Electronic overload relays EF205 and EF370

Similar documents
Electronic overload relay EF65, EF96 and EF146

Thermal overload relay TF65 and TF96

Thermal overload relay TF140DU and TF140DU-V1000

Manual motor starter MS116

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter magnetic only MO325

Manual motor starter MS116

Manual motor starter MS132

Mini contactors B6, BC6 with 3 pole

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Thermal Overload Relays

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors Technical data

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Manual motor starters Overview and benefits

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MS General Information Extended Product Type: MS

Selective main circuit breakers S 750 series Technical Data

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Short form catalogue. Motor protection & control

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

ABB i-bus KNX DG/S x DALI-Gateway Basic

ASL09..S 3-pole Contactors - Spring Terminals

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

DBL distribution blocks 3x1 pole

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

E16DU, E45DU, E80DU, E140DU electronic overload relays 0.10 to 140 A

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Short form catalogue Motor protection and control Manual motor starters

ZS50-PE Screw Clamp Terminal Blocks Ground

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

TA25DU0.4 Overload Relay a. Features. Descriptions

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

SIRIUS 3RU2 Thermal Overload Relays

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS10 Screw Clamp Terminal Blocks Feed-through

Star Series Motor protection & control

ZS4 Screw Clamp Terminal Blocks Feed-through

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

B Mini Contactor V Hz

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Overloadrelay,10-16A,1N/O+1N/C. Articleno

DEVICE STATE/BYPASSED FAILURE OVERLOAD

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

Solid State Relays, 3-phase

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Data Sheet Manual Motor Starters Ex9SN Series

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Mini Contactors Applications and Segments

Panorama. Contactors Motor protection Accessories

Protection Equipment

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

CI-TI Contactors and motor starters Types CI 61 - CI 98

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

Transcription:

Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor starters are combinations of overload relays and contactors. 2CDC231012V0013 2CDC231008V0013 Description Overload protection trip class 10E, 20E, 30E selectable Phase loss sensitivity Temperature compensation from -25 +70 C Adjustable current setting for overload protection Automatic or manual reset selectable Trip-free mechanism Status indication STOP and TEST function Direct mounting onto block contactors Sealable operating elements Self-supplied devices Order data screw terminal For A145 AF370 block contactors Setting range A Type Order code Suitable for Packing unit PCE Weight per PCE kg 63... 210 EF205-210 1SAX531001R1101 A145, A185, AF145, AF185, AF190, AF205 1 1.210 115... 380 EF370-380 1SAX611001R1101 A210, A260, A300, AF210, AF260, AF265, AF300, AF305, AF370 1 1.430 Suitable for mounting on: A145, A185, AF145, AF185, AF190, AF205 A210, A260, A300, AF210, AF260, AF265, AF300, AF305, AF370

Functional description 1 Terminals 1L1, 3L2, 5L3 1 2 Sealable operating elements 3 Trip class 10E, 20E, 30E selectable 4 RESET - Automatic or manual reset selectable 5 TEST - Status indication 2CDC232018F0013 2 3 4 5 6 7 8 9 10 6 Signaling contacts 97-98 7 Terminals 2T1, 4T2, 6T3 8 STOP 9 Current setting range / Self-test function ST Adjustable current setting for overload protection 10 Tripping contacts 95-96 Application / internal function The self-supplied electronic overload relays are three pole electronic/mechanical devices. The motor current flows through build-in current transformers and an evaluation circuit will recognize an overload (over current). This will lead to a release of the relay and a change of the contacts switching position (95-96 / 97-98). The contact 95-96 is used to control the load contactor. The electronic overload relay is self-supplied, which mean no extra external supply is needed. The overload relays have a setting scale in Amperes, which allows the direct adjusting of the relay without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current). The relays are constructed in a way that they protect themselves in the event of an overload. The overload relay has to be protected against short-circuit. The appropriate short-circuit protective devices are shown in the following tables. To prevent thermal overloads in heavy duty applications, the correct cable sizes have to be selected. Operation mode 1~ 3~ 50/60 Hz 2CDC232013F0012 2CDC232005F0013 Contact 95-96 Contact 97-98 Opto-mechanical slide Comment Trip state open closed RESET state closed open ON TEST manual reset mode open closed TEST auto reset mode open closed STOP while device is in trip state open closed STOP button has no function STOP while device is in RESET state open open while STOP button is pressed 2-2CDC107025D0201

Wiring diagram RESET Auto Man 95 97 2CDC232001F0011 2T1 4T2 6T3 TEST STOP 96 98 2CDC232001F0011 Resistance and power loss per pole and short-circuit protective devices Type Setting range Resistance per pole Power loss per pole Short-circuit protective devices coordination type 2 lower value A upper value A mω at lower value W at upper value W EF205-210 63 210 0.027 0.107 1.191 Fuse 1250 A, Type gg EF370-380 115 380 0.028 0.370 4.043 Fuse 1600 A, Type gg Intermittent periodic duty switching frequency (Op/h) 160 140 120 100 80 60 40 20 t = 0.5 s a t a = 1 s t a = 1.5 s t a = 3 s t a = 5 s Trip class 10E 0 0 20 40 60 80 100 (%) duty ratio 2CDC232001F0214 switching frequency (Op/h) 80 70 60 50 40 30 20 10 t = 2 s a t a = 4 s t a = 8 s t a = 10 s t a = 12 s t a = 6 s Trip class 20E 0 0 20 40 60 80 100 (%) duty ratio 2CDC232002F0214 switching frequency (Op/h) 50 45 40 35 30 25 20 15 10 5 t = 5 s a t a = 10 s t a = 15 s t a = 20 s t a = 25 s Trip class 30E 0 0 20 40 60 80 100 (%) duty ratio 2CDC232003F0214 Trip class 10E Trip class 20E Trip class 30E 2CDC107025D0201-3

Dimensions 122.8 4.83" 105 4.13" 7.4 0.29" 17.9 0.7" 5 0.2" 0.43" 18.5 11 4.8" 122 151 5.9" 10 0.39" 116.5 4.59" 30 1.18" 5 0.2" 0.73" Ø 8.5 Ø 0.33" 35 1.38" 17.5 0.69" 35 1.38" 0.39" 10 35 1.38" 5 0.2" 121.7 4.79" 2CDC232004F0012 EF205-210 122.8 4.83" 105 4.13" 116.5 4.59" 22.8 0.9" 93.8 3.69" 7.4 0.29" Ø 11 Ø 0.43" 43.8 1.72" 17.9 0.7" 20 0.79" 43.8 1.72" 5 0.2" 11 0.43" 122 0.4' 14 0.55" 163.6 6.4" 10 0.39" 30 1.18" 5 0.2" 35 1.38" 5 0.2" 121.7 4.79" 2CDC232005F0012 EF370-380 4-2CDC107025D0201

Technical data IEC/EN Data at T A = 40 C and at rated values, if nothing else indicated Main circuit Rated operational voltage U e 1000 V AC - V DC Setting range - electronic overload protection see table on page 1 Rated operational current AC-3 I e see upper value of setting range, table on page 3 Trip class 10E, 20E, 30E, selectable Rated frequency 50/60 Hz Number of poles 3 Resistance per pole see table on page 3 Power loss per pole see table on page 3 Short-circuit protective devices see table on page 3 Isolation data Rated impulse withstand voltage U imp 8 kv Rated insulation voltage U i 1000 V Pollution degree 3 Overvoltage category up to III Electrical connection EF205 EF370 Connecting capacity rigid with cable lug 16... 185 mm² 16... 120 mm² 50... 240 mm² 50... 150 mm² flexible with cable lug 16... 185 mm² 16... 120 mm² 50... 240 mm² 50... 150 mm² Stripping length - - Tightening torque 18 Nm 28 Nm Screw type M8 M10 Lug/Bar L 24 mm 32 mm Ø > 8 mm 10 mm 2CDC107025D0201-5

Auxiliary circuit Rated operational voltage U e Conventional free air thermal current I th Rated frequency Number of poles 600 V AC / DC 6 A DC, 50/60 Hz 1NC + 1NO Rated operational current I e acc. to IEC/EN 60947-5-1 for utilization category at AC-15 at 110-120 V NC, 95-96 3.00 A 3.00 A at AC-15 at 220-230-240 V NC, 95-96 3.00 A 3.00 A at AC-15 at 400 V NC, 95-96 1.10 A 1.10 A at AC-15 at 480-500 V NC, 95-96 0.75 A 0.75 A at DC-13 at 24 V NC, 95-96 1.50 A 1.50 A at DC-13 at 60 V NC, 95-96 0.55 A 0.55 A at DC-13 at 110-120-125 V NC, 95-96 0.55 A 0.55 A at DC-13 at 250 V NC, 95-96 0.27 A Minimum switching capacity Short-circuit protective devices 0.27 A 12 V / 3 ma l = 10-7 ; U kd = 3 V / 500.000 operating cycles fuse 6 A, Type gg Isolation data Rated impulse withstand voltage U imp 6 kv Rated insulation voltage U i 690 V Pollution degree 3 Overvoltage category up to III Electrical connection Connecting capacity rigid 1... 4 mm² 1... 4 mm² flexible with ferrule flexible with insulated ferrule flexible Stripping length 9 mm Tightening torque 0.8... 1.2 Nm Recommended screw driver Pozidriv 2 6-2CDC107025D0201

General data Duty time 100 % Operating frequency without early tripping see diagrams on page 3 Dimensions (W x H x D) see dimension drawing Weight see ordering data Mounting screw with two screws on plate and tighten the screws of the main circuit terminals Mounting on plate M5 2 Nm / 18 lb.in Mounting position optional, position 1-6 Minimum distance to other units same type horizontal none vertical not applicable Minimum distance to electrical conductive board horizontal 1.5 mm vertical 1.5 mm Degree of protection housing IP20 main circuit terminals IP10 Maximum operating altitude 2000 m Electromagnetic compatibility Immunity acc. to IEC 60947-1 Emission acc. to IEC 60947-1 Environment A Environment B Environmental data Ambient air temperature Operation open - compensated -25... +70 C open -25... +70 C Storage -50... +85 C Ambient air temperature compensation acc. to IEC/EN 60947-4-1 Resistance to vibrations acc. to IEC 60068-2-6 5g / 3... 150 Hz Resistance to shock acc. to IEC 60068-2-27 25g / 11 ms Standards / directives Standards IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC 2CDC107025D0201-7

Technical data UL/CSA Full load amps and short-circuit protective devices Type Full load Short circuit protective devices amps 480 V AC 600 V AC 600 V AC 600 V AC (FLA) SCCR Circuit breaker SCCR Fuse K5 / RK5 Circuit breaker SCCR Fuse J SCCR Circuit breaker EF205-210 210 A 100 ka 400 A 10 ka 400 A 400 A 100 ka 400 A 100 ka 400 A EF370-380 380 A 100 ka 800 A 18 ka 800 L/T 800 A 100 ka 600 A 100 ka 600 A Main circuit Maximum operational voltage Trip rating Full load amps (FLA) Short-circuit rating RMS symmetrical Short-circuit protective devices 600 V AC 125 % of FLA see table above see table above see table above Electrical connection EF205 EF370 Connecting capacity stranded with cable lug AWG 6... 0000 AWG 6... 0000 AWG 1... 500 kcmil AWG 1... 500 kcmil flexible with cable lug 6... 0000 6... 0000 AWG 1... 500 kcmil AWG 1... 500 kcmil Lug/Bar L 24 mm 32 mm Ø > 8 mm 10 mm Stripping length - - Tightening torque 160 lb.in 247 lb.in Screw type M8 M10 Auxiliary circuit Conventional thermal current 6 A Making and breaking capacity NC / NO B600, Q600 Electrical connection Connecting capacity stranded AWG 18... 10 AWG 18... 10 flexible AWG 18... 10 AWG 18... 10 Stripping length 9 mm Tightening torque 7... 11 lb.in Recommended screw driver Pozidriv 2 8-2CDC107025D0201

Contact us ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Brochure number 2CDC 107 042 D0201 (08.2014) Copyright 2014 ABB All rights reserved