º deflection settings. When specifying a corner section with a 15º or 30º deflection settings, it is important to specify the direction of its throw either towards the inside or outside of the corner. Corner sections are not provided with dampers. 7 Accessories

3. VERTICAL OUTSIDE MITERED CORNER SECTION Designed for sidewall applications at the junctions of two outside walls. This type of corner section has a standard angle of 90º and is available in 0º, 15º and 30º deflection settings. Corner sections are not provided with dampers. 4. VERTICAL INSIDE MITERED CORNER SECTION Designed for sidewall applications at the junction of two inside walls. This type of corner section has a standard angle of 90º and is available in 0º, 15º and 30º deflection settings. Corner sections are not provided with dampers. Curved Bar Grille (Convex Shape) Curved Bar Grille (Concave Shape) 8 Accessories

BALAING DATA AND SELECTION PROCEDURE HOW TO DETERMINE ( CFM )? 1. 2. 3. 4. 5. 6. Use an Alnor Velometer with tip No. 2220 or 2220A. For outlets less than 3 wide, position tip over center bar and take velocity readings at various points along the length of the liner bar grilles. For outlets greater than 2 1/2 wide, take velocity readings near the outer and center or near center bar at various points along the length of the linear bar grilles. Take a minimum of four equally spaced readings. Average the velocity readings. Select appropriate Ak from table (2). Determine CFM by the following equation CFM = Ak x Active Length x Average Velocity. SAMPLE PROBLEM Determine air flow rate through a 5 wide ( 15º ) 14 feet long supply liner bar grille. The active length is a total of 7 feet. SOLUTION 1. 2. 3. The average of 14 velocity readings taken at various points along the active length of the linear bar grille centered over the next to outer bar and middle bar is 525 fpm. From table (2) the Ak for 5» wide 15º on supply air is 0.19 CFM=Ak x Active Length x Average Velocity =0.19 x 7 x 525 =700 CFM 9 Balancing and Selection

BASIC PERFORMAE DATA DASCO Linear Bar Grille Model DLBG - 0 WIDTH (inch) Area Factor AK ( Ft 2 /Ft) Velocity (fpm) 400 500 600 700 800 1000 1200 1400 1600 Total Pressure (Inch W.G.) 0.009 0.014 0.021 0.028 0.036 0.056 0.08 0.11 0.146 3 0.1 4 0.15 5 0.19 6 0.23 8 0.31 10 0.4 12 0.48 40 50 60 70 80 100 120 140 160 8-14 11-17 13-20 14-22 16-26 20-33 24-39 27-42 30-45 <20 <20 <20 <20 <20 25 28 31 34 60 75 90 105 120 150 180 210 240 10-16 12-19 14-24 18-28 20-31 25-40 30-47 33-50 37-54 <20 <20 <20 <20 <20 26 29 33 36 76 95 114 133 152 190 228 266 304 12-20 15-25 18-29 22-35 25-39 31-48 37-56 40-60 43-64 <20 <20 <20 <20 <20 26 29 34 37 92 115 138 161 184 230 276 322 368 14-21 16-26 20-31 24-37 26-41 32-52 39-62 43-66 46-69 <20 <20 <20 <20 20 26 30 35 38 124 155 186 217 248 310 372 434 496 16-24 18-29 22-33 26-39 27-43 35-55 41-65 46-69 50-73 <20 <20 <20 <20 21 27 31 35 39 160 200 240 280 320 400 480 560 640 18-28 20-32 24-36 28-42 29-45 37-58 43-68 48-74 51-76 <20 <20 <20 <20 22 28 32 36 40 192 240 288 336 384 480 576 672 768 20-30 22-35 26-39 30-45 31-48 39-61 45-69 50-78 55-80 <20 <20 <20 20 23 29 33 37 41 VELOCITY TOTAL PRESSURE THROW Ak Table No. 3 ( 0 Deflection Liner Bar Grille ) Is discharge velocity measured at face of grille in FPM. Is for supply without damper and room effect of 8 db. Is in inch W.G. for supply grille without damper. Is for 8 long supply grille without damper, for 100 and 50 FPM terminal velocities respectively. Is area factor in Ft 2 /Ft Run 10 Basic Performance Data

DASCO Linear Bar Grille Model DLBG - 0 Y WIDTH (inch) Area Factor AK ( Ft 2 /Ft) Velocity (fpm) 400 500 600 700 800 1000 1200 1400 1600 Total Pressure (Inch W.G.) 0.010 0.018 0.025 0.032 0.044 0.064 0.088 0.120 0.157 3 0.97 4 0.145 35 44 53 62 71 88 106 124 142 6-11 9-14 10-16 11-18 13-22 17-27 20-31 23-35 26-39 <20 <20 <20 <20 <20 23 27 31 35 51 64 77 90 103 129 155 181 206 7-13 9-16 11-20 14-23 16-26 20-32 24-40 27-43 30-47 <20 <20 <20 <20 20 24 28 32 36 5 0.186 67 84 101 118 135 169 202 236 271 9-16 11-20 14-25 18-30 21-33 25-40 30-45 34-49 38-54 <20 <20 <20 <20 21 25 29 33 37 6 0.225 83 104 125 146 167 209 251 292 335 11-17 13-22 16-27 20-33 22-37 27-44 30-48 34-53 38-57 <20 <20 <20 20 22 26 31 34 38 8 0.30 119 149 179 208 239 298 359 419 478 13-19 14-24 18-28 22-34 24-38 27-44 31-49 35-52 39-58 <20 <20 <20 21 23 27 32 36 40 10 0.398 151 189 227 265 303 379 455 530 607 15-22 16-22 19-29 22-35 25-38 30-45 33-49 37-54 40-59 <20 <20 20 22 25 29 33 37 41 12 0.478 183 229 275 321 367 459 551 643 735 17-24 19-27 20-30 24-35 37-39 31-45 35-50 39-55 43-62 <20 <20 21 23 26 31 34 38 42 VELOCITY TOTAL PRESSURE THROW Ak Table No. 4 ( 0 Deflection Liner Bar Grille - Special Blade ) Is discharge velocity measured at face of grille in FPM. Is for supply without damper and room effect of 8 db. Is in inch W.G. for supply grille without damper. Is for 8 long supply grille without damper, for 100 and 50 FPM terminal velocities respectively. Is area factor in Ft 2 /Ft Run 11 Basic Performance Data

DASCO Linear Bar Grille Model DLBG - 15 WIDTH (inch) Area Factor AK ( Ft 2 /Ft) Velocity (fpm) 400 500 600 700 800 1000 1200 1400 1600 Total Pressure (Inch W.G.) 0.009 0.014 0.021 0.028 0.036 0.056 0.08 0.11 0.146 3 0.095 4 0.14 5 0.18 6 0.22 38 47 57 67 77 96 115 134 153 8-13 11-16 12-18 13-20 15-25 19-31 23-36 26-40 29-43 <20 <20 <20 <20 <20 25 28 31 35 56 70 84 98 112 140 168 196 224 9-15 11-18 13-22 16-26 19-29 23-37 28-45 31-48 35-51 <20 <20 <20 <20 20 25 29 32 37 72 90 108 126 144 180 216 252 288 11-19 14-23 19-28 21-33 24-38 30-46 35-53 38-57 41-61 <20 <20 <20 <20 21 26 30 34 38 88 110 132 154 176 220 264 308 352 13-20 15-25 19-30 23-36 25-40 31-50 37-58 40-61 43-65 <20 <20 <20 <20 22 27 31 35 39 8 0.3 10 0.39 12 0.47 122 153 184 214 244 304 364 425 486 15-22 17-28 21-32 25-38 26-42 33-53 38-60 42-64 46-68 <20 <20 <20 20 23 28 32 36 40 156 195 234 273 312 390 468 546 624 17-26 19-30 22-34 27-40 28-43 35-55 40-63 44-66 48-70 <20 <20 <20 21 24 29 33 37 41 188 235 282 329 376 470 564 658 752 19-28 21-32 24-36 29-42 30-46 37-56 42-63 46-69 50-75 <20 <20 20 22 25 30 35 38 42 VELOCITY TOTAL PRESSURE THROW Ak Table No. 5 ( 15 Deflection Liner Bar Grille ) Is discharge velocity measured at face of grille in FPM. Is for supply without damper and room effect of 8 db. Is in inch W.G. for supply grille without damper. Is for 8 long supply grille without damper, for 100 and 50 FPM terminal velocities respectively. Is area factor in Ft 2 /Ft Run 12 Basic Performance Data

DASCO Linear Bar Grille Model DLBG - 30 WIDTH (inch) Area Factor AK ( Ft 2 /Ft) Velocity (fpm) Total Pressure (Inch W.G.) 400 500 600 700 800 1000 1200 1400 1600 0.009 0.014 0.021 0.028 0.036 0.056 0.08 0.11 0.146 3 0.09 4 0.13 36 45 54 63 72 90 108 126 144 7-12 10-15 11-17 12-19 14-23 18-29 22-23 25-37 28-41 <20 <20 <20 <20 20 24 28 32 37 52 65 78 91 104 130 156 182 208 8-14 10-17 12-21 15-24 17-27 22-35 26-42 29-46 32-49 <20 <20 <20 <20 20 25 29 33 38 5 0.17 68 85 102 119 136 170 204 238 272 10-18 13-22 16-27 21-33 23-36 29-45 34-50 37-54 40-58 <20 <20 <20 <20 21 26 30 34 39 6 0.21 84 105 126 147 168 210 252 294 336 12-19 14-24 18-29 22-35 24-39 30-47 34-52 38-57 41-60 <20 <20 <20 20 22 28 32 35 40 8 0.29 120 150 180 210 240 300 360 420 480 14-21 16-26 20-30 24-36 25-40 31-49 35-53 39-58 42-61 <20 <20 <20 21 24 29 33 37 41 10 0.38 152 190 228 266 304 380 456 532 608 16-24 18-27 21-31 25-38 27-41 33-50 36-54 40-59 43-62 <20 <20 20 22 26 30 34 38 42 VELOCITY TOTAL PRESSURE THROW Ak 12 0.46 184 230 276 322 368 460 552 644 736 18-26 20-29 22-33 27-39 29-43 35-51 38-56 42-61 46-67 <20 <20 21 24 27 32 36 39 43 Table No.6 ( 30 Deflection Liner Bar Grille ) Is discharge velocity measured at face of grille in FPM. Is for supply without damper and room effect of 8 db. Is in inch W.G. for supply grille without damper. Is for 8 long supply grille without damper, for 100 and 50 FPM terminal velocities respectively. Is area factor in Ft 2 /Ft Run 13 Basic Performance Data

PERFORMAE NOTES DEFINITIONS VELOCITY TOTAL PRESSURE THROW Ak Is discharge velocity measured at face of grille in (FPM). Noise criteria for the supply grille without damper with room effect of 8 db and 8 active length ( see correction values in table No. (7)). Is in inches W.G. for supply grille without damper. Is for 8 active length supply grille without damper for 100 and 50 FPM terminal velocities respectively. ( see throw correction value in table No. (8) ). Is area factor in Ft 2 /Ft Run For other non listed widths, use the following formula Ak = W- 0.85 24, W width in inches CORRECTIONS ( Noise Criteria ) Add 2 db to the tabulated values in case of grille with damper. Add 4 db to the tabulated values for return grilles. For other active lengths, use the following corrections Table No. 7 correction factors ( Noise Criteria ) For grille with damper, multiply the tabulated value by 1.4 For return grilles, multiply by 0.85 Throw For other active lengths use the following corrections Active length (Ft) 1 2 4 6 8 10 12 Multiply throw by 0.60 0.7 0.8 0.9 1.0 1.2 1.4 Table No. 8 Throw correction factors 14 Performance Notes

INSTALLATION DETAILS Here is the most commonly used methods of installing DASCO Linear Bar Grilles/Registers for different site applications ( Ceiling/Side wall/floor) Ceiling Installation Floor Installation Side wall Installation 15 Installation Details

FLOOR GRILLES & REGISTERS GENERAL DASCO Floor Grilles and Registers (DFG -21 H/V & DFR -21 H/V) are designed to be installed on floors where air ducts are required to be underneath the floor level, such as for computer rooms. They are designed to withstand 450 kg. point load for heavy duty applications. Floor grille DFG 21H Floor grille DFGL 21H Description DFG -21 H/V are multiparallel, horizontal or vertical fixed Bars in continuous modular sections. They are available in fixed pattern of air flow (Zero deflection) for supplying vertical air flow. Bars are of heavy duty type 6mm wide, and are equally spaced at(1/4 ) distance. Floor grille DFGL 21H Floor grille DFG 21H Mullion bars across the blades provide additional strength and extra special reinforcement in the structure of the grille to withstand loads up to 450 kg. Bars are fixed by a standard frame (1.5mm thickness). Special type heavy duty frames with 7mm thickness are also available forming an extra special heavy type of floor grilles. Both horizontal and vertical bar models can be supplied with apposed blade dampers and are called registers DFR-21 H/V. 16 Floor Grilles & Registers

MATERIAL & FINISH Frame blades and dampers are all of heavy gauge extruded aluminum sections in matt silver anodized finish. Blades are 6mm thickness, and standard frames are flat type extruded aluminum with 1.5 mm thickness sections. Special blades for heavy duty type floor grilles are available in 7mm thickness. DASCO floor grilles can be supplied in white polyester powder coating finish or any other specified RAL- standard colour upon your requirement. ORDERING CODE 1. DASCO FLOOR AIR GRILLES & REGISTERS ( Ordinary Light duty Type ) DFXL 21a - WxH X G R a H V WXH TYPE Grille Register (Grille with damper) Blade setting Horizontal Vertical Neck size, (inch) 2. DASCO FLOOR AIR GRILLES & REGISTERS ( Heavy duty Type ) DFX 21a - WxH X G R a H V WXH TYPE Grille Register (Grille with damper) Blade setting Horizontal Vertical Neck size, (inch) 17 Floor Grilles & Registers

BASIC PERFORMAE DATA SIZE W x H (inch) Area Factor ( Ft 2 ) Velocity (fpm) St. Pressure (Inch W.G) 400 500 600 700 800 1000 1200 1400 1600 0.01 0.016 0.025 0.039 0.052 0.093 0.134 0.178 0.218 12x6 0.25 CFM 104 132 160 188 216 272 328 384 440 <20 <20 <20 <20 <20 20 25 28 31 12x8 16x6 0.34 CFM 142 178 214 250 286 358 430 502 574 <20 <20 <20 <20 20 23 26 29 33 12x10 20x6 12x12 18x8 24x6 12x12 20x10 24x8 16x14 18x12 32x6 20x12 24x10 0.43 0.52 0.73 0.84 0.90 CFM 180 228 276 324 372 468 564 660 756 <20 <20 <20 <20 21 24 27 31 35 CFM 217 269 321 373 425 529 633 737 841 <20 <20 <20 <20 22 25 29 33 37 CFM 305 362 420 478 536 652 770 890 1051 <20 <20 <20 20 23 26 30 34 38 CFM 335 415 476 559 650 796 944 1090 1237 <20 <20 <20 21 24 27 31 35 39 CFM 378 453 540 631 736 904 1073 1241 1409 <20 <20 <20 22 26 29 32 36 40 24x12 24x10 20x18 30x12 36x10 1.10 1.45 CFM 450 567 648 756 881 1089 1296 1504 1712 <20 <20 <20 23 27 31 34 37 41 CFM 574 697 819 946 1104 1360 1615 1871 2127 <20 <20 <20 24 28 32 35 39 42 24x24 2.37 CFM 929 1107 1324 1521 1771 2195 2618 3040 3469 <20 <20 21 25 29 33 36 40 44 30x24 3.21 CFM 1180 1370 1656 1895 2194 2729 3228 3758 4288 <20 <20 22 26 30 34 38 41 45 36x24 4.03 CFM 1381 1631 1987 2265 2595 3230 3866 4500 5136 <20 <20 23 27 31 35 39 43 47 Table No. 9 - Floor Grille DFGL - 21H 18 Basic Performance Data

SIZE W x H (inch) Area Factor Velocity (fpm) ( Ft 2 ) St. Pressure (Inch W.G) 400 500 600 700 800 1000 1200 1400 1600 0.01 0.016 0.025 0.039 0.052 0.093 0.134 0.178 0.218 12x6 12x8 16x6 12x10 20x6 0.26 0.35 0.44 CFM 126 162 180 216 252 306 360 414 468 <20 <20 <20 <20 20 23 26 29 32 CFM 168 216 240 288 335 408 481 554 627 <20 <20 <20 <20 21 24 27 30 33 CFM 210 270 300 358 417 508 599 690 781 <20 <20 <20 <20 22 26 30 34 37 12x12 18x8 24x6 0.53 CFM 252 296 340 428 498 610 722 834 946 <20 <20 <20 20 23 27 31 35 38 16x12 20x10 24x8 0.75 CFM 351 442 510 590 686 840 994 1148 1302 <20 <20 <20 21 24 28 32 36 40 16x14 18x12 32x6 0.86 CFM 378 477 540 635 738 905 1072 1239 1406 <20 <20 <20 22 25 29 33 37 41 20x12 24x10 0.93 CFM 420 530 600 704 818 1005 1192 1379 1566 <20 <20 <20 23 26 30 34 38 42 24x12 36x8 1.12 CFM 504 630 720 840 979 1210 1441 1672 1903 <20 <20 20 24 28 32 36 39 43 20x18 30x12 36x10 1.48 CFM 630 766 900 1040 1213 1494 1775 2056 2337 <20 <20 21 25 29 33 37 40 45 24x24 2.41 CFM 1010 1203 1440 1654 1925 2385 2845 3305 3765 <20 <20 22 26 30 34 38 41 46 30x24 3.25 CFM 1283 1490 1800 2060 2384 2966 3548 4130 4712 <20 <20 23 27 31 35 39 42 47 36x24 4.09 CFM 1502 1773 2160 2462 2852 3550 4248 4946 5644 <20 <20 24 28 32 36 40 44 48 Table No. 10 - Floor Grille DFG - 21H 19 Basic Performance Data

PERFORMAE NOTES DEFINITIONS VELOCITY STATIC PRESSURE Ak Is discharge velocity measured at face of grille in (FPM). Noise criteria for the supply grille without damper with room effect of 8 db. Is in inches W.G. for supply grill without damper. Is area factor in Ft 2 CORRECTIONS ( Noise Criteria ) Add 2 db to the tabulated value in case of grille with damper. Add 4 db to the tabulated value for return grilles. Static Pressure For grille with damper, multiply the tabulated value by 1.4 For return grilles, multiply by 0.8 Floor Register DFRL 21H 20

CONVERSION TABLE Table No. 11 - Metric Guide Conversion Factors. Bar Grille DLBG 0º 21 Conversion Table

TESTING AND APPROVAL Different samples from DASCO air terminal devices (Linear Bar Grilles and Registers) were tested at ITS (Intertek Testing Services) labs in accordance with Air diffusion council test code for grilles, registers and diffusers No. ADC 1062 GRD-84. ISO 5219 Air distribution and air diffusion laboratory aerodynamic testing and rating of air terminal devices. ANSI/ASHRAE 70-1991, Method of testing for rating the performance of air outlets and inlets. LINEAR BAR GRILLES AND REGISTERS WERE TESTED FOR a. b. c. d. Sound ( Noise Criteria). Static pressure in inches W.G. Throw, feet. A k (Area factor). 22 Testing & Approval

COATING WITH POWDER NOW YOU CAN ACHIEVE OPTIMAL COATING PERFORMAE ON ALL PRODUCTS YOU PAINT! DASCO offers a first class service by introducing a wide range of perfect polyester powder coating on all of its aluminium products of air terminal devices. The best quality of polyester powder Corro-Coat are used in according to the internnational standards (BS,ISO,DIN,ASTM). PE-F architectural grade polyester powders are used perfectly with pre-treatment, electrostatic spray and curing in accordance with the above standards recommendations. A complete range of RAL-Standard colours are always available in addition to a vast range of special compound colours as per our customers request. RAL Standard Colour Chart Swatch 23

Now producing relief knots as in natural wood New Technology Excellence 1. 2. 3. Resistance to high radiation and extreme climatic conditions. It can be used in painting elaborate geometrical shapes producing perfect quality and aesthetic results. It is the only technology that can replace wood in traditional areas. New Mahogany - 21 New Mahogany - 22 24

25

Since 1962 P.O. Box 6192 Hawalli 32036 Kuwait. Tel +965 4839911 Fax +965 4815498 Product Bulletin 135-D