AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Similar documents
Magnetic Overload Relays

AC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:

Overload Relay Heater Tables

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

SECTION MOTOR CONTROL

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Table of Contents. HCC Contactor Nomenclature

A200 NEMA Contactors and Starters A200

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

NMC Combination Line Starters and Enclosures

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

Contactors & Starters Index

MAGNETIC MOTOR STARTERS

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

C E R T I F I C A T E O F C O M P L I A N C E

MOTOR TERMINAL CONNECTIONS

KT4 Manual Motor Starter

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Ideal for use as a manual starter

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

AF series contactors (9 2650)

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Enclosed Molded Case Circuit Breakers

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

AF series contactors (9 2650)

Definite Purpose Contactors and Starters

EBMC Combination Line Starters and Enclosures

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Motor Protection. Presented By. Scott Peele PE

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

ACS motor protection circuit breakers KT 7 Introduction

Definite Purpose Contactors and Starters

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

AP/UP, AP/MIL Series Magnetic Circuit Protectors

3. Coils shall be of molded construction

Multi-Pak Group Control

ECET 211 Electric Machines & Controls Lecture 2-3 (Part 3 of 3) Symbols and Drawing for Electric Motor Control Systems

NEMA Control. Contactors & Starters Index

Technical Information

Industrial Control Transformers

209 Series. Magnetic Circuit Protectors

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Certi 堵脝 cation Record

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

CI-TI Contactors and motor starters Types CI 61 - CI 98

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

SECTION MOTOR CONTROLLERS

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

IEC Utilization Categories (Explanation)

MERCURY CONTACTORS & RELAYS

General Purpose Relay

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Crane Control Class 9055

TA Ta VA CTRL-XFRMR

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

NEMA Contactors & Starters (Freedom)

Technical Information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

UMBW-UL489 and UL1077 Listed

DETAIL SPECIFICATION SHEET

Electropneumatic Timing Relays Series 7000 Industrial

Horizontal Circuit Switchers

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Horizontal Circuit Switchers

TYPE LS-K CONTACTORS TECHNICAL SPECIFICATIONS

Definite Purpose Contactors and Starters

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Definite Purpose Contactors and Starters

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Enclosures. See Section Typical Description

KT4 Manual Motor Starters

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

209/219/229/249/279 Series Magnetic Circuit Protectors

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

and Refrigeration Institute). CNX Special Purpose Contactors

Vacuum Contactors and Starters

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Submittal Data Information

Stearns Heavy Duty Clutches & Brakes... Rugged, Reliable

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Typical UL1077 Application

Crane Control Class 5010

SECTION MOTOR CONTROLLERS

Transcription:

AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification Application Forms Contacts Rated Ambient Duty MIL-C-2212 Auxiliary relay, control relay, or undervoltage relay. Select standard form (IC5182), or quiet form (IC5182D) when control is to meet standard MIL-STD-740. All quiet AC relays undergo special testing at the factory. Available in 2, 4, 6, and 8 contact versions. 50 o C Continuous Insulation Class B (coil is Class A) Type IC5182 AC Relay Basic Catalog Number IC5182 Standard Quiet Number of 115 V 440 V 115 V 440 V Contacts Coil Coil Coil Coil 2 C120A3 C120A6 D120A3 D120A6 4 C120A3 C120A6 D120A3 D120A6 6 C120A3 C120A6 D120A3 D120A6 8 C120A3 C120A6 D120A3 D120A6 Ordering Information Order by complete catalog number. Complete catalog number consists of the basic catalog number, plus a contact arrangement indicator. Example: A standard relay having a 440 VAC, 60 Hz coil and 6 N.O. and 2 N.C. contacts is: IC5182C120A6ABBA Basic Catalog Number Contact Arrangement Indicator Unlisted Ratings: For other unlisted voltages or frequencies or for application on D.C., refer to Company. Control Power Requirements Volts Amperes Holding Amperes Inrush 115 0.33 2.1 440.08 0.5 Contact Ratings (Amperes) Break Volts One 2 Contacts Carry Make Contact in Series 115 VAC 10 60 10-440 VAC 10 60 5-115 VDC Inductive 10 60 1 2 Noninductive 10 60 5 10 230 VDC Inductive 10 60 0.5 1 Noninductive 10 60 2 4

AC Relays Type IC5182 Outline and Mounting Dimensions Contact Arrangements Contact No. of Auxiliary Arrangements Arrangement Contacts N.O. N.C. Indicator 2 0 XBXX 2 1 1 XAXX 0 2 XCXX 0 4 XCCX 1 3 XACX 4 2 2 XAAX 3 1 XABX 4 0 XBBX 6 0 BBBX 5 1 ABBX 6 4 2 ABAX 3 3 AAAX 2 4 ACAX 8 0 BBBB 7 1 ABBB 8 6 2 ABBA 5 3 AABA 4 4 AAAA

Thermal Overload Relays Series N154 Type N154 Relay is an ambient compensated single pole inverse time thermal overload relay suitable for A.C. or D.C. service. It is specifically designed for use with motor starters and controllers that are to be applied on Navy Service A applications. Specification Function Operation Type Heaters Compensation Insulation Adjustment Voltage Contact Rating MIL-C-2212 Motor overload protection Thermal inverse time delay type, manual reset Series N154 Interchangeable, Heaters available with current trip range 0.36 to 275 amps. Ambient compensation within 0.3% per degree change in ambient temperature between 20 oc and 70 oc. Class A Trip current adjustable +/- 10% of heater rating. A.C. 600 volts max., D.C. 250 volts max. Normally closed contact will carry and break 6 amps. max. A.C. and 200 V.A. with a max. of 2 amps. D.C. Series N154 Thermal Overload Relay Dimensions (Approximate) Use with Ampere Rating Catalog Contactor Size Nominal Number 0, 1 25 N154-1 2 50 N154-2 3 100 N154-3 4 150 N154-4 5 300 N154-5* * Relays must be used with current transformer. Consult Factory for transformer selection. Ordering Information When ordering Series N154 Overload Relays, specify: 1. Catalog Number 2. Motor type, H.P. and nameplate amperes. When ordering heaters, specify Heater Part Number and Motor Full Load Amperes. Heaters furnished separately. Repair Parts Repair parts are normally furnished in accordance with the applicable part allowance list include: 1 set of overload heaters (wt. 2 oz. each)

Thermal Overload Relays Series N154 Heaters Full Load Motor Amperes Heater Marking Catalog Number.28 -.30.36 104.813.11.31 -.34.40 104.813.12.35 -.39.45 104.813.13.40 -.44.51 104.813.14.45 -.50.58 104.813.15.51 -.56.65 104.813.16.57 -.64.73 104.813.17.65 -.73.83 104.813.18.74 -.30.94 104.813.19.82 -.92 1.06 104.813.20.93-1.05 1.20 104.813.21 1.06-1.19 1.36 104.813.22 1.20-1.35 1.54 104.813.23 1.36-1.53 1.74 104.813.24 1.54-1.73 1.95 104.813.25 1.74-1.94 2.21 104.813.26 1.95-2.1 2.50 104.813.27 2.2-2.5 2.83 104.813.28 2.6-2.8 3.20 104.813.29 2.9-3.2 3.65 104.813.30 3.3 -.3.6 4.15 104.813.31 3.7-4.0 4.65 104.813.32 4.1-4.5 5.25 104.813.33 4.6-5.3 5.95 104.813.34 5.4-6.0 6.75 104.813.35 6.1-6.7 7.70 104.813.36 6.8-7.7 8.70 104.813.37 7.8-9.0 10.2 104.813.38 9.1-10.3 11.7 104.813.39 10.4-11.7 13.2 104.813.40 11.8-13.0 14.8 104.813.41 Full Load Motor Amperes Heater Marking Catalog Number 13.1-14.0 16.0 104.813.42 14.1-16.0 18.0 104.813.43 16.1-18.0 20.5 104.813.44 18.1-20.3 23.0 104.813.45 20.4-22.9 26.0 104.813.46 23.0-25.4 29.5 104.813.47 25.5-27.0 32.0 104.813.48 28-31 35.0 104.813.49 32-35 41.0 104.813.50 36-38 44.0 104.813.51 39-42 49.0 104.813.52 43-45 53.0 104.813.53 46-48 58.0 104.813.54 49-52 62.0 104.813.55 53-57 67.0 104.813.56 58-63 73.0 104.813.57 64-71 81.0 104.813.58 72-80 91.0 104.813.59 81-89 102.0 104.813.60 90-98 113.0 104.813.61 99 -.108 123.0 104.813.62 109-118 137.0 104.813.63 119-125 149.0 104.813.64 126-136 157.0 104.813.65 137-151 173.0 104.813.66 152-163 190.0 104.813.67 164-180 205.0 104.813.68 181-190 223.0 104.813.69 191-199 244.0 104.813.70 200-205 275.0 104.813.71

Thermal Overload Relays Type IC5882D Specification Application Type Form Voltage MIL-C-2212 Use for motor overload protection. Heater type with interchangeable heater elements and adjustable trip setting. Trip current can be varied +/- 10% from factory setting. Dual element (two pole) with one N.C. contact. Use only one pole for single phase A.C. or D.C. 600 volts maximum. Type IC5882D Overload Relay Outline and Mounting Dimensions (in inches) Ordering Information To order overload relay with heaters specify overload relay catalog number and heater catalog number. Example: IC5882D122B with two Type 81D363 heaters. Overload relay or heaters may be ordered as separate items (not assembled together) by specifying appropriate catalog number and quantity of each required. Contact Ratings (Amperes) Carry Make Break Continuous Momentary 115 VAC 440 VAC 115 VDC 230 VDC 10 30 15 5 0.35 0.17

Thermal Overload Relays Type IC5882D Heaters Use With Reset Rod Catalog Number Contactor Size Length 0, 1 Short IC5882D121A Long IC5882D121B 2 Short IC5882D122A Long IC5882D122B 3 Short IC5882D123A Long IC5882D123B 4, 5, 6* *Size 4: USE induction overload relay on page 26 Size 5 & 6: USE overload relay Cat. No. IC5882D121 with two 200:5 current transformers.

Thermal Overload Relays Type IC5882D Heaters Max. Cont. Full Load Motor Amp Heater Rating for 40º C Rise Motors Amps @ 40º C Catalog Number Max. Cont. Full Load Motor Amp Heater Rating for 40º C Rise Motors Amps @ 40º C Catalog Number Size 0, 1, 2 Size 0, 1, 2 0.37-0.38 0.44 81D303 0.39-0.42 0.48 81D304 0.43-0.46 0.53 81D305 0.47-0.50 0.58 81D306 0.51-0.56 0.64 81D307 0.57-0.62 0.71 81D308 0.63-0.67 0.77 81D309 0.68-0.74 0.85 81D310 0.75-0.82 0.94 81D311 0.83-0.90 1.03 81D312 0.91-0.99 1.14 81D313 1.00-1.09 1.25 81D314 1.10-1.20 1.37 81D315 1.21-1.31 1.50 81D316 1.32-1.44 1.65 81D317 1.45-1.59 1.82 81D318 1.60-1.74 2.00 81D319 1.75-1.92 2.20 81D320 1.93-2.11 2.42 81D321 2.12-2.31 2.65 81D322 2.32-2.55 2.92 81D323 2.56-2.80 3.20 81D324 2.81-3.09 3.54 81D325 3.10-3.42 3.92 81D326 3.43-3.75 4.3 81D327 3.76-4.10 4.7 81D328 4.11-4.54 5.2 81D329 4.55-4.98 5.7 81D330 4.99-5.45 6.25 81D331 5.46-6.03 6.9 81D332 6.04-6.65 7.6 81D333 6.66-7.25 8.3 81D334 7.26-8.05 9.2 81D335 8.06-8.83 10.1 81D336 8.84-9.70 11.1 81D337 9.71-10.6 12.2 81D338 10.7-11.7 13.4 81D339 11.8-12.7 14.5 81D340 12.8-13.9 15.9 81D341 14.0-15.2 17.4 81D342 15.3-16.8 19.3 81D343 16.9-18.5 21.3 81D344 18.6-20.6 23.6 81D345 20.7-22.5 25.9 81D346 22.6-24.9 28.5 81D360 25.0-27.3 31.3 81D361 27.4-30.0 34.5 81D362 30.1-33.0 37.9 81D363 33.1-36.4 41.9 81D364 36.5-44.0 46.0 81D365 40.1-44.2 50.6 81D366 Size 3 22.6-24.9 28.5 81D400 25.0-27.3 31.3 81D401 27.4-30.0 34.5 81D402 30.1-33.0 37.9 81D403 33.1-36.4 41.7 81D404 36.5-40.0 46.0 81D405 40.1-44.2 50.6 81D406 44.3-48.6 55.7 81D407 48.7-53.6 61.3 81D408 53.7-58.8 67.4 81D409 58.9-64.7 74.1 81D410 64.8-71.1 81.5 81D411 71.2-78.3 89.7 81D412 78.4-86.0 98.6 81D413 86.1-94.0 108 81D414 94.1-103.0 119 81D415 Note: Ultimate trip current will be 90%-100% of heater rating.

Thermal Overload Relays Induction Type IC5882-34 Specification Application Type Form Reset Voltage MIL-C-2212 Use for overload protection of A.C. motors where highly accurate, ambient compensated overload relays are required. Choose medium-trip relay for most applications. Use slowtrip relay if it is necessary to have motor ride through long over load periods. Use fast-trip relay for motors that heat rapidly. See characteristic curves for comparative time-current characteristics. Induction type with interchangeable coils and adjustable trip setting. Trip current can be varied +/- 10% from factory setting. Compensation is such that trip current will not vary more than 3 percent for each 10 o C change in ambient temperature. Single element (one pole) with one N.C. contact. Use two relays in two lines of a three phase circuit. Reset manually with one reset button or electrically with reset relay on page 32 600 volts maximum. Ordering Information To order overload relay with heating coil, specify overload relay catalog number with heating coil suffix number. Contact Ratings Amperes Break Example: IC5882-34JJ200 To order overload relay only (less coil) specify overload relay catalog number only. Carry Make 115 VAC 440 VAC 10 30 20 5 Example: IC5882-34JJ To order heating coil only specify heating coil catalog number plus suffix number. Example: 1D5G200 Type of Trip Slow Medium Fast Overload Relay Catalog Number IC5882-34KK IC5882-34JJ IC5882-34MM

Thermal Overload Relays Induction Type IC5882-34 Heaters Coils (Sizes 0-4) Max. Cont. Coil Catalog Number is ID5G Full Load Plus Suffix Listed Below Motor Amp Coil Medium-trip Slow-trip Fast-trip for 40º C Rating IC5882-34JJ IC5882-34KK IC5882-34MM Rise Motors 0.57-0.62 in Amps 0.71 200 Coil Suffix 200 0.57-0.62 0.71 200 200 0.63-0.69 0.78 201 201 200 0.70-0.76 0.86 202 202 201 0.77-0.82 0.94 203 203 202 0.83-0.91 1.03 204 204 203 0.92-1.00 1.13 205 205 204 1.01-1.10 1.24 206 206 205 1.11-1.20 1.36 207 207 206 1.21-1.33 1.50 208 208 207 1.34-1.45 1.65 209 209 208 1.46-1.60 1.80 210 210 209 1.61-1.77 2.00 211 211 210 1.78-1.94 2.20 212 212 211 1.95-2.13 2.42 213 213 212 2.14-2.33 2.65 214 214 213 2.34-2.58 2.92 215 215 214 2.59-2.82 3.22 216 216 215 2.83-3.10 3.52 217 217 216 3.11-3.40 3.87 218 218 217 3.41-3.74 4.25 219 219 218 3.75-4.12 4.68 220 220 219 4.13-4.54 5.15 221 221 220 4.55-4.94 5.65 222 222 221 4.95-5.48 6.20 223 223 222 5.49-6.03 6.85 224 224 223 6.04-6.66 7.55 225 225 224 6.67-7.32 8.34 226 226 225 7.33-8.03 9.16 227 227 226 8.04-8.83 10.0 228 228 227 8.84-9.70 11.1 229 229 228 9.71-10.8 12.2 230 230 229 10.9-11.9 13.5 231 231 230 12.0-13.0 14.9 232 232 231 13.1-14.2 16.1 233 233 232 14.3-15.7 17.8 234 234 233 15.8-17.1 19.6 235 235 234 17.2-18.2 21.7 236 236 235 Max. Cont. Full Load Coil Catalog Number is ID5G Plus Suffix Listed Below Motor Amp Coil Medium-trip Slow-trip Fast-trip for 40º C Rating IC5882-34JJ IC5882-34KK IC5882-34MM Rise Motors 0.57-0.62 in Amps 0.71 200 Coil Suffix 200 18.3-20.0 22.9 237 237 236 20.1-22.0 25 238 238 237 22.1-24.4 27.5 239 239 238 24.5-26.1 29.5 240 240 * 26.2-27.1 30.6 * * 239 27.2-27.4 31.2 241 241 * 27.5-28.7 32.4 * * 240 28.8-29.4 33.3 242 242 * 29.5-30.4 34.4 * * 241 30.5-31.4 35.7 243 243 * 31.5-32.5 36.7 * * 242 32.6-33.9 38.5 244 244 * 34.0-34.8 39.3 * * 243 34.9-35.9 41.7 245 245 * 36.0-38.4 43.3 * * 244 38.5-40.3 45.5 246 246 * 40.4-40.6 45.8 * * 245 40.7-44.1 50 247 247 246 44.2-49.0 55 248 248 247 49.1-53.7 61 * * 248 53.8-55.3 62.5 249 249 * 55.4-60.5 68.8 253 253 * 60.6-60.8 69 * * 249 60.9-63.0 71.5 250 250 * 63.1-63.9 72.5 * * 253 64.0-69.5 78.7 254 254 * 69.6-69.6 79 * * 250 69.7-73.1 83 * * 254 73.2-74.0 83.5 251 251 * 74.1-81.0 92 255 255 251 81.1-85.0 96.6 * * 255 85.1-88.2 100 252 252 * 88.3-96.9 110 * * 252 97-98 110 256 256 * 99-106.5 121 * * 269 106.6-111 125 64 64 * 112-121 137 85 85 64 122-127 144 * * 85 128-133 150 272 272 * NOTE: Ultimate trip current will be 90-100% of coil rating. * Use next higher rating

Thermal Overload Relays Characteristic Curves Induction Type IC5882-34 Outline and Mounting Dimensions (In Inches) Wiring Symbol

Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification Function Operation Compensation Adjustment Insulation Voltage MIL-R-2033 Motor overload protection. Magnetic inverse time delay type, self reset. Ambient compensated between 20 o C and 70 o C Trip current adjustable +/- 10% of nominal current rating. Class A Normally closed contact will carry and break 5 amps 440 volts max. A.C. and 1 amp D.C N147 Magnetic Overload Relay Ordering Information When ordering N147 Magnetic Overload Relays, the following information is requested: 1. Series No. of relay Repair Parts Repair parts normally furnished in accordance with applicable part allowance list include: 1 Relay operating coil 2. Motor type, H.P. and nameplate amperes 3. Location of coil terminal studs (left or right hand side of relay) Dimensions (Approximate)

Magnetic Overload Relays Series N147 Full Load Motor Current Amperes Relay Tripping Min. Max. Amps. Coil Nos. 0.50 0.54 0.625 151L901 0.61 0.67 0.77 151L1 0.68 0.72 0.84 151L2 0.73 0.79 0.91 151L3 0.80 0.86 0.99 151L4 0.87 0.94 1.08 151L5 0.95 0.03 1.18 151L6 1.04 1.13 1.30 151L7 1.14 1.24 1.43 151L8 1.25 1.35 1.57 151L9 1.36 1.47 1.68 151L10 1.48 1.61 1.85 151L11 1.62 1.75 2.03 151L12 1.76 1.86 2.14 151L13 1.87 1.96 2.26 151L14 1.97 2.16 2.47 151L15 2.17 2.37 2.72 151L16 2.38 2.61 2.98 151L17 2.62 2.80 3.27 151L18 2.81 2.96 3.41 151L19 2.97 3.23 3.70 151L20 3.24 3.53 4.05 151L21 3.54 3.87 4.43 151L22 3.88 4.23 4.85 151L23 4.24 4.61 5.30 151L24 4.62 5.04 5.79 151L25 5.05 5.50 6.33 151L26 5.51 5.97 6.84 151L27 5.98 6.52 7.47 151L28 6.53 7.10 8.16 151L29 7.11 7.52 8.60 151L30 7.53 8.24 9.40 151L31 8.25 8.95 10.3 151L32 8.96 9.67 11.0 151L33 9.68 10.6 12.1 151L34 10.7 11.6 13.3 151L35 11.7 12.6 14.6 151L36 12.7 13.9 16.1 151L37 14.0 15.1 17.4 151L38 15.2 16.7 19.1 151L39 16.8 18.2 21.0 151L40 18.3 20.0 23.0 151L41 20.1 22.0 25.3 151L42 Full Load Motor Current Amperes Relay Tripping Min. Max. Amps. Coil Nos. 22.1 24.0 27.7 151L43 24.1 26.5 30.4 151L44 26.6 29.0 33.3 151L45 29.1 32.0 36.3 151L146* 32.1 35.0 39.7 151L147* 35.1 38.0 43.4 151L148* 38.1 41.0 48.3 151L149* 41.1 43.1 50.2 151L150* 43.1 46.0 52.8 151L151* 46.1 49.0 58.0 151L152* 49.1 52.0 61.0 151L153* 52.1 55.0 64.5 151L154* 55.1 59.0 68.3 151L155* 59.1 62.0 72.5 151L156* 62.1 67.0 77.3 151L157* 67.1 72.0 83.0 151L158* 72.1 77.0 89.3 151L159* 77.1 84.0 96.7 151L160* 84.1 91.9 105.5 151L161* 92.1 101 116 151L162* 102 114 129 151L163* 115 126 145 151L164* 127 131 150 151L172* 132 143 165 151L165* 144 153 174 151L173* 154 167 192 151L166* 168 183 210 151L174* 184 201 231 151L167* 202 209 254 151L175* 210 230 263 151L176* 231 252 289 151L168* 253 278 318 151L177* 279 306 350 151L178* 307 337 385 151L169* 338 369 424 151L179* 418 457 525 151L180* 462 501 578 151L170* 507 550 635 151L181* NOTE: Full load columns based on coil ratting of 115% to 125% of full load current. * These coils used with overload relays employing terminal boards.

AC and DC Magnetic Relays Series N130 Series N130 Magnetic Relays are recommended for applications where the pilot or control circuit must be established and interrupted repeatedly. These auxiliary control relays in one, two, three and four pole combinations are available for operation on A.C. (480 volts max.) and D.C. (250 volts max.) circuits. All pole combinations can be obtained with or without magnetic blowouts. Optional Features Contact assemblies other than those listed are available with or without blowouts. Specification Operation Function Duty Ambient Insulation MIL-C-2212* Magnetic Auxiliary Control Relay Continuous 50 o C Class B Enclosure For enclosed service Vibration MIL-STD-167 (ships) Type 1 N130 Relay: 3 pole N.O. and 3 pole N.C. *For use where opening and closing of contacts, in excess of 10 milliseconds, under shock, does not affect the operation of associated equipment. Optional Features Contact assemblies other than those listed are available with or without blowouts. Special coil insulation other than Class A applied as standard, can be furnished. In certain instances where ambient conditions or space limitations dictate, Class H coil insulation can be supplied at additional cost. Similarly, Class B insulation can be furnished where required at additional cost. Enclosure either dripproof or watertight are available on special order. Special requirements such as destructive tests, relays for special applications, should be referred to the Home Office. Contact Ratings* Max. Amps A.C. Amps D.C. Volts (60 Hz) without Blowouts with Blowouts 125 25 3 30 250 25 1 30 480 15 - - N130 Relay: 2 pole N.O. Drawings Dimension sketches for all contact combinations are availble without charge. Master plans and special drawings will be quoted on request. * Ratings are non-inductive

AC and DC Magnetic Relays Series N130 Dimensions (in Inches) Without Blowouts With Blowouts No. of Poles Type of Contacts A B C A B C 1 - Single Break SPNO or SPNC 2 1 / 2 4 7 / 8 3 3 / 16 2 1 / 2 5 3 / 4 3 1 / 2 SPNO and SPNC 2 1 / 2 6 3 3 / 16 2 1 / 2 7 11 / 16 3 1 / 2 1 - Double Break SPNO or SPNC 2 1 / 2 4 7 / 8 3 3 / 16 3 5 / 8 5 3 / 4 3 1 / 2 2 - Single Break DPNO or DPNC 2 1 / 2 4 7 / 8 3 3 / 16 3 5 / 8 5 3 / 4 3 1 / 2 DPNO and DPNC 2 1 / 2 6 3 3 / 16 3 5 / 8 7 11 / 16 3 1 / 2 3 - Single Break 3 PNO 3 5 / 8 4 7 / 8 3 3 / 16 4 7 / 16 5 1 / 2 3 1 / 2 3 PNC 3 5 / 8 5 1 / 8 3 3 / 16 4 7 / 16 6 3 1 / 2 3 PNC and 3 PNO 3 5 / 8 6 5 / 8 3 3 / 16 4 7 / 16 7 11 / 16 3 1 / 2 4 - Single Break 4 PNO 4 3 / 4 4 7 / 8 3 3 / 16 5 7 / 8 6 3 / 4 3 1 / 2 4 PNC 4 3 / 4 5 1 / 8 3 3 / 16 5 7 / 8 7 1 / 4 3 1 / 2 4 PNC and 4 PNO 4 3 / 4 6 7 / 8 3 3 / 16 5 7 / 8 8 3 / 8 3 1/ 2 1 /32 insulator (furnished with relay) must be used for steel panel mounting. Single Pole, Single Break D.C. A.C. 1 Pole N.O. 1 Pole N.O. Coil Voltage 1 Pole N.O. 1 Pole N.C. 1 Pole N.C. 1 Pole N.O. 1 Pole N.C. 1 Pole N.C. 115 N130-6410 N130-6411 N130-6419 N130-6510 N130-6511 N130-6519 230 N130-7410 N130-7411 N130-7419 440 N130-8510 N130-8511 N130-8519 When ordering relays with blowouts, specify Cat. No. followed by the letter B. Example: N130-6410B. Ordering Information Repair Parts When ordering catalog listed N130 Relays specify: 1. Catalog Number For special assemblies furnish: 1. Number of poles and contact arrangement (include number and location of blowouts if required) 2. Contact current, voltage, and frequency 3. Coil voltage and frequency 4. Application 5. Repair parts, if required0 Repair parts normally furnished in accordance with applicable part allowance list include: 1 set of contacts 1 set of spring 1 shunt of coil

AC and DC Magnetic Relays Series N130 Single Pole, Double Break D.C. A.C. Coil Voltage 1 Pole N.O. 1 Pole N.C. 1 Pole N.O. 1 Pole N.C. 115 N130-6413 N130-6414 N130-6513 N130-6514 230 N130-7413 N130-7414 440 N130-8513 N130-8514 Double Pole, Single Break D.C. A.C. 2 Poles N.O. 2 Poles N.O. Coil Voltage 2 Poles N.O. 2 Poles N.C. 2 Poles N.C. 2 Poles N.O. 2 Poles N.C. 2 Poles N.C. 115 N130-6420 N130-6421 N130-6429 N130-6520 N130-6521 N130-6529 230 N130-7420 N130-7421 N130-7429 440 N130-8520 N130-8521 N130-8529 Three Pole, Single Break D.C. A.C. 3 Poles N.O. 3 Poles N.O. Coil Voltage 3 Poles N.O. 3 Poles N.C. 3 Poles N.C. 3 Poles N.O. 3 Poles N.C. 3 Poles N.C. 115 N130-6430 N130-6431 N130-6439 N130-6530 N130-6531 N130-6539 230 N130-7430 N130-7431 N130-7439 440 N130-8530 N130-8531 N130-8539 Four Pole, Single Break D.C. A.C. 4 Poles N.O. 4 Poles N.O. Coil Voltage 4 Poles N.O. 4 Poles N.C. 4 Poles N.C. 4 Poles N.O. 4 Poles N.C. 4 Poles N.C. 115 N130-6440 N130-6441 N130-6449 N130-6540 N130-6541 N130-6549 230 N130-7440 N130-7441 N130-7449 440 N130-8540 N130-8541 N130-8549 When ordering relays with blowouts, specify Cat. No. followed by the letter B. Example: N130-6410B.

Reset Relays Type IC5882A300 and IC5882A400 Specification Application Duty Voltage MIL-C-2212 Use for remote resetting of Types IC5882D and IC5882-34 overload relays. Short time, 30 minutes, 200 o C maximum temperature. 600 volts maximum. For Use With Reset Relay Catalog Number Overload Relay 115 VAC 440 VAC Ordering Information Order by catalog number. Overload relay is ordered separately. IC5882D121A* IC5882A400H12 UC5882A400H14 IC5882D122A* IC5882A400H12 UC5882A400H14 IC5882D123A* IC5882A400H12 UC5882A400H14 IIC5882-34KK** IC5882A300B12 UC5882A300B14 IIC5882-34KK** IC5882A300B12 UC5882A300B14 IIC5882-34KK** IC5882A300B12 UC5882A300B14 * Resets only the short reset rod version of Type IC5882D overload relay. ** Resets two Type IC5882-34 overload relays.

Reset Relays Type IC5882A300 and IC5882A400 Outline and Mounting Dimensions (In Inches)

Reset Relays Type IC5882A300 and IC5882A400 Outline and Mounting Dimensions (In Inches)