Ventilation grilles for installation into walls, sills or rectangular

Similar documents
Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling swirl diffusers

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate

For installation into ductwork

Pressure relief dampers

Ceiling swirl diffusers

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Slot diffusers for ceiling installation

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Type VSD35. Nominal length up to 1500 mm: one spigot

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Grilles Linear Grilles

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Grilles Linear Grilles

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Slot diffusers, Round duct diffusers. IMP Klima

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

WALL VENTILATION GRILLES CBP

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Air Displacement Vent Units

Active Chilled Beams

Wall and Ceiling Grille

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Active Chilled Beams

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Ceiling diffuser 4DF

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Linear Floor Grilles Models FG, F20, F25 and FRO

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Swirl Diffuser Model DQF

Duct Nozzle Diffuser. L e

Ceiling impulse diffuser Model PIL

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Ceiling diffuser 4DE

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

SDV Vane Swirl Diffusers

Ventilation grille Model AL

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

ceiling swirl diffuser DQJ

WGA Long throw nozzle grille

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Round duct diffuser DBB-RR

LINEAR SLOT DIFFUSERS

Ceiling Swirl Diffuser DQJ

KLIMA Active Chilled Beams

series Linear grilles

HIGH CAPACITY LINEAR SLOT DUFFUSERS

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Ceiling Slot Diffuser Model DSX

Round duct grille Model KG-RR

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Displacement flow diffusers. L e

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Catalog Swirl diffuser DAL 359

Compact Grille Model KG

PRODUCT BROCHURE. Adjustable Helical Swirl Diffuser HSC-AD HSC-AD : smartemp.com

INDEX. Chapter2. air master. Grilles and Registers

CONSTANTFLOW Volume Flow Controllers

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

CornerAir. CornerAir. Active chilled beam

series 90-GV Variable geometry units

Ceiling Slot Diffuser DSC

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Transcription:

X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades Nominal sizes 245 95 1245 445 mm Volume flow rate range 10 1235 l/s or 36 4446 m³/h Grille core made of aluminium with anodised finish Straight (0 ) or angled (15 ) air discharge PD 1

General information Type Page General information 2 Function 3 Technical data 6 Quick sizing 7 Specification text 8 Order code 9 Dimensions and weight 10 Product details 12 Basic information and nomenclature 13 Application Application Ventilation grille cores of Type as supply air or extract air variant for comfort zones and industrial zones Directed supply air discharge for mixed flow ventilation Blades for straight (0 ) or angled (15 ) air discharge to meet different local requirements For variable and constant volume flows For supply air to room air temperature differences from 12 to +4 K For covering all types of openings Special characteristics Fixed blades 0 or 15 air discharge Blade pitch 12.5 mm or 16.7 mm Nominal sizes Nominal length: 245, 345, 445, 545, 645, 845, 1045, 1245 mm Nominal height: 95, 145, 245, 345, 445 mm Other dimensions upon request Description Variants Blade pitch 12.5 mm G: Blade pitch 16.7 mm Blade construction style 0: 0 discharge 15: 15 discharge Parts and characteristics Fixed horizontal blades Two lateral mullions Vertical centre mullion (depending on length) Construction features Transverse bars for clip-fixing the grille (bars snap into clips) Materials and surfaces Blades made of aluminium Anodised blades, E6-C-0, natural colour P1: Blades powder-coated, RAL CLASSIC colour Standards and guidelines Sound power level of the air-regenerated noise measured according to EN ISO 5135 Maintenance Maintenance-free as construction and materials are not subject to wear Inspection and cleaning to VDI 6022 PD 2

Function Functional description Ventilation grilles are air terminal devices for the supply air and extract air of ventilation and air conditioning systems. They direct the supply air into the room. Ventilation grilles with adjustable blades allow for adapting the discharge direction to the local conditions. The result is a mixed flow ventilation in comfort zones and industrial zones, with good overall room ventilation. Induction slows the airflow down, i.e. the airflow velocity decreases as the distance from the grille increases. The distance at which the airflow velocity reaches a certain defined value, e.g. 0.2 m/s, is called throw distance. The supply air jet from wall grilles that are installed near the ceiling achieves a larger throw distance than a free jet (from a grille that is not installed near the ceiling). Single grilles, groups of grilles and continuous horizontal runs all achieve different throw distances. In cooling mode it is necessary to take account of the jet deviation towards the occupied zone, which increases as the supply air to room air temperature difference increases and the discharge velocity decreases. In heating mode the supply air jet deviates towards the ceiling. This has no negative effect on the airflow velocity in the occupied zone, but it may affect the complete ventilation of the room. Schematic illustration of a ventilation grille with longitudinal blades 1 3 2 1 Front border 2 Longitudinal blades 3 Centre mullion Air pattern in cooling mode, with ceiling effect, sectional view Air pattern in cooling mode, without ceiling effect, sectional view Distance from ceiling 0.3 m Distance from ceiling 0.8 m PD 3

Function Air pattern with ceiling effect, sectional view Air pattern without ceiling effect, sectional view ls ls Distance from ceiling 0.3 m Distance from ceiling 0.8 m Air pattern with ceiling effect, top view Air pattern without ceiling effect, top view ls ls Air pattern with ceiling effect, group of grilles, top view Air pattern without ceiling effect, group of grilles, top view ls ls Distance between single grilles 0.15 l S Distance between single grilles 0.2 l S PD 4

Function Air pattern, group of grilles, top view b b < 0.1 l S Several single grilles arranged in a row and with not much distance between them have the same effect as a continuous horizontal run. PD 5

Technical data Nominal sizes Minimum volume flow rate Maximum volume flow rate, with L WA max. 40 db(a) without attachments Supply air to room air temperature difference Volume flow rates apply to supply air 245 95 to 1245 445 mm 10 410 l/s or 36 1476 m³/h 55 1235 l/s or 198 4446 m³/h 12 to +4 K, geometric free area L [mm] 245 345 445 545 645 845 1045 1245 A geo mm m² 95 0.015 0.021 0.028 0.034 0.040 0.052 0.064 0.076 145 0.022 0.031 0.040 0.049 0.058 0.075 0.093 0.111 245 0.050 0.065 0.080 0.094 0.121 0.151 0.180 345 0.090 0.110 0.130 0.168 0.208 0.249 445 0.166 0.215 0.266 0.318 -G, geometric free area L [mm] 245 345 445 545 645 845 1045 1245 A geo mm m² 95 0.018 0.025 0.033 0.040 0.047 0.061 0.076 0.090 145 0.026 0.037 0.047 0.058 0.069 0.089 0.110 0.131 245 0.060 0.077 0.095 0.112 0.145 0.179 0.214 345 0.107 0.131 0.155 0.201 0.249 0.297 445 0.198 0.256 0.318 0.379 PD 6

Quick sizing, volume flow rate ranges 1225 425 1025 425 825 425 625 425 1225 325 1025 325 825 325 625 325 525 325 425 325 1225 225 1025 225 825 225 625 225 525 225 425 225 325 225 1225 125 1025 125 825 125 625 125 525 125 425 125 325 125 225 125 1225 75 1025 75 825 75 625 75 525 75 425 75 325 75 225 75 Nenngröße 35 40 50 100 200 500 1000 2000 5000 8000 m 3 /h 10 20 50 100 200 500 1000 2000 2400 l/s L WA = 40 db(a) with unrestricted airflow+ L WA = 40 db(a) with airflow restricted by 50 % PD 7

Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Ventilation grille cores, rectangular, made of aluminium, for supply and extract air. Ready-to-install component which consists of fixed horizontal blades, two lateral mullions, and possibly a vertical centre mullion (depending on length). Preferably for installation into an installation subframe provided by others. Sound power level of the air-regenerated noise measured according to EN ISO 5135. Special characteristics Fixed blades 0 or 15 air discharge Blade pitch 12.5 mm or 16.7 mm Materials and surfaces Blades made of aluminium Anodised blades, E6-C-0, natural colour P1: Blades powder-coated, RAL CLASSIC colour Technical data Nominal sizes: 245 95 to 1245 445 mm Minimum volume flow rate (supply air): 10 410 l/s or 36 1476 m³/h Maximum volume flow rate (supply air), at L WA max. 40 db(a) without attachments: 55 1235 l/s or 198 4446 m³/h Supply air to room air temperature difference: 12 to +4 K Sizing data [m³/h] Δp t [Pa] Air-regenerated noise L WA [db(a)] PD 8

Order code G 0 / 845 245 / P1 RAL... Type Grille core Blade pitch No entry: 12.5 mm G 16.7 mm Blade construction style 0 0 blades (straight) 15 15 blades (angled) Exposed surface No entry: anodised, E6-C-0, natural colour P1 Powder-coated, specify RAL CLASSIC colour Gloss level RAL 9010 50 % RAL 9006 30 % All other RAL colours 70 % Nominal size [mm] L Order example: -G-0/645 245 Blade pitch 16.7 mm Blade construction style 0 Nominal size 645 245 mm Exposed surface Anodised, E6-C-0, natural colour PD 9

Dimensions and weight The weight table shows the available nominal sizes -0 12,5 L 10,5 L Nominal length Vertical centre mullion if L > 625 mm Nominal height -15 12,5 L 10,5 L Nominal length Vertical centre mullion if L > 625 mm Nominal height mm L [mm] 245 345 445 545 645 845 1045 1245 95 0.3 0.5 0.6 0.7 0.9 1.2 1.4 1.7 145 0.5 0.7 1.0 1.2 1.4 1.8 2.3 2.7 245 0.9 1.3 1.7 2.0 2.4 3.1 3.9 4.6 345 1.3 1.8 2.4 2.9 3.4 4.5 5.5 6.6 445 1.7 2.4 3.1 3.7 4.4 5.8 7.2 8.5 m kg PD 10

Dimensions and weight -G-0 16,7 L 10,5 L Nominal length Vertical centre mullion if L > 625 mm Nominal height -G-15 16,7 L 10,5 L Nominal length Vertical centre mullion if L > 625 mm Nominal height -G mm L [mm] 245 345 445 545 645 845 1045 1245 95 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.2 145 0.4 0.5 0.7 0.9 1.0 1.3 1.6 2.0 245 0.7 0.9 1.2 1.5 1.8 2.3 2.9 3.4 345 1.0 1.4 1.7 2.1 2.5 3.3 4.1 4.9 445 1.2 1.8 2.3 2.8 3.3 4.3 5.3 6.3 m kg PD 11

Product details Blade *-0 5,5 18 Blade *-15 5,5 18 PD 12

Basic information and nomenclature Principal dimensions L [mm] Nominal length of the ventilation grille Nominal height of the ventilation grille m [kg] Weight [mm] Nomenclature L WA [db(a)] Sound power level of the air-regenerated noise [m³/h] and [l/s] Volume flow rate Δp t [Pa] Total differential pressure l S [m] Distance from single grille or horizontal run section (throw distance) PD 13