M3500 Industrial Pressure Transmitter

Similar documents
2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Measurement Instrumentation When it comes to gauges, whether mechanical or digital, The Standard is Meriam. SM

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Smart Pressure Transmitter

Smart Pressure Transmitter

F-1500 SERIES INSERTION TURBINE FLOW METER

Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)

Rosemount 3152K Nuclear Qualified Pressure Transmitter

Smart Pressure Transmitter

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Rosemount 3152N Nuclear Qualified Pressure Transmitter

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

SATRON VDt Differential Pressure Transmitter

F-2700 SERIES INSERTION VORTEX FLOW METER

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

2010TC for Differential Pressure, Pressure and Temperature (Mass Flow)

JUMO dtrans p20 DELTA

Rosemount 4088 MultiVariable Transmitter

F-2600 SERIES INLINE VORTEX FLOW METER

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

AMETEK Model PPC Series Electronic Pressure Calibrator

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

PRESSURE BENCH OPERATING INSTRUCTIONS

압력트랜스미터 Model ADP9000 Series

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

F-2700 SERIES INSERTION VORTEX FLOW METER

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Piezoresistive single crystal silicon pressure transmitter

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

HPC40 Series Calibrator psi

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

Smart Pressure Transmitter

2600T Series Pressure Transmitter

Industrial Pressure Transmitters

Rosemount 4088 MultiVariable Transmitter

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

Rosemount 3051S Electronic Remote Sensor (ERS) System

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

Special Purpose Transmitters

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

FIELD DEVICES CONTROLLERS

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

SATRON VTe pressure transmitter

Monocrystalline silicon smart differential pressure transmitter. High stability, Diaphragm sealed. Benefits. Application

Type A-10 General Purpose Pressure Transmitters

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

CANADA SENSORS TECHNOLOGY INC.

Low Profile Insertion Vortex

Rosemount 3051S Series of Instrumentation

Pressure Instrumentation

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Series Low Pressure Steam Boiler Safety Valves

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Actuators & Positioners Models UP1/2/3/4/5/6/7. Universal Pneumatic Rotary Actuators

ELECTRONIC CONTROLLER

Product presentation SITRANS P310

F-2600 SERIES INLINE VORTEX FLOW METER

Hot Tap Insertion Vortex

HPC600. Handheld Pressure Calibrator. Built-in electric pump. pressure

Series Low Pressure Steam Heating Boiler Safety Valves

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Armstrong In-Line and Insertion Vortex Flow Meters

2-Color Display High-Precision Digital Pressure Switch

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Rosemount 3051S Series of Instrumentation

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Micro-Machined Silicon Transducers

Time Delta S Fixed Transit-Time Flow Meter System

Pressure Transmitter

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

Model 124 Filter Minder & Model 124

NC State University Design and Construction Guidelines Division 23 Energy Management

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

OEM Pressure Transmitters

KDM ARMORED FLOW METER & SWITCH

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Model FVP General Specification. Flanged Vortex Plate. Product Features

L D FB DEVICES FIELDBUS PRESSURE TRANSMITTERS. Features 0 ~125 Pa to 0 ~ 40 MPa. (0 ~0.5 inh 2

Rosemount 3051CFA Annubar Flowmeter

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

2015 RIGHT CHOICE. RIGHT PRICE. RIGHT NOW. DWYER INSTRUMENTS, INC. DWYER INSTRUMENTS, INC. DWYER INSTRUMENTS, INC.

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Pressure transmitter for industrial applications Type MBS 4510

TEL-TRU PRESSURE TRANSMITTERS Threaded Series Model P121

SATRON VT Pressure Transmitter

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

Pressure transmitter for industrial applications Type MBS 4500

Rosemount 1151 Pressure Transmitter

Transcription:

M3500 Industrial Pressure Transmitter The M3500 is a high accuracy industrial pressure transmitter featuring HART communications and a cast aluminum enclosure for indoor or outdoor use. Typical output accuracy is ±0.035% FS with no effect of temperature from -20º C to +50º C (-4º F to +122º F). Differential, gauge, compound and absolute pressure types are offered in a variety of full scale ranges from 17 PSIA to 3000 PSIG. Outputs include a digital display, 4-20 ma (2-wire) with HART and two SPST opto-switches. Four push buttons located beneath the name plate enable users to manually program and maintain the M3500 for pressure, flow or level applications. Programming can also be accomplished using a HART communicator. Hardware is included for 2 pipe and wall mounting. Measurement Accuracy: ±0.025% FS including all effects of linearity, hysteresis, repeatability and temperature from -20º to +50º C (-4º to +122º F) Output (ma / V) accuracy: ±0.05% FS including all effects of linearity, hysteresis, repeatability and temperature from -20º to +50º C (-4º to +122º F) Traceability: NIST traceable certification is standard Pressure ranges: Lower Sensor Limit (LSL) to Upper Sensor Limit (USL) listed below: Differential [DI]: 0-1, 0-5, 0-15, 0-30, 0-100, 0-300, 0-500 PSID Gauge [GI]: 0-15, 0-30, 0-50, 0-100, 0-300, 0-500, 0-1000, 0-3000 PSIG Compound [CI] (PSIG): -15 to +15, -15 to +30, -15 to +50, -15 to +100, -15 to 300, -15 to +500, -15 to +1000, -15 to + 3000 PSIG Absolute [AI]: 0-17.4, 0-38.7, 0-100, 0-1000 PSIA Analog Span Limit DI,GI, and CI types: 4:1 turndown from Upper Sensor Limit (USL) AI: 2:1 turndown from Upper Sensor Limit (USL)

Overpressure Limits DI: 1000 PSI common mode pressure P1 (High) side only: 3x range P2 (Low) side only: 3x range or 150 PSI, whichever is less GI, CI, AI: 2x Full Scale Differential Pressure Sensors Static Pressure effect on zero: worst case 0.025% URL per 100 PSI. See User s Manual for further details. This effect can be corrected by zeroing the unit at the desired static pressure using an equalizing manifold. Static Pressure effect on accuracy: worst case 0.1% URL per 100 PSI. See User s Manual for details. Orientation effect on zero: installation orientations different from factory calibration orientation may cause zero offsets up to 1% F.S. on some ranges. Zero the M3500 in its installed position to eliminate zero offset. Temperature Specifications Operating Range: -20º to +70 C (-4º to +158 F) Calibrated Range: -20º to +50º C (-4º to +122º F) Storage Range: -20º to +70 C (-20º to +158 F) Temperature effect on output accuracy when above 50º C: standard accuracy +0.005% F.S. per ºC Wetted Parts DI: 316L SS and Viton (Kalrez available, consult factory for other o-ring material options) GI, CI, AI: 316L SS Damping: Exponential damping with user adjustable time constant, 0 (Off) to 60 seconds Sensor Zero: push button or HART. Differential Pressure units can have zero fully elevated or suppressed within the Lower and Upper Sensor Limit Trims: analog trims, lower sensor trim and upper sensor trim are available via push button or HART ma output failure modes: Saturation values: 3.9 ma and 20.48 ma Failure values: 3.8 ma and 22.5 ma Internal electronics temperature measurement available from display and via HART. Pressure Applications: differential, vacuum, compound, gauge or absolute Pressure Units: PSI, inches of Water (ref. 20 C, 60 F and 4 C), kg/cm2, MPa, kpa, Pa, mbar, bar, cm of Water (ref. 20 C and 4 C), ft of Water (ref. 20 C, 60 F and 4 C), inches of Mercury @ 0 C, mm of Mercury @0 C, oz/sq in, User defined unit (linear scaling constant from PSI)

Flow applications: Square Root (Sq. Rt.) or Laminar Flow Element (Classical B & C method) applications Flow Units: Volume flow: m3, l (liters), yd3, ft3, in3, US gal (US gallons), I gal (Imperial gallons), bbl (barrel), User defined unit Mass flow: lbs, tons, kg, STon (Short Tons), LTon (Long Tons), User defined unit Time: seconds, minutes, hours, days Flow related features: Low Flow cut off value Total flow since last reset Reset total flow register to zero Total non-resettable flow Level applications: Supports direct head and bubbler type level calculations for linear tanks (vertical), non-linear tanks (horizontal, cylindrical [flat or dished ends] and spherical), and custom strapping tables. Level Units: Height: yards, feet, inches, meters, centimeters, millimeters Liquid volume: cubic inches, US gallons, Imperial gallon, barrels, cubic meters, liters, cubic yards, cubic feet, percent, user defined unit (linear scaling constant) Liquid mass: pounds, tons, kilograms, Short Tons, Long Tons, percent, user defined unit (linear scaling constant) Enclosure: Aluminum casting, designed to NEMA 4 requirements Front and rear caps secured with set screws Dimensions: 5.12 L x 3.56 Dia. x 4.57 H ( 5.12 ) Weight: 2.7 3.0 lbs Conduit connections: ½ NPT (female), 2 ea. 1 permanent plug included Pressure Manifold: Material: 316L SS Pressure connection(s): 1/8 NPT (female) for all pressure sensor types 1/8 NPT(M) x ¼ NPT(F) 316L SS adapter(s) are included Differential Pressure models are available with a standard 2 port manifold or optional 4 port manifold with bleed/flushing connections and plugs (5/16 24 SAE/MS J1926)

2.15 1.00 2.15 0.58 1.00 0.58 2.15 DI Manifold - standard DI Manifold - with optional bleed/flushing ports & plugs (Recommended for liquid DP Applications) GI, CI and AI Manifold permanent plug in P2 side Display 2 line LCD Upper line for up to 5 numeric characters Lower line for up to 6 alphanumeric characters Update rate: 3x per second Floating decimal point Display orientation to be specified with order Standard, Clockwise [90º], Reverse [180º], or Counterclockwise [270º] orientation 1.62 x 0.75 viewable area Standard Display bottom connection(s) Clockwise (90 ) Display right hand connection(s) Reverse (180 ) Display top connection(s) CCW (2700 ) Display left hand connection(s) Name plate: The name plate on top of the M3500 provides model and serial numbers plus other specifications. Loosen the lower right screw and slide to access the keypad. Keypad: Located under the name plate, the keypad consists of 4 arrow keys used for manual programming and trim adjust-ments (sensor zero, lower sensor trim, upper sensor trim and analog trims).

Electrical connections: Six (6) position terminal block for Loop Power & Communication (2- wire) Two opto-coupler SPST switches 1.3 mm diameter holes suitable for 16 25 gauge solid or stranded wire Case grounding screw Test tabs for ma output Comm tabs for HART communications Power: 16 45 V DC Load Curve: Maximum Loop Resistance = (50 * Power Supply Voltage) - 800 Note: HART communication requires a minimum loop resistance of 250Ω (21V DC) Outputs: 4 20 ma (2-wire) HART digital protocol Two each, solid state opto-coupler SPST switches Rating: DC, 0.25 ma max., Von = 0.7 V DC, Voff = 5.4V DC Certifications: CE Mark Environmental Humidity Limits: 5 95% RH Shock, Operating: 30 g, halve-sine, 11mSec pulse (tested in accordance with IEC-60068-2-27) Vibration, Sinusoidal, Operating: 2g peak acceleration at 5-500 Hz (tested in accordance with IEC-60068-2-6) Vibration, Random, Operating: 6g rms acceleration at 5 to 2000 Hz (tested in accordance with IEC-60068-2-64)

Mounting 2 pipe mount with bracket, 316SS, for horizontal or vertical orientation mountings. Includes 2 U-bolts and hardware (zinc plated CS). Standard bracket accommodates pipe mount or surface mounting Standard Accessories P/N Z1065 NIST Certificate with data P/N Z9A683-1 1/8 NPT(M) x ¼ NPT(F) adapter (1 each for AI, CI and GI models), 316L SS P/N Z9A683-2 1/8 NPT(M) x ¼ NPT(F) adapters (2 each for DI models), 316L SS P/N Z9P120 Mounting bracket, 316 SS P/N Z9A64 Mounting hardware kit, zinc plated CS, U-bolts (2 ea.), nuts, washers P/N Z9R86 User s Manual Optional Accessories, Certifications and Tests P/N Z1089 3-valve equalizing manifold kit, 316L SS, c/w pre-bent tubing & tube fittings P/N Z9P130 Material Certification P/N ZA33559 Hydrostatic Pressure Test P/N Z1077 Tag, wired SS

Order Options M3500 Type & Range -DI0001 -DI0005 -DI0015 -DI0030 -DI0100 -DI0300 -DI0500 -GI0015 -GI0030 -GI0050 -GI0100 -GI0300 -GI0500 -GI1000 -GI3000 -CI0015 -CI0030 -CI0050 -CI0100 -CI0300 -CI0500 -CI1000 -CI3000 -AI0017 -AI0038 -AI0100 -AI1000 Description (M3500, universal mounting bracket, hardware, NIST cert and manual) 0 TO 1 PSI Differential, Isolated, 2-port manifold 0 TO 5 PSI Differential, Isolated, 2-port manifold 0 TO 15 PSI Differential, Isolated, 2-port manifold 0 TO 30 PSI Differential, Isolated, 2-port manifold 0 TO 100 PSI Differential, Isolated, 2-port manifold 0 TO 300 PSI Differential, Isolated, 2-port manifold 0 TO 500 PSI Differential, Isolated, 2-port manifold 0 TO 15 PSI Gauge, Isolated 0 TO 30 PSI Gauge, Isolated 0 TO 50 PSI Gauge, Isolated 0 TO 100 PSI Gauge, Isolated 0 TO 300 PSI Gauge, Isolated 0 TO 500 PSI Gauge, Isolated 0 TO 1000 PSI Gauge, Isolated 0 TO 3000 PSI Gauge, Isolated -15 TO +15 PSIG Compound, Isolated -15 TO +30 PSIG Compound, Isolated -15 TO +50 PSIG Compound, Isolated -15 TO +100 PSIG Compound, Isolated -15 TO +300 PSIG Compound, Isolated -15 TO +500 PSIG Compound, Isolated -15 TO +1000 PSIG Compound, Isolated -15 TO +3000 PSIG Compound, Isolated 0 TO 17 PSI Absolute, Isolated 0 TO 38 PSI Absolute, Isolated 0 TO 100 PSI Absolute, Isolated 0 TO 1000 PSI Absolute, Isolated Flushing Port option - DI sensors only -00 Standard pressure manifold DI sensors only - optional 4 port bleed/flush manifold, -04 recommended for liquid service Display Orientation -0 For bottom pressure connections (Standard, 0 degrees) -1 For right hand pressure connection (Clockwise, 90 deg) -2 For left hand pressure connections (CCW, 270 deg) -3 For top pressure connections (Reverse, 180 deg) Other Options 3-valve manifold & tubing, installed, 316SS, 1/4" NPT(F) -A connections, SWP = 3000 PSIG (Z1089) 3-valve manifold (316SS) & tubing (brass), installed, -B 1/4" NPT(F) connections, SWP = 3000 PSIG (Z1089-1) -C Factory Configuration (customer must complete and submit M3500 Configuration Sheet Z9R90 with order) M3500 -CI0100-00 -0 -AC